Log Set Assembly: LOGS-QFI35
Models: QFI35, QFI35-C
CAUTION: Logs are fragile, handle with care.
LOG PLACEMENT INSTRUCTIONS
SRV2225-703
SRV2225-704
SRV2225-705
SRV2225-701
SRV2225-702
SRV2225-706
SRV2225-710
Figure 1. Refractory and Logs Installed
Figure 2. Install Back Refractory
Install back refractory by placing it against the back of the fi rebox. The back refractory must be held in the upright position
until the side refractory is installed. Install the left side refractory as shown in Figure 3. Bend the refractory tab down as
shown in Figure 4. Repeat this step for the right refractory panel.
REFRACTORY
TAB
Figure 3. Install Side Refractory
Quadra-Fire • LOGS-QFI35 Log Instructions • 2225-935 Rev. C • 7/11
Figure 4. Bend Refractory Tab
1

LOG CONTACTS
LEFT REFRACTORY
PANEL
FLAT SPOTS FOR LOG #6 AND LOG #3
MATE SLOT WITH
GRATE TINE
LOG CONTACTS LEFT
REFRACTORY PANEL
POSITION LOG
ON FLAT SPOT
LOG CONTACTS BACK
REFRACTORY PANEL
MATE LOG
PIN WITH
LOG SLOT
MATE GRATE BAR
WITH LOG GROOVE
LOG SUPPORT
LOG GROOVE
CONTACTS
GRATE TINE
LOG PINS
ANDIRONS
OUTER TINES
LOG RESTS ON
LOG SUPPORT
1
LOG GROOVE
CONTACTS
GRATE TINE
Figure 5.
Log #1 (SRV2225-701): Position the groove on the log with the right grate tine as shown in Figure 6. The opposite end of
the log will rest on the log support. Rotate the opposite end of the log clockwise until it contacts the refractory panel.
FLAT SPOTS FOR LOG #6 AND LOG #3
LOG CONTACTS
LEFT REFRACTORY
PANEL
2
MATE SLOT WITH
GRATE TINE
Figure 7. Place Log #2
Log #2 (SRV2225-703): Mate the grate tine with the slot on the bottom of Log #2. The back end of the log rests on the log
support. The side of the log will contact the left refractory as shown in Figure 7.
Figure 6. Location of Log #1
SLOT
Figure 8. Slot on Log #2
POSITION LOG
ON FLAT SPOT
FLAT SPOT
FOR LOG #7
3
4
LOG CONTACTS LEFT
REFRACTORY PANEL
LOG RESTS ON
LOG SUPPORT
LOG CONTACTS BACK
REFRACTORY PANEL
Figure 9. Place Log #3
Log #3 (SRV2225-702): Position the left end of the log on the fl at spot of Log #2 as shown in Figure 7 and Figure 9. The
right end of the log rests on the log support and touches the back refractory. The left end of the log should contact the left
refractory panel.
Log #4 SRV(2225-705): Mate the slot on the bottom of Log #4 with the right log pin. Refer to Figure 11 for location of log
slot. Rotate the right end of the log clockwise until the groove on the end of the log mates with the grate bar.
Quadra-Fire • LOGS-QFI35 Log Instructions • 2225-935 Rev. C • 7/112
MATE LOG
PIN WITH
LOG SLOT
Figure 10. Place Log #4
MATE GRATE BAR
WITH LOG GROOVE