Q-Logic 2310FL, 2310F User Manual

Q
Simplify
QLA®2310F/2310FL User’s Guide
2-Gb Fibre Channel to PCI-X Host Bus Adapters
FC2354603-00 A Page i
QLA2310F/2310FL User’s Guide
0
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no representation nor warranty that such applications are suitable for the specified use without further testing or modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
No part of this document may be copied nor reproduced by any means, nor translated nor transmitted to any magnetic medium without the express written consent of QLogic Corporation.
Linux is a registered trademark of Linus Torvalds.
Microsoft, Windows NT, Windows Server, and Windows 2000 are trademarks or registered trademarks of Microsoft Corporation.
QLogic, the QLogic logo, and QLA are registered trademarks of QLogic Corporation.
SANblade is a trademark os QLogic Corporation.
Solaris is a registered trademark of Sun Microsystems, Inc.
SPARC is a registered trademark of SPARC International, Inc. Products bearing SPARC trademarks are based on an architecture developed by Sun Microsystems, Inc.
WinZip is a registered trademark of WinZip Computing, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners
Q
Rev A 8/20/04
Document Revision History
© 2004 QLogic Corporation. All rights reserved worldwide.
First Published: July 2004
Printed in U.S.A.
QLogic Corporation, 26650 Aliso Viejo Parkway, Aliso Viejo, CA 92656, (800) 662-4471 or (949) 389-600
Page ii FC2354603-00 A
Table of Contents
Section 1 Introduction
1.1 How to Use this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.3 What is Fibre Channel? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.4 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
Section 2 QLA2310F/2310FL
2.1 QLA2310F/2310FL HBA Components . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2.1.1 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.1.2 Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2.2 Installation in the Computer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2.2.1 Installation Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.3 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2.4 Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-6
2.5 Agency Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.5.1 QLA2310F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.5.1.1 EMI and EMC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-7
2.5.1.2 Product Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.5.2 QLA2310FL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.5.2.1 EMI and EMC Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
2.5.2.2 Product Safety Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
Section 3 Troubleshooting
3.1 Problems After Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2 Hardware Problem Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.3 System Configuration Problem Checklist . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3.4 Fibre Channel Problem Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
FC2354603-00 A Page iii
QLA2310F/2310FL User’s Guide 2-Gb Fibre Channel to PCI-X Host Bus Adapters
Figures
Figure Page
2-1 QLA2310F HBA Layout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
2-2 QLA2310FL HBA Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2-3 QLA2310F/2310FL HBA LED Activity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Tables
Table Page
2-1 QLA2310F/2310FL Board Operating Environment . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
2-2 QLA2310F/2310FL Board Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-5
Q
Page iv FC2354603-00 A
1.1

How to Use this Guide

The SANblade QLogic host bus adapters (HBAs) supported in this document are described in the following paragraphs. They are collectively referred to as the QLA2310F/2310FL HBA unless otherwise noted.
QLA
QLA
The QLA2310F/2310FL HBAs are 64-bit, 66-MHz PCI-X to Fibre Channel optical media.
First, install the QLA2310F/2310FL HBA according to the directions in the appropriate hardware installation section. Secondly, install the software driver according the directions in the associated readme.txt file.
1.2
®
2310F (single channel, full-height bracket, optical media)
®
2310FL (single channel, low-profile bracket, optical media)

General Description

Section 1
Introduction
Thank you for selecting the QLA2310F/2310FL Fibre Channel (FC) HBA. The QLA2310F/2310FL HBA is an intelligent, high-performance, DMA bus master host adapter designed for high-end systems. The intelligence and performance are derived from the ISP23xx chips, making the QLA2310F/2310FL HBA a leading-edge host adapter. The ISP23xx combines a powerful RISC processor, a Fibre Channel protocol manager (FPM) with one or more 2-Gb Fibre Channel transceivers, and a peripheral component interconnect-extended (PCI-X) local bus interface in a single-chip solution. The QLA2310F/2310FL HBA supports all FC peripherals that support private loop direct attach (PLDA) and fabric loop attach (FLA). Installation of the QLA2310F/2310FL HBA is quick and easy.
1.3

What is Fibre Channel?

Fibre Channel technology is outlined in the SCSI-3 Fibre Channel Protocol (SCSI-FCP) standard. Fibre Channel is a high-speed data transport technology used for mass storage and networking. It connects mainframes, super computers, workstations, storage devices, and servers.
Fibre Channel supports data transfer rates up to 200 MBps half-duplex and 400 MBps full-duplex on copper and optical interfaces. The QLA2310F/2310FL HBAs use a multimode optical interface for intermediate distances (less than
FC2354603-00 A 1-1
1 – Introduction Features
1.4

Features

Q
500 meters at the data rate of 1 Gbps; less than 300 meters at the data rate of 2Gbps).
With its increased connectivity and performance, Fibre Channel is the I/O technology preferred and used by system designers.
Compliance with PCI Local Bus Specification revision 2.2
Compliance with PCI-X Addendum (revision 1.0) to the PCI Local Bus
Specification
Compliance with Third Generation Fibre Channel-Physical and Signaling
Interface (FC-PH-3) standard
Compliance with Fibre Channel-Arbitrated Loop (FC-AL-2) standard
Compliance with U.S. and international safety and emissions standards
Support for bus master DMA
Fast!UTIL BIOS utility to customize the configuration parameters on the QLA23xx
HBA and attached drives
Supports Fibre Channel protocol-SCSI (FCP-SCSI) and IP
Supports point-to-point fabric connection (F-PORT FABRIC LOGIN)
Supports Fibre Channel security protocol (FC-SP) using DH-CHAP (Solaris
SPARC 2.6, 7, 8, and 9 only)
Supports fabric device management interface (FDMI) on the following operating
systems: Windows 2000; Windows Server 2003; Red Hat Linux 8 and 9, Advanced Server 2.1; SuSE SLES 8; Solaris 2.6, 7, 8 and 9
Using FDMI, storage area network (SAN) administrators can view device-specific information (for example, driver version, firmware version, and model number) from a central console, regardless of the device manufacturer. This information is kept at the FC switch and viewed through the switch's management application or third party SAN management applications.
1-2 FC2354603-00 A
Loading...
+ 12 hidden pages