Puretec Tripla, Tripla T2, Tripla T1, Tripla T3, Tripla T4 User Manual

...
Page 1
User Guide
CERT N O. 23033
AS/NZ S 3718:2005
Tripla™
Puretec Tripla™ | Triple Action Tapware
For correct operation & installation it is essential to observe these instructions.NOV 2019
Page 2
What's inside
Operation ...................................................................................................................................... 2
Servicing........................................................................................................................................ 3
Technical Information
Recommended Working Pressures
Installation Guide
Assembly
Water Connection Patterns
Battery Installation
Replacement of Ceramic Disc Cartridge(s)
Tripla T1 Parts Description
Tripla T2 Parts Description
Tripla T3 Parts Description
Tripla T4 Parts Description
Tripla T5 Parts Description
Tripla T6 Parts Description
Warranty
...................................................................................................................................... 5
..........................................................................................................................................14
............................................................................................................ 3
................................................................................. 3
..................................................................................................................... 4
......................................................................................................6
.......................................................................................................................7
................................................................ 7
.................................................................................................. 8
.................................................................................................. 9
............................................................................................... 10
............................................................................................... 11
............................................................................................... 12
............................................................................................... 13
What's Inside
Thank you for purchasing a Puretec Tripla. Your tap is manufactured from only quality materials and will last for years, if maintained and installed properly.
The system is designed for metropolitan supply water but can be used in other situations. For other types of water supply please contact your local Puretec stockist or call our Puretec Customer Service Helpline prior to installing the tap.
Customer Service Helpline 1300 140 140 (Australia) 0800 130 140 (New Zealand)
This product contains a button battery. Accidental ingestion may occur and can be fatal. Please keep out of reach from infants. If you suspect an accidental ingestion please contact emergency services.
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
2
Page 3
Introduction
Operation
Chrome Plated Surface - should only be cleaned with liquid detergent or soap and water.
Under no circumstance should any abrasive or acid base cleaning agents be used.
Servicing
Periodically clean the aerator for any lodged sediment that may restrict ow. A Puretec water lter is highly recommended for product longevity.
Should it be necessary to have your mixer serviced while under warranty, please carry out the following procedure:
1. Firstly call the plumber, preferably the one that has installed it, (most problems are caused by the supply lines not being cleaned out properly, prior to connecting the mixers).
2. Make sure that the plumber has installed your mixer according to the Instruction Guide.
3. If the plumber is satised that he cannot rectify the problem then contact your
plumbing supply store or your local Puretec stockist.
Important: We do not recommend the dismantling of any internal part of the mixer purely to see what is inside as this will breach your warranty.
Technical Information
Puretec mixers can be used in conjunction with:
• Pressure storage hot water system
• Any mains water pressure not exceeding 500 kPa
• Maximum hot water temperature of 60°C
• Instantaneous hot water system
Recommended Working Pressures
• Minimum working pressure 50 kPa (7.5 PSI)
• Maximum working pressure 500 kPa
It should be noted that water mains pressure builds up during o peak periods, mainly
at night, sometimes doubling or trebling normal daytime pressures.
Note: Not suitable for unequal pressure. On high pressure areas where the pressure exceeds the recommended working pressure as indicated above pressure limiting valves must be installed or warranty is voided.
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
3
Page 4
Installation Guide
Installation Guide
Mixer Tap
Rubber Washer
Sink Faucet
Hole (Ø33mm)
Rubber Washer
Metal Washer
COLD
HOT
Retainer Screw
Water Filter
Metal Pipe
Locking Nut
Note: It is important to ush out the supply pipes to the mixer before connecting the exible hoses, with the initial installation, so
no foreign matter can enter into the cartridges.
A Puretec Water Filter is highly recommended for product longevity.
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
4
Page 5
Assembly
Assembly
Step 1. Connect the hoses to the faucet and tighten them.
Only use hand to screw the exible
hose. Do not over tight. Don't use any tools.
Step 2. Put Brass Base with O-Ring to the bottom of the faucet.
Step 3. Put the hoses through the Basin or Sink. Required through hole size is Ø33mm.
1
2
Basin or Sink
33mm dia.
Hole
Brass Base
O-Ring
Step 4. Place the Retainer Screw through the hole in each Spacer and screw to the hole on the bottom of the faucet.
Then, use a wrench to lock the Retainer Nut.
Rubber Spacer
Zinc Spacer
Retainer Screw
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
Retaining
Nut
5
Page 6
Water Connection Patterns
Connections
For TRIPLA T1 & T2
For TRIPLA T3 to T6
Water Filter
Connection
Water Filter
Connection
Retainer
Screw
COLD Water Connection
Retainer Screw
HOT Water Connection
COLD Water Connection
Retainer
Screw
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
6
HOT Water Connection
Page 7
Maintenance
Battery Installation - LED reminder light
Important note: Battery must be replaced when changing cartridges. WARNING! This
product contains a battery. Accidental ingestion may occur and can be fatal. Please keep out of reach from infants. If you suspect an accidental ingestion please contact emergency services.
1. Remove the black battery seat from the faucet canopy.
Note: Red light ashes
twice and then followed by the blue light.
3. Reinstall battery seat assembly into the faucet canopy.
2. Install battery into the battery seat, positive side up.
Positive side up.
Negative on the PCB.
4. Blue light ashes during
normal operation.
5. Red light ashes indicates your cartridges
are due to be changed (usage has exceeded 3,000 minutes or 12 months).
Please change the battery when
changing the lter cartridge(s).
Replacement of Ceramic Disc Cartridge(s)
1. Hot/Cold Outlet
• Remove hot and cold water indicator then release screw in lever and li lever o,
now you can unscrew dome cap and loosen the cartridge lock nut.
• Li out old cartridge and clean inside making sure no old O-rings are still stuck
inside cartridge housing.
• Insert new cartridge making sure O-rings on bottom of new cartridge have not
fallen o and lugs in bottom of cartridge line up with holes in cartridge housing.
• Now you can tighten lock nut with a torque wrench to 14 newton meters, then reinstall dome cap, lever screw and hot and cold water indicator.
2. Filtered/Rain Ancillary Outlet
• Remove front button cover using ne-edged 1.2mm screwdriver.
• Unscrew handle then remove cartridge by unscrewing it anti-clockwise, using 5/8” socket. Install cartridge by completing removal instructions as above, in reverse order.
• Ensure cartridge is rmly tightened not over tightened.
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
7
Page 8
TRIPLA T1 Parts Description
1. Handle
2. Screw
3. Screw
4. Cap
Parts Description
5. Handle
6. Cap
7. Plunger
28. Washer
29. Aerator Insert
30. Aerator Cap
38. Handle Cap
41. Battery Seat
11-4 Connector
39. Display
11-3 Inner Tube
31. EPDM washer
32. Aerator Insert
33. Aerator Cap
34. Regular Seat
35. Screw
36. Magnetic Seat
37. Magnet
40. Circuit Board
11-2 Tube
11-1 Body
8. Stem / Cartridge
9. Cover Stem
10. Teflon Washer
11. Spout
12. EPDM Washer
13. EPDM Washer
12. EPDM Washer
10. Teflon Washer
14. Body Stem
15-1 Body
15-2 Nut
16. Rubber Washer
17. Housing
18. Screw
19. Rubber Washer
20. Stainless Washer
21. Brass Nut
45. Flexible Tube ½" Inlet/Outlet Hose
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
8
Page 9
TRIPLA T2 Parts Description
1. Screw
Parts Description
3. Handle
25. EPDM Washer
26. Aerator Insert
27. Aerator Cap
39.
Handle
Cap
36. Display
37.
Screw
9-4. Connector
32. Screw
35.
Handle
Cap
34. Strong Magnet
40. Circuit Board
9-3. Inner Tube
28. EPDM Washer
29. Aerator Insert
30. Aerator Cap
33. Magnet Seat
2. Cap
9-2. Brass Tube
9-1. Body
31. Plunger
4. Cap
5. Plunger
6. Stem / Cartridge
7. Cover Stem
8. Teflon Washer
9. Spout
10. EPDM Washer
11. EPDM Washer
10. EPDM Washer
8. Teflon Washer
12. Body Stem
13-1. Body Stem
13-2. Body Stem
14. EPDM washer
38. O-Ring
44. Flexible Tube ½"
41. Battery Seat
44. Flexible Tube ½"
17. Stainless Washer
18. Brass Nut
15. Screw
16. Rubber Washer
42. Flexible Tube ½"
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
9
Page 10
TRIPLA T3 Parts Description
Parts Description
1. Washer
2. Aerator Insert
3. Aerator Cap
5. Aerator Insert
38. Housing
39. O-Ring
23-4 Connector
4. Washer
6. Aerator Cap
10. Handle Cap
9. Display
15. Circuit Board
14. Battery Seat
23-3 Inner Tube
23-2 Tube
23-1 Body
7. Handle
8. Screw
11. Screw
12. Strong Magnet
13. Magnet Seat
40. Screw
41.
Washer
44. Flexible Tube
23. spout
24. Cap
25. Washer
26. O-Ring
27. O-Ring
28. Body
29. O-Ring
35. Body
36. Nut
37. Stopper
30. Connector
30-2. Cartridge
33. Handle
31. Plunger
32. Cap
8. Screw
34. Canopy
42. Washer
43. Brass Nut
47. Wrench
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
10
Page 11
TRIPLA T4 Parts Description
16. Screw
10. Cap
11. O-Ring
12. Screw
17. Circuit Board
13. Display
14. Handle Cap
15. Washer
20. Magnet Seat
19. Strong Magnet
18. Bat­tery Seat
21. Plunger
22. Turn Stem Body
23. Stem Post
24. Upper
25. Lower
26. Seat
27. Stopper
26. Seat
1-2. Tube
1-1. Body
5. Gasket
6. Washer
7. O-Ring
8. O-Ring 9-1. Washer 9-2. Gasket 9-3. Gasket
28. Screw
29. Body
30. O-Ring
38-1. Body
38-2. Nut
39. Stopper
40. Washer
41. Screw
Parts Description
1. Spout 1-3. Inner Tube
1-4. Connector
2. Washer
3. Aerator Insert
4. Aerator Cap
35. Handle
31. Connector
32. Stem
33. Plunger
34. Cap
36. Screw
37. Handle Cap
42.
Washer
44. Brass Nut
45. Flexible Tube
43. Washer
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
11
Page 12
TRIPLA T5 Parts Description
Parts Description
1. Spout
1-3. Inner Tube
11. O-Ring
12. Screw
17. Circuit Board
10. Cap
18. Battery Seat
22. Turn Stem Body
23. Stem Post
13. Display
21. Plunger
24. Upper
25. Lower
26. Seat
27. Stopper
26. Seat
16. Screw
14. Handle Cap
15. Washer
20. Magnet Seat
19. Strong Magnet
1-2. Tube
1-1. Body
5. Gasket
6. Washer
7. O-Ring
8. O-Ring 9-1. Washer 9-2. Gasket 9-3. Gasket
28. Screw
29. Body
30. O-Ring
38-1. Body
38-2. Nut
39. Stopper
40. Washer
41. Screw
1-4. Connector
2. Washer
3. Aerator Insert
4. Aerator Cap
35. Handle
31. Connector
32. Stem
33. Plunger
34. Cap
36. Screw
37. Handle Cap
42.
Washer
44. Brass Nut
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
12
45. Flexible Tube
43. Washer
Page 13
TRIPLA T6 Parts Description
1-4. Connector
2. Washer
3. Aerator Insert
4. Aerator Cap
5. Washer
6. Filter Net
7. Filter
8. Aerator Cap
Parts Description
1. Spout 1-3. Inner Tube
1-2. Tube
14. O-ring
15. Screw
20. Circuit board
13. Cap
21. Battery Seat
25. Turn Stem Body
26. Stem Post
16. Display
24. Plunger
27. Upper
28. Lower
29. Seat
30. Stopper
29. Seat
19. Screw
17. Handle cap
18. Washer
23. Magnet seat
22. Strong magnet
1-1. Body
9. Gasket
10. Washer
11. O-Ring
12. O-Ring
31. Screw
32. Body
33. O-Ring
41. Body
41-1. Nut
42. Stopper
43. Washer
44. Screw
45.
Washer
38. Handle
34. Connector
35. Stem
36. Plunger
37. Cap
39. Screw
40. Handle Cap
48. Flexible Tube
46. Washer
47. Brass Nut
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
13
Page 14
Notes
The complete range of Puretec products are developed, rened and made to meet and exceed stringent specications for the worldwide market.
Important Note: Sales of products are subject to our Terms & Conditions which are
available upon request. All specications, prices and photos are a guide only and are subject to change without notice. Please ring to conrm details. Do not use products with
microbiological unsafe water without adequate disinfection. Under normal circumstances a pressure limiting valve is not required. If incoming water pressure is excessive it may
however be necessary to install an approved pressure limiting valve. Maximum ow
depends on cartridge, vessel, pressure, impurities etc.
Installation Note: A water lter system/tap, like any product, has a limited life and may
eventually fail. Also sometimes failure happens early due to unforeseen circumstances. To avoid possible property damage, this product should be regularly examined for leakage and/or deterioration and replaced when necessary. A drain pan, plumbed to an
appropriate drain or outtted with a leak detector, should be used in those applications
where any leakage could cause property damage, and/or the water supply should be
turned o if no one is home/present.
Warranty
This warranty commences from the date of purchase. To make a claim under the warranty, take the product and proof of purchase to place where you purchased the product, and they will lodge a Warranty Request with Puretec. In addition to the
guaranties provided under the law, Puretec oer warranties as follows: 6 year warranty
is 1 year parts and labour, plus 5 years parts only.
Puretec will pay your reasonable, direct expenses of claiming under this warranty. You may submit details and proof of your expense claim to place of purchase for consideration.
The warranty only applies if the product was used and/or installed in accordance with the user guide and/or installation instructions. This warranty is given in lieu of all other express or implied warranties and manufacturer shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law.
Applicable to all above, is that the warranties need to be approved by Puretec to ensure product was not incorrectly used, installed or claimed. False and incorrect claims will be pursued at Puretec’s discretion, including chargeable inspection and labour costs incurred.
Installation & Operation Manual Copyright © Puretec Pty Ltd 2019
14
Page 15
Warranty
Warranty/Australia
This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road, Lonsdale SA 5160, telephone no. 1300 140 140 and email at sales@puretec.com.au.
This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Warranty/New Zealand
This warranty is given by Puretec Ltd, Reg. No 4464398, PO Box 875 Cambridge 3450 NZ, telephone no. 0800 130 140 and email at sales@puretec.co.nz.
This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Consumer Guarantees Act. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Register Your Warranty Online
In order to register your warranty online you must do so within 30 days of your product purchase.
Follow these 3 simple steps:
1. Go to puretecgroup.com/warranty
2. Enter the required details and hit submit.
3. You will receive an email conrming your warranty.
Authorization code: 1874752
Terms and conditions apply. Proof of purchase must be retained.
Go to puretecgroup.com for full details.
Copyright © Puretec Pty Ltd 2019 Puretec Tripla™ | Triple Action Tapware
15
Page 16