Qasair SEA1200L2B, SEA1200L2T, CM600L1T, SEA900L1B, SEA900L1T Installation Guide

...
0 (0)
WALL MOUNT
INSTALLATION & USER
INSTRUCTIONS
Qasair Rangehoods Installation Instructions2
Qasair Rangehoods Installation Instructions
3
Standard Warranty / Extended Warranty
Important Information
H Series & PYR
3F / SEA / SMF / CM / STA / STF / IN
BRH / LAM / BAR / MAR / MAJ / FAS
Installation Ideas
Operation Details, Rangehood Cleaning, Filter Cleaning
Ducting Pieces
Remote Switching Specications
Appliance Guarantee
Guarantee Exclusions
6
4
10
28
39
42
54
59
62
61
60
Qasair Rangehoods Installation Instructions4
The installation of QASAIR Rangehoods must comply with the information in this booklet. QASAIR Rangehoods are
designed and made to work efciently over all domestic cookware available on the Australian market.
Clearance from cooktop to Rangehood
For electric hot plate cooktops
As there are no regulations for Rangehoods over an electric hot plate, please follow the manufacturers Instructions /
Recommendations.
For Induction cooktops
Induction cooktops may present problems with condensation on lters of Rangehoods.
All Qasair Rangehoods installed above an induction cooktop must be installed no less than 750mm between the
induction cooktop and the Rangehood, with the exception of the Eastmore (EAS) Rangehood which can be installed
no less than 600mm. Undermount (NDCH) and Conley (CON) Rangehoods are not suitable for induction cooktops.
For gas cooktops
All Qasair Rangehood installations over a gas appliance must comply with (AS/NZS 5601.1).
The Regulations for the installation of Gas Appliances (AS/NZS 5601.1) states that the clearance between the
highest part of the burner of a gas cooking appliance and a Rangehood be no less than 600mm. If the gas
appliance is designed for use without a cooking vessel like an indoor barbecue or open ame grill, then the
clearance from the cooking surface to the Rangehood shall be no less than 1200mm.
All Qasair Rangehoods installed above a gas cooktop must be installed no less than 600mm between the highest
part of the burner and the Rangehood.
The recommendation for Qasair Wallmount Rangehoods is that they be installed between 700 to 800mm above the
highest part of the burner. When the Rangehood is installed in a galley or partially enclosed kitchen the Rangehood
can be installed between 900 to 1000mm above the highest part of the burner.
Qasair Island Rangehoods should not be installed any higher than 800mm above the highest part of the burner as
any movement around the bench will result in fumes being drawn out from the catchment area of the Rangehood
with the exception of the Thermidor and Liverpool which for aesthetic reasons is installed ush with the ceiling.
Ducting
1. Every QASAIR Rangehood must be ducted to the outside atmosphere by the use of zinc-alume duct or
non-porous and non-ammable materials. Do not use of any type of exible ducting or plastic PVC piping.
Rangehoods must not be vented into a wall cavity or a ceiling space. Externally ducting the rangehood prevents
a build up of grease, which can be a re risk. Ensure the external outlet vent does not restrict the airow in any
way, as this may result in reduced performance.
2. QASAIR Rangehoods must be ducted in duct work equivalent to the outlet of the rangehood ie: The cross
sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have
sharp bends. Enlarge the duct size if the duct is to run 6 metres or longer. Advice from CONDARI is available to
ensure optimum performance. Always use nonammable materials to minimise the risk of re in the duct.
3. Ensure all ducting pieces are correctly tted and sealed with either duct tape or silicone to ensure that fumes
do not escape into the ceiling space and seep into living areas through vents or light ttings.
IMPORTANT INFORMATION
Qasair Rangehoods Installation Instructions
5
Other Important Information
1. Always adequately ventilate the room when the rangehood is in use at the same time as appliances
burning gas or other fuels.
2. WARNING: Incorrect venting will result in additional noise and a reduction in efciency. Exhaust air must not be
discharged into any chimney or ue, which may carry combustible products from other sources.
a) Do not discharge the air-ow from the rangehood into a ue used for exhausting fumes
from burning gas or fuel;
b) For cleaning purposes please refer to page 59 of installation instructions for stainless steel;
c) If cleaning is not carried out in accordance with the instructions as listed on page 59, there may be an
increased risk of re;
d) Some parts of the rangehood may become hot when cooking;
e) This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety.
3. The installation and tting of the rangehood should be done in such a way that will allow the unit to be removed
if service is required. Additional costs incurred in the removal of wall tiles, damage to walls or bench tops are not
covered by warranty.
4. To reduce the risk of xing screws coming in contact with live parts, do not drill or screw into the rangehood.
Live wires are encapsulated where possible to prevent user contact. If necessary drill from the inside out and
only through single sheet material.
5. NOTE: CONDARI recommend an air movement of between 1000 to 1400 cubic metres per hour over an indoor
barbecue, depending on the length of the duct run. Ensure a twin motor unit is installed over indoor barbecues
for optimum results. Barbecues should be positioned under the centre of the hood where the fans are mounted
and not near the outer edges where leakage may occur.
6. The lights in the rangehoods are LED and come with a night light except for D400L-1 and SEN400L-1.
7. If the supply cord is damaged, an authorised service centre or licensed electrician must replace it.
8. Do not ambé under the rangehood.
9. QASAIR domestic rangehoods must not to be used over barbecues approved for outdoor use only,
CONDARI make a range of hoods specically for outdoor barbecues in alfresco areas under the CONDOR
name.
10. CONDARI can manufacture rangehoods to be used over commercial cookers in domestic applications.
12. NOTE: Ensure all requirements are met with gas and electrical regulations and or state authorities.
Qasair Rangehoods Installation Instructions6
INSTALLATION INSTRUCTIONS
• H SERIES
• PYR
1. Remove canopy and flue from boxes and check you have correct model and flue.
2. Locate centre point of cooktop.
3. Use level or plumb line to mark centre up to ceiling.
4. Mark level line for base of canopy 700-800mm above bench 750mm desirable.
5. Check roof space above for wires and obstructions as now is the time to decide on any changes to location due
to immovable obstructions.
6. Mark flue size on ceiling and cut neat exact hole to pass flue through.
7. For rear ducted models cut hole in wall for vent to pass through.
8. Fix mounting bracket to wall at desired height.
9. Remove fan(s) from canopy by removing side fixing bolts and disconnecting electrical plug at flexible connector.
10. Locate solid fixing points on wall and drill holes in rear of canopy to suit. If no solid fixing is available then now is
the time to install fixing points. Four points are recommended with one on each side at top and one on each side
at bottom.
11. Drill hole in rear of unit to pass power connection through where available on wall.
12. Check flue slides through hole in ceiling.
13. Place canopy flat on floor and fit stainless flue over spigot pushing all the way down for a neat fit. Drill hole in
rear of flue and fix to canopy with pop rivet or screw.
14. Carefully lift canopy into position, guiding flue through ceiling and feeding power cable through hole in rear of
canopy. Make sure canopy is sitting correctly on mounting bracket then fix to wall through fixing holes with solid
screws. (You may need to place a packer behind canopy if wall is bowed to make the canopy sit correctly).
15. Complete electrical connection to 10 AMP junction box to local electrical authority regulations ensuring power is
turned off during work.
16. Fit ducting to outside or exterior wall vent for rear ducted models. (Seal rear vents onto rear of hood with
silicone). A plumber should seal roof penetration with appropriate flashing. All joins in ducting need to be sealed
with duct tape or silicone and only use approved ducting of the correct size for your canopy.
17. Fit motor(s) back into canopy with fixing bolts and plug electrical connector in.
18. Test run hood.
MOUNTING BRACKET
Use vertically punched slot for centre line
Before cutting any holes check ceiling space for structural beams. It may be possible at this point to relocate the
hood position.
The fixing points are prepunched holes in the back of the hood and it may be necessary to drill through the back
of the hood into the wall stud.
Recommended xing points
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
Qasair Rangehoods Installation Instructions
7
Heritage
Technical Specification Sheet
H
Wall Mounted
3
310mm
Power Entry Vertical
Light Centres
Light Qty
600mm
600HL-1
LED Light
Conversion
Top/Back Back/Top
Nightlight
2
Condari Pty Ltd.
Filter Qty
2
Motor Qty
Motor Box /
Flue Width
150mm
Version: C 20/01/2015F
Body Width
Model 600HL-1
Page 1 of 2
Filter Size
272mm
x
3
5
5
m
m
NO
700HL-1
Square Square
130mm
900HL-1
N/A
YES
125mm
Power Entry Horizontal
PowderKote
Available
Corner Type
Electrical Connection
YES
Outlet Spacing
900mm
240mm
Cool
11
700HL-1
Cool
510mm
22
310mm
YES
Junction Box
NO
Junction Box
135mm 210mm
NO
YES
Square
N/A N/A
272mm
x
3
5
5
m
m
290mm
x
3
5
5
m
m
150mm
Junction Box
Model900HL-1
YESYES
1
240mm
Cool
240mm
700mm
2
5
0
0
3
0
0
1
5
0
1
1
0
A
v
a
i
l
a
b
l
e
L
e
n
g
t
h
s
:
D
L
E
6
0
0
m
m
D
L
E
9
0
0
m
m
D
L
E
1
2
0
0
m
m
D
L
E
1
5
0
0
m
m
1
0
6
3
0
M
i
n
i
m
u
m
H
e
i
g
h
t
:
3
0
0
m
m
M
a
x
i
m
u
m
H
e
i
g
h
t
:
1
8
0
0
m
m
HERITAGE - H
Qasair Rangehoods Installation Instructions8
Heritage
Technical Specification Sheet
H
Wall Mounted
YES
2
816mm
2
370mm
Cool
Model1500HL-2
1500mm1200mm
370mm
1200HL-2
YES
Cool
2
Power Entry Vertical
648mm
22
Cool
370mm
2
YES
5
Outlet Spacing
Model
Body Width
Motor Box /
Flue Width
Motor Qty
LED Light
4
1000HL-2
1000mm
510mm
3
Nightlight
Light Qty
Light Centres
Filter Qty
Junction Box
215mm
375mm
YES
272mm
x
3
5
5
m
m
272mm
x
3
5
5
m
m
1500HL-2
NO
1200HL-2
YES
150mm
Square
Version: C 20/01/2015F
Square
75mm
290mm
x
3
5
5
m
m
1000HL-2
Junction Box
130mm
100mm
NO
Square
Page 2 of 2
Junction Box
NO
250mm
YES
190mm
100mm
Condari Pty Ltd.
PowderKote
Available
Corner Type
Electrical Connection
Power Entry Horizontal
Filter Size
Conversion
Top/Back Back/Top
5
0
0
3
0
1
5
0
1
1
0
3
7
5
A
v
a
i
l
a
b
l
e
L
e
n
g
t
h
s
:
D
L
E
-
2
6
0
0
m
m
D
L
E
-
2
9
0
0
m
m
D
L
E
-
2
1
2
0
0
m
m
D
L
E
-
2
1
5
0
0
m
m
1
5
0
M
i
n
i
m
u
m
H
e
i
g
h
t
:
3
7
5
m
m
M
a
x
i
m
u
m
H
e
i
g
h
t
:
1
8
7
5
m
m
HERITAGE - H
Qasair Rangehoods Installation Instructions
9
Pyramid
Technical Specification Sheet
PYR
Wall Mounted
Conversion
Top/Back Back/Top
Filter Size
Model
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Page 1 of 1
Corner Type
N/A
Filter Qty
3
Motor Qty
Light Qty
Light Centres
Motor Box /
Flue Width
Body Width
Model
Cool
YES
2
PYR 900L-1
1
900mm
270mm
510mm
LED Light
Nightlight
Condari Pty Ltd.
Junction Box
PYR 900L-1
Square
Version: B 20/01/2015F
NO
N/A
N/A
N/A
272mm
x
3
5
5
m
m
5
0
0
3
8
0
1
5
0
1
1
0
3
0
P
o
w
e
r
E
n
t
r
y
2
8
0
A
v
a
i
l
a
b
l
e
L
e
n
g
t
h
s
:
D
L
P
6
0
0
m
m
D
L
P
9
0
0
m
m
D
L
P
1
2
0
0
m
m
D
L
P
1
5
0
0
m
m
2
0
1
1
0
5
0
0
3
0
2
3
0
PYRAMID - PYR
Qasair Rangehoods Installation Instructions10
INSTALLATION INSTRUCTIONS
• 3F
• SEA
• SMF
• CM
• STA / STF
• IN (REMOTE SWITCHED)
1. Prepare wall by marking level line at desired height above cooktop.
2. Plumb line from centre of cooktop to ceiling and mark flue cut out.
3. Mark level line for base of canopy 700-800mm above bench 750mm desirable.
4. Position mounting bracket on wall and fix with four screws.
5. Cut a neat hole through the ceiling and remove any obstructing timbers.
6. Note: Various offsets are available from your QASAIR dealer to duct around any major structural beams which
cannot be removed. Ask your QASAIR dealer for advice.
7. In the case of back ducted models, cut a hole in the wall at the desired height.
8. Locate solid fixing point in wall to support hood. If there is no solid fixing point it will have to be placed in the wall
before proceeding. QASAIR recommend at least four (4) fixing points.
9. Drill holes in back of unit at suitable fixing points.
10. Drill 20mm hole in the rear of unit for 240 volt power cable as close as possible to junction box or use hole below
the junction box.
11. Attach flue (if applicable), then carefully lift into position on level line. Ensure flue is pushed into position and
electrical cable is fed into rear of unit.
12. Duct in approved manner to outside atmosphere.
Recommended xing points
Installation must be carried out by the procedure outlined.
Failure to do so may void the guarantee.
Electrical: Wiring to the appliance must comply with State and local Regulations.
Connection to be carried out by a registered electrician.
Qasair Rangehoods Installation Instructions
11
3 Flare
Technical Specification Sheet
3F Wall Mounted
3F 1200L-2
2
3
510mm
YESYES
2
1200mm
400mm
22
300mm
Cool
900mm
3F 900L-2
Cool
Light Centres
Filter Qty
Nightlight
Light Qty
LED Light
Motor Qty
Model
Body Width
Maximum Height
(H =)
Corner Type
648mm
Condari Pty Ltd.
4
All-thread
Fixing Centres
PowderKote
Available
Filter Size
Conversion
Top/Back Back/Top
Page 1 of 2
Motor Box /
Flue Width
Minimum Height
(H =)
Model
Electrical Connection
480mm
NO
3F 900L-2
272mm
x
3
5
5
m
m
Version: C 20/01/2015F
YES
1680mm
Junction Box Junction Box
NO
1680mm
YES
480mm
Round
N/A
Round
N/A
272mm
x
3
5
5
m
m
3F 1200L-2
Power Entry
Power Entry
A Transition is supplied to suit standard DL2 ducting.
Flues made to order for back ducted models.
Ø15mm Radius
Ø15mm Radius
Ø
5
1
0
8
0
9
0
2
5
0
4
8
0
1
8
0
A
v
a
i
l
a
b
l
e
L
e
n
g
t
h
s
:
6
0
0
m
m
9
0
0
m
m
1
2
0
0
m
m
3 FLARE - 3F
Qasair Rangehoods Installation Instructions12
3 Flare
Technical Specification Sheet
3F Wall Mounted
Filter Qty
Nightlight
Light Qty
Light Centres
Motor Qty
LED Light
Motor Box /
Flue Width
Model
Body Width
4
816mm
5
Conversion
Top/Back Back/Top
Condari Pty Ltd.
Maximum Height
(H =)
All-thread
Fixing Centres
Minimum Height
(H =)
Corner Type
3F 1500L-3 Model
648mm
Electrical Connection
PowderKote
Available
YES
Round
N/A
Version: C 20/01/2015F
Page 2 of 2
N/A
YES
450mm
3
1200mm
3F 1200L-3 3F 1200L-3
NO
Junction Box
272mm
x
3
5
5
m
m
480mm
1680mm 1680mm
3F 1500L-3
Round
Junction Box
Filter Size
3
2
Cool
272mm
x
3
5
5
m
m
NO
500mm
Cool
1500mm
2
YES
480mm
YES
Power Entry
Power Entry
Ø15mm
Radius
Ø15mm Radius
A Transition is supplied to suit standard DL3 ducting
.
F
l
u
e
s
m
a
d
e
t
o
o
r
d
e
r
f
o
r
b
a
c
k
d
u
c
t
e
d
m
o
d
e
l
s
.
5
1
0
8
0
9
0
2
5
0
4
8
0
A
v
a
i
l
a
b
l
e
L
e
n
g
t
h
s
:
6
0
0
m
m
9
0
0
m
m
1
2
0
0
m
m
2
3
0
3 FLARE - 3F
Qasair Rangehoods Installation Instructions
13
Motor Box /
Flue Width
Condari Pty Ltd. Page 1 of 2
Version: C 20/01/2015F
Body Width
Model
Motor Qty
Light Centres
Light Qty
Nightlight
LED Light
Filter Qty
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
SEA 600L-1 SEA 900L-2SEA 900L-1SEA 600L-1SEA 900L-2SEA 900L-1
600mm
Centre
2
N/A
1
Cool
YES
1
272mm
x
2
7
2
m
m
NO
Junction Box
400mm
1450mm
YES
400mm
Square
900mm
N/A
1
Cool
YES
2
510mm
3
900mm
N/A
2
Cool
YES
2
510mm
3
272mm
x
2
7
2
m
m
NO
Junction Box
400mm
1450mm
YES
700mm
Square
272mm
x
2
7
2
m
m
NO
Junction Box
400mm
1450mm
YES
700mm
Square
Senator
Technical Specification Sheet
SEA
Wall Mounted
Power entry location
is the same for all
Senator models.
H
4
0
0
3
1
0
A
l
l
-
T
h
r
e
a
d
r
o
d
s
a
r
e
s
u
p
p
l
i
e
d
f
o
r
e
x
t
r
a
s
u
p
p
o
r
t
.
SENATOR - SEA
Qasair Rangehoods Installation Instructions14
1300
m
m
Square
1300
m
m
Square
YES
400mm
Junction Box
NO NO
1450mm
Junction Box
Square
PowderKote
Available
1000
m
m
All-thread
Fixing Centres
3
Cool
1500mm
N/A
Maximum Height
(H =)
22
816mm
5
816mm
5
Cool
YES YES
N/A
1500mm
Cool
2
SEA 1500L-2 SEA 1500L-3
N/A
2
YES
2
Junction Box
NO
SEA 1200L-2
272mm
x
2
7
2
m
m
YES
400mm
272mm
x
2
7
2
m
m
272mm
x
2
7
2
m
m
1450mm
Model
Conversion
Top/Back Back/Top
400mm
YES
1450mm
SEA 1500L-3
Corner Type
Electrical Connection
Minimum Height
(H =)
SEA 1500L-2
Condari Pty Ltd.
Filter Size
648mm
4
1200mm
LED Light
Filter Qty
SEA 1200L-2
Motor Box /
Flue Width
Motor Qty
Light Centres
Light Qty
Nightlight
Model
Body Width
Version: C 20/01/2015F
Page 2 of 2
Senator
Technical Specification Sheet
SEA
Wall Mounted
Power entry location
is the same for all
Senator models.
4
0
0
3
1
0
H
A
l
l
-
T
h
r
e
a
d
r
o
d
s
a
r
e
s
u
p
p
l
i
e
d
f
o
r
e
x
t
r
a
s
u
p
p
o
r
t
.
SENATOR - SEA
Qasair Rangehoods Installation Instructions
15
Motor Box /
Flue Width
Condari Pty Ltd. Page 1 of 4
Version: C 20/01/2015F
Body Width
Model
Motor Qty
Light Centres
Light Qty
Nightlight
LED Light
Filter Qty
Model
Filter Size
Conversion
Top/Back Back/Top
Electrical Connection
Minimum Height
(H =)
Maximum Height
(H =)
PowderKote
Available
All-thread
Fixing Centres
Corner Type
SMF 600L-1 SMF 900L-2SMF 900L-1SMF 600L-1SMF 900L-2SMF 900L-1
600mm
3
1
0
m
m
2
450mm
1
Cool
YES
2
272mm
x
3
5
5
m
m
YES
Junction Box
N/A
N/A
YES
N/A
Round
900mm
750mm
1
Cool
YES
2
510mm
3
900mm
750mm
2
Cool
YES
2
510mm
3
272mm
x
3
5
5
m
m
YES
Junction Box
N/A
N/A
YES
N/A
Round
272mm
x
3
5
5
m
m
YES
Junction Box
N/A
N/A
YES
N/A
Round
Maitland
Technical Specification Sheet
SMF
Wall Mounted
Power entry location
is the same for all
SMF models.
5
1
0
1
5
0
1
1
0
2
0
4
5
0
2
0
1
1
0
2
8
0
Ø15mm Radius
Ø15mm
Radius
MAITLAND - SMF
Qasair Rangehoods Installation Instructions16
Maitland
Technical Specification Sheet
SMF
Wall Mounted
Model
Conversion
Top/Back Back/Top
Minimum Height
(H =)
Electrical Connection
Filter Size
Body Width
Motor Box /
Flue Width
Model
Maximum Height
(H =)
SMF 1000L-2
290mm
x
3
5
5
m
m
N/A
All-thread
Fixing Centres
Corner Type
Version: C 20/01/2015F
648mm
4
Condari Pty Ltd.
Round
N/A
N/A
Round
YES
Motor Qty
Page 2 of 4
N/A
YES
Nightlight
Light Qty
850mm
1000mm
SMF 1000L-2
510mm
3
LED Light
Light Centres
Filter Qty
Junction Box
YES
SMF 1200L-2
2
SMF 1200L-2
2
YES
2
Cool
2
N/ACool
YES
1050mm
1200mm
272mm
x
3
5
5
m
m
YES
Junction Box
N/A
PowderKote
Available
2
8
0
1
1
0
2
0
4
5
0
2
0
1
1
0
1
5
0
5
1
0
Power entry location
is the same for all
SMF models.
Ø15mm Radius
Ø15mm
Radius
MAITLAND - SMF
Qasair Rangehoods Installation Instructions
17
Minimum Height
(H =)
Filter Size
Model
Conversion
Top/Back Back/Top
N/A
SMF 1500L-3
Electrical Connection
Page 3 of 4
Body Width
Motor Box /
Flue Width
Motor Qty
Model
Nightlight
Filter Qty
Light Qty
Version: C 20/01/2015F
Light Centres
Maximum Height
(H =)
Corner Type
Condari Pty Ltd.
1350mm
1500mm
SMF 1500L-2
5
LED Light
816mm
YES
N/A
YES
Junction Box
272mm
x
3
5
5
m
m
SMF 1500L-2
N/A
SMF 1800L-3
YES
YESYES
2
N/A
272mm
x
3
5
5
m
m
290mm
x
3
5
5
m
m
All-thread
Fixing Centres
PowderKote
Available
SMF 1800L-3
1800mm
1650mm
4
3
1500mm
1350mm
422mm
6
YES
5
Cool Cool
3
2
SMF 1500L-3
N/A
Round
YES
Junction BoxJunction Box
YES
N/A
Round
N/A
YES
N/A
Round
N/A
816mm
2
Cool
Maitland
Technical Specification Sheet
SMF
Wall Mounted
2
8
0
1
1
0
2
0
4
5
0
2
0
1
1
0
1
5
0
5
1
0
Power entry location
is the same for all
SMF models.
Ø15mm Radius
Ø15mm
Radius
MAITLAND - SMF
Qasair Rangehoods Installation Instructions18
Wall Mounted
Maitland
Technical Specification Sheet
SMF
SMF 600L-1
SHROUD
YES YES
SMF 900L-2
SHROUD
1450mm1450mm
SMF 1500L-3
SHROUD
300mm
Version: C 20/01/2015F
Page 4 of 4
SMF 1200L-2
SHROUD
Condari Pty Ltd.
Model
3
0
0
m
m
3
0
0
m
m
1450mm
YES
Minimum Height
(H =)
Maximum Height
(H =)
YES
Powderkote
A
v
a
i
l
a
b
l
e
300mm
1450mm
SMF 900L-1
SHROUD
YES
SMF 1000L-2
SHROUD
YES
1450mm
300mm
YES
1450mm
300mm
YES
300mm
1450mm1450mm
300mm
SMF 1500L-2
SHROUD
SMF 1800L-3
SHROUD
S
M
F
6
0
0
L
-
1
S
H
R
O
U
D
S
M
F
9
0
0
L
-
1
S
H
R
O
U
D
S
M
F
9
0
0
L
-
2
S
H
R
O
U
D
S
M
F
1
0
0
0
L
-
2
S
H
R
O
U
D
S
M
F
1
2
0
0
L
-
2
S
H
R
O
U
D
S
M
F
1
5
0
0
L
-
2
S
H
R
O
U
D
S
M
F
1
5
0
0
L
-
3
S
H
R
O
U
D
S
M
F
1
8
0
0
L
-
3
S
H
R
O
U
D
MAITLAND - SMF
Qasair Rangehoods Installation Instructions
19
Compact
Technical Specification Sheet
CM
Wall Mounted
CM 900L-2
2
3
510mm
YESYES
2
900mm
750mm
21
450mm
Cool
900mm
CM 900L-1
Cool
Light Centres
Filter Qty
Nightlight
Light Qty
LED Light
Motor Qty
Model
Body Width
Maximum Height
(H =)
Corner Type
510mm
Condari Pty Ltd.
3
All-thread
Fixing Centres
PowderKote
Available
Filter Size
Conversion
Top/Back Back/Top
Page 1 of 3
Motor Box /
Flue Width
Minimum Height
(H =)
Model
Electrical Connection
N/A
YES
CM 900L-1
272mm
x
3
5
5
m
m
Version: C 20/01/2015F
YES
N/A
Junction Box Junction Box
YES
N/A
YES
N/A
Round
N/A
Round
N/A
272mm
x
3
5
5
m
m
CM 900L-2
Power Entry
Ø15mm
Radius
5
1
0
8
0
2
0
1
1
0
4
1
5
1
1
0
2
0
2
8
0
Ø15mm
Radius
Power Entry
COMPACT - CM
Qasair Rangehoods Installation Instructions20
Compact
Technical Specification Sheet
CM
Wall Mounted
Filter Qty
Nightlight
Light Qty
Light Centres
Motor Qty
LED Light
Motor Box /
Flue Width
Model
Body Width
3
648mm
4
Conversion
Top/Back Back/Top
Condari Pty Ltd.
Maximum Height
(H =)
All-thread
Fixing Centres
Minimum Height
(H =)
Corner Type
CM 1200L-2 Model
510mm
Electrical Connection
PowderKote
Available
YES
Round
N/A
Version: C 20/01/2015F
Page 2 of 3
N/A
YES
850mm
2
1000mm
CM 1000L-2 CM 1000L-2
YES
Junction Box
290mm
x
3
5
5
m
m
N/A
N/A N/A
CM 1200L-2
Round
Junction Box
Filter Size
2
2
Cool
272mm
x
3
5
5
m
m
YES
1050mm
Cool
1200mm
2
YES
N/A
YES
Ø15mm
Radius
Ø15mm
Radius
2
8
0
2
0
1
1
0
4
1
5
1
1
0
2
0
8
0
5
1
0
Power Entry
Power Entry
COMPACT - CM
Qasair Rangehoods Installation Instructions
21
Wall Mounted
Compact
Technical Specification Sheet
CM
Condari Pty Ltd.
Version: C 20/01/2015F
Page 3 of 3
YES
Powderkote
A
v
a
i
l
a
b
l
e
YES
Maximum Height
(H =)
Minimum Height
(H =)
1450mm
335mm335mm
1450mm
Model
CM 1000L-2 SHROUD
1450mm
YES
3
3
5
m
m
CM 900L-2 SHROUD
3
3
5
m
m
CM 1200L-2 SHROUD
1450mm
YES
CM 900L-1 SHROUD
C
M
9
0
0
L
-
1
S
H
R
O
U
D
C
M
9
0
0
L
-
2
S
H
R
O
U
D
C
M
1
0
0
0
L
-
2
S
H
R
O
U
D
C
M
1
2
0
0
L
-
2
S
H
R
O
U
D
COMPACT - CM
Loading...
+ 47 hidden pages