MATERIAL SAFETY DATA SHEET
1. IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY
Product name : PRO-LINK STANDARDAIRE 30-DAY METERED AIR FRESHENER
(All Fragrances)
Datasheet No. : PRO-001
Product Use : Metered Air Freshener
Supplier : Pro-Link Inc.
Address : Canton MA
Telephone : 1-800-74LINKS
EMERGENCY TELEPHONE NUMBER:
Call INFOTRAC : 1-800-535-5053 24-Hrs per Day; 7-Days per Week
1.2
Trading Name
Citrus Sparkle (SA01-30R), Powder Fresh (SA02-30R), Summer Day (SA03-30R), Floral Spice
(SA04-30R), Apple Grove (SA05-30R), Cinnamon Stick (SA06-30R), Tropical Fruit (SA07-30R),
Pomegranate (SA08-30R), Vanilla Blossom (SA09-30R).
Hazardous Ingredient(s) CAS No: % (W/W) Symbol R Phrases
2. HAZARD INFORMATION
Contact with Eyes: May cause irritation
Contact with Skin: May cause irritation
Inhalation: Inhalation of solvents may cause irritation. Propellant is a simple
Asphyxiant.
Ingestion: May cause headache, nausea, vomiting and weakness
Effects of acute exposure Dizziness, nausea, irritation to skin and eyes
Effects of chronic exposure Solvents may cause Defatting Dermatitis
Exposure limit of material See section 2
3. COMPOSITION / INFORMATION ON CONSTITUENTS
Chemical
Name
Acetone 30-60% 67-64-1 >9750 mg/kg
Propane 15-40% 74-98-6 N/A N/A 1000ppm
Diethylene
Glycol Ethyl
Ether
Fragrance 1-5% N/A N/A N/A N/A
4. FIRST AID MEASURES
Emergency first aid
procedures
Concentration CAS
Number
10-20% 111-90-0 6500mg/kg
In the case of eye contact, flush immediately with plenty of water for
at least 15 minutes and get medical attention. For skin, wash
thoroughly with soap and water. If affected by inha lation of vapour or
spray mist, remove to fresh air. If swallowed; Do not induce
LD/50, Route,
Species
ORAL - RAT
RAT - ORAL
LC/50 Route,
Species
>16,000 ppm (4hr)
INHAL - RAT
N/A N/A
Exposure
Limit
750ppm
___________________________________________________________________________________
Date of last change 22/03/10 Page 1 of 4
MATERIAL SAFETY DATA SHEET
vomiting, get medical attention.
5. FIRE FIGHTING METHODS
Auto Ignition Temperature (ºC) 204-465
Special Procedures Water from fogging nozzles may be used to cool closed
containers to prevent build up if exposed to extreme
temperatures. Full protective equipment including self
contained breathing apparatus should be wo r n in a fire
involving this material.
Flammability Flammable
If yes, under which conditions? Excessive heat, sparks and open flame
Extinguishing media Water, Carbon Dioxide, Dry Chemical, Foam
Upper Flammable limit (% by volume) 23.5
Lower Flammable limit (% by volume) 1.2
Explosion Data – Sensitivity to static
discharge
Explosion Data – Sensitivity to impact Not Applicable
Hazardous combustion – Products Hygdrocarbon fumes and smoke. Carbon Monoxide where
Aerosol flame projection – classified as: 15 – 45 cm
Aerosol flame projection – flashback: None
Flash Point (ºC), Tag Closed-Cup
(Concentrate)
6. ACCIDENTAL RELEASE MEASURES
Leak/spill Remove all sources of ignition. Use an inert absorbent material, and
non-sparking tools. Ventilate area. Prevent from entering a
watercourse.
7. HANDLING & STORAGE
Storage Needs Keep away from heat, sparks, and open flames
Engineering controls Ventilation – Local (Mechanical if used indoors on a continuous basis)
Handling Procedures and
Equipment
Synergistic Materials None known
8. EXPOSURE CONTROLS / PERSONAL PROTECTION
Gloves / Type Not normally required
Respiratory / Type Not normally required
Eye / Type Safety Glasses
Footwear / Type Not normally required
Other / Type Not required
Store in a cool, well ventilated area not to exceed 50 deg. C
Not Applicable
combustion is incomplete.
Lowest known value is acetone @ -18ºC
___________________________________________________________________________________
Date of last change 22/03/10 Page 2 of 4