Qasair FA 60F-1, FA 90F-1, FA 90F-2, MT 60L-1, MT 90L-1 Installation Instructions Manual

...
VENTILATION SYSTEMS
INSTALLATION INSTRUCTIONS
QASAIR Rangehoods are made to suit
domestic Australian cooking conditions and
traditions. QASAIR incorporates a system
that is efficient over all modern-cooking
of quietness in the kitchen.
Now the latest domestic cooking appliances
including indoor barbecues, deep fryers,
exotic wok appliances and high speed gas
burners can be used in the design of the
kitchen without the worry or fear of filling the
house with grease, odours, steam or heat.
QASAIR Installation Instructions
1
Important information 2 Instructions for Models 4 FA / MT / MC / UCH / UV / NDCH / ECH Instructions for Models 13 H Series & PYR Instructions for Models 17 3F / SF / ST / MAJ / IN / STA / SMF / FAS Instructions for Models 23 TR CT Instructions for Models 25 BRH / BAR Instructions for Models 27 4F / VIS / PRE / D 400 / D 500 / SQ 420 / FPR / MA /HAM / BUR Instructions for Special Rangehoods 35
Lamp Replacement 36 Ducting Pieces 37 Installation Ideas 50 Exclusions 55 Warranty
CONTENTS
QASAIR Installation Instructions
2
CONDARI PTY LTD makes over 120 different models of QASAIR Rangehoods plus many specials designed by architects and interior designers.
It is important to follow the installation instructions for different models.
The following is general advice for the installation of QASAIR Rangehoods and is meant as a guide.
Firstly, there are many different cooking appliances on the market today and we list some here. Electric Eco, Ceramic hotplates, Teppanyaki plates and Induction hotplates, which need special cooking equipment. There are gas hotplates with four burners and a wok burner or fish burner of all different heat output. Many companies offer a vario system with individual two gas burners, a wok burner, electric ceramic hotplate, an electric griller or barbecue and an induction hotplate. There are three gas cooking appliances with an open flame griller or barbecue.
Gas regulations require different heights for different brands of hoods. QASAIR hoods can be fitted 600 mm above the trivet of a gas hotplate. This is due to the fact they do not have plastic motors or plastic internal parts. Over the open flame gas grillers or gas barbecues the filters must be 1200 mm above the cooking surface. Therefore, a special rangehood is required to comply with the regulations. There are no regulations over an electric hotplate except for those set out by the manufacturer.
All decorative hoods in the Sapphire, Gallery, Imperial, Argyle, Federation and Heritage range should be set from 700 mm to 800 mm above the cooking surface. When the rangehoods are against a wall in a galley or partially enclosed kitchen, they can be higher, but should not exceed 900 mm to 1000 mm.
For island situations they should not exceed 800 mm above as movement around the bench will result in fumes being drawn away from the catchment area of the hood.
We have a model, the Thermidor which is installed in the ceiling and is higher than the recommendation. This is for aesthetic reasons such as a view or window setting. The hood is fitted with three fans to provide the necessary air movement.
The Executive Range of hoods are all meant to be put into cupboards over hotplates and can vary in height due to the kitchen design. All of these hoods can be 600 mm above a gas and electric hotplate. Above a gas wok burner or electric griller or barbecue they should be 700 mm to 800 mm above. Over an induction cooktop the minimum distance should be 700 mm above, this applies to the Marcel (MC1000L-2), all Undermounted (NDCH), Mini Trim (MT 60/90L-1) and all Undercupboard (UCH) models.
1. The installation of QASAIR Rangehoods must comply with the information in
this booklet QASAIR Rangehoods are designed and made to work efficiently over all domestic cookware available on the Australian market.
2. Every QASAIR Rangehood must be ducted to the outside atmosphere by the
use of zinc-alume duct or non-porous and non-flammable materials. We do not recommend the use of any type of flexible ducting. Rangehoods must not be vented into a wall cavity or a ceiling space. This prevents a build up of grease, which can be a fire risk. Ensure the external outlet vent does not restrict the airflow in any way, as this may result in reduced performance.
IMPORTANT
information
QASAIR Installation Instructions
3
3.
QASAIR Rangehoods must be ducted in duct work equivalent to the outlet
of the rangehood ie: The cross sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from QASAIR is available to ensure optimum performance. Always use non­flammable materials to minimise the risk of fire in the duct at a later date.
4. Ensure all ducting pieces are correctly fitted and sealed with either duct tape
or silicone to ensure that fumes do not escape into the ceiling space and seep into living areas through vents or light fittings. The installation and fitting of the rangehood should be done in such a way that will allow the unit to be removed if service is required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not covered by warranty.
5. Always adequately ventilate the room when the rangehood in use at the same
time as appliances burning gas or other fuels.
6. WARNING: Incorrect venting will result in additional noise and a reduction in
efficiency. Exhaust air must not be discharged into any chimney or flue, which may carry combustible products from other sources.
A/ Do not discharge the air-flow from the rangehood into a flue used for
exhausting fumes from burning gas or fuel;
B/ For cleaning purposes please refer to page 36 of installation instructions for
stainless steel;
C/ If cleaning is not carried out in accordance with the instructions as listed on
page 36, you may have an increased risk of fire;
D/ Accessible parts of the rangehood may become hot when used with
cooking appliances;
E/ This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
7. Do not flambé under the rangehood.
8. If the supply cord is damaged, an authorised service centre or licensed
electrician must replace it.
9. NOTE: QASAIR recommend an air movement of between 1000 to 1400 cubic
metres per hour over an indoor barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues for optimum results. Barbecues should be positioned under the centre of the hood where the fans are mounted and not near the outer edges where leakage may occur.
10. The lights in the canopy rangehoods are LED and come with a night light and
the concealed units come with compact fluorescent lights and these should be turned off after use.
11. To reduce the risk of fixing screws coming in contact with live parts, do not
drill or screw into the rangehood. Live wires are encapsulated where possible to prevent user contact. If necessary drill from the inside out and only through single sheet material.
12. QASAIR domestic rangehoods are not to be used over barbecues approved
for outdoor use only.
13. QASAIR make a range of hoods specifically for outdoor barbecues in alfresco
areas under the CONDOR name.
14. QASAIR can manufacture rangehoods to be used over commercial cookers in
domestic applications.
QASAIR Installation Instructions
4
Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. Connection to be carried out by a registered electrician.
Duct direction (For all models except MT)
Before installing your rangehood check whether it has the fan mounted for back or top ducting. For top ducting, the fan must be fixed to the back of the unit with the air outlet at the top, and for back ducting, the fan must be fixed to the top of the unit with the air outlet at the back. To change from top to back or back to top, proceed as follows:
Duct direction for UCH models
The motor shown is fitted to the back plate (P) and this plate is attached to the hood by screws (S). To change from top to back undo all the screw (S), 14 of them and remove the plate and turn it around so the motor points out the way required. Fit all the screws again and tighten.
Duct direction for UV / FA models
The photo's show a UV rear ducted and a FA top ducted unit. To change the direction undo the motor bolts (B) on both sides of the motor. The motor can then be changed to point in the direction required. Replace the bolts and tighten.
INSTRUCTIONS
for models
FA 60F-1
FA 90F-1
FA 90F-2
MT 60L-1
MT 90L-1
MC 10L-2
UCH 50F-1
UCH 80H-1
UCH 80H-2
UCH 100H-2
UCH 120H-2
UV 500F-1
UV 800F-1
UV 800F-2
UV 1000F-2
UV 1200F-2
UV 1200F-3
UV 1500F-3
NDCH 60F-1
NDCH 80F-1
NDCH 80F-2
NDCH 90F-1
NDCH 90F-2
NDCH 100F-2
NDCH 120F-2
ECH 600F-1
ECH 800F-1
ECH 800F-2
ECH 900F-1
ECH 900F-2
ECH 1000F-2
ECH 1200F-2
QASAIR Installation Instructions
5
Installation instructions Fold Away model (FA)
1. The rangehood can now be installed by inserting screws in the three holes provided on each side or
to the top or back by drilling your own mounting holes as required.
2. When installed, cover the access holes to the side fixing screws with the plastic plugs supplied.
3. Fit filters.
Duct direction for MT model only
To change the duct direction, proceed as follows:
1. Remove the screws from the fan access panel and remove access panel.
2. Unscrew the 2 x 700 hex head screws fixing the fan to the hood.
3. Rotate the fan assembly so that the air outlet meets with the rangehood outlet hole through which
you are going to vent (top or back).
4. Replace the 2 x 7mm screws.
5. Refit the fan access panel.
Installation instructions Mini Trim model & Marcel (MT & MC)
1. Fit a shelf at 410mm from the base of the cupboard.
2. Note hinge location prior to drilling.
3. Work from the centre line mark and drill 4 x M5 to M8 holes.
4. For top ducted models, cut out hole for the ducting allow 20mm clearance.
5. Fix left and right hand mounting brackets (supplied) 145mm from the base of the cupboard flush with
the rear of the unit. Notch to the back.
6. Lift rangehood onto mounting brackets by holding either end. DO NOT use the slide mechanism as
this may cause damage.
7. Insert the 4 x 50mm pan head screws supplied through the shelf and into the rangehood. Turn
clockwise to level the rangehood.
8. Fix the rangehood position by inserting 2 x no 8 1/2 inch screws through the left and right hand brackets.
9. Fit doors.
10. Minor adjustments may be required on the rangehood handle. Loosen the screws on the rear of the
handle and adjust handle position and re- tighten. The rangehood handle can be replaced.
11. All of the rangehoods shown on pages 1 and 8 are supplied with a 10AMP plug and lead for
connection to a 10AMP GPO, which must be in an accessible position.
12. The handle can be removed and replaced with one made by the cabinet maker to fit in with the
kitchen cabinets. The MT 90 has 3 screws and the MT 60 has 2 screws. These can be accessed by sliding the facia out and un-screwing the front from underneath and behind the facia. The handle will come off by tilting it forward from the top.
QASAIR Installation Instructions
6
Installation instructions
For Under cupboard and Universal model (UCH, UV, ECH & NDCH) Make cut out to the following sizes.
MODEL HOOD SIZE BASE SIZE CUT OUT DIMENSION
UCH 50F 243 x 480 280 x 500 260 x 485
UCH 80H 243 x 780 280 x 800 260 x 785
UCH 100H 243 x 980 280 x 1000 260 x 985
UCH 120H 243 x 1180 280 x 1200 260 x 1185
UV 500F 390 x 480 430 x 500 398 x 485
UV 800F 390 x 780 430 x 800 398 x 785
UV 1000F 390 x 980 430 x 1000 398 x 985
UV 1200F 390 x 1180 430 x 1200 398 x 1185
UV 1500F 390 x 1480 430 x 1500 398 x 1485
NDCH 60F 243 x 580 280 x 600 260 x 585
NDCH 90F 243 x 880 280 x 900 260 x 885
NDCH 100F 243 x 980 280 x 1000 260 x 985
NDCH 120F 243 x 1180 280 x 1200 260 x 1185
ECH 600F 340 x 580 380 x 600 348 x 585
ECH 800F 340 x 780 380 x 800 348 x 785
ECH 900F 340 x 880 380 x 900 348 x 885
ECH 1000F 340 x 980 380 x 1000 348 x 985
ECH 1200F 340 x 1180 380 x 1200 348 x 1185
Loosen screws A and B by turning anti-clockwise. Insert rangehood into cut out and turn screw ‘C’ clockwise to align rangehood with cupboard base. Do not over tighten. Tighten screw ‘A’ by turning clockwise to lock fixing bracket. Fit off ductwork as required. To remove rangehood, turn screw ‘D’ clockwise.
Models ECH
NDCH90 NDCH 100 NDCH 120
Models UCH
UV NDCH60
QASAIR Installation Instructions
7
Executive Range - FOLDAWAY
FA 60F-1 Top / Back ducted FA 90F-1 Top / Back ducted FA 90F-2 Top / Back ducted
Executive Range - MINI TRIM
MT 60L-1 Top / Back ducted MT 90L-1 Top / Back ducted
QASAIR Installation Instructions
8
Executive Range - MARCEL
MC 10L-2 Top / Back ducted
Executive Range - UNDERCUPBOARD
UCH 50F-1 Top / Back ducted UCH 80H-1 Top / Back ducted UCH 80H-2 Top / Back ducted UCH 100H-2 Top / Back ducted UCH 120H-2 Top / Back ducted
A WORD OF WARNING FOR THE UCH MODELS OVER INDUCTION COOKTOPS. If using this hood and boiling for long periods of time (15 minutes plus) condensation will form on the filters. Using high speed will cause water to drop back on to the hot plate. In all cases use low speed and only one motor even if the hood has two. It is better to use a Universal rangehood, as it has a larger filter area.
QASAIR Installation Instructions
9
Executive Range - UNIVERSAL
UV 500F-1 Top / Back ducted UV 800F-1 Top / Back ducted UV 800F-2 Top / Back ducted UV 1000F-2 Top / Back ducted UV 1200F-2 Top / Back ducted UV 1200F-3 Top / Back ducted UV 1500F-3 Top / Back ducted
Executive Range - UNDERMOUNTED
NDCH 60F-1 Top / Back ducted
QASAIR Installation Instructions
10
Executive Range - UNDERMOUNTED
NDCH 80F-1 Top / Back ducted NDCH 80F-2 Top / Back ducted
Executive Range - UNDERMOUNTED
NDCH 90F-1 Top / Back ducted NDCH 90F-2 Top / Back ducted NDCH 120F-2 Top / Back ducted
QASAIR Installation Instructions
11
Executive Range - UNDERMOUNTED
NDCH 100F-2 Top / Back ducted
QASAIR Installation Instructions
12
Elite Range - ECH
ECH 600F-1 Top / Back ducted ECH 800F-1 Top / Back ducted ECH 900F-1 Top / Back ducted
Elite Range - ECH
ECH 800F-2 Top / Back ducted ECH 900F-2 Top / Back ducted ECH 1000F-2 Top / Back ducted ECH 1200F-2 Top / Back ducted
QASAIR Installation Instructions
13
Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations. Connection must be carried out by a registered electrician.
Recommended fixing points
Mounting bracket: Use vertically punched slot for centre line Before cutting any holes check ceiling space for structural beams. It may be possible at this point to relocate the hood position.
The fixing points are prepunched holes in the back of the hood and it may be necessary to drill through the back of the hood into the wall studs.
Cleaning of Stainless Steel
QASAIR Rangehoods are made from stainless steel type 304 and is considered 18/8 SS.
This means the stainless steel is 18% chromium and 8% nickel in the mix. The steel becomes stainless by the chromium oxidising in the open air to form a protective coating of chromium oxide. This coating can be upset by coming in contact with a substance that will attack the chromium oxide, such as a lemon solution or any cleaner with a preservative in it.
Therefore, only clean the rangehood with an approved stainless steel cleaner. Methylated spirits or warm soapy water with soap will do it. Do not use powder detergent.
INSTRUCTIONS
for models
600HL-1
700HL-1
900HL-1
1200HL-2
1500HL-2
PYR 900L-1
QASAIR Installation Instructions
14
Installation instructions
1. Remove canopy and flue from boxes and check you have correct model and flue.
2. Locate centre point of stove.
3. Use level or plumb line to mark centre up to ceiling.
4. Mark level line for base of canopy 700-800mm above bench 750mm desirable.
5. Check roof space above for wires and obstructions as now is the time to decide on any changes to
location due to immovable obstructions.
6. Mark flue size on ceiling and cut neat exact hole to pass flue through.
7. For rear ducted models cut hole in wall for vent to pass through.
8. Fix mounting bracket to wall at desired height.
9. Remove fan(s) from canopy by removing side fixing bolts and disconnecting electrical plug at flexible
connector.
10. Locate solid fixing points on wall and drill holes in rear of canopy to suit. If no solid fixing is available
then now is the time to install fixing points. Four points are recommended with one on each side at top and one on each side at bottom.
11. Drill hole in rear of unit to pass power connection through where available on wall.
12. Check flue slides through hole in ceiling.
13. Place canopy flat on floor and fit stainless flue over spigot pushing all the way down for a neat fit.
Drill hole in rear of flue and fix to canopy with pop rivet or screw.
14. Carefully lift canopy into position, guiding flue through ceiling and feeding power cable through hole
in rear of canopy. Make sure canopy is sitting correctly on mounting bracket then fix to wall through fixing holes with solid screws. (You may need to place a packer behind canopy if wall is bowed to make the canopy sit correctly).
15. Complete electrical connection to 10 AMP junction box to local electrical authority regulations
ensuring power is turned off during work.
16. Fit ducting to outside or exterior wall vent for rear ducted models. (Seal rear vents onto rear of hood
with silicone). A plumber should seal roof penetration with appropriate flashing. All joins in ducting need to be sealed with duct tape or silicone and only use approved ducting of the correct size for your canopy.
17. Fit motor(s) back into canopy with fixing bolts and plug electrical connector in.
18. Test run hood.
QASAIR Installation Instructions
15
Heritage Range – H
600HL-1 Top / Back ducted 700HL-1 Top / Back ducted 900HL-1 Top / Back ducted
Duct outlet dimension top ducted 240 x 106mm back duct 235 x 110mm
Standard single motor ducting will fit
It is recommended that the hood be positioned 700 to 800 above the cooktop. QASAIR suggests 750 and the DLE flues supplied are either 600/900/1200 or 1500 long. Please ensure you have the correct flue before installing the hood.
Heritage Range – H
1200HL-2 Top / Back ducted 1500HL-2 Top / Back ducted
Duct outlet dimension top ducted 370 x 150mm back duct 235 x 110mm
Standard 2 motor ducting will fit
It is recommended that the hood be positioned 700 to 800 above the cooktop. QASAIR suggests 750 and the DLE flues supplied are either 600/900/1200 or 1500 long. Please ensure you have the correct flue before installing the hood.
QASAIR Installation Instructions
16
Heritage Range – PYRAMID
PYR 900L Top / Back ducted
Duct outlet dimension 235 x 110mm
Standard single motor ducting will fit
QASAIR Installation Instructions
17
Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. Connection to be carried out by a registered electrician.
Flue fitting instructions 3 Flare Models Only
1. Check that the flue is the correct length prior to fitting.
2. Peel back PVC on the flue.
3. Place the rangehood on a level surface.
4. Remove the phillips head transit screws from the top of the rangehood.
5. Position the flue over the outlet and place all the rivets in the holes available and then fasten them.
6. Fit the flue back plate.
Installation instructions
1. Prepare wall by marking level line at desired height above cooktop.
2. Plumb line from centre of cooktop to ceiling and mark flue cut out. Position mounting bracket on wall
and fix with four screws. Mounting bracket is not necessary when installing over a splashback.
Note: The fixing bracket is 32mm shorter than the rangehood and should be located from the centre
only.
3. Cut a neat hole through the ceiling and remove any obstructing timbers.
Note: Various offsets are available from your QASAIR dealer to duct around any major structural
beams which cannot be removed. Ask your QASAIR dealer for advice.
4. In the case of back ducted models, cut a hole in the wall at the desired height.
5. Locate solid fixing point in wall to support hood. If there is no solid fixing point it will have to be
placed in the wall before proceeding. QASAIR recommend at least four (4) fixing points.
6. Drill holes in back of unit at suitable fixing points.
7. Drill 20mm hole in the rear of unit for 240 volt power cable as close as possible to junction box or
use hole below the junction box.
8. Place flue over spigot of hood then carefully lift into position on level line. Ensure flue is pushed into
position and electrical cable is fed into rear of unit.
9. Duct in approved manner to outside atmosphere.
Cleaning of Stainless Steel
QASAIR Rangehoods are made from stainless steel type 304 and is considered 18/8 SS.
This means the stainless steel is 18% chromium and 8% nickel in the mix. The steel becomes stainless by the chromium oxidising in the open air to form a protective coating of chromium oxide. This coating can be upset by coming in contact with a substance that will attack the chromium oxide, such as a lemon solution or any cleaner with a preservative in it.
Therefore, only clean the rangehood with an approved stainless steel cleaner. Methylated spirits or warm soapy water with soap will do it. Do not use powder detergent.
INSTRUCTIONS
for models
3F 900L-2
3F 1200L-2
3F1200L-3
3F 1500L-3
SF 900L-1
SF 900L-2
SF 1200L-2
ST 900L-1
ST 900L-2
ST 1200L-2
MAJ 900L-1
MAJ 900L-2
MAJ 1000L-2
MAJ 1200L-2
MAJ 1500L-2
IN 600L-1
IN 900L-2
IN 1200L-2
IN 1200L-3
STA 900L-2
STAR 900L-2
STA 1200L-2
STAR 1200L-2
SMF 600L-1
SMF 900L-1
SMF 900L-2
SMF 1000L-2
SMF 1200L-2
SMF 1500L-2
SMF 1500L-3
SMF 1800L-3
FAS 900L-2
FAS 1200L-2
QASAIR Installation Instructions
18
Federation Range – 3 FLARE
3F 900L-2 Top / Back ducted 3F 1200L-2 Top / Back ducted
Duct outlet dimensions: top ducted 300 x 180 and 400 x 180 back duct 250 x 250
Standard 2 motor ducting will fit
A transition piece is supplied to fit to the top of flue to suit 2 motor ducting
3F 1200L-3 Top / Back ducted 3F 1500L-3 Top / Back ducted
Duct outlet dimensions: top ducted 400 x 200 back duct 110 x 235 and 250 x 250
Standard 1 motor and 2 motor ducting will fit
Federation Range – SINGLE FLARE
SF 900L-1 Top / Back Ducted
Duct outlet dimension 240 x 110
Standard single motor ducting will fit
Top ducted model is supplied with a DLE S/S Flue
SF 900L-2 Top / Back Ducted SF 1200L-2 Top / Back Ducted
Duct outlet dimensions: top ducted 370 x 150 back ducted 250 x 250
Standard 2 motor ducting will fit
Top model is supplied with a DLE-2 S/S Flue
QASAIR Installation Instructions
19
Federation Range – STEP
ST 900L-1 Top / Back Ducted
Duct outlet dimension 235 x 110
Standard single motor ducting will fit
Top ducting model can have a DL-1 drop into the motor
ST 900L-2 Top / Back Ducted ST 1200L-2 Top / Back Ducted
Duct outlet dimensions: top duct 370 x 150 back duct 250 x 250
Standard 2 motor ducting will fit
Imperial Range – MAJESTIC
MAJ 900L-1 Top / Back Ducted
Duct outlet dimension 235 x 110mm
* For hoods shorter than 750mm high
this dimension varies to a minimum of 440mm
MAJ 900L-2 Top / Back Ducted MAJ 1000L-2 Top / Back Ducted MAJ 1200L-2 Top / Back Ducted MAJ 1500L-2 Top / Back Ducted
Duct outlet dimension 250 square
* For hoods shorter than 750mm high
this dimension varies to a minimum of 300mm
QASAIR Installation Instructions
20
Gallery Range – INTEGRA
IN 600L-1 Top / Back Ducted IN 900L-2 Top / Back Ducted IN 1200L-3 Top / Back Ducted
Duct outlet dimension 235 x 110mm
Standard single, twin or triple motor ducting will fit
Gallery Range – STATESMAN
STA 900L-2 Top / Back Ducted STAR 900L-2 Top / Back Ducted STA 1200L-2 Top / Back Ducted STAR 1200L-2 Top / Back Ducted
R – with rail
Duct outlet dimension 250 square
Standard twin motor ducting will fit
QASAIR Installation Instructions
21
Federation Range – MAITLAND
SMF 600L-1 Top / Back Ducted SMF 900L-1 Top / Back Ducted SMF 900L-2 Top / Back Ducted SMF 1000L-2 Top / Back Ducted
Duct outlet dimension 235 x 110
Standard single motor ducting will fit
Federation Range – MAITLAND
SMF 1200L-2 Top / Back Ducted SMF 1500L-2 Top / Back Ducted SMF 1500L-3 Top / Back Ducted SMF 1800L-3 Top / Back Ducted
Duct outlet dimension 235 x 110
Standard single motor ducting will fit
QASAIR Installation Instructions
22
Shroud
The dimensions are shown on the diagram. It is necessary to measure the height to the ceiling on each side of the motor box so we get
the exact measurement to make the shroud.
We will leave a 2mm gap to allow for any
variation in the ceiling or hood installation.
Imperial Range – FASANO
FAS 900L-2 Top Ducted FAS 1200L-2 Top Ducted
Duct outlet dimension 250 square
Standard twin motor ducting will fit
QASAIR Installation Instructions
23
The Thermidor rangehood is designed to be built into the ceiling.
Installation instructions
1. Remove hood from packaging being careful not to touch the stainless steel front.
2. Locate centre of stove and using level or plumb line, mark centre line up to the ceiling.
3. In a new house the hood can be fixed into the ceiling space by bolting or screwing into the ceiling
joists or by building a frame to support the hood.
4. In an existing home, a hole must be cut into the ceiling and pushing the hood into the space. Ensure
there are no obstructions to placing the hood in position. In these cases a ceiling flange in stainless can be supplied to finish the hood to the ceiling. It is not supplied in colours.
5. The outlets are either top or back ducted and can be changed on site and the hood can be reversed
to suit the intended ducting direction.
6. Once secure in position standard ducting pieces can be used.
7. Switches are not provided and remote switching in a convenient position must be installed. The
switching used must be an electrically approved switch and is not provided by Condari Pty Ltd.
INSTRUCTIONS
for models
TR CT 1000-3
TR CT 1200-3
TR CT 1500-3
TR CT FLANGE 1000
TR CT FLANGE 1200
TR CT FLANGE 1500
QASAIR Installation Instructions
24
Gallery Range – THERMIDOR
TR CT 1000-3 Top / Back Ducted TR CT 1200-3 Top / Back Ducted TR CT 1500-3 Top / Back Ducted
Duct outlet dimension 235 x 110mmw
Standard triple motor ducting will fit
TR CT FLANGE 1000 TR CT FLANGE 1200 TR CT FLANGE 1500
QASAIR Installation Instructions
25
Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. Connection to be carried out by a registered electrician.
Installation instructions
1. Remove hood from packaging being careful not to touch stainless steel front.
2. Locate centre of stove and using level or plumb line, mark centre line up to ceiling.
3. Measure height of hood and mark same distance down from ceiling with level line.
4. Mark where ducting needs to be cut either on wall or ceiling, check for wires and timber, then
cut hole for ducting.
5. Locate solid fixing points on wall (This hood is very heavy and requires good solid fixing
points). If necessary fit some solid fixing timber to wall behind hood now.
6. Mark fixing points on rear of hood and drill fixing holes to take solid screws.
7. Drill hole in rear or top of the hood to take electrical cable.
8. It may be easier to remove fans for easier fixing and weight when installing.
9. If you do not have adjustable stands you can cut some temporary timber props to sit canopy
on when you lift into position, to hold it while you fit fixing screws.
10. You need two people to lift this canopy into position. * Do not attempt this on your own, as
you could cause yourself injury and damage the hood or stove. CAUTION: Do not under any circumstances lift from the front of the hood or put any pressure on the front face as you will damage the hood permanently.
11. Carefully lift hood into position and sit on stands to level hood, then screw hood into position
through fixing holes. Make sure you put fixing holes high up in the hood to stop it falling forward.
12. Fit ducting to hood to the outside atmosphere as required either through the roof with
appropriate flashing by a plumber or through the rear wall vent, which needs to be siliconed to the rear of the hood. Always use approved ducting and seal all duct joins with duct tape or silicone.
13. An electrician should make the electrical connection to the hood by connecting to the 10 AMP
junction box. Ensure power is turned off during this procedure.
14. Refit fans to hood, insert filters and test.
Handy hints: Sometimes it is easier to lift the hood with a person in the roof space pulling up on a
rope attached to a wooden block placed inside base of hood and a second person down the bottom guiding the hood into position.
Cleaning of Stainless Steel
QASAIR Rangehoods are made from stainless steel type 304 and is considered 18/8 SS.
This means the stainless steel is 18% chromium and 8% nickel in the mix. The steel becomes stainless by the chromium oxidising in the open air to form a protective coating of chromium oxide. This coating can be upset by coming in contact with a substance that will attack the chromium oxide, such as a lemon solution or any cleaner with a preservative in it.
Therefore, only clean the rangehood with an approved stainless steel cleaner. Methylated spirits or warm soapy water with soap will do it. Do not use powder detergent.
INSTRUCTIONS
for models
BRH 600L-1
BRH 900L-1
BRH 900L-2
BRH 1000L-2
BRH 1200L-2
BAR 1800L-2
BAR 2400L-2
QASAIR Installation Instructions
26
Argyle Range – BENTON
BRH 600L-1 Top / Back Ducted BRH 900L-1 Top / Back Ducted BRH 900L-2 Top / Back Ducted BRH 1000L-2 Top / Back Ducted BRH 1200L-2 Top / Back Ducted
Duct outlets dimensions: single – duct 235 x 110mm twin – duct 250 square
Standard single motor ducting will fit or 250sq for twin motor
Gallery Range – BARCLAY
BAR 1800/9L-2 Top / Back Ducted BAR 2400/9L-2 Top / Back Ducted BAR 2400/10L-2 Top / Back Ducted BAR 2400/12L-2 Top / Back Ducted
Duct outlets dimensions: single – duct 235 x 110mm twin – duct 250 square
Standard single motor ducting will fit or 250sq for twin motor
QASAIR Installation Instructions
27
Installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: Wiring to the appliance must comply with State and local Regulations. Connection to be carried out by a registered electrician.
Installation instructions
It is recommended that the rangehood be mounted 100mm back from the edge of the benchtop.
1. The rangehood can be installed between 700mm and 800mm above the cooking surface. The
installer should check for local requirements in case additional provisions apply.
2. It is advisable to remove fans for easier handling of unit by removing retaining bolts or clips and
unplugging electrical connector.
3. Measure hole centres and duct size on top of the rangehood. This will vary with the hood size,
model and number of fans fitted and will determine the ducting required.
4. Using a plumb line, mark the ceiling before making the cut out. Check for obstructions like electrical
cables etc.
5. Cut two (2) supporting beams approximately 1.0m long and pre-drill hole centres so that the
supporting beams are 90 degrees to the ceiling joists.
6. Fit 8mm all thread (threaded rod) through holes provided and secure with nuts and washers.
7. Level unit by tensioning the 8mm nuts. Do not over tighten.
8. Fit off ducting as required.
Cleaning of Stainless Steel
QASAIR Rangehoods are made from stainless steel type 304 and is considered 18/8 SS.
This means the stainless steel is 18% chromium and 8% nickel in the mix. The steel becomes stainless by the chromium oxidising in the open air to form a protective coating of chromium oxide. This coating can be upset by coming in contact with a substance that will attack the chromium oxide, such as a lemon solution or any cleaner with a preservative in it.
Therefore, only clean the rangehood with an approved stainless steel cleaner. Methylated spirits or warm soapy water with soap will do it. Do not use powder detergent.
INSTRUCTIONS
for models
Island Rangehoods
4F 900L-2 4F 1200L-2 VIS 900L-2 VIS 1200L-2 VIS 1200L-3 VIS 1500L-3 PRE 900L-2 PRE 1200L-2 PRE 1500L-2 PRE 1500L-3 PRE 1800L-3 D 400-L1 D 500L-2 SQ 420-L2 FPRL-2 MA 2000-2500L-4 MA 2500-3000L-4 HAM 900L-2 HAM 1200L-2 BUR 900L-2 BUR 1000L-2 BUR 1200L-2 BUR 1200L-3 BUR 1500L-2 BUR 1500L-3
QASAIR Installation Instructions
28
Island hood fixing – for flat, cathedral and exposed beam roofs.
QASAIR Installation Instructions
29
Imperial Range – VISCOUNT
VIS 900L-2 Island Hood VIS 1200L-2 Island Hood VIS 1200L-3 Island Hood VIS 1500L-3 Island Hood
Duct outlet dimensions: twin – duct 300 x 165mm triple – duct 400 x 200mm
Standard 3 motor ducting will fit
Transition piece supplied with Hood to DL-2 ducting
Federation Range – 4 FLARE
4F 900L-2 Island Hood 4F 1200L-2 Island Hood
Duct outlet dimension 265 x 90mm and 300 x 90mm
Standard 3 motor ducting will fit
QASAIR Installation Instructions
30
Imperial Range – PRESIDENT
PRE 900L-2 Island Hood PRE 1200L-2 Island Hood
Duct outlet dimension 250 x 250mm
Standard 250 sq ducting will fit
Imperial Range – PRESIDENT
PRE 1500L-2 Island Hood PRE 1500L-3 Island Hood PRE 1800L-3 Island Hood
Duct outlet dimension 250 x 250mm
Standard 250 sq ducting will fit
QASAIR Installation Instructions
31
Argyle Range – ALBANY
D 400L-1 Island Hood
Duct outlet dimension 110 x 235mm
Standard DL-1 ducting will fit
Argyle Range – ALBANY
D 500L-2 Island Hood
Duct outlet dimension 250 square
QASAIR Installation Instructions
32
Argyle Range – WINTON
SQ 420L-2 Island Hood
Duct outlet dimension 250sq
Standard 250mm ducting will fit
Argyle Range – BURDETT
BUR 900L-2 Island Hood BUR 1000L-2 Island Hood BUR 1200L-2 Island Hood BUR 1200L-3 Island Hood BUR 1500L-2 Island Hood BUR 1500L-3 Island Hood
Duct outlets dimensions: twin – duct 250 square triple – duct 200 x 400mm
Standard single motor ducting will fit or 250sq for twin motor
QASAIR Installation Instructions
33
Gallery Range – MADDISON
MA 2000-2500L-4 Island Hood MA 2500-3000L-4 Island Hood
Duct outlet dimension 250sq
Standard four motor ducting will fit or
Imperial Range – HAMILTON
BUR 900L-2 Island Hood BUR 1200L-2 Island Hood
Duct outlets dimension 250 square
Standard single motor ducting will fit or 250sq for twin motor
QASAIR Installation Instructions
34
Argyle Range – FREMONT
FPRL-2 Island Hood
Duct outlet dimension 250sq
Standard 250mm ducting will fit
QASAIR Installation Instructions
35
Special Rangehoods are hoods made to specific designs and not covered by the instructions in this booklet for standard hoods, although the basic rules will still apply.
Generally, special rangehoods are either wall or ceiling mounted and therefore are installed in the same manner as the rangehoods in the previous pages.
Standard ducting will apply unless special ducting is supplied with the hood.
If any doubt arises, please ring your local agent or Melbourne office on (03) 9482 7088 or 1300 360 563.
Cleaning of Stainless Steel
QASAIR Rangehoods are made from stainless steel type 304 and is considered 18/8 SS.
This means the stainless steel is 18% chromium and 8% nickel in the mix. The steel becomes stainless by the chromium oxidising in the open air to form a protective coating of chromium oxide. This coating can be upset by coming in contact with a substance that will attack the chromium oxide, such as a lemon solution or any cleaner with a preservative in it.
Therefore, only clean the rangehood with an approved stainless steel cleaner. Methylated spirits or warm soapy water with soap will do it. Do not use powder detergent.
INSTRUCTIONS
for models
Special Rangehoods
QASAIR Installation Instructions
36
LAMP
replacement
and
FILTER care
QASAIR rangehoods are fitted with low voltage halogen lights which give a very clear, bright light. These become very hot if left on for a long period and can burn out. Please switch off after use.
1. Turn off power at power point. 2 Turn retaining ring anticlockwise and pull down.
3. Tilt lamp up slightly at retaining spring opening position and slide lamp out sideways.
4. Unplug lamp from the ceramic connector and replace lamp.
5. If retaining ring will not rotate, dislodge lamp by gently pushing upwards to obtain a
better grip.
ROTATE ANTI CLOCKWISE TO REMOVE
Filters
For the best results, please clean filters regularly, you can do this by hand washing or placing in the dishwasher. Try not to use any citrus or costic products as this can cause corrosion.
QASAIR Installation Instructions
37
101. DL-1 Duct Length 1200mm DL-1C Duct Length (coloured)
103. HB-1-45 Horizontal Bend 45º
102. HB-1 Horizontal Bend 90º
104. BD/WV-H-1 Back Draft Wall Vent Horizontal
DUCTING
pieces
Single Motor
Twin Motor
Triple Motor
The following pages show all the ducting pieces available. They are made in zinc-alume and are non­flammable. We recommend that QASAIR rangehoods are ducted to the outside atmosphere by these duct pieces. QASAIR will make special duct pieces on request if circumstances prevent the use of standard pieces.
‹‹ Single Motor
101. DL-1E Duct Length Extenable 1200mm
101. DL-1A Duct Length 300mm
QASAIR Installation Instructions
38
105. BD/WV-H-1 MGS Back Draft Wall Vent Horizontal Marine Grade Stainless Steel
108. BD/WV-V-1 Back Draft Wall Vent Vertical
111. TT-1 Twisted Transition
106. VB-1 Vertical Bend 90º
109. BD/WV-V-1 MGS Back Draft Wall Vent
Vertical Marine Grade Stainless Steel
112. DLE-DLE Flue Joiner
107. VB-1-45 Vertical Bend 45º
110. DD-1-L/R Duct Director Left or Right
113. CD-920 Cavity Duct Extendable
‹‹ Single Motor
114. CD-920 to DL-1 Duct to Duct Length 115. TR-1 Rectangular to Round Transition
116. DR-200 Duct Length 1200mm
QASAIR Installation Instructions
39
‹‹ Single Motor
117. DR-200 CB Duct Length 1200mm Colourbond
120. BD-6/7/9-WV-R/R Rear Registar Kit
118. DR-200/45 Round Bend 45º
121. AS-20 Back Draft Shutter
119. DR-200/90 Round Bend 90º
122. CH-200 Chairman's Hat 200ø
123. CH-200 CB Chairman's Hat Colourbond
126. BD/SQ-RC 200 Back Draft Roof Cowl 200ø
124. BD/RC-1 Back Draft Roof Cowl
127. DLE-S/S CAP Stainless Steel Flue Cap
125. BD/RC-1 CB Back Draft Roof Cowl
Colourbond
128. BD/M-1 Back Draft Damper
QASAIR Installation Instructions
40
‹‹ Single Motor
132. WVC-V-1 Wall Vent Cover Vertical
135. EV/DL-1 Eave Vent Suit DL-1
138. HB-195/45 Horizontal Bend 45º
133. WVC-V-1 MGS Wall Vent Cover Vertical
Marine Grade Stainless Steel
136. DL-195 Duct Length
139. BD/WV-195SQ Back Draft Wall Vent
Square
134. 6/7/900H-SC Spigot Cap
137. HB-195 Horizontal Bend 90º
140. BD/RC-195SQ Back Draft Roof Cowl Sqaure
129. CF-6/7/900H Ceiling Flange 6/7/900H 130. WVC-H-1 Wall Vent Cover Horizontal 131. WVC-H-1 MGS Wall Vent Cover Horizontal
Marine Grade Stainless Steel
QASAIR Installation Instructions
41
‹‹ Single Motor
141. WVC-6/7/9H-R/R Wall Vent Cover
142. WVC-195SQ Wall Vent Cover
143. RCP-200 S/S Roof Cap 200ø
Stainless Steel
144. RC-200 S/S Roof Cowl 200ø Stainless Steel
145. RC-200 Zinc Roof Cowl 200ø Zinc Alumne
146. RC-1 S/S Roof Cowl Single Motor
Stainless Steel
QASAIR Installation Instructions
42
201. TMT Twin Motor Transition
204. HB-2/45 Horizontal Bend 45º
207. VB-2 Vertical Bend 90º
202. DL-2 Duct Length 1200mm
205. BD/WV-H-2 Back Draft Wall Vent
208. VB-2/45 Vertical Bend 45º
203. HB-2 Horizontal Bend 90º
206. BD/WV-H-2 MGS Back Draft Wall Vent
Marine Grade Stainless Steel
209. BD/WV-V-2 Back Draft Wall Vent
‹‹ Twin Motor
210. BD/WV-V-2 MGS Back Draft Wall Vent Marine Grade Stainless Steel
211. TT-2 Twisted Transition 212. DLE-2 to DLE-2 Flue Joiner
QASAIR Installation Instructions
43
‹‹ Twin Motor
213. BD10/12/15-WV-R/R Rear Register Kit
216. DR-300 Duct Length 300ø 1200mm
214. TMT-300 Transsition to 300ø
217. DR-300 CB Duct Length 300ø 1200mm
Colourbond
215. TR-2 Transition from DL-2 to 300ø
218. DR-300/45 Round Bend 45º
219. DR-300/90 Round Bend 90º
222. TMT-250 Twin Motor to 250sq
220. DL-2 /250SQ Rectangular to Square
Transition
223. DL-250 Duct Length 1200mm
221. TMT-250/300 Transition from 250sq
to 300º
224. HB-250 Horizontal Bend 90º
QASAIR Installation Instructions
44
225. HB-250/45 Horizontal Bend 45º
226. TMT-250/90 Duct Deflector 250sq
Left or Right
227. BD/WV-250SQ Back Draft Wall 250sq
‹‹ Twin Motor
228. BD/WV-250SQ MGS Back Draft Wall 250sq Marine Grade Stainless Steel
231. CH-300 Chairman's Hat 300º
234. BD/RC-250SQ Back Draft Roof Cowl 250sq
229. BD/RC-2 Back Draft Roof Cowl
232. CH-300 CB Chairman's Hat 300º Colourbond
235. DLE-2-S/S CAP Flue Cap
230. BD/RC-2 CB Back Draft Roof Cowl
Colourbond
233. BD/SQ-RC-300 Back Draft Roof Cowl 300ø
236. CF-10/12/1500H Ceiling Flange
10/12/1500H
QASAIR Installation Instructions
45
237. CF-3F900-2 Ceiling Flange 3F900-2
240. CF-4F1200-2 Ceiling Flange 4F1200-2
243. WVC-V-2 Wall Vent Cover Vertical
238. CF-3F1200-2 Ceiling Flange 3F1200-2
241. WVC-H-2 Wall Vent Cover Horizontal
244. WVC-V-2 MGS Wall Vent Cover Vertical
Marine Grade Stainless Steel
239. CF-4F900-2 Ceiling Flange 4F900-2
242. WVC-H-2 MGS Wall Vent Cover Horizontal
Marine Grade Stainless Steel
245. WVC-250SQ Wall Vent Cover 250sq
247. WVC10/12/15H-R/R Wall Vent Cover
10/12/1500H
248. 10/12/1500H-SC Spigot Cap
246. WVC-250SQ MGS Wall Vent Cover 250sq
Marine Grade Stainless Steel
‹‹ Twin Motor
QASAIR Installation Instructions
46
‹‹ Twin Motor
255. CF 3F-1500-2 Ceiling Flange 3F-1500-2
252. BD/M-250SQ Back Draft Damper 250sq
249. DD-2H-L/R Duct Director Horizontal
Left or Right
253. AS-25 Back Draft Shutter
250. DD-2V-L/R Duct Director Vertical
Left or Right
254. BD/WVC-SBS Back Draft Wall Vent Cover
251. EV/DL-2 Eave Vent to Suit DL-2
256. RCP-300 S/S Roof Cap 300ø
Stainless Steel
257. RV-300 S/S Roof Ventilation Cowl 300ø Stainless Steel
258. RC-300 S/S Roof Cowl 300ø Stainless Steel 259. RC-2 S/S Roof Cowl Twin Motor
Stainless Steel
QASAIR Installation Instructions
47
306. VB-3/45 Vertical Bend 45º
309. TR-3 Transition to 350ø
308. TMT-400x200/350 Transition from DL-3
to 350ø
307. TT-3 Twisted Transition
304. HB-3/45 Horizontal Bend 45º
305. VB-3 Vertical Bend 90º
301. 3MT-DL-3 Three Motor Transition
302. DL-3 Duct Length 1200mm
303. HB-3 Horizontal Bend 90º
‹‹ Triple Motor
312. DR-350/45 Bend 45º 350ø
311. DR-350 CB Duct Length 350ø Colourbond
310. DR-350 Duct Length 350ø
QASAIR Installation Instructions
48
318. CH-350 Chairman's Hat 350ø
317. BD/SQ-RC350 MGS Back Draft Roof Cowl
350ø Marine Grade Stainless Steel
313. DR-350/90 Bend 90ø 350ø
314. BD/RC-3 Back Draft Roof Cowl
315.BD/RC-3 MGS Back Draft Roof Cowl
Marine Grade Stainless Steel
316. BD/SQ-RC350 Back Draft Roof Cowl 350ø
‹‹ Triple Motor
322. BD/WV-V-3 Back Draft Wall Vent Vertical
323. BD/WV-V-3 MGS Back Draft Wall Vent
Vertical Marine Grade Stainless Steel
324. WVC-H-3 Wall Vent Cover Horizontal
320. BD/WV-H-3 Back Draft Wall Vent
Horizontal
321. BD/WV-H-3 MGS Back Draft Wall Vent Horizontal Marine Grade Stainless Steel
319. CH-350 CB Chairman's Hat 350ø Colourbond
QASAIR Installation Instructions
49
327. WVC-V-3 MGS Wall Vent Cover Vertical Marine Grade Stainless Steel
326. WVC-V-3 Wall Vent Cover Vertical
325. WVC-H-3 MGS Wall Vent Cover Horizontal
Marine Grade Stainless Steel
‹‹ Triple Motor
330. AS-35 Back Draft Shutter
329. DD-3V-R Duct Director Vertical Right328. DD-3V-L Duct Director Vertical Left
QASAIR Installation Instructions
50
1. FA 60-1B
2. FA 90-1T
INSTALLATION
ideas
3. FA 60-1T
QASAIR Installation Instructions
51
5. FA 60-1T
4. FA 60-1T
6. FA 60-1T / 60-1B
7. FA 90-2T
8. FA 90-2T 9. FA 90-2T
QASAIR Installation Instructions
52
12. FA 90-2T
11. FA 90-2T
14. 600H-T
13. 600H-T / 700H-T / 900H-T
15. UCH 50-1T
10. FA 90-2B
QASAIR Installation Instructions
53
16. UCH 80-1T
18. UCH 80-2T
17. UCH 50-1T
19. 1200H-T
20. UV 800-2T 21. UV 1000-2T
QASAIR Installation Instructions
54
22. 3F 900-2T / 1200 -2T
24. UV 800-1T
23. UV 500-1T
26. UV 1200-2B
25. UCH 80-1T / UV 1000-2T
QASAIR Installation Instructions
55
There are some exclusions from the Condari Pty Ltd Guarantee. The Guarantee is printed at the back of brochure.
QASAIR Rangehoods are designed to be used over all domestic cookware available in AUSTRALIA.
QASAIR Rangehoods are not to be used over barbecues approved for outdoor use only.
Outdoor barbecues will have a rating plate on them specifying that they are approved for outdoor use only and also a mega joule rating per burner or a total mega joule rating.
In practice any barbecue or outdoor cooking appliance over 50 mega joule will need a specially made rangehood with an air movement exceeding 2000 cubic meters per hour.
QASAIR have hoods to go over domestic cookers such as VIKING, WOLF and CAPITAL cooking appliances. These brands have a mega joule rating of up to 95 mj and therefore special hoods are required for the appliances.
QASAIR will manufacture special rangehoods to go over commercial cooking appliances situated in domestic kitchens.
Once the heat output is over 50 mega joule a special rangehood is required.
QASAIR Installation Instructions
56
NOTES _____________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
_____________________________
QASAIR Installation Instructions
57
NOTES _____________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
_____________________________
QASAIR Installation Instructions
58
NOTES _____________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
__________________________________
_____________________________
STANDARD
WARRANTY
Condari P/L Appliance Guarantee
The benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product which the consumer has under the Trade Practices Act and similar state and territory laws.
Condari P/L in Melbourne (and by their agency in Country Areas and other States) warrants that the appliance will be free from defects in materials and workmanship for a period of 36 months from the date of purchase of the appliance to the consumer.
If there is a breach of this warranty, Condari will rectify, free of charge, at it's nearest service centre or authorised service agency any fault caused by faulty workmanship or material at the time of manufacture occurring in the appliance within 36 months from the date of delivery of the appliance to the customer.
This warranty is conditional upon the appliance being used only for personal, domestic and household purposes and installed and operated in accordance with QASAIR Instructions and does not apply to articles which by their nature are consumable.
If a defect is caused by neglect, misuse, or failure to follow operating instructions where special precautions are detailed for user attention then a charge shall be made for the service call.
For example: With the filters the user is specifically requested:
To clean filter regularly by handwashing or placing in a dishwasher at least once a month.
To turn off after each use.
Where a claim is made under warranty QASAIR reserves the right to determine whether or not the fault is caused by faulty workmanship or material or that the part is defective.
The consumer shall be fully responsible for all expenses whatsoever incidental to the removal of parts from the unit or to their replacement. Interalia, such responsibility shall extend to damaged walls, tiles, fixtures and fittings whether or not the unit has been built into a cupboard and irrespective of the stage either of its installation or the fitting of any other item whatsoever in its vicinity.
No other person, or firm or corporation is authorised by Condari to offer or give on its behalf any other greater warranty that given by Condari under this warranty.
Date installed ..................................
Purchased from ................................
Model ........................................
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial No .....................................
The purchaser must fill in the above information and keep this with the original purchase document. This form must be produced if and when a claim is made under this warranty.
QASAIR Rangehoods are made in Ringwood, Australia.
Tel: +61 3 9482 7088
Fax: +61 3 9482 7011
QASAIR RANGEHOODS MADE IN RINGWOOD 3134
QASAIR RESERVES THE RIGHT TO CHANGE SPECIFICATION WITHOUT NOTICE. ® IS A REGISTERED TRADE MARK.
DISTRIBUTED IN AUSTRALIA BY CONDARI PTY LTD
Tel: 1300 360 563 VIC Tel: +61 3 9482 7088 Fax: +61 3 9482 7011 Email: sales@qasair.com.au Website: www.qasair.com.au
YOUR DISTRIBUTORS
Australia
NSW Te l: +61 2 9316 4599 Fax: +61 2 9316 9299 QLD Tel: +61 7 3423 3503 Fax: +61 7 3282 9122 WA Te l : +61 8 9381 1188 Fax: +61 8 9381 6000 SA Tel: 0419 109 256 Fax: +61 8 8449 6973 ACT Te l: +61 2 6239 2877 Fax: +61 2 6239 2750 TAS Tel: +61 3 6231 6633 Fax: +61 3 6231 6662 NT Tel: +61 8 8947 3444 Fax: +61 8 8947 0419
New Zealand
Kitchen Appliance Specialist Ltd
320 Manchester Street
Christchurch New Zealand
Tel: +64 3 379 0360 Fax: +64 3 365 5623
Kouzina Appliances
155 The Strand, Parnell
Auckland New Zealand
Tel: +64 9 377 7822 Fax: +64 9 377 7824
Singapore
Eldric Marketing Pte Ltd
176 Orchard Road
#05-03 Centrepoint Singapore 238843
Tel: +65 6339 1168 Fax: +65 6733 8133
5 Pereira Road
#02-01 Asiawide Industrial Building
Singapore 238843
Tel: +65 6743 8388 Fax: +65 6743 0202
07/12
PRINTED IN MELBOURNE AUSTRALIA
Loading...