Randell RAN031 Operation Manual

OPERATORS MANUAL
This manual provides information on Installation, operating, maintenance, trouble shooting & replacement parts for
CURVED GLASS DISPLAY CASE
NOTIFY CARRIER OF DAMAGE AT ONCE.
It is the responsibility of the consignee to inspect the container upon receipt of same and to determine the possibility of any damage, including concealed damage. Randell suggests that if you are suspi­cious of damage to make a notation on the delivery receipt. It will be the responsibility of the consignee to file a claim with the carrier. We recommend that you do so at once.
OMANUAL_CGDC-8/23/04
1055 Mendell Davis Drive
Jackson, MS 39272
888-994-7636, fax 888-864-7636
unifiedbrands.net
Table of Contents
page 2 ...................................................................................................... Congratulations
page 3 .................................................................................................. Safety Procedures
page 4 ......................................................................................... Serial Number Location
page 4 ........................................................................................ Service and Parts Hotline
page 4-6................................................................................... Randell Limited Warranty
page 7-10 ............................................................................................ Unit Specications
page 11-12................................................................................................ Unit Installation
page 13 ..................................................................................................... Unit Operation
page 13-14 ............................................................................... Preventative Maintenance
page 15 ................................................................................................... Troubleshooting
page 16................................................................................................. Replacement Parts
Congratulations on your recent purchase of Randell food service equipment, and
welcome to the growing family of satised Randell customers.
Our reputation for superior products is the result of consistent quality craftsman­ship. From the earliest stages of product design to successive steps in fabrica­tion and assembly, rigid standards of excellence are maintained by our staff of designers, engineers, and skilled employees.
Only the nest heavy-duty materials and parts are used in the production of Randell brand equipment. This means that each unit, given proper maintenance, will provide years of trouble free service to its owner.
SAFETY PROCEDURES
• Always Disconnect power cord before attempting to work on or to clean
equipment. Turning the switch off is insufcient as the power remains live to
the cabinet and can be a hazard.
• Route the power cord so that it is not likely to be walked on or pinched by other appliances.
• Your unit is equipped with a grounded plug (a plug with 2 blades and a grounding post). Do not defeat the purpose of the plug by removing ground post or using an adapter without properly grounding the outlet.
• Disconnect plug when the appliance will be idled for a long period of time.
• Do not attempt to service this unit yourself as removing covers may cause unnecessary exposure to dangerous voltage.
• Never connect the unit to a power source while standing in water. Wet hands and wet oors should be avoided when connecting any electrical appliance to a power outlet.
• When a replacement part is required, always insist on factory authorized parts.
• When working on units equipped with casters depress caster brake to secure the
2
888-994-7636
unit in place.
In addition, all Randell food service equipment is backed by some of the best warranties in the food service industry and by our professional staff of service technicians.
Retain this manual for future reference.
NOTICE: Due to a continuous program of product improvement, Randell
Manufacturing reserves the right to make changes in design and specica­tions without prior notice.
NOTICE: Please read the entire manual carefully before installation. If certain recommended procedures are not followed, warranty claims will be denied.
MODEL NUMBER
SERIAL NUMBER
INSTALLATION DATE
randell.com
3
Randell Manufacturing Service
and Parts Hotline
The serial number is located inside the display case cabinet.
Service and Parts Hotline 800-621-8560.
Warranty Policies
Congratulations on your purchase of a Randell manufactured piece of equipment. Ran­dell believes strongly in the products it builds and backs them with the best warranty in the industry. Standard with every unit comes the piece of mind that this unit has been thoroughly engineered, properly tested and manufacture to excruciating tolerances, by a manufacturer with over 25 years of industry presence. On top of that front end commit-
ment, Randell has a dedicated staff of certied technicians that monitor our own technical
service hotline at 1-800-621-8560 to assist you with any questions or concerns that may arise after delivery of your new Randell equipment.
WHEN OPTIONAL
5 YEAR COMPRESSOR
WARRANTY APPLIES
1. 1 ear parts replacement of any and all parts that are found defective in material or workmanship
2. Free ground freight to customer specied location for all in warranty parts within
continental U.S.
3. 3 months (90 days) labor reimbursement for any repairs that are caused by Randell’s
use of defective material or workmanship (Reasonable geographic and industry rates do apply)
To request a warranty approval number, call our Field Service Department at 1-888-994-7636.
Randell will provide to the original customer, that owns a Randell piece of equipment, and has an optional compressor warranty with one of the following options:
1. Provide reimbursement to servicing company for the cost of locally obtained replace­ment compressor in exchange for the return of the defective compressor sent back freight prepaid. Note: Randell Manufacturing does limit amount of reimbursement allowed and does require bill from local supply hose where compressor was obtained (customer should not pay servicing agent up front for compressor).
2. Provide repair at the manufacturing facility by requiring that the defective unit be sent back to Randell freight prepaid. Perform repair at the expense of Randell and ship the item back to the customer freight collect.
3. Furnish a complete condensing unit freight collect in exchange for the return of the defective compressor sent back freight prepaid. (Decisions on whether or not to send
complete condensing units will be made by Randell’s in-house service technician).
4
888-994-7636
Warranty Policies (continued)
0WHEN OPTIONAL LABOR
EXTENSION POLICY APPLIES
WHEN EXPORT
WARRANTIES APPLY
ITEMS NOT COVERED
UNDER WARRANTY
Randell Manufacturing will provide reimbursement of labor invoiced to any customer that has an optional labor extension of our standard warranty. (Reasonable geographic and industry rates do apply) Randell offers both 1 and 2 year extensions. Labor exten­sions begin at the end of our standard warranty and extend out 9 months to 1 calendar year or 21 months to 2 calendar years from date of purchase. Please contact Randell
Manufacturing’s technical service hotline at 1-800-621-8560 for details and warranty
authorization numbers.
1. Randell Manufacturing covers all non-electrical components under the same guide­lines as our standard domestic policy.
2. All electrical components operated on 60 cycle power are covered under our standard domestic policy.
3. All electrical components operated on 50 cycle power are covered for 90 days from shipment only.
4. Extended warranty options are not available from the factory.
1. Maintenance type of repairs such as condenser cleaning, temperature adjustments, clogged drains, unit leveling, and gasket replacement or cleaning.
2. Repairs caused by abuse such as broken glass, freight damage, or scratches and dents.
3. Electrical component failure due to water damage from cleaning procedures.
QUOTATIONS
SPECIFICATION &
PRODUCT DESIGN
SANITATION REQUIREMENTS
CANCELLATIONS
Verbal quotations are provided for customer convenience only and are considered invalid in the absence of a written quotation. Written quotations from Randell are valid for 30
days from quote date unless otherwise specied. Randell assumes no liability for dealer
quotations to end-users.
Due to continued product improvement, specication and product design may change
without notice. Such revisions do not entitle the buyer to additions. Changes or replace­ments for previously purchased equipment.
Certain areas require specic anitation requirements other than N.S.F. & U.L. standards. Randell must be advised of these specications before fabrication of equipment. In these
special circumstance, a revised quotation may be required to cover additional costs. Fail­ure to notify Randell before fabrication holds the dealer accountable for all additional charges.
Orders canceled prior to production scheduling entered into engineering/production and cancelled are subject to a cancellation charge (contact factory for details).
randell.com
5
Loading...
+ 11 hidden pages