Rane LRS 4 User Manual

DATA SHEET / MANUAL LRS 4
1
2
4
3
Decora plate (not included)
2.35”
Vr
Vc
LEVEL RECALL SWITCH
Description
e LRS 4 provides a simple interface to end users requiring four predetermined volume levels (may include mute) when used in conjunction with devices equipped with voltage-controlled level inputs. Compatible Rane units include the CP 64, CP 52, DA 26, or MP 44. Units with the Versatile Input Port (VIP) are also compatible, including the Drag Net family of RPM products.
ground) and outputs a single voltage (VC) that is varied depend­ing on the selected LRS 4 button. us, four volume levels can be setup during installation. Any button may be set to any gain between unity and mute. Typically, 4 is set for the highest gain with 3, 2, 1 graduating down to mute, if available.
paired with Decora™ plates for improved architectural beauty. e LRS 4 contains four radio buttons: engaging one button (in,
changing to green) causes any of the other three to disengage (out, changing to black).
e LRS 4 accepts a two-wire DC voltage input (VREF and
e LRS 4 fits in a standard US electrical box and can be
Decora™ plate not included.
Decora is a trademark of Leviton.
Remote Mounting and Wiring
2
3
1k
1
4
5 kΩ
5 kΩ
5 kΩ
5 kΩ
1k
1k
1k
GND
CP 64LRS 4 CP 52 DA 26 MP 44 RPM *
VR VR1or2 VR REF VR REF
VC V1or2 VC VC VC 1-8
GND
VR
VC
GND
GND
e LRS 4 remote assembly mounts in a standard U.S. electrical box with a minimum depth of 2.5" [6.4 cm]. Turn the power to the unit off until all connections are made. It is important to ensure that the Remote Ports are not subjected to sustained voltages outside the range of 0 to 5 volts DC or high levels of static. e device inputs are protected, however you can save a lot of time by taking this precaution. It is a good idea to install the wiring, connect it to the Remote and then make the final connections at the unit.
When wiring to Euroblocks, a minimum wire gauge of 22 is preferred for reliability. If the ground or shield wire is left shorter, it acts as a strain relief for the other wires. Cable with a flexible jacket is easier to use and less likely to damage the con­nections. Be sure to note the wire color of each input in order to facilitate correct wiring to the unit. Make sure wires are free of nicks and that the cable jacket is stripped back sufficiently to allow it to lie in the electrical box with the remote assembly inserted. Connect each wire to the 5-pin connector by fully inserting it in the correct socket and tightening the screw.
Use the flat head #6 screws supplied with the kit to mount the remote assembly and silkscreened front panel to the electrical box. Install the Decora plate of your choice (not included).
Wire Types
Variations in wire type do not greatly affect the performance of the remote controls. However, 22-gauge stranded wire with a flexible jacket is recommended. You may use 3-conductor unshielded remote control signal cable for shorter runs (less than 200 feet [60 meters]) or 2-conductor (1 pair) shielded remote control signal cable (use the shield as the GND return) for longer runs (200 to 1000 feet [60 to 300 meters]). e type of wire required is influenced by your installation and local electrical codes.
Rane Corporation does not provide or source cable. Please contact your local retail or wholesale outlet, not the factory. e following is a short list of suitable cable types:
CONSOLIDATED ELECTRONIC WIRE AND CABLE Plenum cable: Unshielded remote control signal cable CAT. #9896 Shielded remote control signal cable CAT. #9877 or #9852
Block Diagram / Schematic
Use this chart to connect the LRS 4 to various Rane units.
WEICO WIRE & CABLE INC. Communication and control cable: Multiconductor, unshielded CAT. #7606
ALPHA Communication and control cable: Multiconductor, unshielded CAT. #1175C
BELDEN Unshielded remote control signal cable CAT. #88741 Shielded remote control signal cable CAT. #88723
©Rane Corporation 108 02 47th Ave. W., Muk ilteo WA 98275-5 098 TE L 4 25-35 5-600 0 FAX 42 5-347 -7757 WEB www.rane.com
All features & specifications subject to change without notice. DOC 105877
Loading...