Warning
To avoid electric shock or personal injury, read
"Safety Information" and is Warning and
Precautions" before using the Meter
Safety information
This series meter Comply with IEC 1010-1 CAT I
600V / CAT II 300V overvoltage standards. See
specifications
Use the Meter only as specified in this manual,
otherwise the protection provided by the Meter
may be impaired.
In this manual a Warming identifies conditions
and actions that pose hazards to the user.
A caution identifies conditions and actions that
may damage the meter ort he equipment under
test
International symbols used on the Meter and in
this manual are explained Table
2
Table 1. International Electrical Symbols
AC (Alternating Current)
DC (Direct Current)
AC or DC
Battery
Safety information* Refer to the manual
Earth ground
Fuse
Conforms to European Union directive
Double insulated
WARNING AND PRECAUTIONS
To avoid possible electric shock or personal injury,
and to avoid possible damage to the meter or to the
equipment under test, comply with the following
practices:
Do not use the meter if it is damaged. Before you
use the meter, inspect the case. Pay particular
attention to the insulation surrounding the
connectors.
Inspect the test leads for damaged insulation or
3
Do not use the meter if it operates abnormally.
Protection may be impaired. When in doubt, have
the meter serviced.
Do not operate the meter around explosive gas,
vapor, or dust.
Do not apply more than the rated voltage, as
marked on the meter between terminals or
between any terminal and earth ground.
Before use, verify the meter's operation by
measuring a known voltage.
When measuring current, turn off circuit power
before connecting the meter in the circuit.
When servicing the meter, use only specified
replacement parts. Do not use the Meter in a
manner not specified by this manual or the safety
features of the meter may be impaired.
Use with caution when working above 30V ac rms,
42V ac peak, or 60V dc. Such voltages pose a
shock hazard.
When using the probes, keep your fingers behind
the finger guards on the probes.
Connect the common test lead before you
connect the live test lead. When you disconnect
test leads, disconnect the live test lead first.
Remove the test leads from the meter before you
open the battery door. Do not operate the meter
4
with the battery door or portions of the cover
removed or loosened.
To avoid false readings, which could lead to
possible
Safety Compliance: IEC 61010-1, 2000 CAT I
600V overvoltage standards Do not measure
voltages above 500V in Category installations
Overvoltage installations categories per IEC
61010-1, 2000: The meter is designed to protect
against transients in these categories:
CAT I From high-voltage low-energy sources,
CAT II From equipment supplied from the fixed
CAT III From equipment in fixed equipment
General specifications
Maximum Voltage between any Terminal and
Measurement rata: updates 2-3/sec.
Over range indication: "1' figure only in the display
Automatic negative polarity indication.
The
operating temperature: 0℃~40℃, 0-75% RH.
e.g., electric circuits or a copy machine
installation, e.g., TVs, PCs, portable tools
and household appliances
installations, e.g. installation panels,
feeders and short branch circuits, and
lighting systems in large buildings.
Earth Ground: 1000V
is displayed when the battery voltage
drops below the operating voltage
5
Storage temperature: -10℃~50℃, 0-75% RH.
Power: Single standard 1.5V battery AAAx2
Dimensions: 130L*72W*28H mm
Weight approx: 130g (not including battery)
FRONT PANEL DESCRIPTION
1. LCD Display
2. DATA HOLD button
3. BACK LIGHT button
4. FUNCTION AND RANGE SWITCH
This switch is used to select the function and
desired range as well as to turn on the instrument.
To extend the life of this battery, the switch should
be in the "OFF" position when the instrument is
not in use.
5. “VΩmA" JACK
6. "10A" JACK
7. "COM" JACK
SPECIFICATIONS
Accuracies are guaranteed
less than 80%RH
for 1 year, 23℃±5 ℃,
6
DC VOLTAGE
Range Resolution Accuracy
200mV 100uV
2000mV 1mV
20V 10mV
200V 100mV
500V 1V ±(1.0%+3d)
OVERLOAD PROTECTION: 220V rms AC for
200mV range and 500V DC or 500V rms for all
ranges.
AC VOLTAGE
Range Resolution Accuracy
200V 100mV
500V 1V
RESPONSE: Average responding, calibrated in rms
of a sine wave.
FREQUENCY RANGE: 40Hz ~400Hz
OVERLOAD PROTECTION: 500V DC or 500V rms
for all ranges.
±0.8%+3d
±1.2%+5d
7
DC CURRENT
Range ResolutionAccuracy
2000uA 1 uA
20mA 10 uA
±(1.2%+5d)
200mA 100 uA
10A 10mA ±(2.5%+5d)
OVERLOAD PROTECTION: 200mA 250V fuse (10A
range unused).
MEASURING VOLTAGE DROP: 200mV
AUDIBLE CONTINUITY
RANGE DESCRIPTION
Built-in buzzer sounds if resistance
is less then 30±20Ω
OVERLOAD PROTECTION: 5 second maximum
220V rms.