Quick Start Guide Host Bus Adapter Installation
200, 2300, 2400, and 2500 Series
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation assumes no
responsibility for its use, nor for any infringements of patents or other rights of third parties which may result from its
use. QLogic Corporation reserves the right to change product specifications at any time without notice. Applications
described in this document for any of these products are for illustrative purposes only. QLogic Corporation makes no
representation nor warranty that such applications are suitable for the specified use without further testing or
modification. QLogic Corporation assumes no responsibility for any errors that may appear in this document.
Document Revision History
Revision A, March 31, 2011
Revision B, April 11, 2012
Revis
ion C, March 27, 2014
ChangesSections Affected
Added model QOE2562 to Table 1-1“Supported Host Bus Adapters” on page 1
Added new FCC Rules for QOE2562 section.“EMI and EMC Requirements” on page 3
Added model QOE2562 to the warranty information.
Changed MIC compliance to Korean compli-ance.
Added a separate hardware installation procedure
“Agency Certification” on page 3
“Product Safety Compliance” on page 5
“CE Mark 89/336/EEC EMC Directive compliance:”
on page 3
“Installing the QOE2562 Adapter” on page 8
for the QOE2562, including a new illustration
(Figure 2-2).
Added a note preceding Tab le A -4 .Appendix AAdapter LEDs
Added Ta bl e A- 5 , defining the LED scheme for the
Quick Start Guide—Host Bus Adapter Installation
200, 2300, 2400, and 2500 Series
ivFC0054505-01 C
1Introduction
This guide provides details on how to install and configure your new QLogic Host
Bus Adapter, including installing the adapter hardware, adapter driver, and
®
QConvergeConsole
It also lists the Host Bus Adapters covered, provides additional resources, and
describes warranty details.
Supported Host Bus Adapters
Table 1-1 lists the QLogic Host Bus Adapters supported by this guide.
Table 1-1. Products Affected
Product NamePart Number
QLA200FL0210403
QLE220EL0210402
QLA2310FC2310401
, the QLogic Web management utility.
QLA234xFC5010409
QLA24xxFC2410401
QLE2460PX2510401
QLE2462PX2510401
QLE2464PX2610401
QLE2560PX2810403
QLE2562PX2810403
QLE2564PX4810402
QOE2562QM2810401-01
1FC0054505-01 C
1–Introduction
CLASS I LASER PRODUCT
Additional Resources
Additional Resources
To obtain the most current drivers, management tools, user instructions, and
documentation, download the latest version from the QLogic Web site,
Downloads and Documentation page:
http://driverdownloads.qlogic.com
For a general overview of QConvergeConsole and installation details, refer to the
Installation Guide QConvergeConsole GUI (2400, 2500, 2600, 3200, 4000, 8100,
8200, 8300, and 10000 Series) (part number SN0051105-00).
For descriptions and procedures related to using QConvergeConsole, refer to the
QConvergeConsole Help system.
For details on installing QConvergeConsole CLI and using the commands in it,
see the User’s Guide QConvergeConsole CLI (2400, 2500, 2600, 3200, 4000, 8100, 8200, 8300 Series) (part number SN0054667-00).
Warranty
The following sections contain additional information about the QLogic Host Bus
Adapter laser safety, agency certification, and product safety compliance. For
warranty details, see the QLogic Web site:
http://www.qlogic.com/Support/warranty.aspx
Laser Safety, FDA Notice
This product complies with DHHS Rules 21CFR Chapter I, Subchapter J. This
product has been designed and manufactured according to IEC60825-1 on the
safety label of laser product.
Class 1 Laser Product
Appareil laser de classe 1
Produkt der Laser Klasse 1
Luokan 1 Laserlaite
Caution—Class 1 laser radiation when open
Do not view directly with optical instruments
Attention—Radiation laser de classe 1
Ne pas regarder directement avec des instruments optiques
Vorsicht—Laserstrahlung der Klasse 1 bei geöffneter Abdeckung
Direktes Ansehen mit optischen Instrumenten vermeiden
Varoitus—Luokan 1 lasersäteilyä, kun laite on auki
Älä katso suoraan laitteeseen käyttämällä optisia instrumentteja
2FC0054505-01 C
1–Introduction
Warranty
Agency Certification
The following sections contain a summary of EMC/EMI test specifications
performed on the QLogic Host Bus Adapters to comply with radiated emission,
radiated immunity, and product safety standards.
EMI and EMC Requirements
FCC Part 15 compliance: Class A (QLE236x, QLA24xx, QLA2xx, QLE2464,
QLE2xx, QLE25xx, QOE2562), Class B (QLA23xx, QLE24xx)
FCC compliance information statement: This device complies with Part 15 of
the FCC Rules. Operation is subject to the following two conditions: (1) this device
may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
ICES-003 compliance: Class A (QLE236x, QLA24xx, QLA2xx, QLE2xx,
QLE2464, QLE25xx, QOE2562), Class B (QLA23xx, QLE24xx)
For QLE236x, QLA24xx, QLA2xx, QLE2xx, QLE2464, QLE25xx, and
QOE2562 adapters: This Class A digital apparatus complies with Canadian
ICES-003. Cet appareil numérique de la classe A est conformé à la norme
NMB-003 du Canada.
For QLA23xx and QLE24xx adapters: This Class B digital apparatus
complies with Canadian ICES-003. Cet appareil numérique de la classe B
est conformé à la norme NMB-003 du Canada.
CE Mark 89/336/EEC EMC Directive compliance:
EN55022:1998/CISPR22:1997 - Class A (QLE236x, QLA2440, QLA246x,
QLA2xx, QLE2xx, QLE2464, QLE25xx, QOE2562)
Class B (QLA23xx, QLE2440, QLE246x)
EN55024:2010
Immunity Standards
EN61000-4-2 : ESD
EN61000-4-3 : RF Electro Magnetic Field
EN61000-4-4 : Fast Transient/Burst
EN61000-4-5 : Fast Surge Common/ Differential
EN61000-4-6 : RF Conducted Susceptibility
EN61000-4-8 : Power Frequency Magnetic Filed
EN61000-4-11 : Voltage Dips and Interrupt
EN61000-3-2 : Harmonic Current Emission
EN61000-3-3 : Voltage Fluctuation and Flicker
VCCI compliance: Class A (QLE236x, QLA2440, QLA246x, QLE2xx, QLE2464,
QLE25xx, QOE2562), Class B (QLA23xx, QLE2440, QLE246x, QLA2xx)
3FC0054505-01 C
1–Introduction
Warranty
AS/NZS CISPR22 compliance: Class A (QLE236x, QLA2440, QLA246x,
QLA2xx, QLE2xx, QLE2464, QLE25xx, QOE2562), Class B (QLA23xx, QLE2440,
QLE246x)
CNS 13438 compliance: Class A (QLE236x, QLA2440, QLA246x, QLE2464,
QLE25xx), Class B (QLA23xx, QLE2440, QLE246x)
For QLE236x, QLA2440, QLA246x, and QLE2464 adapters
This is a Class A product. In a domestic environment, this product may
cause radio interference, in which case, the user may be required to take
adequate measures.
Korean compliance: Class A (QLA2310F, QLA2340, QLA2342, QLE236x,
QLA24xx, QLE2xx, QLE2464, QLE25xx, QOE2562). Class B (QLE24xx, QLA2xx)
QLE2464, QLE25xx, and QOE2562 Host Bus Adapters: Korea Class A
Certified
Product Name/Model:
Certification holder:
Manufactured date:
Manufacturer/Country of origin:
A class equipment
(Business purpose info/
telecommunications
equipment)
Fibre Channel Host Bus Adapter
QLogic Corporation
Refer to date code listed on product
QLogic Corporation/USA
As this equipment has undergone
EMC registration for business purpose,
the seller and/or the buyer is asked to
beware of this point and in case a
wrongful sale or purchase has been
made, it is asked that a change to
household use be made.
4FC0054505-01 C
1–Introduction
Warranty
Korean Language Format—Class A
For QLE24xx and QLA2xx adapters: Korea MIC Class B Certified
Product Name/Model:
Certification holder:
Manufactured date:
Manufacturer/Country of origin:
This chapter describes how to install and configure the QLogic Host Bus Adapter
in three simple steps:
Step 1. Install the Hardware
Step 2. Install the Adapter Driver
Step 3. Install QConvergeConsole
®
Step 1. Install the Hardware
To install the adapter hardware, you need to open the computer and locate the
appropriate bus slot. If necessary, consult your computer system manual for
instructions to remove the computer cover.
Keep the adapter in the antistatic bag until installation. The Host Bus
Adapter contains parts that can be damaged by electrostatic discharge
(ESD). Before handling the Host Bus Adapter, use standard methods to
discharge static electricity. Place the Host Bus Adapter on the bag when
examining it. Retain the bag for future use.
Installing the QLA2xx, QLA23xx, QLA24xx, QLE2xx, QLE236x,
QLE24xx, and QLE25xx Adapters
The QOE2562 installation procedure differs from these adapter models; see
“Installing the QOE2562 Adapter” on page 8
To install the adapter hardware:
1.Power off the computer and all attached devices such as monitors, printers,
and external components.
2.Disconnect the power cable.
3.Remove the computer cover and find an appropriate empty bus slot.
7FC0054505-01 C
2–Installation
Host Bus Adapter
64-bit PCI-X Slot
x4 PCI Express
®
Slot
(x8 physical slot or
QLE25xx Adapters)
higher required for
or
Lever
Screw
Adapter Retaining
Bracket
Slot Covers
System Chassis
Step 1. Install the Hardware
4.Pull out the slot cover (if any) by removing the screw or releasing the lever.
5.Install the low-profile bracket (if required).
6.Grasp the adapter by the top edge and seat it firmly into the appropriate slot
(see Figure 2-1).
Installing the QOE2562 Adapter
Figure 2-1. Server Motherboard and Slots
7.Refasten the adapter’s retaining bracket using the existing screw or lever.
8.Close the computer cover.
9.Plug the Fibre Channel cable into the adapter.
10.Plug in the power cable and turn on the computer.
To install the QOE2562 adapter hardware:
1.Power off the computer and all attached devices such as monitors, printers,
and external components.
2.Disconnect the power cable.
3.Remove the computer cover and find an appropriate empty bus slot.
4.Remove the SFP transceivers.
8FC0054505-01 C
2–Installation
QOE2562 Host
System Chassis
PCIe Slot
Bus Adapter
Step 2. Install the Adapter Driver
5.Grasp the adapter by the top edge and seat it firmly into the appropriate slot
(see Figure 2-2).
Figure 2-2. Server Motherboard and Slots
6.Replace the SFPs.
7.Close the computer cover.
8.Plug the Fibre Channel cable into the adapter.
9.Plug in the power cable and turn on the computer.
Step 2. Install the Adapter Driver
Drivers for QLogic Host Bus Adapters are available per adapter model, protocol,
and OS. Ensure that adapter drivers are always updated to the latest version.
To install the adapter driver:
1.Go to the QLogic Downloads and Documentation page:
http://driverdownloads.qlogic.com
2.In the search box, type the QLogic model name.
(Alternatively, you can use the guided search option: Select the adapter
type, model, and OS, and then click Go.)
3.In the search results list, locate and select the appropriate driver for your
operating system.
4.View the product details Web page to ensure that you have the correct
driver.
9FC0054505-01 C
2–Installation
Step 3. Install QConvergeConsole
5.For additional information, click the Read Me and Release Notes icons
under Support Files.
6.Click Download Now.
7.Save the file to your computer.
8.Follow the driver installation instructions in the Read Me document.
Step 3. Install QConvergeConsole
QLogic QConvergeConsole tools provide easy management of QLogic Fibre
Channel, Intelligent Ethernet, and Converged Network Adapters within SANs. The
QConvergeConsole management suite includes a browser-based GUI, a
lightweight CLI, and an integrated VMware
single-pane-of-glass management.
For details about the components of the QConvergeConsole suite, refer to the
Data Sheet QConvergeConsole (part number SN0058083-00). The data sheet
helps you decide which QConvergeConsole option to choose, based on the
available features and utilities, as well as the supported OS, browsers, adapters,
and architectures.
®
vCenter™ Plug-in to provide
To install QConvergeConsole:
1.Go to the QLogic Downloads and Documentation page:
http://driverdownloads.qlogic.com
2.In the search box, type the QLogic model name.
(Alternatively, you can use the guided search option: Select the adapter
type, model, and OS, and then click Go.)
3.In the search results list, locate and select the QConvergeConsole version
for your operating system.
4.View the product details Web page to ensure that you have the correct
QConvergeConsole version.
5.For additional information, click the Read Me and Release Notes icons
under Support Files.
6.Click Download Now.
7.Save the file to your computer.
8.Follow the installation instructions in the Read Me document.
10FC0054505-01 C
A
Adapter LEDs
This appendix explains the meaning of the LEDs for each of the supported
adapters.
Table A-1. QLA2310 and QLA200 Host Bus Adapter LED Scheme
Green LEDYellow LEDActivity
OffOffPower off
OnOnPower
OnOffOnline
OffOnLink
OffFlashingLoss of synchronization
Green and yellow LEDs
flashing alternately
Table A-2. QLA234x, QLA210, and QLE220 Host Bus Adapter LED Scheme
Green LEDAmber LEDActivity
OffOffPower off
OnOnPower
OnOffOnline
OffOnLink
OffFlashing Loss of synchronization
Alternate
flashing
FlashingOffBeacon
Alternate
flashing
Firmware error
Firmware error
11FC0054505-01 C
A–Adapter LEDs
NOTE
Table A-3. QLA24xx and QLE24xx Host Bus Adapter LED Scheme
Yellow LEDGreen LEDAmber LEDActivity
OffOffOffPower off
OnOnOnPower on (before firmware initializa-
tion)
FlashingFlashingFlashingPower on (after firmware initialization)
Yellow, green, and amber LEDs
flashing alternately
OffOffOn and
flashing
OffOn and
flashing
On and
flashing
FlashingOffFlashingBeacon
OffOffOnline, 4Gbps link/I/O activity
OffOnline, 2Gbps link/I/O activity
Firmware error
Online, 1Gbps link/I/O activity
Table A-4 reflects the output of QLE25xx LEDs when the system is booted to
an OS. The LED output when the LEDs are controlled in the Fast!UTIL BIOS
menus support beaconing only when a port is selected.
Table A-4. QLE25xx Host Bus Adapter LED Scheme
Yellow LED
(8Gbps)
Green LED
(4Gbps)
Amber LED
(2Gbps)
Activity
OffOffOffPower off
OnOnOnPower on (before firmware initializa-
tion)
FlashingFlashingFlashingPower on (after firmware initialization)
Yellow, green, and amber LEDs
flashing alternately
12FC0054505-01 C
Firmware error
A–Adapter LEDs
NOTE
Table A-4. QLE25xx Host Bus Adapter LED Scheme (Continued)
Yellow LED
(8Gbps)
OffOffOn and
OffOn and
On and
flashing
FlashingOffFlashingBeacon
Green LED
(4Gbps)
flashing
OffOffOnline, 8Gbps link/I/O activity
Amber LED
(2Gbps)
Online, 2Gbps link/I/O activity
flashing
OffOnline, 4Gbps link/I/O activity
Activity
Table A-5 reflects the output of QOE2562 LEDs when the system is booted
to an OS. The LED output when the LEDs are controlled in the Fast!UTIL
BIOS menus support beaconing only when a port is selected.
Table A-5. QOE2562 Host Bus Adapter LED Scheme
Physical Port
Activity
LED 1LED 2
OffOffPower off
Green onYellow onPower on (before firmware initialization)
Green onYellow onPower on (after firmware initialization)
Green and yellow LEDs flashing alternately Firmware error