LOW NOx MAXIM • PACKAGED GAS WATER HEATER
POLYSHIELD® POLYMER-LINED STORAGE TANK
119 GALLON TANK SERIES
MODEL NUMBER
GPH Recovery at 40° to 120° F 245
GPH Recovery at 40° to 140° F 195
Input Btu/h 199,000
Minimum gas inlet pressure – " W.C. 5.5
A Cold Inlet - NPT 2
B Hot Outlet - NPT 2
C Drain - NPT 1
D I - Beam Skids 3 X 34-1/2
E Overall Depth 47
F Overall Height 75
G Flue Outlet Diameter 5
H Gas Inlet - NPT 1/2
J Motor HP 120 V, 1Ø, 60 Hz. 1/6
Motor Amps 1.75
L Height to Outlet 65
M Height to Inlet 28
Approx. Shipping Weight - lbs 1070
Recoveries based on 82% thermal efficiency. ASHRAE 90.1 compliant.
Dimensions are in inches unless otherwise specified.
For standard and optional equipment, see Form # PV6377.
34 1/2
20 P 119A-MXS
1
1. Control Enclosure
2. ASME Temperature &
Pressure Relief Valve
3. 3” NPT Handhole
41
G
B
2
F
L
H
C
J
23
M
D
STANDARD GAS PRESSURE REQUIREMENTS:
SEE TABLE FOR MINIMUM PRESSURE BY MODEL NUMBER.
MAXIMUM STATIC PRESSURE: 9" W.C.
FOR GAS PRESSURES OUTSIDE OF THIS RANGE,
CONTACT YOUR PVI REPRESENTATIVE.
THE ENTIRE VENT SYSTEM SHOULD NEVER BE SIZED BASED UPON THE
FOR PROPER VENT SIZING, CONSULT THE NATIONAL FUEL GAS CODE
STANDARD ELECTRICAL REQUIREMENTS:
CONTROL VOLTAGE: 120V, 1Ø, 60 HZ., 2 AMPS
PVI RESERVES THE RIGHT TO CHANGE THE DESIGN AND
PVI INDUSTRIES, LLC
FORT WORTH, TEXAS 76111
PV 6433 01/06 (800) 784-8326 • www.pvi.com
A
3
E
VENTING REQUIREMENTS:
-.02" TO -.06" W.C. (NEGATIVE PRESSURE).
TYPE B VENTING.
VENT CONNECTION DIAMETER EXCLUSIVELY.
UNDER "FAN-ASSISTED".
SPECIFICATION WITHOUT NOTICE.
Product is patented in the U.S., Canada, and Mexico.