MultiRAE
Wireless portable six-gas monitor with
advanced VOC detection capability
The MultiR AE is the most advanced portable chemical detector on the
market. The MultiR AE delivers the broadest PID sensor range in its class and
the versatilit y to support 25 intelligent interchangeable sensor options (such
as PID, NDIR for combustibles and CO
and phosphine) to fully meet the monitoring needs in a variety of applications,
including industrial hygiene, personal protection, leak detection, and HazMat
response.
The MultiR AE’s optional wireless capability improves safety by providing
commanders and safety of cers real-time access to instrument readings and
1
alarm status from any location
for better situational awareness and faster
incident response.
Applications
• Industrial hygiene, personal protection, and
leak detection in industries
such as:
- Aviation (wingtankentr y)
- Chemical
- Environmental
- Oil and gas
- Pharmaceutical
MultiRAE used for worker
exposure monitoring at an
oil refinery
- Shipping/marine
• HazMat response
• Clandestine drug labs
, ammonia, chlorine, formaldehyde,
2
• Highly versatile and customizable
• Best PID in its class (0 to 5,000 ppm range,
0.1 ppm resolution)
• Man Down Alarm with real-time remote wireless
notifcation
• Compliant with MILSPEC810G performance
standard
• Fully automatic bump testing and calibration
with AutoRAE 2
FEATURES & BENEFITS
• Wireless access to
real-time instrument
readings and alarm
status from any
location
1
• Unmistakable five-way
local and remote
wireless notification of
alarm conditions,
including Man Down
1
Alarm
• Intelligent sensors
store calibration data,
so they can be swapped
in the field
2
• Extensive on-board
gas libraries (190 VOCs
and 55 combustible
gases)
• Largest display in its
class
• Continuous
datalogging (6 months
for 5 sensors, 24x7)
• Device Management
with Honeywell
SafetySuite
MultiRAE Specifications
INSTRUMENT SPECIFICATIONS
4
SIZE 7.6” H x 3.8” W x 2.6” D (193 x 96.5 x 66 mm)
WEIGHT 31 oz (880 g)
25 intelligent interchangeable field-replaceable sensors including PID for VOCs, electrochemical
SENSORS
BATTERY OPTIONS,
5
AND
RUNTIME
RECHARGE TIME
sensors for toxic gases and oxygen, combustible LEL and NDIR sensors,
NDIR sensor
and CO
2
- Rechargeable Li-ion (~12-hr. runtime, < 6-hr. recharge time)
- Extended duration Li-ion (~18-hr. runtime, < 9-hr. recharge time)
- Alkaline adapter with 4 x AA batteries (~6-hr. runtime)
DISPLAY Monochrome graphical LCD display (128 x 160) with backlighting. Automatic screen “flip” feature.
- Real-time reading of gas concentrations; PID measurement gas and correction factor; Man Down
DISPLAY READOUT
Alarm on/off; visual compliance indicator; battery status; datalogging on/off; wireless on/off and
reception quality.
- STEL, TWA, peak, and minimum values
KEYPAD BUTTONS 3 operation and programming keys (Mode, Y/+, and N/-)
SAMPLING Built-in pump. Average flow rate: 250 cc/min. Auto shutoff in low-flow conditions
CALIBRATION Automatic with AutoRAE 2 Test and Calibration System or manual
Wireless remote alarm notification; audible (95 dB @ 30 cm), vibration, visible (flashing bright red
ALARMS
DATALOGGING
COMMUNICATION AND
DATA DOWNLOAD
LEDs), and on-screen indication of alarm conditions
- Man Down Alarm with pre-alarm and real-time remote wireless notification
1
Continuous datalogging (6 months for 5 sensors at 1-minute intervals, 24/7)
- User-configurable datalogging intervals (from 1 to 3,600 seconds)
- Data download and instrument set-up and upgrades on PC via desktop charging and PC comm.
cradle, travel charger, or AutoRAE 2 Automatic Test and Calibration System
- Wireless data and alarm status transmission via built-in RF modem (optional)
WIRELESS NETWORK ProRAE Guardian RealTime Wireless Safety System or EchoView Host-based ClosedLoop System
WIRELESS RANGE
(TYPICAL)
OPERATING
TEMPERATURE
MultiRAE to RAELink3 [Z1] Mesh modem ~330 feet (100 meters)
MultiRAE to EchoView Host, RAEMesh Reader or RAEPoint ~660 feet (200 meters)
MultiRAE to WiFi Access Point ~330 feet (100 meters)
4° to 122°F (20° to 50°C)
HUMIDITY 0% to 95% relative humidity (non-condensing)
DUST AND WATER
RESISTANCE
IP65 ingress protection rating (dust-tight and waterproof against hosing jets coming
from all directions)
CSA: Class I, Division 1, Groups A, B, C and D, T4
Class II, Division 1; Groups E, F, G; T85°C
ATEX: 0575 II 1G Ex ia IIC T4 Ga
2G Ex ia d IIC T4 Gb with IR Sensor installed
I M1 Ex ia I Ma
SAFETY CERTIFICATIONS
IECEx: Ex ia IIC T4 Ga
Ex ia d IIC T4 Gb with IR Sensor installed
I M1 Ex ia I Ma
IECEx/ANZEx: Ex ia IIC T4 Ga
Ex ia d IIC T4 Gb with IR Sensor installed
Ex ia I Ma
EMC/RFI EMC directive: 2004/108/EC
PERFORMANCE TESTS MILSTD810G and 461F compliant. LEL CSA C22.2 No. 152; ISA12.13.01
LANGUAGES
WARRANTY
Arabic, Chinese, Czech, Danish, Dutch, English, French, German, Indonesian, Italian, Japanese,
Korean, Norwegian, Polish, Portuguese, Russian, Spanish, Swedish, and Turkish
- Four years on Liq O
- Three years on CO and H
- Two years on non-consumable components and catalytic LEL sensors
sensors
2
S sensors
2
- One year on all other sensors, pump, battery, and other consumable parts
WIRELESS FREQUENCY ISM license free band. IEEE 802.15.4 Sub 1GHz, WiFi 802.11 b/g
WIRELESS APPROVALS FCC Part 15, CE R&TTE, Others
6
RADIO MODULE Supports RM900A
SENSOR SPECIFICATIONS
4
RANGE RESOLUTION
PID SENSORS
VOC 10.6 EV (EXT. RANGE)
0 to 5,000 ppm 0.1 ppm
COMBUSTIBLE SENSORS
CATALYTIC LEL
NDIR (0-100% LEL METHANE)
NDIR (0-100% VOL. METHANE)
0 to 100% LEL
0 to 100% LEL
0 to 100% Vol.
1% LEL
1% LEL
0.1% Vol.
CARBON DIOXIDE SENSOR
CARBON DIOXIDE (CO
ELECTROCHEMICAL SENSORS
AMMONIA (NH
CARBON MONOXIDE (CO)
CARBON MONOXIDE (CO), EXT. RANGE
CARBON MONOXIDE (CO), H
CARBON MONOXIDE (CO) +
HYDROGEN SULFIDE (H
CHLORINE (CL
CHLORINE DIOXIDE (CLO
ETHYLENE OXIDE (ETO-A)
ETHYLENE OXIDE (ETO-B)
) NDIR 0 to 50,000 ppm 100 ppm
2
) 0 to 100 ppm 1 ppm
3
-COMP.
2
S) COMBO
2
) 0 to 50 ppm 0.1 ppm
2
) 0 to 1 ppm 0.03 ppm
2
0 to 500 ppm
0 to 2,000 ppm
0 to 2,000 ppm
0 to 500 ppm
0 to 200 ppm
0 to 100 ppm
0 to 10 ppm
1 ppm
10 ppm
10 ppm
1 ppm
0.1 ppm
0.5 ppm
0.1 ppm
FORMALDEHYDE (HCHO) 0 to 10 ppm 0.05 ppm
HYDROGEN CYANIDE (HCN) 0 to 50 ppm 0.5 ppm
HYDROGEN SULFIDE (H
METHYL MERCAPTAN (CH
NITRIC OXIDE (NO) 0 to 250 ppm 0.5 ppm
NITROGEN DIOXIDE (NO
OXYGEN (O
OXYGEN (LIQ O
) 0 to 30% Vol. 0.1% Vol.
2
PHOSPHINE (PH
PHOSPHINE (PH
SULFUR DIOXIDE (SO
1
Additional equipment and/or software licenses may be required to
enable remote wireless monitoring and alarm transmission.
2
RAE Systems recommends calibrating sensors on installation.
3
A two-gas combination sensor is required for a 6-gas configuration.
4
Specifications are subject to change.
5
Specification for non-wireless monitors.
6
Contact RAE Sy stems for country specific wireless approvals
and certificates.
S) 0 to 100 ppm 0.1 ppm
2
-SH) 0 to 10 ppm 0.1 ppm
3
) 0 to 20 ppm 0.1 ppm
2
) 0 to 30% Vol. 0.1% Vol.
2
) 0 to 20 ppm 0.1 ppm
3
H) 0 to 20 ppm 0.1 ppm
3
) 0 to 20 ppm 0.1 ppm
2
Ordering Information
(MODEL: PGM-6228)
• Wireless1 and non-wireless configurations are
available
• Refer to the Portables Pricing Guide for part numbers
for monitors, accessories, sampling and calibration
kits, gas, sensors, and replacement par ts
For more information
www.honeywellanalytics.com
www.raesystems.com
Europe, Middle East, Africa
Life Safety Distribution GmbH
Tel: 00800 333 222 44 (Freephone number)
Tel: +41 44 943 4380 (Alternative number)
Middle East Tel: +971 4 450 5800 (Fixed Gas Detection)
gasdetection@honeywell.com
Americas
Honeywell Analytics Distribution Inc.
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
detectgas@honeywell.com
Honeywell RAE Systems
Phone: +1 408 952 8200
Toll Free: +1 888 723 4800
Asia Pacific
Honeywell Analytics Asia Pacific
Tel: +82 (0) 2 6909 0300
India Tel: +91 124 4752700
China Tel: +86 10 5885 87883000
analytics.ap@honeywell.com
Technical Services
EMEA: HAexpert@honey well.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com
Datasheet_MultiRAE _DS107011_USEN
04/18 ©2018 Honeywell International Inc.
Device Management with
Honeywell SafetySuite
honeywellanalytics.com/SafetySuite