LOW NOx MAXIM ▪ PACKAGED GAS WATER HEATER
®
NICKELSHIELD
STANDARD FEATURES AND EQUIPMENT
82% thermal efficiency
SCAQMD compliant
NOx emissions certified at <55 ppm at 3% 0
NOx emissions certified at <30 ppm at 3% 0
NICKELSHIELD
Nonferrous, removable fittings at all tank connections
Nickel-plated, copper-clad steel firetubes
SCALEGUARD
Upper and lower immersion operating thermostats
Immersion temperature limiting device (high limit control)
ASME-rated temperature and pressure relief valve
Drain valve
Handhole tank cleanout
Power combustion burner
Spark ignition
Electronic combustion sequencer and flame safeguard with pre-purge
Combustion sequence indicating lights (> 399,000 Btu/h)
Differential pressure air flow switch
Second main gas valve (> 399,000 Btu/h)
Compliant with ASHRAE 90.1 for thermal efficiency and standby loss
Fiberglass insulated tank
Draft regulator (barometric damper)
Steel jacket panels with industrial-grade finish
Factory-authorized start up
ASME stamped—150 psi MAWP
National Board Registered for 150 psi working pressure
UL listed to safety standard UL 795 “Commercial-Industrial Gas Heating Equipment”
FM compliant
®
nickel-plated tank with 10-year warranty, three-year scale failure warranty and one-year cost-free service policy
®
tubesheet protection
NICKEL-PLATED STORAGE TANK
and/or less than 40 nanograms per joule (199 to 399 MBtu/h)
2
(above 399 MBtu/h)
2
OPTIONAL FEATURES AND EQUIPMENT
Long-life service policy AGA-rated temperature and pressure relief valve(s) 2,500,000 Btu/h FM controls package. Adds electronic low-water cutoff, manual-reset high limit, single-try firing control and high-low
gas pressure switch. (not required for FM compliance below 2,500,000 Btu/h) (available only on 540,000 and 650,000 Btu/h)
CSD-1 / IRI compliant components include manual reset electronic low water cut off, manual reset temperature limiting device and
Hi-Lo gas pressure switch (as required)
Electronic combustion sequencer and flame safeguard with pre– and post-purge Electronic low-water cutoff Manual-reset, temperature limiting device DUO-SET controls for dual-temperature applications Dial temperature and pressure gauges Tridicator Alarm bell with silencing switch Seven-day time clock Digital seven-day time clock with battery backup Air intake assembly for remote combustion air (requires field connection to ductwork supplied by others)
Consult factory for other codes
See complete warranty and/or service policy for details
PV 6382 11/07
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
(800) 784-8326 (817) 335-9531 www.pvi.com
PVI reserves the right to change
without notice.