Q U I C K S T A R T G U I D E

I S C S I H O S T B U S A D A P T E R I N S T A L L A T I O N

z

 

 

Q L A ®4 0 5 0 / 4 0 5 0 C / 4 0 5 2 C

Q L E 4 0 6 0 C / 4 0 6 2 C

Purchasers of OEM products should consult with the OEM for support.

Please feel free to contact your QLogic approved reseller or QLogic Technical Support at any phase of integration for assistance. QLogic Technical Support can be reached by the following methods:

Web

http://support.qlogic.com

E-mail

support@qlogic.com

The QLogic knowledge database contains troubleshooting information for the QLogic host bus adapters. Access the data base from the QLogic Support Web page, http://support.qlogic.com. Use the Support Center search engine to look for specific troubleshooting information.

Quick Start Guide

Installation Instructions

This Quick Start Guide describes how to install and configure your new QLogic SANblade® host bus adapter and SANsurfer iSCSI HBA Manager application in four simple steps:

Step 1. Verify the package contents.

Step 2. Install the host bus adapter hardware.

Step 3. Install the host bus adapter driver.

Step 4. Install the SANsurfer iSCSI HBA Manager application.

 

Keep the host bus adapter in the antistatic bag until installation. The host bus adapter contains parts that can be

 

damaged by electrostatic discharge (ESD). Before handling the host bus adapter, use standard methods to discharge

CAUTION!

static electricity. Place the host bus adapter on the bag when examining it. Retain the bag for future use.

System Requirements

Your system must have the functionality described in the following sections to support the QLogic SANblade host bus adapter.

Minimum Software Requirements

Windows® 2000: Service Pack (SP) 4 or later (QLA405x host bus adapters)

Windows® Server2003 SP 1 or SP 2

Windows XP Pro SP 1 or SP 2

Windows PE 2.0, 2004, 2005

Windows Vista (Business and Enterprise)

LinuxRed Hat® Enterprise Linux 3.0 Update 7 or later (QLA405x host bus adapters), Linux Red Hat Enterprise Linux 4.0 Update 3 or later (QLA405x and QLE406xC host bus adapters)

Novell SUSE Linux: SLES 8 Update 3 or later (QLA405x host bus adapters), SLES 9 Update 2 or later (QLA405x and QLE406xC host bus adapters), SLES 10 (QLA405x and QLE406xC host bus adapters)

Solaris: Solaris 9 or later for Solaris SPARC and x86 (IA32 and x64)

VMware® 3.0.1 (QLA405x host bus adapters)

NOTE: The operating systems listed above are applicable to all host bus adapter models unless otherwise noted.

Minimum Hardware Requirements

Empty PCI-X32-bitorPCI-X64-bitslot (QLA405x host bus adapters),2.5-GHzPCI Express x4 slot (QLE406xC host bus adapters)

PCI-X:3.3-voltsignaling (QLA4050 host bus adapters); 3.3V or5-voltsignaling (QLA4050/4052C host bus adapters)

The correct media:

QLA4050: 62.5/125-µMmultimode fiber

QLA4050C/4052C, QLE4060C/4062C: UTP copper (Cat5E or Cat6)

3

The correct connectors:

QLA4050: LC duplex

QLA4050C/4052C, QLE4060C/4062C: RJ45

Step 1. Verify the Package Contents

The QLogic host bus adapter is shipped with the following items:

QLogic SANblade host bus adapter

Low-profilebracket (not available in all models)

Quick Start Guide (this document)

SANsurfer® for SANblade iSCSI HBAs CD(s)

Step 2. Install the Host Bus Adapter Hardware

NOTE: When installing the QLogic host bus adapter and driver in a Solaris system that does not already have QLogic host bus adapters or drivers installed, please install the QLogic Solaris driver before you install the QLogic host bus adapter hardware. This allows Solaris to correctly bind the QLogic Solaris driver to the QLogic host bus adapter. Failure to do so will require an additional system reboot after the driver is loaded.

To install the host bus adapter hardware, you need to open the computer and locate the appropriate bus slot. If necessary, consult your computer system manual for instructions to remove the computer cover.

Depending on the host bus adapter you are installing, the bus connector will look like one of the following samples:

 

 

PCI-X

PCI Express

 

 

 

 

 

 

QLA4050

N/A

 

Optical

 

 

 

 

 

 

 

 

QLA4050C

QLE4060C

 

 

 

 

 

Copper

QLA4052C

QLE4062C

 

 

 

 

 

 

 

 

 

 

 

4

Follow these steps to install the host bus adapter hardware:

1.Power off the computer, then disconnect the power cable.

2.Remove the computer cover and find an empty bus slot.

3.Pull out the slot cover (if any) by removing the screw or releasing the lever.

4.Grasp the host bus adapter by the top edge and seat it firmly into the slot.

5.Refasten the host bus adapter’s retaining bracket using the existing screw or lever.

6.Close the computer cover.

7.Plug in the power cable and turn on the computer.

 

 

 

 

HOST BUS

 

 

LEVER

 

 

ADAPTER

 

64-BITPCI-XSLOT

 

 

 

 

 

 

 

 

 

 

 

 

(QLA405x HOST BUS

SCREW

 

 

 

 

ADAPTERS) OR

 

 

 

 

 

 

 

 

 

 

 

PCI EXPRESS x4, x8, x16

 

 

 

 

 

 

SLOT (QLE406xC HOST BUS

HOST BUS ADAPTER RE-

 

 

 

 

ADAPTERS)

 

 

 

 

 

TAINING BRACKET

 

 

 

 

 

 

 

 

 

 

SLOT COVERS

 

 

 

 

 

 

 

 

 

 

SYSTEM

CHASSIS

Sample motherboard and slots

Step 3. Install the Host Bus Adapter Driver

After you have completed the hardware installation and turned on the computer, insert the applicable SANsurfer for SANblade iSCSI HBAs CD into theCD-ROMdrive, based on your operating system. Follow the instructions below for your operating system.

The latest drivers and documentation can be found on the QLogic Web site, www.qlogic.com.

Windows 2000 (QLA405x Host Bus Adapters only)

NOTE: If an earlier version of the Windows 2000 driver is already installed, see the readme file for information about updating the existing driver.

Perform the following steps to install the host bus adapter driver for Windows 2000:

1.Log onto the computer as Administrator.

2.Download and save the host bus adapter driver to your hard drive:

a.Type or browse the path to the QLogic driver directory on the applicable SANsurfer for SANblade iSCSI HBAs CD. For example:

<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows

5

b.Locate and launch (double-click)the executable (.exe) file containing the driver.

c.When prompted, type or browse to a location on your hard drive to store the driver files. Click OK.

3.Windows detects the newly installed device, then displays the Found New Hardware with Ethernet Controller message. ClickNext.

4.In the Install Hardware Device Driversdialog box, select Search for a suitable driver for my device (recommended). Click Next.

5.In the Locate Driver Filesdialog box, select Specify a Location. Click Next.

6.In the Copy manufacture's files from: dialog box, type or browse the path to the directory where you stored the driver files<blue text>(see step 2). ClickOK.

7.In the Driver Files Search Resultsdialog box, click Next.

8.In the Completing the Found New Hardware Wizarddialog box, click Finish.

9.The Found New Hardware - Network Controller message displays. The Found New Hardware Wizard program is launched to begin installing the driver for theQLogic iSCSI HBA. ClickNext.

10.In the Install Hardware Device Drivesdialog box, select Search for a suitable driver for my device (recommended). Click Next.

11.Select specify a location. Click Next.

12.In the Copy manufacture's files from: field, type or browse the path to the to the directory where you stored the driver files<blue text>(see step 2).

13.In the Driver Files Search Resultsdialog box, click Next.

14.When the Digital Signature Not Found dialog box displays, clickYes.

15.In the Completing the Found New Hardware Wizarddialog box, click Finish.

16.If following message displays, click Yes:

Your hardware settings have changed. You must restart your computer for these changes to take effect. Do you want to restart your computer now?

NOTE: If you are installing adual-portQLA4052C host bus adapter,Steps 316 must be repeated for the second port.

Windows Server 2003

NOTE: If an earlier version of the Windows Server 2003 driver is already installed, see the readme file for information about updating the existing driver.

Perform the following steps to install the host bus adapter driver for Windows Server 2003:

1.Log onto the computer as Administrator.

2.Download and save the host bus adapter driver to your hard drive:

a.Type or browse the path to the QLogic driver directory on the applicable SANsurfer for SANblade iSCSI HBAs CD. For example:

<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows

b.Locate and launch (double-click)the executable (.exe) file containing the driver.

c.When prompted, type or browse to a location on your hard drive to store the driver files. Click OK.

3.Windows detects the newly installed device, then displays the Found New Hardware with Ethernet Controller message.

4.Select Install from a list or specific location (Advanced), then click Next.

5.Select the Search for the best driver in these locationsoption. Type or browse the path to the directory where you stored the driver files <blue text>(see step 2), then click Next.

6.In the Security Alert - Driver Installationdialog box, click Yes.

7.In the Completing the Found New Hardware Wizarddialog box, click Finish.

6

8.The Found New Hardware Wizard with Network Controllermessage displays. The Found New Hardware Wizard program is launched to begin installing the iSCSI driver for the QLogic iSCSI HBA.

9.Select Install from a list or specific location (Advanced). Click Next.

10.Select the Search for the best driver in these locationsoption. Type or browse the path to the directory where you stored the driver files (see Step 2).

11.In the Hardware Installation - Windows Logodialog box, click Continue Anyway.

12.In the Completing the Found New Hardware Wizarddialog box, click Finish.

Windows Vista

Initial Operating System Installation with the Host Bus Adapter Driver as Boot or as an Add-On

Perform the following steps to install the Windows Vista operating system and the host bus adapter driver (as boot as or as an add-on):

1.Start the Windows installation procedure using the Setup CD.

2.The following message displays:

Which type of installation do you want?

Select Custom (Advanced).

3.The following message displays:

Where do you want to install Windows?

Select Load Driver.

4.Download and save the host bus adapter driver to your hard drive:

a.Type or browse the path to the QLogic driver directory on the applicable SANsurfer for SANblade iSCSI HBAs CD. For example:

<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows

b.Locate and launch (double-click)the executable (.exe) file containing the driver.

c.When prompted, type or browse to a location on your hard drive to store the driver files. Click OK.

5.At the Load Driver screen, type or browse the path to the directory where you stored the driver files <blue text>(see step 4), then click OK.

6.Click Next to continue with the standard installation procedure.

Adding the Host Bus Adapter Driver to an Existing Operating System

Perform the following steps to add the host bus adapter driver to an existing operating system:

1.After installing the iSCSI host bus adapter and restarting your computer, download and save the host bus adapter driver to your hard drive:

a.Type or browse the path to the QLogic driver directory on the applicable SANsurfer for SANblade iSCSI HBAs CD. For example:

<CD-ROM Drive Letter>:\autoplay\iSCSI_HBA_drivers\Windows

b.Locate and launch (double-click)the executable (.exe) file containing the driver.

c.When prompted, type or browse to a location on your hard drive to store the driver files. Click OK.

2.

Windows detects the newly installed device and displays the Found New Hardware message.

 

The Hardware Update Wizard program starts installing a device driver for the newly installed device.

3.Select the Driver tab, then click Update Driver to start the Hardware Update Wizard.

4.Select Browse my computer for driver software, then click Next.

5.Select Let me pick from a list of device drivers on my computer, then click Next.

6.Click Have Disk.

7

7.On the Install from Disk screen, select the directory where you stored the driver files <blue text>(see step 1), then clickOK.

8.When the Update Driver Software Wizard/Select QLogic iSCSI Adapter window displays, click Next.

9.Click Close on the Update Driver Software Wizard window.

Linux (Driver and RAMDisk Image)

The following installation instructions are applicable to SLES 9 (or later) or Red Hat Enterprise Linux 4.0 (or later). For more information and driver installation instructions for other Linux operating system versions, see the README.txt file associated with the driver.

1.Download the latest driver file qla4xxx-vx.yy.zz.tar.gzfrom theSANsurfer for SANblade iSCSI HBAs CD. The driver is located in the following directory: autoplay\iscsi_HBA_drivers\Linux

2.Type the following to uncompress the tar file:

#tar -xvzf*.gz

3.Type the following to compile the driver:

#cd x.yy.zz

#./extras/build.sh install

4.Type the following to load the driver:

#modprobe –vqla4xxx

5.Optionally, type the following to compile the driver and create a RAMDisk image that will automatically load the driver when the system is rebooted:

#./extras/build.sh initrd

To unload the driver, type the following:

# modprobe –rqla4xxx

Solaris

NOTE: If an earlier version of the Solaris driver is already installed, you mustun-installthis driver before installing the latest driver. For more information, see the section in the README.txt file about removing the driver.

1.Login to the Solaris system as root.

2.Type the following command to uncompress the package:

uncompress <directory containing package file>/qla4xxx.Z

3.Type the following command to start the package installation:

pkgadd -d <directory containing package file>/qla4xxx

4.Follow and answer the prompts displayed to finish the installation.

a.When the package selection prompt displays, enter the number corresponding to the driver package applicable to the Solaris version installed on the target system.

b.At the driver destination prompt, press ENTER to place the driver in the default directory, which is usually /kernel/drv.

c.When prompted to continue and to complete the QLogic driver installation procedure, press Y.

For more help, see the Solaris man page on pkgadd.

5.After the pkgadd program completes, type the following command to reboot the system: reboot -- -r

NOTE: Modify the system sd.conf file (/kernel/drv/sd.conf) for the operating system to recognize new targets. QLogic recommends adding up to 255 targets. The QLogic SANblade host bus adapter supports up to 128 devices.

8

To unload the driver, perform the following steps:

1.Login to the Solaris system as root.

2.Type the following command: pkgrm QLA4xxx-0

3.Type the following command to reboot the system: reboot -- -r

Step 4. Install the SANsurfer iSCSI HBA Manager Application

To install the SANsurfer iSCSI HBA Manager application:

1.Insert the applicable SANsurfer for SANblade iSCSI HBAs CD into yourCD-ROMdrive (if theauto-runscreen does not appear, open thestart_here html page with your browser.)

2.Select your operating system.

3.Click I Accept on the License Agreement.

4.Click to select the specific version of your operating system.

5.Select the SANsurfer iSCSI HBA Manager install file.

6.Follow the on-screendirections and installation prompts.

Congratulations! You have successfully installed your QLogic Host Bus Adapter and management application!

To obtain the most current drivers, management applications, user instructions, and documentation, please visit the QLogic website at www.qlogic.com/support and download the latest versions.

The following section contains additional information about the SANblade QLogic host bus adapter, including the LED scheme, troubleshooting, warranty, technical support and certification information.

Host Bus Adapter LEDs

Table 1 lists the LED configuration for the QLogic QLA4050 host bus adapter.

Table 1. QLogic QLA4050 Host Bus Adapter LED Scheme

Green LED

Activity

Link established

Table 2 lists the LED configuration for the QLogic QLA4050C/4052C and QLE4060C/4062C host bus adapters.

Table 2. QLogic QLA4050C/4052C and QLE4060C/4062C Host Bus Adapter

LED Scheme

Green LED

Activity

Link established

Flashing

Receive/transmit activity

9

Troubleshooting and Technical Support

The QLogic knowledge database contains troubleshooting information and documentation for the QLogic SANblade host bus adapters. The knowledge base is available to all users at http://support.qlogic.com.

For technical support, visit our web site support.qlogic.com, email us atsupport@qlogic.com, or call at952-932-4040.

Warranty

The QLogic SANblade host bus adapter comes with a standard three year QLogic warranty. Please check the QLogic Web site at http://support.qlogic.com/support/warranty.asp for warranty details.

Laser Safety

FDA Notice

This product complies with DHHS Rules 21CFR Chapter I, Subchapter J. This product has been designed and manufactured according to IEC60825-1on the safety label of laser product.

Class 1 Laser Product Appareil laser de classe 1 Produkt der Laser Klasse 1 Luokan 1 Laserlaite

Caution—Class1 laser radiation when open Do not view directly with optical instruments

Attention—Radiationlaser de classe 1

 

 

Ne pas regarder directement avec des instruments optiques

CLASS I LASER PRODUCT

 

Vorsicht—Laserstrahlungder Klasse 1 bei geöffneter

 

 

Abdeckung

 

Direktes Ansehen mit optischen Instrumenten vermeiden

 

Agency Certification

QLogic SANblade Host Bus Adapters

The following sections contain a summary of EMC/EMI test specifications performed on the following QLogic SANblade host bus adapters to comply with radiated emission, radiated immunity, and product safety standards:

 

QLA4050

(IS0710404)

 

QLA4050C

(IS0710407)

 

QLA4052C

(IS0710403)

QLE4060C/QLE4062C (IX4010402)

EMI and EMC Requirements

FCC Part 15 compliance: Class B

FCC compliance information statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

ICES-003compliance: Class B

This Class B digital apparatus complies with Canadian ICES-003.

Cet appareil numériqué de la classe B est conformé à la norme NMB-003du Canada.

CE Mark 89/336/EEC EMC Directive compliance:

EN55022:1998/CISPR22:1997—ClassB

EN55024:1998

10

Immunity Standards

IEC61000-4-2

: ESD

IEC61000-4-3

: RF Electro Magnetic Field

IEC61000-4-4

: Fast Transient/Burst

IEC61000-4-5

: Fast Surge Common/ Differential

IEC61000-4-6

: RF Conducted Susceptibility

IEC61000-4-8

: Power Frequency Magnetic Filed

IEC61000-4-11

: Voltage Dips and Interrupt

IEC61000-3-2

: Harmonic Current Emission

IEC61000-3-3

: Voltage Fluctuation and Flicker

VCCI compliance: Class B

AS/NZS CISPR22 compliance: Class B

CNS 13438 compliance: Class B

MIC compliance: Class B

Korea MIC Class B Certified

 

 

 

Product Name/Model

 

iSCSI host bus adapter

 

 

 

Certification holder

 

QLogic Corporation

 

 

 

Manufactured date

 

Refer to date code listed on product

 

 

 

Manufacturer/Country of origin

QLogic Corporation/USA

 

 

 

 

 

 

 

 

 

 

B class equipment

 

As this equipment has undergone EMC registration for

 

 

 

(Household purpose info/telecommunications

 

household purpose, this product can be used in any area

 

 

 

equipment)

 

including residential area.

 

Korean Language Format— Class B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Safety Compliance

UL, cUL product safety compliance:

UL60950

CSA C22.2 No.60950

Class 1 Laser Product per DHHS 21CFR (J)

Use only with listed ITE or equivalent.

73/23/ECC low voltage directive:

TUV: -EN60950-1:2001-EN60825-1-EN60825-2

11

12

13

14

© 2005–2009QLogic Corporation. QLogic , the QLogic logo, SANsurfer, and SANsurfer Mangement Suite are trademarks or registered trademarks of QLogic Corporation. All other brands and product names are trademarks or registered trademarks of their respective owners. Information supplied by QLogic is believed to be accurate and reliable. QLogic Corporation assumes no responsibility for any errors in this brochure. QLogic Corporation reserves the right, without notice, to makes changes in product design or specifications.

*IS0054501-00D*

QLogic Corporation

26650 Aliso Viejo Parkway

Aliso Viejo, CA 92656

949.389.6000