Instructions for the DDI-3 DataPort Accessory Card
I. INTRODUCTION
The DDI-3 DataPort Accessory Card converts a QSC amplifier’s DataPort to an eight-position terminal block, providing convenient access to the pins of the amplifier’s DataPort; this is useful for connecting input signals or implementing a remote on/off (standby) system without using a DataPort cable. Four solder pads provide access to the amplifier’s output voltage and current monitors.
QSC ISA, CX, DCA, SRA, PowerLight, and PowerLight 2 Series amplifiers feature a DataPort for every two audio channels. Therefore, one- and two-channel models have one DataPort, while four-channel models have two and eight-channel models have four. On the four- and eight-channel CX and DCA models, only the DataPort for channels 1 and 2 has the power supply standby feature. ISA models do not have power supply standby or output voltage and current monitoring.
ON/OFF CONTROL
A TTL-type logic
standby. Opening the short will restart the power supply, with no inrush current surge. To control multiple amplifiers with a single switch, use diodes to isolate them from each other (Figure 3).
low
at DataPort pin 2, such as a short to ground (Figure 2), puts the power supply in
INPUTS
Through its DataPort, an amplifiers input sensitivity (the input voltage required to reach full rated output power) is approximately 3 volts RMS, at full gain and with an 8 load on each channel. Use the + and ­terminals for balanced connections; the AGND terminal is audio ground, for conecting a cable shield when necessary. For unbalanced connections, connect the signal conductor to the + terminal and the cable shield to both the AGND and - terminals.
OUTPUT MONITORS
VMN1
IMN1
IMN2
VMN2
Figure 2. On/off control of a single amplifier
VMN1
IMN1
IMN2
VMN2
STBY
CGND
CH2+
CH2-
AGND
CH1+
CH1-
AGND
STBY
CGND
CH2+
CH2-
AGND
CH1+
CH1-
AGND
VMN1
IMN1
IMN2
VMN2
STBY
CGND
CH2+
CH2-
AGND
CH1+
CH1-
AGND
Figure 1. The DDI-3
Run
Standby
There is a VMON and an IMON output for each amplifier channel. The VMON output is a sample of the amplifier channels output voltage, scaled so that full output into an 8 load equals approximately 3 volts RMS. The I
MON output is a voltage proportional to and in phase with the amplifier channels output current; the
scaling varies among the various amplifier models; contact QSC for details if you wish to use this feature.
II. INSTALLATION
The DDI-3 kit (QSC part # SG-000235-00) includes these items:
DDI-3 board Two #4-40 × ¼” black screws Installation guide
Use this procedure to install the DDI-3:
VMN1
IMN1
IMN2
VMN2
VMN1
IMN1
IMN2
VMN2
Figure 3. On/off control of several amplfiers with a single switch
STBY
CGND
CH2+
CH2-
AGND
CH1+
CH1-
AGND
Run
STBY
CGND
CH2+
CH2-
1N914, 1N4148, etc.
AGND
CH1+
CH1-
AGND
1. Turn off the amplifier.
2. If you are using the output voltage or current monitoring features, solder the wires to the appropriate pads on the DDI-3 before attaching it to the amplifier.
3. Plug the DDI-3 into the amplifiers DataPort. Use the two screws included to secure it; do not overtighten them.
4. To attach a wire to the DDI-3, strip about 5 mm (0.2) of insulation from the wire. Twist the exposed wire strands together and make sure there are no stray ones. Turn the screw on the terminal counterclockwise until you can fully insert the wire end into the terminal. Turn the screw clockwise until the terminal clamps the wire securely. Repeat for all the wires needed.
Standby
5. The amplifier is ready for use.
2