RAE Systems MultiRAE Gas Specifications

MultiRAE
Wireless portable six-gas monitor with advanced VOC detection capability
The MultiR AE is the most advanced portable chemical detector on the
market. The MultiR AE delivers the broadest PID sensor range in its class and
the versatilit y to support 25 intelligent interchangeable sensor options (such
as PID, NDIR for combustibles and CO
and phosphine) to fully meet the monitoring needs in a variety of applications,
including industrial hygiene, personal protection, leak detection, and HazMat
response.
The MultiR AE’s optional wireless capability improves safety by providing
commanders and safety of cers real-time access to instrument readings and
1
alarm status from any location
for better situational awareness and faster
incident response.
Applications
• Industrial hygiene, personal protection, and
leak detection in industries
such as:
- Aviation (wingtankentr y)
- Chemical
- Environmental
- Oil and gas
- Pharmaceutical
MultiRAE used for worker
exposure monitoring at an
oil refinery
- Shipping/marine
• HazMat response
• Clandestine drug labs
, ammonia, chlorine, formaldehyde,
2
• Highly versatile and customizable
• Best PID in its class (0 to 5,000 ppm range,
0.1 ppm resolution)
• Man Down Alarm with real-time remote wireless
notifcation
• Compliant with MILSPEC810G performance
standard
with AutoRAE 2
FEATURES & BENEFITS
• Wireless access to real-time instrument readings and alarm status from any location
1
• Unmistakable five-way local and remote wireless notification of alarm conditions, including Man Down
1
Alarm
• Intelligent sensors store calibration data, so they can be swapped in the field
2
• Extensive on-board gas libraries (190 VOCs and 55 combustible gases)
• Largest display in its class
• Continuous datalogging (6 months for 5 sensors, 24x7)
• Device Management with Honeywell SafetySuite
MultiRAE Specifications
INSTRUMENT SPECIFICATIONS
4
SIZE 7.6” H x 3.8” W x 2.6” D (193 x 96.5 x 66 mm) WEIGHT 31 oz (880 g)
25 intelligent interchangeable field-replaceable sensors including PID for VOCs, electrochemical
SENSORS
BATTERY OPTIONS,
5
AND
RUNTIME RECHARGE TIME
sensors for toxic gases and oxygen, combustible LEL and NDIR sensors,
NDIR sensor
and CO
2
- Rechargeable Li-ion (~12-hr. runtime, < 6-hr. recharge time)
- Extended duration Li-ion (~18-hr. runtime, < 9-hr. recharge time)
- Alkaline adapter with 4 x AA batteries (~6-hr. runtime)
DISPLAY Monochrome graphical LCD display (128 x 160) with backlighting. Automatic screen “flip” feature.
- Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down
DISPLAY READOUT
Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and reception quality.
- STEL, TWA, peak, and minimum values
KEYPAD BUTTONS 3 operation and programming keys (Mode, Y/+, and N/-) SAMPLING Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions CALIBRATION Automatic with AutoRAE 2 Test and Calibration System or manual
Wireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible (flashing bright red
ALARMS
DATALOGGING
COMMUNICATION AND DATA DOWNLOAD
LEDs), and on-screen indication of alarm conditions
- Man Down Alarm with pre-alarm and real-time remote wireless notification
1
Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
- User-configurable datalogging intervals (from 1 to 3,600 seconds)
- Data download and instrument set-up and upgrades on PC via desktop charging and PC comm. cradle, travel charger, or AutoRAE 2 Automatic Test and Calibration System
- Wireless data and alarm status transmission via built-in RF modem (optional)
WIRELESS NETWORK ProRAE Guardian RealTime Wireless Safety System or EchoView Host-based ClosedLoop System
WIRELESS RANGE (TYPICAL)
OPERATING TEMPERATURE
MultiRAE to RAELink3 [Z1] Mesh modem ~330 feet (100 meters) MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint ~660 feet (200 meters) MultiRAE to WiFi Access Point ~330 feet (100 meters)
4° to 122°F (20° to 50°C)
HUMIDITY 0% to 95% relative humidity (non-condensing) DUST AND WATER RESISTANCE
IP65 ingress protection rating (dust-tight and waterproof against hosing jets coming from all directions) CSA: Class I, Division 1, Groups A, B, C and D, T4 Class II, Division 1; Groups E, F, G; T85°C ATEX: 0575 II 1G Ex ia IIC T4 Ga 2G Ex ia d IIC T4 Gb with IR Sensor installed I M1 Ex ia I Ma
SAFETY CERTIFICATIONS
IECEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor installed I M1 Ex ia I Ma IECEx/ANZEx: Ex ia IIC T4 Ga Ex ia d IIC T4 Gb with IR Sensor installed Ex ia I Ma
EMC/RFI EMC directive: 2004/108/EC PERFORMANCE TESTS MILSTD810G and 461F compliant. LEL CSA C22.2 No. 152; ISA12.13.01
LANGUAGES
WARRANTY
Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese, Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
- Four years on Liq O
- Three years on CO and H
- Two years on non-consumable components and catalytic LEL sensors
sensors
2
S sensors
2
- One year on all other sensors, pump, battery, and other consumable parts
WIRELESS FREQUENCY ISM license free band. IEEE 802.15.4 Sub 1GHz, WiFi 802.11 b/g WIRELESS APPROVALS FCC Part 15, CE R&TTE, Others
6
RADIO MODULE Supports RM900A
SENSOR SPECIFICATIONS
4
RANGE RESOLUTION
PID SENSORS
VOC 10.6 EV (EXT. RANGE)
0 to 5,000 ppm 0.1 ppm
COMBUSTIBLE SENSORS
CATALYTIC LEL NDIR (0-100% LEL METHANE) NDIR (0-100% VOL. METHANE)
0 to 100% LEL 0 to 100% LEL 0 to 100% Vol.
1% LEL 1% LEL
0.1% Vol.
CARBON DIOXIDE SENSOR
CARBON DIOXIDE (CO
ELECTROCHEMICAL SENSORS
AMMONIA (NH CARBON MONOXIDE (CO) CARBON MONOXIDE (CO), EXT. RANGE CARBON MONOXIDE (CO), H CARBON MONOXIDE (CO) + HYDROGEN SULFIDE (H CHLORINE (CL CHLORINE DIOXIDE (CLO ETHYLENE OXIDE (ETO-A) ETHYLENE OXIDE (ETO-B)
) NDIR 0 to 50,000 ppm 100 ppm
2
) 0 to 100 ppm 1 ppm
3
-COMP.
2
S) COMBO
2
) 0 to 50 ppm 0.1 ppm
2
) 0 to 1 ppm 0.03 ppm
2
0 to 500 ppm 0 to 2,000 ppm 0 to 2,000 ppm 0 to 500 ppm 0 to 200 ppm
0 to 100 ppm 0 to 10 ppm
1 ppm 10 ppm 10 ppm 1 ppm
0.1 ppm
0.5 ppm
0.1 ppm
FORMALDEHYDE (HCHO) 0 to 10 ppm 0.05 ppm HYDROGEN CYANIDE (HCN) 0 to 50 ppm 0.5 ppm HYDROGEN SULFIDE (H METHYL MERCAPTAN (CH NITRIC OXIDE (NO) 0 to 250 ppm 0.5 ppm NITROGEN DIOXIDE (NO OXYGEN (O OXYGEN (LIQ O
) 0 to 30% Vol. 0.1% Vol.
2
PHOSPHINE (PH PHOSPHINE (PH SULFUR DIOXIDE (SO
1
Additional equipment and/or software licenses may be required to enable remote wireless monitoring and alarm transmission.
2
RAE Systems recommends calibrating sensors on installation.
3
A two-gas combination sensor is required for a 6-gas configuration.
4
Specifications are subject to change.
5
Specification for non-wireless monitors.
6
Contact RAE Sy stems for country specific wireless approvals
and certificates.
S) 0 to 100 ppm 0.1 ppm
2
-SH) 0 to 10 ppm 0.1 ppm
3
) 0 to 20 ppm 0.1 ppm
2
) 0 to 30% Vol. 0.1% Vol.
2
) 0 to 20 ppm 0.1 ppm
3
H) 0 to 20 ppm 0.1 ppm
3
) 0 to 20 ppm 0.1 ppm
2
Ordering Information (MODEL: PGM-6228)
• Wireless1 and non-wireless configurations are available
• Refer to the Portables Pricing Guide for part numbers for monitors, accessories, sampling and calibration kits, gas, sensors, and replacement par ts
For more information
www.honeywellanalytics.com www.raesystems.com
Europe, Middle East, Africa
Life Safety Distribution GmbH Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number)
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection)
gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution Inc. Tel: +1 847 955 8200 Toll free: +1 800 538 0363
detectgas@honeywell.com
Honeywell RAE Systems
Phone: +1 408 952 8200 Toll Free: +1 888 723 4800
Asia Pacific
Honeywell Analytics Asia Pacific Tel: +82 (0) 2 6909 0300 India Tel: +91 124 4752700 China Tel: +86 10 5885 87883000 analytics.ap@honeywell.com
Technical Services
EMEA: HAexpert@honey well.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com
Datasheet_MultiRAE _DS107011_USEN 04/18 ©2018 Honeywell International Inc.
Device Management with
Honeywell SafetySuite
honeywellanalytics.com/SafetySuite
Loading...