Quadra-Fire LOGS-QFI35 Placement Instructions

Log Set Assembly: LOGS-QFI35
REFRACTORY
TAB
SRV2225-703
SRV2225-704
SRV2225-705
SRV2225-701
SRV2225-702
SRV2225-710
SRV2225-706
Models: QFI35, QFI35-C
CAUTION: Logs are fragile, handle with care.
LOG PLACEMENT INSTRUCTIONS
SRV2225-703
SRV2225-704
SRV2225-705
SRV2225-701
SRV2225-702
SRV2225-706
SRV2225-710
Figure 2. Install Back Refractory
Install back refractory by placing it against the back of the fi rebox. The back refractory must be held in the upright position until the side refractory is installed. Install the left side refractory as shown in Figure 3. Bend the refractory tab down as shown in Figure 4. Repeat this step for the right refractory panel.
REFRACTORY
TAB
Figure 3. Install Side Refractory
Quadra-Fire • LOGS-QFI35 Log Instructions • 2225-935 Rev. C • 7/11
Figure 4. Bend Refractory Tab
1
LOG CONTACTS LEFT REFRACTORY PANEL
FLAT SPOTS FOR LOG #6 AND LOG #3
MATE SLOT WITH GRATE TINE
SLOT
LOG CONTACTS LEFT REFRACTORY PANEL
POSITION LOG ON FLAT SPOT
LOG CONTACTS BACK REFRACTORY PANEL
FLAT SPOT FOR LOG #7
LOG RESTS ON LOG SUPPORT
MATE LOG PIN WITH LOG SLOT
MATE GRATE BAR WITH LOG GROOVE
2
3
4
LOG SUPPORT
LOG SUPPORT
ANDIRONS
OUTER TINES
LOG PINS
LOG RESTS ON LOG SUPPORT
LOG GROOVE CONTACTS GRATE TINE
1
LOG PINS
ANDIRONS
OUTER TINES
LOG RESTS ON LOG SUPPORT
1
LOG GROOVE CONTACTS GRATE TINE
Figure 5.
Log #1 (SRV2225-701): Position the groove on the log with the right grate tine as shown in Figure 6. The opposite end of
the log will rest on the log support. Rotate the opposite end of the log clockwise until it contacts the refractory panel.
FLAT SPOTS FOR LOG #6 AND LOG #3
LOG CONTACTS LEFT REFRACTORY PANEL
2
MATE SLOT WITH GRATE TINE
Figure 7. Place Log #2
Log #2 (SRV2225-703): Mate the grate tine with the slot on the bottom of Log #2. The back end of the log rests on the log
support. The side of the log will contact the left refractory as shown in Figure 7.
Figure 6. Location of Log #1
SLOT
Figure 8. Slot on Log #2
POSITION LOG ON FLAT SPOT
FLAT SPOT FOR LOG #7
3
4
LOG CONTACTS LEFT REFRACTORY PANEL
LOG RESTS ON LOG SUPPORT
LOG CONTACTS BACK REFRACTORY PANEL
Figure 9. Place Log #3
Log #3 (SRV2225-702): Position the left end of the log on the at spot of Log #2 as shown in Figure 7 and Figure 9. The
right end of the log rests on the log support and touches the back refractory. The left end of the log should contact the left refractory panel. Log #4 SRV(2225-705): Mate the slot on the bottom of Log #4 with the right log pin. Refer to Figure 11 for location of log slot. Rotate the right end of the log clockwise until the groove on the end of the log mates with the grate bar.
Quadra-Fire • LOGS-QFI35 Log Instructions • 2225-935 Rev. C • 7/112
MATE LOG PIN WITH LOG SLOT
Figure 10. Place Log #4
MATE GRATE BAR WITH LOG GROOVE
LOG SLOT
LOG SLOT
FLAT SPOT FOR LOG #6
MATE LOG PINS WITH LOG SLOTS
LOG SLOTS
LOG RESTS ON FLAT SPOT
LOG GROOVE MATES WITH GRATE BAR
LOG RESTS ON FLAT SPOT
5
7
6
LOG RESTS ON FLAT SPOT
FLAT SPOT FOR LOG #6
5
MATE LOG PINS WITH LOG SLOTS
Figure 11. Log #4
Log #5 (SRV2225-710): Position Log #5 as shown in Figure 12. Mate the middle and left log pins with the two slots located
on the bottom of the log. See Figure 13 for locations of log slots. The smaller end should be pointed toward the right side of the fi rebox.
LOG SLOTS
Figure 13. Log #5
Log #6 (SRV2225-706): Rest the wide end of the log on the at spot of Log #5 as shown in Figure 12 and Figure 14. Place
the narrow end on the fl at spot of Log #2. Flat spot on Log #2 is indicated in Figure 7.
Figure 12. Place Log #5
LOG RESTS ON FLAT SPOT
Figure 14. Place Log #6
6
LOG RESTS ON FLAT SPOT
LOG RESTS ON FLAT SPOT
Figure 15. Place Log #7
Log #7 SRV2225-704): Note the location of the groove on the underside of the log. Place the opposite end on the at spot
on Log #3. See Figure 9. Mate the groove on the underside of the log with the grate bar as shown in Figure 15, centered between the andirons.
7
LOG GROOVE MATES WITH GRATE BAR
Quadra-Fire • LOGS-QFI35 Log Instructions • 2225-935 Rev. C • 7/11
3