To prevent from fire or shock hazard,do not expose monitor to any rain or any form of water.High
voltage is inside the monitor so please do not remove the back cover of the cabinet if you are not a qualified
monitor engineer.
Contact the local dealer or the nearest MAG branch office if you need help.
A. IMPORTANT SAFETY INSTRUCTION
Prior to using this service manual,please ensure that you have carefully followed all the procedures outlined in
the user's manual for this product.
1. Read all of these instructions.
2. Save these instructions.
3. Follow all warnings and instructions a marked on the product.
4. Unplug this product from the wall outlet before cleaning.Do not use liquid cleaners or aerosol
cleaners, use a damp cloth for cleaning.
5. Do not use this product near water.
6. Do not place this product on an unstable cart,stand or tablle.The product may fall,causing serious
damage to the product.
7. Slots and openings in the cabinet and the back or bottom are provided for ventilation,to ensure
reliable operation of the product and to protect it from overheating,those openings must not be
blocked or covered.The openings should never be blocked by placing the product on a bed,sofa, rug,
or other similar surface.This product should not be placed in a built-in installation less proper
ventilation is provided.
8. This products should be operated from the type of power source indicated on the marketin label.
If you are not sure of the type of power available, consult your dealer or local power company
9. This product is equipped with a 3-wire grounding type plug,a plug having a third (grounding)
pin.This plug will only fit into a grounding-type power outlet.This is a safety feature,if you are
unable to insert the plug into the outlet,contact your electrician to replace your obsolete outlet.Do
not defeat the purpose of the grounding-type plug.
10. Do not allow anything to rest on the power cord.Do not locate this product where persons will walk
on the cord.
11. If an extension cord is used with this product,make sure that the total of the ampere ratings on the
product plugged into the extension cord to the waplugged into outlet does not exceed 15 ampere.
12. Never push objects of any kind into this product through cabinet slots as they may touch dangerous
voltage points or short out parts that could result in a risk of fire or electric shock.Never spill liquid
of any kind on the product.
13. Do not attempt to service this product yourself,as opening or removing covers may expose you to
dangerous voltage points or other risks.Refer all servicing to service personnel.
14. Unplug this product from the wall outlet and refer servicing to qualified service personnel under the
following conditions.
a. When the power cord or plug is damaged or frayed.
b. If liquid has been spilled into the product.
c. If the product has been exposed to rain or water.
d. If the product does not operate normally,when the operating instructions are followed.Adjust
only those controls that are covered by the operating instructions since improper adjustment of
other controls may result in damage and will often require extension work by a qualified
technician to restore the product to normal operation.
e. If the product has been dropped or the cabinet has been damaged.
f.
If the product exhibits a distinct change in performance,indicating a need for service.
For Model 786PF
WARNING :
This product included critical components which are essential for X-Radiation safety.
3
Page 4
See service manual for proper replacement.Maximum 2nd anode voltage must not exceed
30KV at any operating conditions.
To measure 2nd voltage use high impedance meter connect (-) chassis, use a high voltage
lead from (+) to 2nd anode.
VR501,VR601 has been sealed against improper replacement or defeating the control.
Instructions for proper replacement of such sealed controls should also be provided in the
1. Make the adjustment to the value shown at right
by turning the VR501 on the main PCB.
15.5V
±0.2V
High Voltage
Adjust
B
Preset
Adjust
C
﹟Digital Voltmeter
﹟High Voltage
Probe
﹡Anode Cap-GND
﹫Crosshatch Pattern
(31.5KHz,640x480)
﹫Crosshatch
(31.5KHz,640x480)
1. Turn the power switch of the monitor OFF.
2. Connect high voltage probe to Anode Cap and
GND.
3. Turn the power switch of the monitor ON.
(15 minutes)
4. Make the adjustment to the value shown at right
by turning the VR601 on the main PCB.
1. Turn the power switch of the monitor OFF.
2. Hold encorder key,then turn the power switch of the monitor ON.
3. Turn encorder key,make sure into preset picture,
if not ,please return 1-2.
4. Please following the procedure of selection and
adjusting an item using the OSD system as below
steps for main function adjusent.
Step 1 : Press and relese the OSD control knob to
activate the OSD menu.
Step 2 : Turn the knob to highlight the desired option
of OSD icon.
Step 3 : Press and release the knob again to access
the option. The color of the inner area of the
OSD will changed from blue to green.
Step 4 : To make your adjustment,turn the knob
Clockwise to increase or countclockwise
to decrease the setting.
Step 5 : Press and release the knob again to store
the change.the color of the inner area will
go back to blue.You can select EXIT icon
and press the knob the exit the OSD menu.
26.0KV
Contrast :
MAX.
Brightness
MAX.
H-Size :
mm
310
V-Size :
230
mm
H-Posi. :
Center
V-Posi :
Center
ITEM
Program Menu.
﹟Test Meter
﹡Test Point
﹫Pattern
Operation
Adjusting
Value
9
Page 10
Background
White
Balance
D
Adjust
White
Balance
Adjust
E
ABL
F
Adjust
﹟Color Analyzer
﹫R.G.B off
(68KHz,1024x768)
﹟Color Analyzer
﹟Oscilloscope
﹡Cathode G
﹫3” block
(68KHz,1024x768)
﹟Color Analyzer
﹫Full White
(64KHz,1280x1024)
1. Set the contrast to MAX.,Brightness to Y=0.7
K
set color is 9300
using the OSD.
°
2. Set the OSD to COLOR of sub menu and press
knob.
3. Make the adjustment R.G.B BIAS low light to
the value shown at right by using encorder.
1. Move the OSD to the R.G.B. DRIVE.
2. Move the OSD to the G DRIVE and make the
adjustment to the value shown at right by using
encorder.
3. Move the OSD to the R,B-DRIVE and make the
Adjustment to the value shown at right by using
Encorder.
1. Set the contrast to MAX.,Brightness to MAX.
2. Make the adjustment to the value shown at right
by adjustment ABL on the OSD menu.
Y = 0.7
±0.1FL
x = 0.283
±0.01
y = 0.297
±0.01
P-P
37V
x = 0.283
±0.01
y = 0.297
±0.01
Y = 33FL
Other
Function
Seting
G
Dynamic
Focus
H
Adjust
Purity
Adjust
I
﹫Full White
(64KHz,1280x1024)
﹟Oscilloscope
﹡FBT Pin14
﹫Full White
(31.5KHz,640x480)
﹫Magenta color
(31.5KHz,640x480)
1. Set the FREQ. to 87
2. Set the OSD to MAG
3. Set the BURN to Disable
4. Set the TIME to 15
5. Set the DEFO to TDA9113/9112
1. Set the contrast to MAX.,and adjustment
Brightness to the raster just appear.
2. Make the adjustment to the value shown at right
by adjust the VF on the OSD menu.
3. Make the check to the value shown at right by
adjust the HF on the OSD menu.
1. Adjust the purity magnet is in magneta color.
2. Turning two overlapping pawels in opposite
directions.
3. Move them until they are at the same angle,
9 o’clock and 3 o’clock respectively.
VF :
140
±10V
HF :
430
±10V
P-P
P-P
ITEM
Program Menu.
﹟Test Meter
﹡Test Point
﹫Pattern
10
Operation
Adjusting
Value
Page 11
Static
Convergence
Adjust
J
﹫
Magenta color
(31.5KHz,640x480)
1. Open the two pawels of the 4 pole magnets to
allow the red and blue vertical lines to unite.
2. Open and rotate the two pawels at a contrast
angle so that the red and blue horizontal lines
can unite.
3. If the vertical lines deviates,open the two powals
at the deviation position and make a monitor
adjustment by changing its angle.
4. Display white crosshatch pattern.
5. Make the red and blue vertical lines at the
center unite with the green by opening the two
6 pole pawels.
6. Rotate the two pawels at contrast angle so that
the red and blue horizontal lines can unite with
the green.
7. If the vertical lines deviate,change the angle of
Pawels from the deviation position.