This manual contains important information that you need to know and
understand in order to protect YOUR SAFETY and to PREVENT
EQUIPMENT PROBLEMS. The following symbols help you recognize this
information. Please read the manual and pay attention to these sections.
Save These Important Safety Instructions!
Read and understand all of these safety instructions. Be
sure to retain them for future use.
WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG
POSSIBILITY OF PERSONAL INJURY OR DEATH IF
INSTRUCTIONS ARE NOT FOLLOWED.
CAUTION: CAUTIONS INDICATE A POSSIBILITY OF
EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT
FOLLOWED.
NOTE: NOTES GIVE HELPFUL INFORMATION
WARNING! IMPROPER OPERATION OR MAINTENANCE
OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY
AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL
WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING
THIS EQUIPMENT. WHEN USING AIR TOOLS, BASIC SAFETY
PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE
THE RISK OF PERSONAL INJURY.
3
7500W Generator
General Precautions
WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN
SEVERE INJURY OR DEATH.
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING
ON.
Carbon Monoxide
When this tool is running, ensure that the area is well ventilated. Never run the
engine in an enclosed area. Run the engine in an open area or with an exhaust
evacuation system in an enclosed area.
WARNING! THE EXHAUST CONTAINS POISONOUS CARBON MONOXIDE
GAS THAT CAN CAUSE LOSS OF CONSCIOUSNESS AND MAY LEAD TO
DEATH.
Gasoline and Oil
This product requires oil and fuel. Attempting to start the engine without oil will ruin
the engine and void the warranty. Work in well ventilated area. Keep cigarettes,
flames or sparks away from the work area or where gasoline is stored.
WARNING! GASOLINE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE
UNDER CERTAIN CONDITIONS. KEEP OUT OF REACH OF CHILDREN.
• Gasoline fuel and fumes are flammable and potentially explosive. Use proper fuel storage and
handling procedures. Always have multiple ABC class fire extinguishers nearby.
• Keep the generator and surrounding area clean at all times.
• Fuel or oil spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per
any local, state, or federal codes and regulations. Store oily rags in a covered metal container.
• Never store fuel or other flammable materials near the generator.
4
Owner’s Manual
General Precautions (cont’d)
Gasoline and Oil (cont’d)
• Do not smoke, or allow sparks, flames or other sources of ignition around the engine and fuel
tank. Fuel vapors are explosive.
• Keep grounded conductive objects, such as tools, away from exposed, live electrical parts and
connections to avoid sparking or arcing. These events could ignite fumes or vapors.
• Do not refill the fuel tank while the engine is running or while the engine is still hot. Do not
operate the generator with known leaks in the fuel system
• Excessive buildup of unburned fuel gases in the exhaust system can create a potentially
explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or
hot engine shutdown. If this occurs, open exhaust system drain plugs, if equipped, and allow the
gases to dissipate before attempting to restart the generator.
• Use only engine manufacturer recommended fuel and oil.
Hot Components
WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY
HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN. WEAR
INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND EXHAUST SYSTEM
HAVE COOLED BEFORE HANDLING THESE PARTS.
Power Output
This generator is not designed to power sensitive electronic equipment (including computers
and medical devices) without the addition of an approved line conditioner, which is sold separately.
CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT
WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE
DAMAGE TO THE EQUIPMENT. ALL POWER AMERICA IS NOT RESPONSIBLE
FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN
APPROVED LINE CONDITIONER.
5
7500W Generator
General Precautions (cont’d)
Work Area
• Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents.
• Do not operate power tools in explosive atmospheres, such as in the presence of flammable
liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes.
• Keep bystanders, children, and visitors away while operating a generator. Provide barriers or
shields as needed.
Electrical Safety
• Grounded tools must be plugged into an outlet properly installed and
grounded in accordance with all codes and ordinances. Never remove the
grounding prong or modify the plug in any way. Do not use any adapter
plugs.
• Grounding provides a low-resistance path to carry electricity away from the
user in the event of an electrical malfunction.
• Double insulated tools are equipped with a polarized plug where one blade is wider than the
other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet.
Do not change the plug in any way. Double insulation eliminates the need for the three-wire
grounded power cord and grounded power supply system.
• Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators.
There is an increased risk of electric shock if your body is grounded.
• Do not expose generator to rain or wet conditions. Water entering a generator will increase the
risk of electric shock.
• Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving
parts. Replace damaged power cords immediately. Damaged power cords increase the risk of
electric shock.
• When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”.
These extension cords are rated for outdoor use, and reduce the risk of electric shock.
6
Owner’s Manual
General Precautions (cont’d)
Electrical Safety (cont’d)
• All connections and conduits from the generator to the load must only be installed by trained and
licensed electricians, and in compliance with all relevant local, state, and federal electrical
codes and standards, and other regulations where applicable.
• The generator must be earth-grounded for fixed installations in accordance with all relevant
electrical codes and standards before operation.
• Do not attempt to connect or disconnect load connections while standing in water, or on wet or
soggy ground.
• Do not touch electrically energized parts of the generator and interconnecting cables or
conductors with any part of the body, or with any non-insulated conductive object.
• Connect the generator only to a load or electrical system (120 volt) that is compatible with the
electrical characteristics and rated capacities of the generator.
• Before servicing equipment powered by the generator, disconnect the equipment from its power
input.
• Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked,
cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded.
Keep terminals clean and tight.
•
Insulate all connections and disconnected wires.
• Guard against electric shock. Prevent body contact with grounded surfaces such as pipes,
radiators, ranges, and refrigerator enclosures.
Personal Safety
• Stay alert. Watch what you are doing, and use common sense when operating a generator. Do
not use generator while tired or under the influence of drugs, alcohol, or medication. A moment
of inattention while operating generators may result in serious personal injury.
Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing,
•
and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in
moving parts.
7
7500W Generator
General Precautions (cont’d)
Personal Safety (cont’d)
• Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect
the spark plug wire when not in use.
•
Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that is
left attached to a rotating part of the generator may result in personal injury.
• Do not overreach. Keep proper footing and balance at all times.
goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for
appropriate conditions.
• Do not force the generator. Use the correct generator for your application. The correct generator
will do the job better and safer at the rate for which it is designed.
• Do not use the generator if the power switch does not turn it on or off. Any generator that cannot
be controlled with the power switch is dangerous and must be replaced.
Generator Use and Care
Make sure the power switch is in its “OFF” position and disconnect the spark plug wire before
making any adjustment, changing accessories, or storing the generator. Such preventive safety
measures reduce the risk of starting the generator accidentally.
Store idle generators out of reach of children and other untrained persons. Generators are
dangerous in the hands of untrained users.
Maintain generators with care. Do not use damaged generator. Tag damaged generators “Do not
use” until repaired.
Check for misalignment or binding of moving parts, breakage of parts, and any other condition that
may affect the generator’s operation. If damaged, have the generator serviced before using. Many
accidents are caused by poorly maintained generators.
Use only accessories that are recommended by the manufacturer for your model. Accessories that
may be suitable for one generator may become hazardous when used on another generator.
8
Owner’s Manual
General Precautions (cont’d)
Servicing
Maintain labels and name plates on the generator and engine. These carry important information.
If unreadable or missing, contact immediately for a replacement.
Generator service must be performed only qualified repair personnel. Service or maintenance
performed by unqualified personnel could result in a risk of injury.
When servicing a generator, use only identical replacement parts. Follow all appropriate
instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions
may create a risk of electric shock or injury.
Heart Pacemakers
WARNING! PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USING THIS PRODUCT. ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE
INTERFERENCE TO OR FAILURE OF THE PACEMAKER.
Pulsar Products Inc.
Installation
• Ensure installation meets all applicable safety, and local and national electrical codes. Have
installation performed by a qualified, licensed electrician and building contractor.
• All electrical work, including the earth-ground connection, should be completed by a licensed
electrician.
• Any separate fuel storage or generator supply facility must be built or installed in full compliance
with all relevant local, state, and federal regulations.
• It is recommended to use the generator only in well ventilated outdoor areas. A running
gasoline engine will generate carbon monoxide, a colorless, odorless gas that, if inhaled, can
cause serious injury or death. If the generator is installed indoors, exhaust fumes must be piped
out of the building using leak-free, heat resistant piping. Pipes and silencer should not use any
flammable materials, nor should they be installed near the same. Generator exhaust fumes
must be within legal imits and installation must always meet local building codes.
9
7500W Generator
General Precautions (cont’d)
Installation (cont’d)
• If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It
should not be run outdoors without protection to the generator and wiring conduit.
• The generator weighs 10 lbs (approx). Two or more people should assist when moving or lifting this
pr
oduct. Never lift the generator using the engine or alternator lifting lugs. Connect lifting
equipment to the frame of the generator
Before lifting the generator, ensure the lift rigging and supporting structure are in good
•
condition, and are rated to lift such a load.
• Keep all personnel away from the suspended generator during relocating.
• The supporting oor/ground surface should be level and strong enough to safely hold the weight
of the generator. If the floor/grounded surface is not level, strong cross members should be
placed under the full length of the generator frame at its low side.
• For trailer installation, the generator should be mounted on the center point of the trailer, over
the wheels. The trailer must be capable of supporting the weight of the generator and all
contents (tools, etc.)
• Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping
moisture within the generator’s area.
fl
5
Mechanical
• Always make sure the power switch is in its “OFF” position. Disconnect the spark plug wire, and
allow the engine to completely cool before carrying out maintenance.
• Check for damaged parts. Before using the generator, any part that appears damaged should
be carefully checked to determine that it will operate properly and perform its intended function.
Check for alignment and binding of moving parts, any broken parts or mounting fixtures, and any
other condition that may affect proper operation technician.
•
The generator is designed with guards for protection from moving parts. In any case, care must
still be taken to protect personnel and equipment from other mechanical hazards when working
around the generator.
10
Owner’s Manual
General Precautions (cont’d)
Mechanical (cont’d)
• Do not operate the generator with safety guards removed. While the generator is running, do not
attempt to reach around the safety guard for maintenance or any other reason.
•
Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that
when engine parts are moving fast they cannot be seen clearly.
•
Keep access doors on enclosures closed and locked when access is not required.
•
When working on or around the generator always wear protective clothing including ANSI
approved safety gloves, safety eye goggles, and safety hat.
•
Do not alter or adjust any part of the generator that is assembled and supplied by the
manufacturer.
•
Always follow and complete scheduled engine and generator maintenance.
Chemicals
• Avoid contact with hot fuel, oil, exhaust fumes, and hot solid surfaces.
•
Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek
medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact,
immediately wash with soap and water. For eye contact, immediately flush eyes with clean water
and seek medical attention.
Noise
• Prolonged exposure to noise levels above 68 DBA is hazardous to hearing. Always wear ANSI
approved ear protection when operating or working around the generator when it is running.
11
12
ene
r
a
l
P
a
t
s
r
General Parts
Fuel tank
Frame
Oil dipstick
Drain plug
Fuel valve
Choke lever
Air filter
Recoil starter
Control Panel
Wheel
Handel
Fuel tank cap
120V outlet
DC terminal
Grounding terminal
AC breaker
AC breaker
AC breaker
Oil alert lamp
On/off switch
Loading...