Prokit's Industries 3PK-9912 User Manual

Page 1

OPERATOR’S

INSTRUCTION MANUAL

AC / DC CLAMP METER
Page 2

CONTENTS PAGE

SAFETY INFORMATION ….……………………………………………. SAFETY SYMBOLS .………………………………………………….. SAFETY PRECAUTIONS ……………………………………………..

MAINTENANCE .…………………………………………………….....

GENERAL DESCRIPTION …..……………………………………….. FRONT PANEL DESCRIPTION …..…………………………………. OPERATING INSTRUCTIONS ………………………………………. SPECIFICATIONS …...………………………………………………... REPLACING THE BATTERY ...……………………………………….. ACCESSORIES ………………………………………………………...
1 1 1 1 3 3 6 8 10 11
Page 3

SAFETY INFORMATION

The AC/DC clamp meter has been designed according to IEC1010 – 1 and IEC1010 – 2 – 032 concerning safety requirements for electrical measuring instruments and hand – held current clamps with an overvoltage category (CAT II) and pollution 2.

SAFETY SYMBOLS

Important safety information, refer to the operating manual.
Dangerous voltage may be present.
Earth ground.
Double insulation (Protection class II).
The AC/DC clamp meter complies with the requirements of the following European Community Directives: 89/336/EEC (Electromagnetic Compatibility) and 73/23/EEC (Low Voltage) as amended by 93/68/EEC (CE Marking). However, electrical noise or intense electromagnetic fields in the vicinity of the equipment may disturb the measurement circuit. Measuring instruments will also respond to unwanted signals that may be present within the measurement circuit. Users should exercise care and take appropriate precautions to avoid misleading.

SAFETY PRECAUTIONS

Follow all safety and operating instructions to ensure maximum personal safety during the operation and to ensure the meter is used safely and is kept in good operating condition.
Page 4
-1-
Read these operating instructions thoroughly and completely before
operating your meter. Pay particular attention to WARNINGS, which will inform you of potentially dangerous procedures. The instructions in these warnings must be followed. Always inspect your meter and test leads for any sign of damage or
abnormality before every use. If any abnormal conditions exist (i.e. broken test leads, cracked cases, display not reading, etc.), do not attempt to take any measurements. Do not expose the instrument to direct sunlight, extreme temperature or
moisture. Never ground yourself when taking electrical measurements. Do not
touch exposed metal pipes, outlets, fixtures, etc., which might be at ground potential. Keep your body isolated from ground by using dry clothing; rubber shoes, rubber mat, or any approved insulating material. You always are careful when working with voltages above 60V dc or
30V ac rms. Keep fingers behind the probe barriers while measuring. Never use the meter to measure voltages that might exceed the
maximum allowable input value of an y function. Never touch exposed wiring, connections or any live circuit when
attempting to take measurements.
MAINTENANCE
Before opening the case, always disconnect test leads from all
energized circuits. Never use the meter unless the back cover is in place and fastened
completely. Do not use abrasives or solvents on the meter. To clean it using a damp
cloth and mild detergent only. Qualified and trained service technicians should only perform calibration
and repair of the meter.
Page 5
-2-
Do not attempt calibration or service unless trained and another
person capable of rendering first ai d and resuscitation is present.

GENERAL DESCRIPTION

The meter is an autoranging professional AC/DC clamp meter with digital and analog display, 3200 counts and 33-segment bar graph. For measuring DC and AC voltage, DC and AC current, Resistance, Frequency, Diode and Continuity Test with battery operated.

FRONT PANEL DESCRIPTION

Transformer jaws

1.
Pick up the AC current or DC current flowing through the conductor.

Hold button

2.
When this button is pushed, the display will keep the last reading and “ ” symbol will appear on the LCD until pushing it again.

Rotary switch

3.
This switch is used to select functions and desired ranges as well as to turn on/off the meter.

R-H button

4.
In autorange, press this button to select manual range and the “R-H” symbol will appear on the LCD. In manual range, press this button momentarily to step up 1 range at one time, press this button for more than 1 second to select autorange. The function is only for AC/DC voltage and resistance range.

LIGHT button

5.
To use this function, press this LIGHT button. When the button is pushed, the light of display is on. After about 3 5 seconds, the light is self-off. The light is on again, just push this button once.

Display

6.
3200 counts and 33 segments ba r gra ph , di git is 15mm high.
Page 6
7.
8.
9.
10.
11.
12
-3-

“VHz” jack

This is positive input terminal for volt and frequency measurement connection is made to it using the red test lead.

“COM” jack

This is negative (ground) input terminal for all measurement modes except current. Connection is made to it using the black test lead.
Ω” jack
This is the positive input ter minal for ohms. Connectio n is made to it using the red test lead.
FUNC. button
The button is used to select or testing in / range and to select ACA or DCA in AC current ranges.

Trigger

Press the lever to open the transformer. When the lever is released, the jaws will close again.

DCA ZERO

.
Adjusting the DCA ZERO knob, when the display is not zero reading for does not measurement before.
Page 7

AC/DC CLAMP METER LAYOUT

-4-
  
Page 8
-5-
OPERATING INSTRUCTIONS DC VOLTAGE MEASUREMENT
1.
Connect the red test lead to the “VHz” jack and the black lead to the “COM” jack.
2.
Set rotary switch at desired V position.
3.
Connect test leads across the source or load being measured.
4.
Read voltage value on the LCD display along with the polarity of the red lead connection.

AC VOLTAGE MEASUREMENT

1.
Connect the red test lead to “VHz” jack and the black test lead to the “COM” jack.
2.
Set the rotary switch at desired V~ position.
3.
Connect test leads across the source or load being measured.
4.
Read voltage value on the LCD display.

AC CURRENT MEASUREMENT

1.
Set the rotary switch at desired 300A or 1000A position. Push Func. button to 300A~ or 1000A~ range.
2.
Press the trigger to open transformer jaw and to clamp one conductor only, making sure that the jaw is firmly closed around the conductor.
3.
Read current value on LCD display.

DC CURRENT MEASUREMENT

1.
Set the rotary switch at desire d 300A or 1000A position.
2.
Adjusting the DCA ZERO knob until the display show “0”, when the meter does not measurement before.
3.
Press the trigger to open transformer jaw and to clamp one conductor only, making sure that the jaw is firmly closed around the conductor.
4.
Read current value on LCD display.
NOTE:
Page 9
As the jaw core may remain some magnetic force after using for awhile. If the display can not reach “0”, taking following process to correct it please:
1. Open the jaws several times.
-6-
2. Adjusting the DCA ZERO knob, making the display is “0”.
3. Then work again.
RESISTANCE MEASUREMENT
1.
Connect the red test lead to “Ω” jack and black test lead to the “COM” jack (The polarity of red lead is positive “+”).
2.
Set the rotary switch at desired ”Ω” range position.
3.
Connect test leads across the resistor to be measured and read LCD display.
4.
If the resistance being measured is connected to a circuit,turn off power and discharge all capacitors before applying test leads.
NOTE:
1.
If the resistance being measured exceeds the maximum value of the range selected or the input is not connected, an overrange indication OLwill be displayed.
2.
When checking in-circuit resistance, be sure the circuit under test has all power removed and that all capacitors have been discharged fully.
3.
For measuring resistance above 1MΩ, the meter may take a few seconds to get stable reading. This is normal for high resistance
4.
measurements. When the input is not connected, i.e. at open circuit, the figure “OL” will be displayed for the overrange condition.

MEASURING FREQUENCY

1.
Connect the red test lead to “VHz” jack and the black test lead to the “COM” jack.
2.
Set the rotary switch at desired kHz position .
3.
Connect test leads across the source or load being measured.
4.
Read frequency value on the LCD display.
NOTE:
Page 10
The input voltage should be between 200mV and 10V rms. ac. If the voltage is more than 10V rms. reading may be out of the accuracy range.
-7-

AUDIBLE CONTINUITY AND DIODE TEST

1.
Connect red test lead to “Ω” jack, black test lead to “COM” jack. The polarity of red lead connection is positive “+”.
2.
Set range switch to “ / ” position and push the FUNC. button to select audible continuit y or diode test mode.
3.
If audible continuity is selected, connect test leads to two points of circuit to be tested. If continuity exists, built-in buz ze r w ill so un d.
4.
If diode test mode is selected, connect the red and black leads to the anode and cathode of the diode under test. The forward voltage drop of this diode in V will be displayed.

SPECIFICATIONS

Accuracy is specified for a period of one year after calibration and at 18℃ to 28 (64°F to 82°F) with relative humidity to 80%.

GENERAL

Maximum voltage between terminals and earth ground Display : LCD, 3200 counts and 33 segments bar graph
Ranging method : Auto / Manual Polarity indication : “-” displayed for negative polarity Overrange indication : Only figure “OL” on the display Jaw opening capability : 55mm (Max conductor size) Power : 9V battery, NEDA 1604 or 6F22 006P Low battery indication : “ ” appears on the display Operating environment : 0 to 40 Storage temperature : -10 to 50 Temperature coefficient : 0.1×specified accuracy) / ( <18 or >28℃ ) Altitude : 2000m Size : 282mm×104mm×47mm Weight : Approx. 550g.
: CAT II 1000V dc or 750V ac rms. (sine)
updates 2-3/sec.
Page 11
-8-
DC VOLTAGE
Range Resolution Accuracy
3V 1mV
30V 10mV
300V 0.1V
1000V 1V ±1.0% of rdg ± 2 digits
Input Impedance: 10MΩ

AC VOLTAGE

Range Resolution Accuracy
3V 1mV
30V 10mV 300V 0.1V 750V 1V ±1.2 % of rdg ± 5 digits
Input Impedance: 10MΩ Frequency range: 40Hz to 200Hz. Response: Average responding, calibrated in rms. of a sine wave.

AC CURRENT

Range Resolution Accuracy
300A 0.1A
1000A 1A
Overload Protection: 1200A for 60 seconds maximum. Frequency range: 50Hz to 60Hz.

DC CURRENT

Range Resolution Accuracy
300A 0.1A < 600A ±2.0% of rdg ± 5 digits
±0.8% of rdg ± 1 digit
±1.0% of rdg ± 5 digits
< 600A ±2.0% of rdg ± 10 digits > 600A ±3.0% of rdg ± 10 digits
Page 12
1000A 1A > 600A ±3.0% of rdg ± 5 digits
Overload Protection: 1200A for 60 seconds maximum.
-9-

RESISTANCE

Range Resolution Accuracy
300Ω 0.1Ω
3kΩ 1Ω
30kΩ 10Ω
300kΩ 0.1kΩ
3MΩ 1kΩ
30MΩ 10kΩ ±2.5% of rdg ± 10 digits
Maximum Open Circuit Voltage: 1.3V Overload Protection: 250V dc or rms. ac for all ranges.

FREQUENCY

Range Resolution Accuracy
30kHz 10Hz ±2.0% of rdg ± 10 digits Sensitivity: 200mV rms. Input Limit: 250V ac.

AUDIBLE CONTINUITY AND DIODE

Range Description
If continuity exists (about less than 18Ω), built-in buzzer will sound. Show the approx. Forward voltage of the diode.

REPLACING THE BATTERY

WARNING

Before attempting to open the case of battery, always be sure that test leads have been disconnected from measurement circuits. Close case and tighten
±2.0% of rdg ± 10 digits
Page 13
screws completely before using the meter to avoid electrical shock hazard. If “ ” appears on display, it indicates that the battery should be replaced. Use the following procedur e to replacing the battery:
-10-
1. Disconnect test leads from any live source, turn the rotary switch to OFF,
and remove the test leads from the input terminals.
2. The battery cover is secured to the bottom case by a screw. Using a
screwdriver, remove the screw from the battery cover and remove the battery cover.
3. Remove battery and replace with a new equivalent 9 volt battery.
4. Replace the battery cover and reinstall the screw.
ACCESSORIES
Operator’s instruction manual
Set of test leads
Gift box
9 volt battery. NEDA 1604 6F22 006P type
CAUTION:
Using this appliance in an environment with a strong radiated radio-frequency electromagnetic field (app roximat el y 3V/m ),may in fluen ce its measur ing acc ura cy. The accuracy can be reduced to ± (12% of reading + 6 digits).
The measuring result can be strongly deviating from the actual value.
The measuring result can be strongly deviating from the actual value.