MATERIALS NEEDED FOR COMMON HVAC INSTALLATIONS
Section of 12" (14" for 1200/2000 units) diameter sheet metal (recommended) or
flex duct. You will need 3' to 6' for most installations.
Section of 10" (14" for 1200/2000 units) diameter sheet metal (recommended) or
flex duct. You will need 6" to 24" for most installations.
12" collar (14" for 1200/2000 units) for connection to return air duct.
10" collar (14" for 1200/2000 units) for connection to fan return side of HVAC unit.
4" by 18" ( 4" by 24" for 1200/2000 units) piece of sheet metal for Air Scoop. Or a
prefabricated damper. This is recommended to be installed with every unit.
Sheet metal screws, duct tape or metal tape. 12 gauge electrical wire for power to
unit.
Thermostat wire.
INSTALLATION OF THE DUCTING
Select the proper location for the attachment of the inlet and discharge ducts. Try to
keep a minimum of 6 feet between the inlet and discharge openings. This will prevent
the Pure Air Systems’ filtration unit from recycling the same air. Cut the openings in the
existing return air duct. We recommend an air scoop be placed inside of the return air
duct so that it directs air into the inlet duct of your filtration system. You can use a
damper as an air scoop. Make sure the damper is angled to direct the air from the return
air duct into the inlet duct of your filtration system.
Use sheet metal screws, duct tape or aluminum tape to attach the duct sections to the
collars on the inlet of the unit and the air return. Make sure there are no air
leaks. Repeat this same procedure for the discharge duct. Make sure all
connections are tight and taped.
ELECTRICAL WIRING & POWER CONNECTION
***WIRING FROM 240 VOLT***
For 240 volt operation you will need to cut the "black jumper wire" that connects pin
1 to pin 2 on the 5 pin white power connector attached to the back end of the motor.
You will also need to insure the transformer is a 240V to 24V and 10VA.
FAILURE TO COMPLETE THIS WIRING CHANGE
WILL RESULT IN DAMAGE TO THE MOTOR.