Quatech Inc. warrants the DSP-200/300 to be free of defects for one (5) year from the date of purchase.
Quatech Inc. will repair or replace any adapter that fails to perform under normal operating conditions and in
accordance with the procedures outlined in this document during the warranty period. Any damage that results from
improper installation, operation, or general misuse voids all warranty rights.
The authors have taken due care in the preparation of this document and any associated software program(s). In no
event will Quatech Inc. be liable for damages of any kind, incidental or consequential, in regard to or arising out of
the performance or form of the materials presented herein and in the program(s) accompanying this document. No
representation is made regarding the suitability of this product for any particular purpose.
Quatech Inc. reserves the right to edit or append to this document or the product(s) to which it refers at any time and
without notice.
Please complete the following information and retain for your records. Have this information available when
requesting warranty service.
The DSP-200/300 is a dual channel RS-422/RS-485 asynchronous serial adapter for systems
equipped with PCMCIA Type II and/or Type III expansion sockets. The DSP-200/300 is a
PCMCIA Type II (5 mm) card and is PCMCIA PC Card Standard Specification 2.1 compliant.
The DSP-200/300's serial port is implemented using a 16C750 Universal Asynchronous
Receiver/Transmitter (UART), which is the recommended communications interface for
multitasking environments and with applications involving high data transfer rates.
PCMCIA CardCable Assembly
Standard D-9 Female (2)
Figure 1. DSP-200/300 Card and Cable Assembly
The DSP-200/300provides four differential signal pairs (two input and two output): TxD, RxD,
AUXOUT, and AUXIN. TxD and RxD are always present at the connector. The AUXOUT and
AUXIN signals can be used to support RTS/CTS handshaking, external clocking, or external
signal loopback. The default configuration is RTS/CTS handshaking, with RTS transmitted
through AUXOUT and CTS received through AUXIN. The role of AUXOUT and AUXIN can
be set when the DSP-200/300 is configured.
The DSP-200/300 may be configured to operate in either the Full Duplex or Half Duplex mode;
the DSP-200/300 may be configured so that the output drivers are always enabled, RTS or DTR
enable the output drivers, or the output drivers are automatically enabled only when data is being
transmitted. See the Hardware Information section for details on these topics.
Introduction1-1
This page intentionally left blank.
2-1DSP-200/300 (Rev. I and later) User's Manual
2. DOS/Windows 3.x
Two configuration software programs are provided with the DSP-200/300: a Client Driver, and a
card Enabler. Both of these programs are executed from DOS (before entering Windows) and
allow operation of the DSP-200/300 in both the DOS and Windows 3.x environments. For
optimal operation, however, the Client Driver is the preferred method of installation and
configuration. The table below highlights the differences between these programs.
Enabler Client Driver (recommended)
File type: DOS executableFile type: DOS device driver
Interfaces to PCMCIA Card and
Socket Services software
(PCMCIA host adapter
independent)
Allows automatic configuration of
DSP-200/300 adapters upon
insertion (Hot Swapping)
Requires PCMCIA Card and
Socket Services software
Figure 2. Client Driver versus Enabler for DOS/Windows 3.x.
Card and Socket Services software is commercially available from several vendors for most
desktop and laptop PCs. If you are unsure whether Card and Socket Services software is
currently installed on your system, install the DSP-200/300 Client Driver as discussed in
following section. When loaded, the Client Driver will display an error message if Card and
Socket Services software is not detected.
Interfaces directly to Intel
82365SL and other PCIC
compatible PCMCIA host adapters
Does not support automatic
configuration of adapters upon
insertion (Hot Swapping)
Does not require PCMCIA Card
and Socket Services software
DOS/Windows 3.x2-2
2.1 DSP-200/300 Client Driver for DOS
In order to use the DSP-200/300 Client Driver, the system must be configured with Card and
Socket Services software. Card and Socket Services software is not provided with the
DSP-200/300 but is available from Quatech.
IMPORTANT:
Some versions of Card and Socket Services dated before 1993
do not support general purpose I/O cards. If after careful
installation of the Client Driver the adapter does not configure
or operate properly, an updated version of Card and Socket
Services may be required.
2.1.1 Client Driver Installation
The following procedure is used to install the DSP-200/300Client Driver:
1. Copy the Client Driver from the DSP-200/300 distribution diskette onto the system's
hard drive.
2. Using an ASCII text editor, open the system's CONFIG.SYS file located in the root
directory of the boot drive.
3. Locate the line(s) in the CONFIG.SYS file where the Card and Socket Services
software is installed.
4. AFTER the line(s) installing the Card and Socket Services software, add the
following line to the CONFIG.SYS file:DEVICE = drive:\path\
DSP230CL.SYS optionswhere options are the DSP-200/300 Client
Driver command line options discussed on the following pages.
5. Save the CONFIG.SYS file and exit the text editor.
6. Insert the DSP-200/300 into one of the system's PCMCIA slots.
NOTE: Since the DSP-200/300 Client Driver supports "Hot Swapping", it is not
necessary to have the DSP-200/300 installed when booting the system. By inserting the
card before booting, however, the Client Driver will report the adapter configuration
during the boot process thereby verifying the changes made to the CONFIG.SYS.
7. Reboot the system and note the message displayed when the DSP-200/300 Client
Driver is loaded. If the Client Driver reports an "invalid command line option",
correct the entry in the CONFIG.SYS file and reboot the system again. If the Client
Driver reports "Card and Socket Services not found", a version of Card and Socket
Services must be installed on the system or the DSP-200/300 Enabler program must
be used to configure the adapter. If the Client Driver reports the desired adapter
configuration, the installation process is complete and the DSP-200/300 may be
2-3DSP-200/300 (Rev. I and later) User's Manual
removed and/ or inserted from the system as desired. On each insertion into the
PCMCIA socket, the DSP-200/300 will be automatically reconfigured according to
the command line options.
2.1.2 Command Line Options
The DSP-200/300 Client Driver accepts up to eight command line arguments from the user to
determine the configuration of theDSP-200/300. If any arguments are provided, the Client
Driver will attempt to configure any DSP-200/300s with the options specified in the order they
are entered on the command line. Each argument must be enclosed in parenthesis and must be
separated from other arguments by a space on the command line. Within each argument, any or
all of the following parameters may be specified using a comma (no spaces) to separate each
parameter:
Baddressspecifies a the base I/O address of the DSP-200/300in hexadecimal. This address
must reside on an even 8-byte boundary. If this option is omitted, a base address will
be assigned by Card and Socket Services.
Iirqspecifies the interrupt level (IRQ) of the DSP-200/300in decimal. irq must be one of
the following values: 3, 4, 5, 7, 9, 10, 11, 12, 14, 15, or 0 if no IRQ is desired. If this
option is omitted, an interrupt level will be assigned by Card and Socket Services.
Ssocketspecifies which PCMCIA socket the DSP-200/300must be inserted into for this
configuration argument to be used. socket must be in the range 0 - 15. If this option
is omitted, the configuration argument will apply to DSP-200/300s inserted into any
socket.
Odriverspecifies RS-422/485 output driver enable option for the DSP-200/300 port. The
DSP-200/300’s port may be configured for either full duplex or half duplex
operation with this option. If this option is omitted, the default setting is the
RS-422/485 port is configured for full duplex operation with the RS-422/485 output
drivers always enabled. In half duplex mode, the RS-422/485 transmitter may be
enabled and disabled via the RTS (request to send) or DTR (data terminal ready)
signals. Both RTS and DTR are controlled through the Modem Control Register of
the 16750. See the Hardware Information section for more information.
Port Output Driver Option
Always Enabledo0
DTR Controlledo1
RTS Controlledo2
Auto-Toggleo3
Figure 3. DOS Client Output Enable Options.
DOS/Windows 3.x2-4
H instructs the client driver to enable the RTS-CTS modem control handshake on the
RS-422/485 port. When modem control handshaking in enabled, the 16C750
UART’s RTS and CTS signals are connected to the RS-422/485 auxiliary channel.
The auxiliary channel may then be used for handshaking between the DSP-200/300’s
port and a peripheral device. When modem control handshaking is disabled, the
RTS and CTS signals from the 16C750 UART are looped back to each other. If this
option is omitted, the default setting is RTS-CTS modem control handshake
disabled. See the Hardware Information section for more information.
2.1.2.1 Example 1
DEVICE = C:\DSP-200\ DSP230CL.SYS
In example 1, no command line arguments are specified. The Client Driver will configure a
DSP-200/300 inserted into any socket with a base address and IRQ assigned by Card and Socket
Services. The DSP-200/300 RS-422/485 output drivers will always be enabled, and RTS-CTS
modem control handshaking will be disabled.
2.1.2.2 Example 2
DEVICE = C:\DSP-200\DSP230CL.SYS (b290,i11)
In example 2, a single command line argument is provided. The Client Driver will attempt to
configure a DSP-200/300 inserted into any socket with a base address of 290H and IRQ 11. If
address 290H or IRQ 11 is unavailable, the DSP-200/300 will not be configured. If the Client
Driver can successfully configure the DSP-200/300unit, the RS-422/485 output drivers will
always be enabled, and RTS-CTS modem control handshaking will be disabled.
2.1.2.3 Example 3
DEVICE = C:\DSP-200\DSP230CL.SYS(s0,b300,i5,o2)
In example 3, a single command line argument is provided. The Client Driver will attempt to
configure a DSP-200/300 inserted into socket 0 with a base address of 300H and IRQ 5. If
address 300H or IRQ 5 is unavailable, the DSP-200/300 will not be configured. In addition, if a
DSP-200/300 is inserted into any other socket, it will not be configured. If the Client Driver can
successfully configure the DSP-200/300, the RS-422/485 output drivers will be enabled and
disabled via the RTS signal, and RTS-CTS modem control handshaking will be disabled.
2-5DSP-200/300
(Rev. I and later) User's Manual
2.1.2.4 Example 4
DEVICE = C:\DSP-200\DSP230CL.SYS(i5,h,b300)
In example 4, a single command line argument is provided. Because the parameter order is not
significant, the Client Driver will attempt to configure a DSP-200/300 inserted into any socket
with a base address of 300H and IRQ 5. If address 300H or IRQ 5 is unavailable, the
DSP-200/300 will not be configured. If the Client Driver can successfully configure the
DSP-200/300, the RS-422/485 output drivers will always be enabled, and RTS-CTS modem
control handshaking will be enabled on the RS-422/485 port’s auxiliary channel.
2.1.2.5 Example 5
DEVICE = C:\DSP-200\DSP230CL.SYS (b300,i5) (i10) ( )
In example 5, three command line arguments are provided. The Client Driver will first attempt
to configure a DSP-200/300 inserted into any socket with a base address of 300H and IRQ 5. If
address 300H or IRQ 5 is unavailable, the Client Driver will proceed to the second command line
argument and attempt to configure the card with a base address assigned by Card and Socket
Services and IRQ 10. If IRQ 10 is also unavailable, the Client Driver will proceed to the third
command line argument and attempt to configure the DSP-200/300 with a base address and an
IRQ assigned by Card and Socket Services. If the Client Driver can successfully configure the
DSP-200/300, the RS-422/485 output drivers for will always be enabled, and RTS-CTS modem
control handshaking will be disabled.
In example 6, the three command line arguments of example 5 have been rearranged. The Client
Driver will first attempt to configure a DSP-200/300 inserted into any socket with a base address
of 300H and IRQ 5. If address 300H or IRQ 5 is unavailable, the Client Driver will proceed to
the second command line argument and attempt to configure the card with a base address and
IRQ assigned by Card and Socket Services. Since the second command line argument includes
all available address and IRQ resources, the third command line argument will never be reached
by the Client Driver. It is the user's responsibility to place the command line arguments in a
logical order.
The type of configuration shown in example 7 may be desirable in systems where more than one
DSP-200/300 is to be installed. In this example, the Client Driver will attempt to configure a
DSP-200/300 inserted into socket 0 with a base address of 300H and IRQ 5. If the DSP-200/300
is inserted into socket 1, the Client Driver will attempt to configure it with base address 340H
and IRQ 10. This allows the user to force the DSP-200/300's address and IRQ settings to be
socket specific which may simplify cable connections and software development. As in the
previous examples, however, if the requested address or interrupt resources are not available, the
DSP-200/300 will not be configured.
2.1.3 Common Problems
Generic Client Drivers:
Many Card and Socket Services packages include a generic client driver (or SuperClient) which
configures standard I/O devices. If one of these generic client drivers is installed, it may
configure the DSP-200/300 causing the DSP-200/300 client driver to fail installation. In these
cases, the user should do one of the following:
1. Modify the operation of the generic client driver to disable the configuration of
modem/serial port cards. Consult the Card and Socket Services documentation for
availability and details of this feature.
2. Place the DSP-200/300 client driver before the generic client driver in the
CONFIG.SYS.
Available Resources:
One function of the Card and Socket Services software is to track which system resources
(memory addresses, I/O addresses, IRQs, etc.) are available for assignment to inserted PCMCIA
cards. Sometimes, however, the Card Services software assumes or incorrectly determines that a
particular resource is used when it is actually available. Most Card and Socket Services generate
a resource table in a file (typically in the form of an .INI file) which the user can modify to adjust
the available system resources. Consult the Card and Socket Services documentation for
availability and details of this feature.
Multiple Configuration Attempts:
Some Card and Socket Services have a setting which aborts the configuration process after a
single configuration failure (such as a request for an unavailable resource). The user should
change this setting to allow for multiple configuration attempts. Consult the Card and Socket
Services documentation for availability and details of this feature.
2-7DSP-200/300 (Rev. I and later) User's Manual
Older Versions of Card and Socket Services:
Some versions of Card and Socket Services dated before 1993 do not support general purpose
I/O cards. If after careful installation of the Client Driver the DSP-200/300 does not configure or
operate properly, an updated version of Card and Socket Services may be required. Card and
Socket Services software is available from Quatech.
2.2 DSP-200/300 Enabler for DOS
For systems that are not operating PCMCIA Card and Socket Services software, the
DSP-200/300 DOS Enabler may be used to enable and configure the adapter. This Enabler,
DSP230EN.EXE, will operate on any DOS system using an Intel 82365SL or PCIC compatible
PCMCIA host adapter including the Cirrus Logic CL-PD6710 /6720, the VLSI VL82C146, and
the Vadem VG-365 among others.
IMPORTANT:
In order to use the DSP-200/300 Enabler for DOS, the system
MUST NOT be configured with Card and Socket Services
software. If a Card and Socket Services software is installed, the
DSP-200/300 Enabler may interfere with its operation and with the
device(s) it controls.
The DSP-200/300 Enabler does not support automatic configuration of adapters upon insertion,
more commonly referred to as "Hot Swapping". This means the adapter must be installed in one
of the system's PCMCIA sockets before executing DSP230EN.EXE. If more than one adapter is
installed in a system, the Enabler must be executed separately for each adapter. Furthermore,
DSP230EN.EXE should be executed to release the resources used by the adapter before it is
removed from the PCMCIA socket. Since PCMCIA adapters do not retain their configuration
after removal, any adapter that is removed from the system must be reconfigured with the
Enabler after re-inserting it into a PCMCIA socket.
IMPORTANT:
The Enabler requires a region of high DOS memory when configuring
a DSP-200/300. This region is 1000H bytes (4KB) long and by default
begins at address D0000H (the default address may be changed using
the "W" option). If a memory manager such as EMM386, QEMM, or
386Max is installed on the system, this region of DOS memory must
be excluded from the memory manager's control. Consult the
documentation provided with the memory manager software for
instructions on how to exclude this memory region.
DOS/Windows 3.x2-8
2.2.1 Command Line Options
To configure a DSP-200/300 in the system, the Enabler requires one command line argument
from the user to determine the configuration of the card. This argument must be enclosed in
parenthesis and within the argument, any or all of the following parameters may be specified
using a comma
Ssocketspecifies which PCMCIA socket the DSP-200/300 must be inserted into for this
Baddressspecifies the base I/O address of the DSP-200/300 in hexadecimal. This address
Iirqspecifies the interrupt level (IRQ) of the DSP-200/300 in decimal. irq must be one
Waddressspecifies the base address of the memory window required to configure the
(no spaces) to separate each parameter:
configuration argument to be used. socket must be in the range 0 - 15. This option is
required if the 'R' option is not used.
must reside on an even 8-byte boundary. This option is required if the 'R' option is
not used.
of the following values: 3, 4, 5, 7, 9, 10, 11, 12, 14, 15, or 0 if no IRQ is desired.
This option is required if the 'R' option is not used.
DSP-200/300. Set address = D0 for a memory window at segment D000, address =
D8 for a memory window at segment D800, etc. Valid settings for address are C8,
CC, D0, D4, D8, and DC. If this option is omitted, a memory window at segment
D000 will be used.
Odriverspecifies RS-422/485 output driver enable option for theDSP-200/300. The
DSP-200/300’s port may be configured for either full duplex or half duplex
operation with this option. If this option is omitted, the default setting is the
RS-422/485 port is configured for full duplex operation with the RS-422/485 output
drivers always enabled. In half duplex mode, the RS-422/485 transmitter may be
enabled and disabled via the RTS (request to send) or DTR (data terminal ready)
signals. Both RTS and DTR are controlled through the Modem Control Register of
the 16750. See the Hardware Information section for more information.
H instructs the enabler to enable the RTS-CTS modem control handshake on the
RS-422/485 port. When modem control handshaking in enabled, the 16C750
UART’s RTS and CTS signals are connected to the RS-422/485 auxiliary channel.
The auxiliary channel may then be used for handshaking between the DSP-200/300’s
RS-422/485 port and a peripheral device. When modem control handshaking is
disabled, the RTS and CTS signals from the 16C750 UART are looped back to each
other. If this option is omitted, the default setting is RTS-CTS modem control
handshake disabled. See the Hardware Information section for more information .
Before removing a DSP-200/300 from its PCMCIA socket, the Enabler should be executed to
free the system resources allocated when the card was installed. For this operation the Enabler
provides on additional command line option:
Rinstructs the enabler to release the resources previously allocated to the DSP-200/300
. When the 'R' option is used, any settings specified by the 'B', 'I', 'O', and 'H' options
are ignored.
2.2.1.1 Example 1
DSP230EN.EXE
In example 1, no command line argument is specified. The Enabler will report an error and
display the proper usage of the command.
2.2.1.2 Example 2
DSP230EN.EXE (s0,b300,i5)
In example 2, the Enabler will configure the DSP-200/300 in socket 0 with a base address of
300H and IRQ 5 using a configuration memory window at segment D000. The DSP-200/300
unit's RS-422/485 output drivers will always be enabled, and RTS-CTS modem control
handshaking will be disabled.
.2.1.3 Example 3
2
DSP230EN.EXE (i10,h,b340,s1)
In example 3, the Enabler will configure the DSP-200/300 in socket 1 with a base address of
340H and IRQ 10 using a configuration memory window at segment D000. The DSP-200/300's
RS-422/485 output drivers will always be enabled, and RTS-CTS modem control handshaking
will be enabled on the RS-422/485 auxiliary channel.
DOS/Windows 3.x2-10
2.2.1.4 Example 4
DSP230EN.EXE (s0,b300,i3,wd8)
In example 4, the Enabler will configure the DSP-200/300 in socket 0 with a base address of
300H and IRQ 3 using a configuration memory window at segment D800. The DSP-200/300's
RS-422/485 output drivers will always be enabled, and RTS-CTS modem control handshaking
will be disabled
2.2.1.5 Example 5
DSP230EN.EXE (o1,i5,b340,s1)
In example 2, the Enabler will configure the DSP-200/300 in socket 1 with a base address of
340H and IRQ 5 using a configuration memory window at segment D000. The DSP-200/300's
RS-422/485 output drivers will be enabled and disabled via the DTR signal, and RTS-CTS
modem control handshaking will be disabled
2.2.1.6 Example 6
DSP230EN.EXE (s0,b300,i5,r)
In example 6, the Enabler will release the configuration used by the DSP-200/300 in socket 0
using a configuration memory window at segment D000. The base address and IRQ parameters
are ignored and may be omitted.
2.2.1.7 Example 7
DSP230EN.EXE (s1,r,wcc)
In example 7, the Enabler will release the configuration used by the DSP-200/300 in socket 1
using a configuration memory window at segment CC00.
2.2.2 Common Problems
Memory Range Exclusion:
The Enabler requires a region of high DOS memory when configuring aDSP-200/300. This
region is 1000H bytes (4KB) long and by default begins at address D0000H (the default address
may be changed using the "W" option). If a memory manager such as EMM386, QEMM, or
386Max is installed on the system, this region of DOS memory must be excluded from the
memory manager's control. Consult the documentation provided with the memory manager
software for instructions on how to exclude this memory region.
2-11DSP-200/300
(Rev. I and later) User's Manual