To prevent from fire or shock hazard,do not expose monitor to any rain or any form of water.High
voltage is inside the monitor so please do not remove the back cover of the cabinet if you are not a qualified
monitor engineer.
Contact the local dealer or the nearest
PROVIEW
A. IMPORTANT SAFETY INSTRUCTION
Prior to using this service manual,please ensure that you have carefully followed all the procedures outlined in the
user's manual for this product.
Read all of these instructions.
1.
Save these instructions.
2.
Follow all warnings and instructions a marked on the product.
3.
Unplug this product from the wall outlet before cleaning.Do not use liquid cleaners or aerosol
4.
cleaners, use a damp cloth for cleaning.
Do not use this product near water.
5.
Do not place this product on an unstable cart,stand or tablle.The product may fall,causing serious
6.
damage to the product.
Slots and openings in the cabinet and the back or bottom are provided for ventilation,to ensure
7.
reliable operation of the product and to protect it from overheating,those openings must not be
blocked or covered.The openings should never be blocked by placing the product on a bed,sofa, rug,
or other similar surface.This product should not be placed in a built -in installation less proper
ventilation is provided.
This products should be operated from the type of power source indicated on the marketin label.
8.
If you are not sure of the type of power available, consult your dealer or local power company
This product is equipped with a 3-wire grounding type plug,a plug having a third (grounding)
9.
pin.This plug will only fit into a grounding-type power outlet.This is a safety feature,if you are
unable to insert the plug into the outlet,contact your electrician to replace your obsolete outlet.Do
not defeat the purpose of the grounding-type plug.
Do not allow anything to rest on the power cord.Do not locate this product where persons will walk
10.
on the cord.
If an extension cord is used with this product,make sure that the total of the ampere ratings on the
11.
product plugged into the extension cord to the waplugged into outlet does not exceed 15 ampere.
Never push objects of any kind into this product through cabinet slots as they may touch dangerous
12.
voltage points or short out parts that could result in a risk of fire or electric shock.Never spill liquid
of any kind on the product.
Do not attempt to service this product yourself,as opening or removing covers may expose you to
13.
dangerous voltage points or other risks.Refer all servicing to service personnel.
Unplug this product from the wall outlet and refer servicing to qualified service personnel under the
14.
following conditions.
When the power cord or plug is damaged or frayed.
a.
If liquid has been spilled into the product.
b.
If the product has been exposed to rain or water.
c.
If the product does not operate normally,when the operating instructions are followed.Adjust
d.
only those controls that are covered by the operating instructions since improper adjustment of
other controls may result in damage and will often require extension work by a qualified
technician to restore the product to norma l operation.
If the product has been dropped or the cabinet has been damaged.
e.
f. If the product exhibits a distinct change in performance,indicating a need for service.
branch office if you need help.
1
B. SPECIFICATIONS
796N
Screen
1.
Visible Image Area15.7 inch
2.
Active Display Area310mm (H) × 230mm (V)
3.
Synchronization Range
4.
Horizontal
Vertical
Power Source100 – 240 Vac , 60/50 Hz
5.
Power Consumption (max.)110W
6.
Input Signal
7.
Video
Sync.
Connection Type15 Pin D Type
8.
Resolution1600 × 1200 pixels
9.
Color Temperature9300º K / 6500º K / 5500º K
10.
Dimension (W×H×D)410 × 410 × 420 (mm) -----
11.
Monitor Weight
12.
Net :
Gross :
Base Operation
13.
Tilt
Swivel
Power Saving
14.
Normal operation :
Off mode
Signal Connector Pin Assignment
15.
Pin No.
1. Red video input
2. Green video input
3. Blue video input
4. Ground
5. DDC return
6. Red return
7. Green return
8. Blue return
9. Not connected
10.Ground
17”, 0.25mm flat Square tube, 90º deflection, Anti-glare,
Anti -static,Anti-relection.
30 – 98 KHz
50 – 160 Hz
Analog R.G.B. , 0.7Vp- p / 75 Ohm
TTL level,positive or negative polarity