MATERIAL SAFETY DATA SHEET
Inhalation of solvents may cause irritation. Propellant is a simple
Asphyxiant.
May cause headache, nausea, vomiting and weakness
Effects of acute exposure
Dizziness, nausea, irritation to skin and eyes
Effects of chronic exposure
Solvents may cause Defatting Dermatitis
Exposure limit of material
>16,000 ppm (4hr)
INHAL - RAT
Diethylene
Glycol Ethyl
Ether
Emergency first aid
procedures
In the case of eye contact, flush immediately with plenty of water for
at least 15 minutes and get medical attention. For skin, wash
thoroughly with soap and water. If affected by inhalation of vapour or
spray mist, remove to fresh air. If swallowed; Do not induce
vomiting, get medical attention.
Auto Ignition Temperature (ºC)
1. IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY
3. COMPOSITION / INFORMATION ON CONSTITUENTS
Product name: PRO-LINK STANDARDAIRE 90-DAY METERED AIR FRESHENER
(All Fragrances)
Datasheet No. : PRO-010
Product Use : Metered Air Freshener
Supplier : Pro-Link Inc.
Address : Canton MA
Telephone : 1-800-74LINKS
EMERGENCY TELEPHONE NUMBER:
Call INFOTRAC : 1-800-535-5053 24-Hrs per Day; 7-Days per Week
1.2 Trading Name
Citrus Sparkle (SA01-90R), Summer Day (SA03-90R), Floral Spice (SA04-90R), Apple Grove
(SA05-90R), Cinnamon Stick (SA06-90R), Tropical Fruit (SA07-90R).
___________________________________________________________________________________
Date of last change 07/19/2011 Page 1 of 4
MATERIAL SAFETY DATA SHEET
Water from fogging nozzles may be used to cool closed
containers to prevent build up if exposed to extreme
temperatures. Full protective equipment including self
contained breathing apparatus should be worn in a fire
involving this material.
If yes, under which conditions?
Excessive heat, sparks and open flame
Water, Carbon Dioxide, Dry Chemical, Foam
Upper Flammable limit (% by volume)
Lower Flammable limit (% by volume)
Explosion Data – Sensitivity to static
discharge
Not Applicable
Explosion Data – Sensitivity to impact
Hazardous combustion – Products
Hygdrocarbon fumes and smoke. Carbon Monoxide where
combustion is incomplete.
Aerosol flame projection – classified as:
Aerosol flame projection – flashback:
Flash Point (ºC), Tag Closed-Cup
(Concentrate)
Lowest known value is acetone @ -18ºC
Remove all sources of ignition. Use an inert absorbent material, and
non-sparking tools. Ventilate area. Prevent from entering a
watercourse.
Keep away from heat, sparks, and open flames
Ventilation – Local (Mechanical if used indoors on a continuous basis)
Handling Procedures and
Equipment
Store in a cool, well ventilated area not to exceed 50 deg. C
Synergistic Materials
Not normally required
Other / Type
6. ACCIDENTAL RELEASE MEASURES
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
___________________________________________________________________________________
Date of last change 07/19/2011 Page 2 of 4