Radiant Systems C-10508, C-12012, C-20008, C-18008, C-9008 User Manual

...
5 (1)

COMFORT-COVE

Model C-Series

Warm Your Floor and More™

Installation Instructions & Specifications

Thank you for choosing

Comfort-Cove®!

American Made Product

Radiant Systems, Inc., proudly manufacturers Comfort-Cove® in the Heartland of America; in Valentine, Nebraska, USA. Our ComfortCove® heaters are even compliant with the Buy American Act.

Then & Now

We started like most American businesses, by an individual with an idea and determination. Our story began back in 1984 with founder and owner, Kirk Sharp. Production began in his basement and is now operating out of a 30,000square foot factory. Comfort-Cove® heater has constantly been innovated, engineered, and improved for optimum performance, for the last 28 years.

From the Owner

Thank you for choosing Comfort-Cove® for your heating needs, we take pride in our work and would like to thank you for supporting a local business such as ours, we wouldn’t be here without you.

R. Kirk Sharp

R. Kirk Sharp

FILE #

USA: KKWS.E99303

CANADA: KKWS7.E99303

WARNING

Read Carefully – These instructions are written to help prevent difficulties that might arise during installation of Comfort-Cove® heaters. Studying the instructions saves time.

TO REDUCE RISK OF ELECTRIC SHOCK:

1.Disconnect all power to heater at main service panel before wiring or servicing.

2.All wiring must be in accordance with the National Electrical Code.

3.Verify the power supply voltage coming to heater matches the rating printed on the heater nameplate.

4.This heater is hot when in use. Do not touch.

5.Do not allow foreign objects to enter any ventilation opening.

6.Do not use it in areas where flammable liquids are used or stored.

7.Use this heater only as described in this manual, any other use is not recommended by the manufacturer.

8.This heater is not approved for use in corrosive atmospheres.

9.The heater must be mounted at least 6’ (182.8 cm) or (1.83 m) above the floor.

10.Refer to these instructions for top and bottom clearance requirements.

MAINTENANCE SCHEDULE:

1.No Maintenance Required

www.radiantsystemsinc.com 1-800-314-9303 8AM – 5PM CST

Radiant Systems C-10508, C-12012, C-20008, C-18008, C-9008 User Manual

Comfort-Cove® Mounting & Clearances

1.Locate a wall stud for each bracket such that when the heater is attached to the brackets they are spaced approximately 12” from heater end.

2.Attach brackets to wall studs with wood screws provided, use template provided to mark screw locations depending upon type of ceiling. (Figure 1)

3.Attach back shield to brackets by tilting Back Shield back and allowing Back Shield slot to fall onto bracket hook, then simply bring Back Shield forward locking into place.

4.Hang Front Panel on Back Shield and complete wiring as directed. (Note: if left and or right clearance is restricted attach end caps to front panel before hanging)

5.Complete wiring as shown on Page 3. Can be wired from either end.

6.Secure Front Panel to Back Shield using supplied painted screws and Teflon washers.

7.Attach End Caps (Teflon washer not needed).

CEILING

2-1/2” MIN. (DRY WALL CEILING)

4-1/2” MIN. (LAY IN, VINYL, LATH & PLASTER OR PLASTIC MOLDING

8.Loosen the two outermost painted screws holding the painted Front Panel in place about one revolution, (this is to allow for thermal expansion).

9.When Comfort-Cove® is first energized, an initial breakin fragrance may be noticed – this is normal. (Do not touch while hot)

CAUTION

1.Do not recess Comfort-Cove® heater

2.Never install heater without supplied wall brackets

3.Heater should not be blocked in any manner

4.Do not use plastic conduits for direct connection to Comfort-Cove®

5.DO NOT PAINT HEATER IN ANY MANNER

REAR VIEW

CEILING

34” TO 132”

1” MIN. BETWEEN BOTTOM

OF HEATER AND ANY FABIRC

WALL

6’ MIN

CURTAINS

 

CLEARANCE

 

TO FLOOR

 

FLOOR

CEILING TO CENTER OF

KNOCK OUT

4-3/4” MIN. (DRY WALL CEILING)

6-3/4” MIN. (LAY IN, VINYL, LATH & PLASTER OR PLASTIC MOLDING

4”

1-1/4”

Figure #1

TOP VIEW

2-7/8”

 

WALL

1-1/2”

Page | 2

Loading...
+ 2 hidden pages