PSC 1400I User Manual

Magellan® 1400i
Omni-Directional Imaging Scanner
Product Reference Guide
PSC Inc
959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC"). Owners of PSC products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your PSC representative. Electronic versions may either be downloadable from the PSC website (www.psc.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other PSC publications, please let us know via the “Contact PSC” page.
Disclaimer
PSC has taken reasonable measures to provide information in this manual that is complete and accurate, however, PSC reserves the right to change any specification at any time without prior notice.
PSC is a registered trademark of PSC Inc. The PSC logo is a trademark of PSC. All other trademarks and trade names referred to herein are property of their respective owners.
This product may be covered by one or more of the following patents: 4603262 • 4639606 • 4652750 • 4672215 • 4699447 • 4709369 • 4749879 4786798 • 4792666 • 4794240 •
4798943 • 4799164 • 4820911 • 4845349 • 4861972 • 4861973 • 4866257 • 4868836 • 4879456 • 4939355 • 4939356 • 4943127 • 4963719 • 4971176 • 4971177 • 4991692 • 5001406 • 5015831 • 5019697 • 5019698 • 5086879 • 5115120 • 5144118 • 5146463 • 5179270 • 5198649 • 5200597 • 5202784 • 5208449 • 5210397 • 5212371 • 5212372 • 5214270 • 5229590 • 5231293 • 5232185 • 5233169 • 5235168 • 5237161 • 5237162 • 5239165 • 5247161 • 5256864 • 5258604 • 5258699 • 5260554 • 5274219 • 5296689 • 5298728 • 5311000 • 5327451 • 5329103 • 5330370 • 5347113 • 5347121 • 5371361 • 5382783 • 5386105 • 5389917 • 5410108 • 5420410 • 5422472 • 5426507 • 5438187 • 5440110 • 5440111 • 5446271 • 5446749 • 5448050 • 5463211 • 5475206 • 5475207 • 5479011 • 5481098 • 5491328 • 5493108 • 5504350 • 5508505 • 5512740 • 5541397 • 5552593 • 5557095 • 5563402 • 5565668 • 5576531 • 5581707 • 5594231 • 5594441 • 5598070 • 5602376 • 5608201 • 5608399 • 5612529 • 5629510 • 5635699 • 5641958 • 5646391 • 5661435 • 5664231 • 5666045 • 5671374 • 5675138 • 5682028 • 5686716 • 5696370 • 5703347 • 5705802 • 5714750 • 5717194 • 5723852 • 5750976 • 5767502 • 5770847 • 5786581 • 5786585 • 5787103 • 5789732 • 5796222 • 5804809 • 5814803 • 5814804 • 5821721 • 5822343 • 5825009 • 5834708 • 5834750 • 5837983 • 5837988 • 5852286 • 5864129 • 5869827 • 5874722 • 5883370 • 5905249 • 5907147 • 5923023 • 5925868 • 5929421 • 5945670 • 5959284 • 5962838 • 5979769 • 6000619 • 6006991 • 6012639 • 6016135 • 6024284 • 6041374 • 6042012 • 6045044 • 6047889 • 6047894 • 6056198 • 6065676 • 6069696 • 6073849 • 6073851 • 6094288 • 6112993 • 6129279 • 6129282 • 6134039 • 6142376 • 6152368 • 6152372 • 6155488 • 6166375 • 6169614 • 6173894 • 6176429 • 6188500 • 6189784 • 6213397 • 6223986 • 6230975 • 6230976 • 6237852 • 6244510 • 6259545 • 6260763 • 6266175 • 6273336 • 6276605 • 6279829 • 6290134 • 6290135 • 6293467 • 6303927 • 6311895 • 6318634 • 6328216 • 6332576 • 6332577 • 6343741 • 6454168 • 6478224 • 6568598 • 6578765 • 6705527 • 6974084 • 6991169 •7051940 • AU703547 • D312631 • D313590 • D320011 • D320012 • D323492 • D330707 • D330708 • D349109 • D350127 • D350735 • D351149 • D351150 • D352936 • D352937 • D352938 • D352939 • D358588 • D361565 • D372234 • D374630 • D374869 • D375493 • D376357 • D377345 • D377346 • D377347 • D377348 • D388075 • D446524 • EP0256296 • EP0260155 • EP0260156 • EP0295936 • EP0325469 • EP0349770 • EP0368254 • EP0442215 • EP0498366 • EP0531645 • EP0663643 • EP0698251 • GB2252333 • GB2284086 • GB2301691 • GB2304954 • GB2307093 • GB2308267 • GB2308678
• GB2319103 • GB2333163 • GB2343079 • GB2344486 • GB2345568 • GB2354340 • ISR107546 • ISR118507 • ISR118508 • JP1962823 • JP1971216 • JP2513442 • JP2732459 • JP2829331 • JP2953593 • JP2964278 • MEX185552 • MEX187245 • RE37166 • Other Patents Pending
Table of Contents
About This Manual ............................................................................................................... 1-1
Manual Conventions ....................................................................................................... 1-1
Connecting the Scanner ....................................................................................................... 1-2
Programming ..................................................................................................................... 1-3
Using the Programming Bar Codes ................................................................................... 1-3
Resetting the Standard Product Defaults ................................................................................ 1-3
LED and Beeper Indicators ................................................................................................... 1-4
Error Codes ........................................................................................................................ 1-5
Double Read Timeout .......................................................................................................... 2-1
PDF Double Read Timeout .................................................................................................... 2-2
Label Gone Timeout ............................................................................................................ 2-4
PDF Label Gone Timeout ...................................................................................................... 2-4
Sleep Mode ........................................................................................................................ 2-5
LED and Beeper Indicators ................................................................................................... 2-7
Power On Alert .............................................................................................................. 2-7
Good Read: When to Indicate .......................................................................................... 2-8
Good Read Beep Control ................................................................................................. 2-9
Good Read Beep Frequency ............................................................................................ 2-9
Good Read Beep Length ................................................................................................2-10
Good Read Beep Volume ...............................................................................................2-11
Productivity Index Reporting (PIR) .......................................................................................2-11
Scanning Features .............................................................................................................2-12
Aiming Pointer .............................................................................................................2-12
Targeted Scanning Mode ...............................................................................................2-12
Wake Up Intensity ........................................................................................................2-15
Interface Selection .............................................................................................................. 3-3
Interface Features ............................................................................................................... 3-7
RS-232 Interface Features .............................................................................................. 3-9
ACK NAK Error Handling ................................................................................................3-23
IBM-USB Interface Features ...........................................................................................3-24
IBM ............................................................................................................................3-25
Wand Emulation ...........................................................................................................3-26
Keyboard Wedge ..........................................................................................................3-30
USB Keyboard ..............................................................................................................3-30
Data Editing Overview ......................................................................................................... 4-1
Please Keep In Mind... .................................................................................................... 4-1
Global Prefix/Suffix ............................................................................................................. 4-2
AIM ID .............................................................................................................................. 4-4
Label ID ............................................................................................................................ 4-5
Case Conversion ................................................................................................................4-11
Character Conversion .........................................................................................................4-12
UPC-A ............................................................................................................................... 5-1
Disable/Enable UPC-A .................................................................................................... 5-1
Check Digit Transmission ................................................................................................ 5-2
Expand UPC-A to EAN-13 ................................................................................................ 5-2
Number System Transmission ......................................................................................... 5-3
UPC-A Minimum Reads ................................................................................................... 5-3
UPC-A In-store Minimum Reads ....................................................................................... 5-4
UPC-E ............................................................................................................................... 5-5
Disable/Enable UPC-E .................................................................................................... 5-5
Check Digit Transmission ................................................................................................ 5-5
Number System Digit ..................................................................................................... 5-6
Expand UPC-E to UPC-A ................................................................................................. 5-6
Expand UPC-E to EAN13 ................................................................................................. 5-7
Product Reference Guide
i
Minimum Reads ............................................................................................................. 5-7
GTIN ............................................................................................................................5-8
Expand UPC/EAN to GTIN ................................................................................................5-8
EAN-13 ..............................................................................................................................5-9
Disable/Enable EAN-13 ................................................................................................... 5-9
Check Digit Transmission ................................................................................................5-9
EAN-13 Flag 1 Character ............................................................................................... 5-10
ISBN .......................................................................................................................... 5-10
Minimum Reads ........................................................................................................... 5-11
EAN-8 .............................................................................................................................. 5-12
Disable/Enable EAN-8 ................................................................................................... 5-12
Check Digit Transmission .............................................................................................. 5-12
Minimum Reads ........................................................................................................... 5-13
Enable EAN Two-Label ........................................................................................................ 5-14
Enable EAN Two-Label Combined ......................................................................................... 5-14
Add-ons ........................................................................................................................... 5-15
RSS-14 ............................................................................................................................ 5-17
Disable/Enable RSS-14 ................................................................................................. 5-17
RSS-14 UCC/EAN 128 Emulation .................................................................................... 5-17
Minimum Reads ........................................................................................................... 5-18
RSS-14 2D Component ................................................................................................. 5-19
RSS Expanded .................................................................................................................. 5-20
Disable/Enable RSS Expanded ....................................................................................... 5-20
RSS Expanded UCC/EAN 128 Emulation .......................................................................... 5-20
Length Control ............................................................................................................. 5-21
RSS Expanded Length 1, Length 2 Programming Instructions ............................................. 5-22
Minimum Reads ........................................................................................................... 5-23
RSS Expanded 2D Component ....................................................................................... 5-24
RSS Limited ...................................................................................................................... 5-24
Disable/Enable RSS Limited ........................................................................................... 5-24
RSS Limited UCC/EAN 128 Emulation .............................................................................. 5-25
Minimum Reads ........................................................................................................... 5-25
RSS Limited 2D Component ........................................................................................... 5-26
Code 39 ........................................................................................................................... 5-27
Disable/Enable Code 39 ................................................................................................ 5-27
Check Character Calculation .......................................................................................... 5-27
Check Character Transmit ............................................................................................. 5-28
Start/Stop Characters ................................................................................................... 5-28
Code 39 Full ASCII ....................................................................................................... 5-29
Length Control ............................................................................................................. 5-30
Code 39 Length 1, Length 2 Programming Instructions ..................................................... 5-31
Quiet Zones ................................................................................................................ 5-31
Code 39 Stitching ........................................................................................................ 5-32
Minimum Reads ........................................................................................................... 5-32
Pharmacode 39 ................................................................................................................. 5-33
Disable/Enable Pharmacode 39 ...................................................................................... 5-33
Start/Stop Characters ................................................................................................... 5-33
Check Character Transmit ............................................................................................. 5-34
Code 128 and UCC/EAN 128 ............................................................................................... 5-35
Transmit Function Characters ........................................................................................ 5-36
Length Control ............................................................................................................. 5-37
Code 128 Length 1, Length 2 Programming Instructions .................................................... 5-38
Code 128 Conversion to Code 39 ................................................................................... 5-38
Code 128 Stitching ....................................................................................................... 5-39
Minimum Reads ........................................................................................................... 5-39
Interleaved 2 of 5 .............................................................................................................. 5-40
Disable/Enable Interleaved 2 of 5 ................................................................................... 5-40
Check Digit Calculation ................................................................................................. 5-40
Check Digit Transmit .................................................................................................... 5-41
Length Control ............................................................................................................. 5-42
ii Magellan® 1400i
Interleaved 2 of 5 Length 1, Length 2 Programming Instructions .........................................5-43
Interleaved 2 of 5 Stitching ............................................................................................5-44
Minimum Reads ............................................................................................................5-45
Codabar ............................................................................................................................5-46
Disable/Enable Codabar .................................................................................................5-46
Check Character Verification ..........................................................................................5-46
Check Character Transmit ..............................................................................................5-47
Length Control .............................................................................................................5-48
Codabar Length 1, Length 2 Programming Instructions ......................................................5-49
Start/Stop Character Type .............................................................................................5-50
Start/Stop Character Transmission ..................................................................................5-50
Start/Stop Character Match ...........................................................................................5-51
Codabar Stitching .........................................................................................................5-51
Minimum Reads ............................................................................................................5-52
Code 93 ............................................................................................................................5-53
Disable/Enable Code 93 .................................................................................................5-53
Length Control .............................................................................................................5-54
Code 93 Length 1, Length 2 Programming Instructions ......................................................5-55
Code 93 Stitching .........................................................................................................5-56
Minimum Reads ............................................................................................................5-56
MSI/Plessey ......................................................................................................................5-57
Disable/Enable MSI/Plessey ...........................................................................................5-57
Check Digit Verification .................................................................................................5-57
Check Digit Transmit .....................................................................................................5-58
Number of Check Characters ..........................................................................................5-58
Length Control .............................................................................................................5-59
MSI/Plessey Length 1, Length 2 Programming Instructions .................................................5-60
MSI/Plessey Stitching ....................................................................................................5-61
Minimum Reads ............................................................................................................5-62
Standard 2 of 5 .................................................................................................................5-63
Disable/Enable Standard 2 of 5 ......................................................................................5-63
Check Digit Verification .................................................................................................5-63
Check Digit Transmit .....................................................................................................5-64
Length Control .............................................................................................................5-65
Standard 2 of 5 Length 1, Length 2 Programming Instructions ............................................5-66
Standard 2 of 5 Stitching ...............................................................................................5-67
Minimum Reads ............................................................................................................5-68
PDF417 ............................................................................................................................5-69
Disable/Enable PDF417 .................................................................................................5-69
PDF417 Minimum Reads ................................................................................................5-69
Length Control .............................................................................................................5-70
PDF417 Length 1, Length 2 Programming Instructions .......................................................5-71
Micro PDF417 ....................................................................................................................5-72
Disable/Enable Micro PDF417 .........................................................................................5-72
Micro PDF 128 Emulation ...............................................................................................5-73
Micro PDF417 Minimum Reads ........................................................................................5-74
Length Control .............................................................................................................5-75
Micro PDF417 Length 1, Length 2 Programming Instructions ..............................................5-76
Optical and Read Performance Parameters ............................................................................. A-1
Scanner Dimensions ............................................................................................................ A-1
Physical Properties .............................................................................................................. A-2
Electrical Parameters ........................................................................................................... A-2
Environmental Parameters ................................................................................................... A-2
Other Parameters ...............................................................................................................A-2
Standard Cable Pinouts (Primary Interface Cables) .................................................................. B-1
RS-232 ........................................................................................................................ B-1
IBM Port 5B/9B/17 ........................................................................................................ B-1
IBM USB ...................................................................................................................... B-2
USB & USB Keyboard ..................................................................................................... B-2
Wand Emulation ............................................................................................................ B-2
Product Reference Guide
iii
Keyboard Wedge ............................................................................................................B-2
Standard Feature Defaults ................................................................................................... D-1
Keyboard Model Cross Reference ...........................................................................................E-1
Accepting RS-232 Commands ............................................................................................... F-1
iv Magellan® 1400i
®
The Magellan easily handled items and handheld scanning for bulkier items. Its aggressive imaging perfor­mance and intuitive operation reduces user training and speeds checkout for better customer service.
1400i Omni-Directional Imaging Scanner offers hands-free scanning for small,

About This Manual

This manual presents advanced user information which includes connection, programming, product and cable specifications, and other useful references. For additional information, such as installation, maintenance, troubleshooting and warranty information, see the Quick Refer­ence Guide (QRG). Copies of other publications for this product are downloadable free of charge from the PSC website listed on the back cover of this manual.
On leaving the factory, units are programmed for the most common terminal and communica­tions settings. If you need to change these settings, custom programming can be accomplished by scanning the bar codes in this guide.
Chapter 1

Getting Started

Bold text and a yellow-highlighted background indicates the most common default setting for a feature/option.

Manual Conventions

The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the scanner:
NOTE
CAUTION
Notes contain information necessary for prop­erly diagnosing, repairing and operating the scanner.
The CAUTION symbol advises you of actions that could damage equipment or property.
Product Reference Guide
1-1
Getting Started

Connecting the Scanner

The scanner kit you ordered to match your interface should provide a compatible cable for your installation. Use the appropriate instructions below to connect the scanner to the terminal, PC or other host device.
Upon completing the connection via the appropriate interface instructions below, proceed to
Interface Related Features section of this manual and scan the bar code to select the correct
the interface type.
RS-232 Serial Connection —
to the terminal/PC serial port via the RS-232 cable as shown in
Turn off power to the terminal/PC and connect the scanner
Figure 1. If the terminal will not
support POT (Power Off the Terminal) to supply scanner power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable con­nector and the AC Adapter plug into a standard power outlet.
Figure 1
USB Connection —
USB cable for the interface type you ordered. Reference
. RS-232 Serial or USB Connection using A/C Adapter
I/F Cable
Connect
Here
To Host/Terminal
A/C Adapter (if needed)
Connect the scanner to a USB port on the terminal/PC using the correct
Figure 1 and Figure 2.
USB installations may require a power connection via
NOTE
an approved A/C Adapter as shown in example, this would be the case if the scanner is con­nected along with a number of other devices to a non­powered USB hub.
Figure 1. For
For 220-230 VAC adapters, the cord must be facing down as shown in the illustration. If installed upwards, it will pose an undue strain on the socket outlet.
Figure 2. Other Connection Types
B
S
K
U
e
y
W
b
o
e
a
d
r
(Decoder required for Wand Emulation)
or...
d
n
a
W
M
B
I
or...
d
g
e
1-2 Magellan® 1400i

Programming

Wand Emulation Connection —
nal/PC via a decoder
Figure 2.
IBM Connection —
rect IBM cable. Reference
Keyboard Wedge Connection —
1
using the correct cable for the interface type you ordered. Reference
Connect the scanner to the IBM port on the terminal/PC using the cor-
Figure 2.
Connect the scanner to the appropriate port on the termi-
Before connection, turn off power to the terminal/PC. The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference
Figure 2.
Programming
The scanner is typically factory-configured with a set of default features standard to the interface type you ordered. After scanning the interface bar code from the tion, you can select other options and customize your scanner through use of the instructions and programming bar codes available in that section and also the chapters of this manual.

Using the Programming Bar Codes

This manual contains feature descriptions and bar codes which allow you to reconfigure your scanner. Some programming bar code labels, like the label below for resetting defaults, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the scanner to be placed in Programming Mode prior to scanning them. Scan a START/END bar code once to enterProgramming Mode. Once the scanner is in Programming Mode, you can scan a number of parameter settings before scanning the START/ END bar code a second time, which will then accept your changes, exit Programming Mode and return the scanner to normal operation.
Interface Related Features sec-
Data Editing and Symbologies

Resetting the Standard Product Defaults

If you are unsure of what programming options are in your scanner, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below (you do not have to scan START/END bar codes when scanning the Standard Prod­uct Default Settings bar code). This will copy the factory configuration for the currently active interface to the current configuration.
Standard Product Default Settings
The programming section lists the factory default settings for each of the menu commands for the standard RS-232 interface in tings for the other interfaces can be found in
1. Wand Emulation requires a decoder.
Product Reference Guide
BOLD text on the following pages. Exceptions to default set-
Appendix D, Default Settings.
1-3
Getting Started

LED and Beeper Indicators

The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming bar code labels.
Green LED Indications
LED
INDICATION
Power-on indication
Good Read Indication
Scanner Ready Constant dim green The scanner is ready for operation.
Sleep Mode
Host Disable
Diagnostics
BEEPER FUNCTIONS
BEEPER
INDICATION
Bright green flash
Bright green flash Indicates a bar code has been read and decoded.
Constant green flash (100mS on, 1900mS off)
Constant green flash at 1 Hz (100mS on, 900mS off)
Varies (see "Error Codes" on page 1-5 for more information)
INDICATION COMMENT
Indicates the scanner has finished all its power up tests and is now ready for ooperation.
The scanner is in Sleep Mode. To wake the scanner up, move an object in front of its window or press the button atop the unit.
The scanner is disabled due to receiving a disble command from the POS terminal.
The LED can provide diagnostic feedback if the scanner dis­covers a problem during SelfTest.
INDICATION COMMENT
The Power-On LED indication is a configurable feature which
Power On Beep Single beep
Good Read Indication
Diagnostics
Programming Mode Indications
1-4 Magellan® 1400i
Single beep
Varies (see "Error Codes" on page 1-5 for more information)
Varies (see the Product Reference Guide for more information about scanner programming)
can be enabled or disabled. When enabled, this beep Indi­cates the scanner has finished all its power up tests and is now ready for operation.
The good read beep indication is configurable. Options include: Enable/disable, frequency, duration and volume. See the Product Reference Guide (PRG) for more information.
The Beeper can provide diagnostic feedback if the scanner discovers a problem during SelfTest.
The Beeper will sound as programming bar code labels are scanned, indicating progress during scanner configuration.

Error Codes

Upon startup, if the scanner flashes its indicator LED or sounds an unexpected series of beep tones (other than normal power-up indications), this means the scanner has not passed its auto­matic Selftest and has entered FRU pressed, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found.
NUMBER OF
LED FLASHES/
ERROR CORRECTIVE ACTION
BEEPS
1 Configuration
2 Interface PCB
6 Main PCB
10 Button Error
Error Codes
1
isolation mode. If the scanner is reset or the button is
11
12
13
14
Near Field Imager Module
Far Fiel d Imager Module
Software ID Failure
CPLD/Code Mismatch
Contact Helpdesk for assistance
1. Field Replaceable Unit (FRU)
Product Reference Guide
1-5
Getting Started
NOTES
1-6 Magellan® 1400i

Double Read Timeout

The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession).
0.1 Second
Chapter 2

General Features

START / END
PROGRAMMING BAR CODES
0.3 Second
0.5 Second
0.2 Second
0.4 Second
0.6 Second DEFAULT
Product Reference Guide
2-1
General Features
Double Read Timeout — cont.
PROGRAMMING BAR CODES
0.7 Second
0.9 Second
START / END
0.8 Second

PDF Double Read Timeout

This double read timer value is used ONLY when scanning PDF417 bar codes.
NOTE
The PDF Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same PDF417 label again (e.g. two identical PDF417 bar codes in suc­cession).
PROGRAMMING BAR CODES
1 Second
START / END
1.5 Seconds
2-2 Magellan® 1400i
Read Timeout
PDF Double Read Timeout — cont.
PROGRAMMING BAR CODES
1.8 Seconds DEFAULT
PDF Double
START / END
1.6 Seconds
1.9 Seconds
2 Seconds
2.2 Seconds
2.4 Seconds
2.1 Seconds
2.3 Seconds
2.55 Seconds
Product Reference Guide
2-3
General Features

Label Gone Timeout

This feature sets the time after the last label segment is seen before the scanner prepares for a new label.
START / END
PROGRAMMING BAR CODES Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim­eout,” followed by three digits (zero padded) from the Alphanumeric table in desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 200 milliseconds (020)
Appendix C, Alpha-Numeric Pad representing the
Set Label Gone Timeout

PDF Label Gone Timeout

This setting specifies how long the Label Gone Timeout timer runs when specifically collecting PDF label segments prior to discarding data.
START / END
PROGRAMMING BAR CODES Sets the label gone timeout duration using hex values from 001 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set PDF Label Gone Timeout,” followed by three digits (zero padded) from the Alphanumeric table in desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 1.5 Seconds (150)
Appendix C, Alpha-Numeric Pad representing the
Set PDF Label Gone Timeout
2-4 Magellan® 1400i

Sleep Mode

This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode.
Sleep Mode
START / END
PROGRAMMING BAR CODES
15 Seconds
DEFAULT
30 Seconds
1 Minute
3 Minutes
5 Minutes
2 Minutes
4 Minutes
Product Reference Guide
2-5
General Features
Sleep Mode — cont.
START / END
7 Minutes
PROGRAMMING BAR CODES
6 Minutes
8 Minutes
9 Minutes
12 Minutes
30 Minutes
10 Minutes
DEFAULT
15 Minutes
1 Hour
2-6 Magellan® 1400i
Beeper Indicators

LED and Beeper Indicators

Power On Alert

Disables or enables the indication (a single beep) that the scanner has finished all its power up tests and is now ready for operation.
PROGRAMMING BAR CODES
Disable
LED and
START / END
Enable
DEFAULT
Product Reference Guide
2-7
General Features

Good Read: When to Indicate

This feature specifies when the scanner will provide indication (beep and/or flash its green LED) upon successfully reading a bar code. Choices are:
Good Read = Indicate after decode
Good Read = Indicate after transmit
Good Read = Indicate after CTS goes inactive, then active
This option (Indicate after CTS goes inactive, then active), which uses CTS, is only valid for RS-232 inter­faces.
NOTE
PROGRAMMING BAR CODES
START / END
After Decode
DEFAULT
After CTS goes inactive, then active
After Transmit
2-8 Magellan® 1400i
Beeper Indicators

Good Read Beep Control

This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code.
Disable
LED and
START / END
PROGRAMMING BAR CODES
Enable
DEFAULT

Good Read Beep Frequency

Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.)
PROGRAMMING BAR CODES
Low
High
START / END
Medium
DEFAULT
Product Reference Guide
2-9
General Features

Good Read Beep Length

Specifies the duration of a good read beep.
60msec
DEFAULT
100msec
START / END
PROGRAMMING BAR CODES
80msec
140msec
180msec
120msec
160msec
200msec
2-10 Magellan® 1400i
ty Index Reporting (PIR)

Good Read Beep Volume

Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
Low
High
DEFAULT
Productivi-
START / END
PROGRAMMING BAR CODES
Medium

Productivity Index Reporting (PIR)

When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer, indicating how easy the label was to read.
This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced
NOTE
Disable
DEFAULT
capability.
PROGRAMMING BARCODES
START / END
Enable
Product Reference Guide
2-11
General Features

Scanning Features

Aiming Pointer

This feature enables/disables the Aiming Pointer for all symbologies.
START / END
PROGRAMMING BAR CODES
Enable always on

Targeted Scanning Mode

Disable
DEFAULT
Upon pressing the button, the scanner will project an aiming pattern to assist in centering over the bar code. Scanning then takes place as soon as the button is released.
When add-ons are enabled and a bar code is being read while in Targeted Mode, position the pointer at or near the end of the base label to ensure the scanner will read both the base and add-on label.
NOTE
Targeted Scanning Mode will read bar codes in any orientation.
The scanner will return to full pattern Omni-directional Mode after either of the following has ocurred:
- Good Read +
-
Target Mode: Active Time + Target Mode: Linger Time has elapsed.
Target Mode: Linger Time has elapsed.
Configuration options for Targeted Scanning Mode are:
Target Mode: Active Time
Target Mode: Linger Time
2-12 Magellan® 1400i
Features
Scanning
Target Mode: Active Time
Specifies the time duration the scanner attempts to decode labels while in the targeted mode of operation.
START / END
PROGRAMMING BAR CODES
Extra Short Duration
Short Duration
Medium Duration
DEFAULT
Long Duration
Product Reference Guide
2-13
General Features
Target Mode: Linger Time
Specifies the time duration the scanner remains in the targeted mode of operation after reading a bar code or after Mode. The linger timer starts upon a good read or upon timeout of whichever is earliest. A button press at any time will reset the process back to the start.
NOTE
START / END
Target Mode: Active Time has expired, before reverting to Omni-directional
Target Mode: Active Time;
Active Time and Linger Time settings are totally indepen­dent from one another.
During the period Linger Time is active, no bar codes can be read, no matter what mode the scanner is in.
PROGRAMMING BAR CODES
Short Duration
Medium Duration
DEFAULT
Long Duration
2-14 Magellan® 1400i
Features

Wake Up Intensity

This feature indicates the percentage of ambient light change which will trigger the scanner to wake up from Sleep Mode. Lower settings provide greater sensitivity.
5%
10%
DEFAULT
Scanning
START / END
PROGRAMMING BAR CODES
8%
20%
30%
15%
25%
35%
Product Reference Guide
2-15
General Features
Wake Up Intensity — cont.
PROGRAMMING BAR CODES
40%
60%
START / END
50%
70%
80%
2-16 Magellan® 1400i
Chapter 3

Interface Related Features

At the time of this writing, the Scanner supports the interfaces listed in Ta bl e 3 - 1 . Select the desired interface type from the table, then reference the page number given for the customizable features section associated with each interface. See Wedge interface type (A through Y as listed).
Table 3-1. Interfaces Supported
RS-232 Page Keyboard Wedge Page
RS-232 Standard
RS-232 Wincor-Nixdorf
IBM
IBM 4683 Port 5B
IBM 4683 Port 9B
IBM 4683 Port 17
USB
IBM USB
USB Keyboard
Wand Emulation
Wand Emulation 3-26
Keyboard Wedge 3-30
Keyboard Wedge A
Keyboard Wedge B
Keyboard Wedge C
Keyboard Wedge D
Keyboard Wedge E
Keyboard Wedge F
Keyboard Wedge G
a. Consult Ta bl e for more information regarding keyboard interface types.
a
a
a
a
a
a
a
3-9
3-9
3-24
3-24
3-24
3-24
3-24
3-30
3-30
3-30
3-30
3-30
3-30
3-30
Ta bl e 3 -2 for a description of each Keyboard
Keyboard Wedge H
Keyboard Wedge I
Keyboard Wedge J
Keyboard Wedge K
Keyboard Wedge L
Keyboard Wedge M
Keyboard Wedge N
Keyboard Wedge N
Keyboard Wedge O
Keyboard Wedge P
Keyboard Wedge Q
Keyboard Wedge R
Keyboard Wedge S
Keyboard Wedge T
Keyboard Wedge U
Keyboard Wedge V
Keyboard Wedge W
Keyboard Wedge X
Keyboard Wedge Y
a
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
NOTE
Product Reference Guide
The correct interface cable is included for the scanner interface type you ordered.
3-1
Interface Related Features
Table 3-2. Keyboard Wedge Interface Reference
I/F Type PCs Supported
A PC/XT w/Alternate Key Encoding
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key
B
Encoding C PS/2 25 and 30 w/Alternate Key Encoding D PC/XT w/Standard Key Encoding
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key E
Encoding F PS/2 25 and 30 w/Standard Key Encoding G IBM 3xxx w/122 keyboard H IBM 3xxx w/102 keyboard
I PS/55 5530T w/104 keyboard
J NEC 9801
K WYSE 30/30+ WY-30 Keyboard 83 Keys
WYSE 60/85/99 GT/150/160/285 Style IBM Enhanced PC, 520/520ES L
Style IBM Enhanced PC FR
WYSE 55/65/65 ES/120/185/325 Style IBM Enhanced PC
WYSE 60/85/99 GT/150/160/285 ANSI Keyboard 105 Keys, 520/520 ES
M
ANSI Keyboard 105 Keys
WYSE 55/65/65 ES/120/185/325 ANSI Keyboard 105 Keys
WYSE 60/85/99 GT/150/160/285 ASCII Kbd, 520/520 ES ASCII Kbd
N
WYSE 55/65/65 ES/120/185/325 ASCII Keyboard
WYSE 60/85/99 GT/150/160/285 ANSI W285 Keyboard 105 Keys, 520/
O
520 ES ANSI W285 Keyboard 105 Keys
WYSE 55/65/65 ES/120/185/325 ANSI W285 Keyboard 105 Keys P WYSE WINTERM 3320 SE
IBM 3153
Q
IBM 316X, 3179/3180/319X/3270
R IBM 3151/3152-010, 347X/348X
S DIGITAL VT 220/320/330/340/350/382 T DIGITAL VT420
U DIGITAL VT 510/520 IBM ANSI Style Keyboard
V DIGITAL VT 510/520 IBM PC Style Keyboard
W SUN SPARC 5/10
X SUN 420/440, ITX Y WYSE 370/355 Style Enhanced IBM PC
Reference
pings for more information about keyboards.
Appendix E, Keyboard Function Key Map-
NOTE
3-2 Magellan® 1400i
Selection

Interface Selection

START / END
RS-232 Wincor-Nixdorf
Interface
PROGRAMMING BAR CODES
RS-232 Standard
IBM 4683 Port 5B
IBM 4683 Port 9B
IBM USB
Wand Emulation
IBM 4683 Port 17
USB Keyboard
Keyboard Wedge A
Product Reference Guide
3-3
Interface Related Features
Interface Selection — cont.
START / END
PROGRAMMING BAR CODES
Keyboard Wedge C
Keyboard Wedge E
Keyboard Wedge B
Keyboard Wedge D
Keyboard Wedge G
Keyboard Wedge I
Keyboard Wedge F
Keyboard Wedge H
Keyboard Wedge J
3-4 Magellan® 1400i
Selection
Interface Selection — cont.
PROGRAMMING BAR CODES
Keyboard Wedge K
Keyboard Wedge M
Interface
START / END
Keyboard Wedge L
Keyboard Wedge O
Keyboard Wedge Q
Keyboard Wedge S
Keyboard Wedge N
Keyboard Wedge P
Keyboard Wedge R
Product Reference Guide
3-5
Interface Related Features
Interface Selection — cont.
PROGRAMMING BAR CODES
Keyboard Wedge T
Keyboard Wedge V
START / END
Keyboard Wedge U
Keyboard Wedge X
Keyboard Wedge W
Keyboard Wedge Y
3-6 Magellan® 1400i
Features

Interface Features

Obey/Ignore Host Commands
When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active and transmit labels For normal operation of the interface, select Obey Host Commands.
START / END
Interface
PROGRAMMING BAR CODES
Obey Host Commands
DEFAULT
Ignore Host Commands
Product Reference Guide
3-7
Interface Related Features
Interface Features — cont.
Host Transmission Buffers
Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted.
When a DISABLE SCANNER command is received from the host, the scanner will continue to transmit all data that is buffered.
START / END
PROGRAMMING BAR CODES
Host Transmission Buffers = 1
Host Transmission Buffers = 2
DEFAULT
3-8 Magellan® 1400i
Features

RS-232 Interface Features

START / END
PROGRAMMING BAR CODES
2400 Baud
9600 Baud
DEFAULT
Interface
1200 Baud
4800 Baud
38400 Baud
115200 Baud
19200 Baud
57600 Baud
Product Reference Guide
3-9
Interface Related Features
RS-232 Interface Features — cont.
START / END
PROGRAMMING BAR CODES
8 Data Bits
DEFAULT
7 Data Bits
1 Stop Bit
DEFAULT
2 Stop Bits
Parity = Even
Parity = None
DEFAULT
Parity = Odd
3-10 Magellan® 1400i
Features
RS-232 Interface Features — cont.
Hardware Flow Control
Interface
Disable Hardware Control—
The scanner transmits to the host regardless of any activity on
the CTS line.
Enable CTS Flow Control—
Enable CTS Scan Control—
The CTS signal controls transmission of data to the host.
The CTS line must be active for the scanner to read and trans­mit data. While the CTS line is inactive, the scanner remains in a host-disabled state; following a successful label transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next label.
START / END
PROGRAMMING BAR CODES
Disable Hardware Control
DEFAULT
Enable CTS Flow Control
Enable CTS Scan Control
Product Reference Guide
3-11
Interface Related Features
RS-232 Interface Features — cont.
Intercharacter Delay
This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.
START / END
PROGRAMMING BAR CODES
Interchar Delay = 10 msec
Inter-Char Delay = No Delay
DEFAULT
Interchar Delay = 30 msec
Interchar Delay = 50 msec
Interchar Delay = 70 msec
Interchar Delay = 20 msec
Interchar Delay = 40 msec
Interchar Delay = 60 msec
3-12 Magellan® 1400i
Features
Intercharacter Delay — cont.
START / END
PROGRAMMING BAR CODES
Interchar Delay = 90 msec
Software Flow Control
Disables/Enables software control using XON/XOFF characters.
START / END
Interface
Interchar Delay = 80 msec
Enable Software Flow Control
PROGRAMMING BAR CODES
Disable Software Flow Control
DEFAULT
Product Reference Guide
3-13
Interface Related Features
RS-232 Interface Features — cont.
Host Echo
When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If, for example, one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission to the host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set
RS-232 Host Echo Quiet Interval). The scanner can be set to observe this delay before sending its
via data in order to avoid RS-232 transmission conflicts.
START / END
PROGRAMMING BAR CODES
Disable Host Echo
DEFAULT
Enable Host Echo
3-14 Magellan® 1400i
Features
RS-232 Interface Features — cont.
Host Echo Quiet Interval
This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host.
START / END
PROGRAMMING BAR CODES
Host Echo Quiet Interval = 10msec
DEFAULT
Interface
Host Echo Quiet Interval = 0msec
Host Echo Quiet Interval = 30msec
Host Echo Quiet Interval = 50msec
Host Echo Quiet Interval = 70msec
Host Echo Quiet Interval = 20msec
Host Echo Quiet Interval = 40msec
Host Echo Quiet Interval = 60msec
Product Reference Guide
3-15
Interface Related Features
Host Echo Quiet Interval — cont.
START / END
Host Echo Quiet Interval = 90msec
PROGRAMMING BAR CODES
Host Echo Quiet Interval = 80msec
Host Echo Quiet Interval = 100msec
Signal Voltage: Normal/TTL
Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.
START / END
PROGRAMMING BAR CODES
Signal Voltage: Normal RS-232
DEFAULT
Signal Voltage: TTL
3-16 Magellan® 1400i
Features
RS-232 Interface Features — cont.
RS-232 Invert
Enables/disables inversion of RS-232 TXD and RXD signals.
START / END
PROGRAMMING BAR CODES
Enable RS-232 Invert
Interface
Disable RS-232 Invert
DEFAULT
Beep on ASCII BEL
Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex).
START / END
PROGRAMMING BAR CODES
Enable Beep on ASCII BEL
DEFAULT
Disable Beep on ASCII BEL
Product Reference Guide
3-17
Interface Related Features
RS-232 Interface Features — cont.
Beep on Not on File
Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host.
START / END
PROGRAMMING BAR CODES
Enable Beep on Not On File
DEFAULT
Disable Beep on Not On File
3-18 Magellan® 1400i
Features
RS-232 Interface Features — cont.
ACK NAK Options
This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are:
•Disable
Enable for label transmission — the scanner expects an ACK/NAK response from the host when a label is sent
Enable for host-command acknowledge — the scanner will respond with ACK/NAK when the host sends a command
Enable for label transmission and host-command acknowledge
START / END
Interface
PROGRAMMING BAR CODES
Enable ACK NAK for Transmission
Enable ACK NAK for transmission and host command
Disable ACK NAK
DEFAULT
Enable ACK NAK for host command acknowledge
Product Reference Guide
3-19
Interface Related Features
RS-232 Interface Features — cont.
ACK Character
START / END
PROGRAMMING BAR CODES Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode,
then the “Set ACK Character,” followed by the digits from the Alphanumeric table in your desired character. Exit programming mode by again scanning the “START/END” bar code above.
DEFAULT SETTING FOR THIS FEATURE: 006 (ACK)
Appendix C, Alpha-Numeric Pad representing
Set ACK Character
NAK Character
START / END
PROGRAMMING BAR CODES Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in your desired character. Exit programming mode by again scanning the “START/END” bar code above.
DEFAULT SETTING FOR THIS FEATURE: 021 (!)
Appendix C, Alpha-Numeric Pad representing
Set NAK Character
3-20 Magellan® 1400i
Features
RS-232 Interface Features — cont.
Retry on ACK NAK Timeout
Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following fea­ture) has expired.
START / END
PROGRAMMING BAR CODES
Enable Retry on ACK NAK Timeout
DEFAULT
Interface
Disable Retry on ACK NAK Timeout
ACK NAK Timeout Value
START / END
PROGRAMMING BAR CODES This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. 000 = Infinite timeout 001 - 075 = Timeout in 200-millisecond increments To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK NAK Timeout Value,” followed by the two digits (zero padded) from the Alphanumeric table in senting your desired value. Exit programming mode by again scanning the “START/END” bar code above.
DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec)
Appendix C, Alpha-Numeric Pad repre-
Set ACK NAK Timeout Value
Product Reference Guide
3-21
Interface Related Features
RS-232 Interface Features — cont.
ACK NAK Retry Count
START / END
PROGRAMMING BAR CODES This feature sets the number of times for the scanner to retry a label transmission under a retry condition. 000 = No retry 001 - 254 = Retry for the specified number of times 255 = Retry forever To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK NAK Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in senting your desired retry count. Exit programming mode by again scanning the “START/END” bar code above
DEFAULT SETTING FOR THIS FEATURE: 003
Appendix C, Alpha-Numeric Pad repre-
Set ACK NAK Timeout Value
3-22 Magellan® 1400i
Features
RS-232 Interface Features — cont.

ACK NAK Error Handling

This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and com­munication errors such as parity or framing errors. Choices are:
00 = Ignore errors detected (recommended setting)
01 = Process error as valid ACK character (risk of lost label data)
02 = Process error as valid NAK character (risk of duplicate label data)
START / END
PROGRAMMING BAR CODES
Interface
Ignore Errors Detected
DEFAULT
Process error as valid ACK character
Process error as valid NAK character
Product Reference Guide
3-23
Interface Related Features
RS-232 Interface Features — cont.
Transmission Failure Indication
Enables/disables bad-label indication upon transmission failure.
START / END
PROGRAMMING BAR CODES
Enable Transmission Error Indication
DEFAULT
Disable Transmission Error Indication

IBM-USB Interface Features

IBM-USB Device usage
The IBM-USB protocol allows for the scanner to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all devices to communicate. Options are:
Table Top Scanner
Handheld Scanner
START / END
PROGRAMMING BAR CODES
Configure as Handheld Scanner
DEFAULT
Configure as Table Top Scanner
3-24 Magellan® 1400i
Features
IBM
Interface
IBM Transmit Labels in Code 39 Format
This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Coda­bar and Code 93 for IBM USB; Code 128, Codabar and Code 93 for IBM Port 5B; and Coda­bar and Code 93 for IBM Port 9B.
START / END
PROGRAMMING BAR CODES
Disable Convert to Code 39
DEFAULT
Enable Convert to Code 39
Product Reference Guide
3-25
Interface Related Features

Wand Emulation

Supported Symbologies
The Wand Emulation interface will transmit bar code data as a wand device would. This inter­face will transmit the following bar code symbologies:
•UPC/EAN
UPC/EAN with addons
•Code 39
Full ASCII Code 39
Interleaved 2 of 5
Codabar
Code 128
Pharmacode 39 is transmitted as Code 39. All other bar code symbology types read by the scan­ner will be transmitted as Code 128.
Wand Emulation Bar Code Format
The following format settings are required for the wand emulation interface. These settings have been pre-configured at the factory for Wand Emulation scanners.
UPC-A bar codes must include all 12 digits.
UPC-E bar codes must contain 8 digits, including a system digit, 6 data digits, and the check digit.
EAN-13 bar codes must have all 13 digits.
EAN-8 bar codes must include all 8 digits.
Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must NOT contain start / stop characters.
Codabar bar codes must include the start / stop characters, presented in the ABCD for­mat.
Interleaved 2 of 5 bar codes must have an even number of digits.
3-26 Magellan® 1400i
Features
Wand Emulation — cont.
Bar/Space Polarity
Low/High — Black will be transmitted as a low voltage level (0 to +0.7V) and space as high
level (+2.4 to +5.25V).
High/Low — Black will be transmitted as a high voltage level (+2.4 to +5.25V) and space as
low level (0 to +0.7V).
START / END
Interface
PROGRAMMING BAR CODES
Bar/Space = Low/High
Bar/Space = High/Low
DEFAULT
Wand Idle State
This feature specifies the level of the wand output signal when idle. TTL logic levels:
High voltage level (+2.4 to +5.25V)
Low voltage level (0 to +0.7V).
START / END
PROGRAMMING BAR CODES
Wand Idle State = Low
DEFAULT
Wand Idle State = High
Product Reference Guide
3-27
Interface Related Features
Wand Emulation — cont.
Signal Speed
The speed of the transmission can be set. This selects the width of the minimum narrow bar.
330 microseconds
660 microseconds
START / END
Signal Speed = 660mS
DEFAULT
PROGRAMMING BAR CODES
Signal Speed = 330mS
Transmit Trailing Noise
The transmission of noise pulses after the label may be enabled or disabled.
START / END
PROGRAMMING BAR CODES
Disable Trailing Noise
Enable Trailing Noise
DEFAULT
3-28 Magellan® 1400i
Features
Wand Emulation — cont.
Transmit Leading Noise
The transmission of noise pulses before the bar code may be enabled or disabled.
START / END
Enable Leading Noise
DEFAULT
Interface
PROGRAMMING BAR CODES
Disable Leading Noise
Symbology Conversion
Wand Emulation can convert all bar codes to a single symbology. Choices are:
No Conversion
Convert to Code 39
Convert to Code 128
START / END
PROGRAMMING BAR CODES
No Symbology Conversion
DEFAULT
Convert to C39
Convert to C128
Product Reference Guide
3-29
Interface Related Features

Keyboard Wedge

and

USB Keyboard

As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The instal­lation of the wedge is a fairly simple process that doesn’t require any changes of software or hard­ware.
NOTE
Keyboard Layout
The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual.
START / END
All of the options in this section apply to the Key­board Wedge, however, only some apply to USB Key­board.
Belgium
Denmark
PROGRAMMING BAR CODES
USA
DEFAULT
Britain
France
Germany
3-30 Magellan® 1400i
Features
Keyboard Wedge — cont.
START / END
PROGRAMMING BAR CODES
Norway
Interface
Italy
Portugal
Spain
Switzerland
Hungary
Sweden
Japan 106 Key
Czech
Product Reference Guide
3-31
Interface Related Features
Keyboard Wedge — cont.
START / END
PROGRAMMING BAR CODES
Romania
Poland
Slovakia
Croatia
Caps Lock State
Specifies the format in which the scanner sends character data.
START / END
PROGRAMMING BAR CODES
Disable Caps Lock
Caps Lock “ON”
Shift Lock “ON”
DEFAULT
3-32 Magellan® 1400i
Features
Keyboard Wedge — cont.
Power-On Simulation
This feature does not apply to the USB Keyboard interface.
NOTE
All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on.
START / END
PROGRAMMING BAR CODES
Interface
Disable Power-on Simulation
DEFAULT
Enable Power-on Simulation
Product Reference Guide
3-33
Interface Related Features
Keyboard Wedge — cont.
Control Characters
Specifies how the scanner transmits ASCII control characters to the host. Choices are:
Disable Control Characters
Enable transmission of control characters to host
Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is pro­vided for each available scancode set. Reference
pings.)
START / END
PROGRAMMING BAR CODES
Appendix E, Keyboard Function Key Map-
Disable Control Characters
DEFAULT
Enable Transmission of Control Characters
Enable Function Key Mapping
3-34 Magellan® 1400i
Interface
Features
Keyboard Wedge — cont.
Wedge Quiet Interval
This feature does not apply to the USB Keyboard interface.
NOTE
Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the keyboard connection in order to transmit data to the host.
START / END
PROGRAMMING BAR CODES Selectable from 000 (no interval) to 255 in 10 msec increments. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the the Alphanumeric table in scanning the “START/END” bar code above.
Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again
Set Wedge Quiet Interval bar code followed by the three digits (zero padded) from
DEFAULT SETTING FOR THIS FEATURE:
010 (100 msec)
Set Wedge Quiet Interval
Product Reference Guide
3-35
Interface Related Features
Keyboard Wedge — cont.
Intercharacter Delay
This feature does not apply to the USB Keyboard interface.
NOTE
START / END
PROGRAMMING BAR CODES One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable from 000 to 255 in 10msec increments. To configure this feature, scan the “START/END” bar code above to place the unit in Pro­gramming Mode, then the “Set Intercharacter Delay,” followed by the three digits (zero padded) from the Alphanumeric table in
Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again scanning the “START/END”
bar code above/
DEFAULT SETTING FOR THIS FEATURE:
000 (No Delay)
Set Intercharacter Delay
3-36 Magellan® 1400i

Data Editing Overview

It is not recommended to use these features with IBM or Wand Emulation interfaces.
CAUTION
When a bar code is scanned, additional information can be sent to the host computer along with the bar code data. This combination of bar code data and supplementary user-defined data is called a “message string.” The features in this chapter can be used to build specific user-defined data into a message string.
There are several types of selectable data characters that can be sent before and after scanned data. You can specify if they should be sent with all symbologies, or only with specific symbolo-
Figure 4-1 shows the available elements you can add to a message string:
gies.
Chapter 4

Data Editing

Figure 4-1. Breakdown of a Message String
Label ID Transmission:
Enable this option to
transmit the Label ID you
configure for the scanned
Prefix SuffixAIM IDLabel ID Label IDBar Code Data

Please Keep In Mind...

Modifying a message string is not a mandatory requirement. Data editing is sophisticated feature allowing highly customizable output for advanced users. Factory default settings for data editing is typically set to NONE.
A prefix or suffix may be applied (reference the across all symbologies (set via the Global features in this chapter).
symbology.
OR...
AIM ID: This function is used to identify and display the common label identifier for its symbology. When enabled, this ID code will be transmitted before the scanned bar code data.
00 - 20 Characters (ASCII)
Symbologies chapter for these settings)
You can add any character from the ASCII Chart (from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID.
Product Reference Guide
4-1
Data Editing
Enter prefixes and suffixes in the order in which you want them to appear on the output.

Global Prefix/Suffix

Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data) as indicated in
Figure 4-2. Prefix and Suffix Positions
Prefix SuffixAIM IDLabel ID Label IDBar Code Data
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
Figure 4-2.
OR...
00 - 20 Characters (ASCII)
AND
OR
1. Determine which ASCII character(s) are to be added to scanned bar code data. In this example, we’ll add a dollar sign (‘$’) as a prefix.
2. Scan the START bar code.
3. Scan the SET PREFIX bar code.
4. Reference the
ASCII Chart on the inside back cover of this manual, to find the hex value
assigned to the desired character. The corresponding hex number for the ‘$’ character is
24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from
Numeric Pad.
Appendix C, Alpha-
5. Scan the END bar code to exit Programming Mode.
If less than the expected string of 20 characters are selected, scan the END bar code twice to accept the selections and exit Programming Mode.
NOTE
6. The resulting message string would appear as follows:
Scanned bar code data:12345 Resulting message string output: $12345
4-2 Magellan® 1400i
Global Pre-
fix/Suffix
Global Prefix/Suffix — cont.
START / END
PROGRAMMING BARCODES Sets up to 20 characters each from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the digits from the Alphanumeric table in
"Example: Setting a Prefix", for more information. Exit programming mode by scanning the “START/END” barcode again (scan
“START/END” twice if less than 20 characters have been selected).
Appendix C, Alpha-Numeric Pad representing your desired character(s). Reference the section,
DEFAULT SETTING PREFIX: 00 (None)
DEFAULT SETTING SUFFIX: 0D (CR)
Set Prefix
Set Suffix
Product Reference Guide
4-3
Data Editing

AIM ID

AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally standardized list — as opposed to custom label ID characters you select yourself — and can be included with scanned bar code data. AIM label identifiers consist of three characters as follows:
A close brace character (ASCII ‘]’), followed by...
A code character (see the table below), followed by...
A modifier character (the modifier character is symbol dependent)
SYMBOLOGY CHAR SYMBOLOGY CHAR
UPC/EAN E Code 128/EAN 128 C
Code 39 A MSI/Plessey M
Codabar F
Interleaved 2 of 5 I Standard 2 of 5 S
Code 93
a. ISBN (X with a 0 modifier character)
Figure 4-3. AIM ID
Prefix SuffixLabel ID Label IDBar Code DataAIM ID
START / END
GISBN
RSS (RSS-14, RSS Expanded)
e
a
X
PROGRAMMING BARCODES
Disable AIM ID
DEFAULT
Enable AIM ID
4-4 Magellan® 1400i

Label ID

Label ID
A Label ID is a customizable code of up to two ASCII characters (00-FF hex), used to identify a bar code (symbology) type. See
Appendix D, Default Settings, for a listing for common symbolo-
gies. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard label identifier for ALL symbology types, see the previous feature,
AIM ID.
To configure a Label ID:
1. Scan the START bar code.
2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate bar code.
3. Scan a bar code to select the symbology for which you wish to configure a custom Label ID.
4. Determine the desired character(s) (you may choose either one or two) which will repre­sent the Label ID for the selected symbology. Next, turn to the
ASCII Chart on the inside
back cover of this manual and find the equivalent hex digits associated with your choice of Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indi­cates its associated hex characters as 3D.
5. Turn to
Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex charac-
ters determined in the previous step. For the example given, the characters ‘3’ and ‘D’ would be scanned.
6. Scan the END bar code to exit programming mode.
Figure 4-4. Label ID Position Options
Prefix SuffixLabel ID Label IDBar Code DataAim ID
OR
Product Reference Guide
4-5
Data Editing
Label ID — cont.
START / END
Label ID Position: Before Bar Code Data
DEFAULT
PROGRAMMING BARCODES
Label ID Transmission: Disable
Label ID Position: After Bar Code Data
Set UPC-A Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-E Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/C128 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
4-6 Magellan® 1400i
Label ID — cont.
START / END
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Label ID
PROGRAMMING BARCODES
Set UPC-E w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/C128 Addon Label ID Character(s)
Set EAN-8 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-13 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/C128 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Product Reference Guide
4-7
Data Editing
Label ID — cont.
START / END
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
PROGRAMMING BARCODES
Set EAN-13 w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/C128 Addon Label ID Character(s)
Set ISBN Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: IA (4941 hex)
Set GTIN Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: G2 (4732 hex)
Set GTIN w/P5 addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: I (49 hex)
Set IATA Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: G (47 hex)
Set GTIN w/P2 addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: G5 (4735 hex)
4-8 Magellan® 1400i
Label ID — cont.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: G8 (4738 hex)
Set RSS-14 Label ID Character(s)
Label ID
Set GTIN w/C128 addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: R4 (5234 hex)
Set RSS Expanded Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: RX (5258 hex)
Set RSS Limited Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: * (2A hex)
Set Pharmacode 39 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: # (23 hex)
DEFAULT SETTING FOR THIS FEATURE: RL (524C hex)
Set Code 39 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set Code 128 Label ID Character(s)
Set I 2 of 5 Label ID Character(s)
Product Reference Guide
DEFAULT SETTING FOR THIS FEATURE: i (69 hex)
4-9
Data Editing
Label ID — cont.
START / END
DEFAULT SETTING FOR THIS FEATURE: % (25 hex)
Set Code 93 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
PROGRAMMING BARCODES
Set Codabar Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: & (26 hex)
Set Code 11 Label ID Character(s)
Set MSI/Plessey Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: s (73 hex)
Set PDF417 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: mP (6D50 hex)
DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
Set Std 2 of 5 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: P (5000 hex)
Set Micro PDF417 Label ID Character(s)
4-10 Magellan® 1400i
version

Case Conversion

This feature can convert scanned bar code data to either all lower case (a through z) or all upper case (A through Z) characters.
NOTE
START / END
Case Con-
Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.
PROGRAMMING BARCODES
Disable
DEFAULT
Convert to Upper Case
Convert to Lower Case
Product Reference Guide
4-11
Data Editing

Character Conversion

Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the charac­ter to convert in a pair is FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following:
41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs are FFFF and FFFF.
With the label, AG15TA81, it would look as follows after the character conversion: BG25TB82.
The A characters were converted to the B character and the 1 characters were converted to the numeral 2 character. Nothing is done with the last two character pairs, since they are all FF.
To set Character Conversion:
1. Scan the START/END bar code.
2. Scan the Character Conversion bar code.
3. Determine the desired string. Up to sixteen positions can be determined as in the above example. Next, turn to the the equivalent hex digits needed to fulfill the string.
4. Turn to Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex charac­ters determined in the previous step.
5. Scan the START/END bar code to exit Programming Mode.
If less than the expected string of 16 characters are selected, scan the START/END bar code twice to accept the selections and exit Programming Mode.
NOTE
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE:
FFFFFFFFFFFFFFFF hex (no conversion)
ASCII Chart on the inside back cover of this manual and find
Character Conversion
4-12 Magellan® 1400i
Chapter 5

Symbologies

The scanner supports the following symbologies (bar code types). Options for each symbology are included in this chapter.
·UPC-A ·Pharmacode 39
·UPC-E ·Transmit Function Characters
·EAN-13 ·Interleaved 2 of 5
·EAN-8 ·Codabar
·RSS-14 ·Code 93
·RSS Expanded ·MSI/Plessey
·RSS Limited ·Standard 2 of 5
·Code 39 ·
2D Symbologies
·PDF417 ·Micro PDF417
Factory Defaults—
this section. Reference

UPC-A

Disable/Enable UPC-A

When disabled, the scanner will not read UPC-A bar codes.
START / END
Enable UPC-A
DEFAULT
for the standard RS-232 interface are indicated in bold text throughout
Appendix D, Default Settings for default exceptions for your interface.
PROGRAMMING BAR CODES
Disable UPC-A
Product Reference Guide
5-1
Symbologies
UPC-A — continued

Check Digit Transmission

Enable this option to transmit the check digit along with UPC-A bar code data.
START / END
PROGRAMMING BAR CODES
Send Check Digit
DEFAULT
Don’t Send Check Digit

Expand UPC-A to EAN-13

Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the sym­bology ID to match those required for EAN-13.
START / END
PROGRAMMING BAR CODES
Expand to EAN-13
Don’t Expand to EAN-13
DEFAULT
5-2 Magellan® 1400i
UPC-A — continued

Number System Transmission

This feature enables/disables transmission of UPC-A System Number.
START / END
PROGRAMMING BAR CODES
Enable Number System Transmission
DEFAULT
UPC-A
Disable Number System Transmission

UPC-A Minimum Reads

This feature specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as a good read.
START / END
Minimum = 2 Reads
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-3
Symbologies
UPC-A — continued

UPC-A In-store Minimum Reads

This feature specifies the minimum number of consecutive times an in-store printed label must be decoded before it is accepted as a good read.
START / END
PROGRAMMING BAR CODES
Minimum = 2 Reads
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
5-4 Magellan® 1400i

UPC-E

The following options apply to the UPC-E symbology.

Disable/Enable UPC-E

When disabled, the scanner will not read UPC-E bar codes.
START / END
Enable UPC-E
DEFAULT
UPC-E
PROGRAMMING BAR CODES
Disable UPC-E

Check Digit Transmission

Enable this option to transmit the check digit along with UPC-E bar code data.
START / END
PROGRAMMING BAR CODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
Product Reference Guide
5-5
Symbologies
UPC-E — continued

Number System Digit

The Number System Digit (NSD) which is always a zero (0) in the leading position can be optionally included (or not) with scanned bar code data.
START / END
Include Number System Digit
PROGRAMMING BAR CODES
Exclude Number System Digit
DEFAULT

Expand UPC-E to UPC-A

Enables/disables expansion of UPC-E labels to UPC-A. Selecting this feature also changes the symbology ID to match those required for UPC-A.
START / END
Expand UPC-E to UPC-A
PROGRAMMING BAR CODES
Don’t Expand UPC-E to UPC-A
DEFAULT
5-6 Magellan® 1400i
UPC-E — continued

Expand UPC-E to EAN13

Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the symbology ID to match those required for EAN-13.
START / END
Expand UPC-E to EAN-13
UPC-E
PROGRAMMING BAR CODES
Don’t Expand UPC-E to EAN-13
DEFAULT

Minimum Reads

This feature specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as a good read.
START / END
Minimum = 2 Reads
DEFAULT
PROGRAMMING BAR CODES
Minimum = 1 Read
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-7
Symbologies

GTIN

The following options apply to the GTIN label data format.

Expand UPC/EAN to GTIN

When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN format.
START / END
PROGRAMMING BAR CODES
Expand to GTIN
Don’t Expand to GTIN
DEFAULT
5-8 Magellan® 1400i

EAN-13

The following options apply to the EAN-13 symbology.

Disable/Enable EAN-13

When disabled, the scanner will not read EAN-13 bar codes.
START / END
Enable EAN-13
DEFAULT
EAN-13
PROGRAMMING BAR CODES
Disable EAN-13

Check Digit Transmission

Enable this option to transmit the check digit along with EAN-13 bar code data.
START / END
PROGRAMMING BAR CODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
Product Reference Guide
5-9
Symbologies
EAN-13 — continued

EAN-13 Flag 1 Character

Enables/disables transmission of an EAN/JAN13 Flag1 character.
START / END
Transmit EAN-13 Flag 1 Char
DEFAULT
PROGRAMMING BAR CODES
Don’t Transmit EAN-13 Flag 1 Char

ISBN

When enabled, this feature truncates the leading three digits from labels that contain ISBN (International Standard Book Number) and appends an ISBN check character to the end of the label. These codes are used for books and magazines. Labels with ISBN codes start with "978".
Example:
Bar code data: “9789572222720”
Output: “9572222724”
START / END
PROGRAMMING BAR CODES
Disable ISBN
DEFAULT
Enable ISBN
5-10 Magellan® 1400i
EAN-13 — continued

Minimum Reads

This feature specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as a good read.
START / END
Minimum = 2 Reads
EAN-13
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
Product Reference Guide
5-11
Symbologies

EAN-8

The following options apply to the EAN-8 symbology.

Disable/Enable EAN-8

When disabled, the scanner will not read EAN-8 bar codes.
START / END
Enable EAN-8
DEFAULT
PROGRAMMING BAR CODES
Disable EAN-8

Check Digit Transmission

Enable this option to transmit the check Digit along with EAN-8 bar code data.
START / END
PROGRAMMING BAR CODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
5-12 Magellan® 1400i
EAN-8 — continued
EAN-8
Expand EAN-8 to EAN-13—
this feature also changes the symbology ID to match those required for EAN-13.
START / END
Expand to EAN-13

Minimum Reads

This feature specifies the minimum number of consecutive times an EAN-8 label must be decoded before it is accepted as a good read.
Expands EAN-8 data to the EAN-13 data format. Selecting
PROGRAMMING BAR CODES
Don’t Expand to EAN-13
DEFAULT
START / END
Minimum = 2 Reads
Minimum = 4 Reads
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 3 Reads
Product Reference Guide
5-13
Symbologies

Enable EAN Two-Label

Enables/disables the ability of the scanner to decode EAN two-label pairs.
START / END
PROGRAMMING BAR CODES
Enable EAN Two-Label

Enable EAN Two-Label Combined

Enables/disables the transmitting of an EAN two label pair as one label.
Disable EAN Two-Label
START / END
Enable EAN Two-Label Combined
NOTE
PROGRAMMING BAR CODES
Disable EAN Two-Label Combined
Contact Customer Support for
advanced programming of
Two-Label Pairs.
5-14 Magellan® 1400i

Add-ons

Add-ons
Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are:
None—
still read the main portion of the bar code.
2 Digits—
5 Digits—
Code 128 Add-on—
label.
This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but
The scanner will optionally read 2-digit add-ons with the UPC/EAN label.
The scanner will optionally read 5-digit add-ons with the UPC/EAN label.
The scanner will optionally read Code 128 add-ons with the UPC/EAN
Contact Customer Support for
advanced programming of optional
NOTE
and conditional add-ons.
Product Reference Guide
5-15
Symbologies
Add-ons — continued
START / END
Enable Optional 2-Digit Add-ons
PROGRAMMING BAR CODES
Disable Optional 2-Digit Add-ons
DEFAULT
Disable Optional 5-Digit Add-ons
DEFAULT
Enable Optional 5-Digit Add-ons
Enable Optional Code 128 Add-ons
Disable Optional Code 128 Add-ons
DEFAULT
5-16 Magellan® 1400i

RSS-14

The following options apply to the RSS-14 symbology.

Disable/Enable RSS-14

When this feature is disabled, the scanner will not read RSS-14 bar codes.
START / END
Enable RSS-14
RSS-14
PROGRAMMING BAR CODES
Disable RSS-14
DEFAULT

RSS-14 UCC/EAN 128 Emulation

When enabled, RSS-14 bar codes will be translated to the UCC/EAN 128 label data format.
START / END
PROGRAMMING BAR CODES
Enable RSS-14 UCC/EAN 128 Emulation
Disable RSS-14 UCC/EAN 128 Emulation
DEFAULT
Product Reference Guide
5-17
Symbologies
RSS-14 — continued

Minimum Reads

This feature specifies the minimum number of consecutive times an RSS-14 label must be decoded before it is accepted as a good read.
START / END
Minimum = 2 Reads
PROGRAMMING BAR CODES
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
5-18 Magellan® 1400i
RSS-14 — continued

RSS-14 2D Component

This setting enables/disables RSS-14/Micro PDF417 composite labels.
NOTE
START / END
RSS-14 and Micro PDF417 must be enabled to read
Both these composite labels.
PROGRAMMING BAR CODES
Disable RSS-14 2D Component
DEFAULT
RSS-14
Enable always on
RSS-14 2D Component
Product Reference Guide
5-19
Symbologies

RSS Expanded

The following options apply to the RSS Expanded symbology.

Disable/Enable RSS Expanded

When this feature is disabled, the scanner will not read RSS Expanded bar codes.
START / END
PROGRAMMING BAR CODES
Enable RSS Expanded
Disable RSS Expanded
DEFAULT

RSS Expanded UCC/EAN 128 Emulation

When enabled, RSS Expanded bar codes will be translated to the UCC/EAN 128 label data for­mat.
START / END
PROGRAMMING BAR CODES
Disable RSS Expanded UCC/EAN 128 Emulation
Enable RSS Expanded UCC/EAN 128 Emulation
DEFAULT
5-20 Magellan® 1400i
RSS Expanded — continued

Length Control

RSS Expanded
Fixed Length Decoding—
When fixed length decoding is enabled, the scanner will decode a
bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding—
When variable length decoding is enabled, the scanner will decode a bar code if the label length falls in the range of the configurable minimum and maxi­mum length.
Configuring Fixed Length Decoding:
1. Scan the START/END bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first fixed length by following the
Programming Instructions
below.
RSS Expanded Length 1, Length 2
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by following the RSS Expanded Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1. Scan the START/END bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first variable length by following the
Programming Instructions
below.
5. Set Length 2 to the second variable length by following the
Length 2 Programming Instructions below.
START / END
PROGRAMMING BAR CODES
Variable Length Decoding
Fixed Length Decoding
RSS Expanded Length 1, Length 2
RSS Expanded Length 1,
DEFAULT
Product Reference Guide
5-21
Symbologies
RSS Expanded — continued

RSS Expanded Length 1, Length 2 Programming Instructions

1. Scan the START/END bar code.
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent-
ing the length in decimal notation.
For RSS Expanded bar codes, only the data characters are included in the length calcula­tions.
NOTE
4. Scan the START/END bar code.
START / END
PROGRAMMING BAR CODES
DEFAULT SETTING FOR THIS FEATURE: 008
Set Length 2
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 014
5-22 Magellan® 1400i
RSS Expanded — continued

Minimum Reads

This feature specifies the minimum number of consecutive times an RSS Expanded label must be decoded before it is accepted as a good read.
START / END
PROGRAMMING BAR CODES
Minimum = 2 Reads
RSS Expanded
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
Product Reference Guide
5-23
Symbologies
RSS Expanded — continued

RSS Expanded 2D Component

This setting enables/disables RSS Expanded/Micro PDF417 composite labels.
RSS Expanded and Micro PDF417 must be enabled
Both to read these composite labels.
NOTE
START / END
PROGRAMMING BAR CODES
Disable RSS Expanded 2D Component
DEFAULT
Enable always on
RSS Expanded 2D Component

RSS Limited

The following options apply to the RSS Limited symbology.

Disable/Enable RSS Limited

When this feature is disabled, the scanner will not read RSS Limited bar codes.
START / END
PROGRAMMING BAR CODES
Disable RSS Limited
DEFAULT
Enable RSS Limited
5-24 Magellan® 1400i
Loading...