755-502revA
Printed in USA 3/06 © 2006
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or
workmanship for a period of 1 year from date of original installation, not
to exceed 18 months from the date of manufacture.
Any component which proves to be faulty in material and/or
workmanship will be replaced or repaired (at the option of Prince Castle,
Inc.) without cost to the customer for parts and labor. This equipment is
portable; charges for on-location service (e.g., trip charges, mileage) are
not included in the provisions of this warranty.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor to be performed during regular work hours. Overtime
premium (the incremental amount) will be charged to the customer.
•
Damage caused by carelessness, neglect and/or abuse (e.g., dropping,
tampering or altering parts, equipment damaged in shipment, by fire,
flood or an act of God) is not covered under this warranty.
• All problems due to operation at voltages other than that specified on
equipment nameplates are not covered by this warranty. Conversion
to correct voltage is the customer’s responsibility.
•
This equipment must be serviced by Prince Castle Authorized Service
Agency or a Prince Castle Service Technician during the warranty
period.
Operation
Manual
Product Identification
Multi-display 8-Channel Timer
755-HM8
The Prince Castle Multi-display 8-Channel Timer offers
total control over the food preparation process. Both
auditory and visual signals are used to alert busy staff
people when specific processes are complete. Multiplechannel timers make multi-tasking easy and foolproof, a
cost-effective way to minimize food spoilage!
The power cord on this product is rated for a maximum surface
temperature of 194°F (90°C). If the cord comes into contact with the fryer
or rethermalizer or any other heated surface, it may be damaged and/or
cause damage to the product and/or injury to the user. The power cord
may also be damaged if placed directly in the path of the high
temperature exhaust emitting from the flue of the fryer or rethermalizer.
Damage resulting from any such misuse may result in a voided Warranty
at the sole discretion of the manufacturer.
Product Identification ...........................................1
Safety Information ...............................................1
Important! ........................................................... 1
Installation.......................................................... 1
Operation ...........................................................2
Channel Defaults .................................................2
Programming....................................................... 3
Miscellaneous Settings ......................................... 5
Cleaning............................................................. 5
Parts Identification / Function................................ 6
LIMITED WARRANTY (cont.)
TABLE OF CONTENTS
355 East Kehoe Blvd. • Carol Stream, IL 60188
Phone: 630-462-8800 • Toll Free: 1-800-PCASTLE • Fax: 630-462-1460 • www.princecastle.com
Safety Information Important!
WARNING: Indicates information important to the proper
operation of the unit. Failure to observe may result in damage to
the equipment and/or severe bodily injury or death.
CAUTION: Indicates information important to the operation
of the unit. Failure to observe may result in equipment damage.
Installation
Remove the unit from the carton and inspect for signs of
damage. If there is damage to the unit:
•
Notify the freight carrier (e.g., UPS) within 24 hours of delivery,
•
Save carton and packaging materials for inspection purposes,
•
Contact your local dealer, or if purchased directly, the Prince
Castle Sales Department at 1-800-722-7853 or 630-462-8800 to
arrange for a replacement unit.
Prince Castle reserves the right to change specifications and
product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or
replacements for previously purchased equipment.
NOTE: When installing this unit, the ambient temperature at the
mounting site should not exceed 100°F (37.8°C).
CAUTION
All electrical connections must be in accordance with local
electrical codes and any other applicable codes.
Plug the unit into an applicable electrical receptacle.

Multi-display 8-Channel Timer
755-HM8
Each of the 8 channels of the 755-HM8 timer operates in an identical
1
manner.
Press a channel button to activate a timing cycle (a short beep sounds).
To cancel any operation in progress, press the related channel button
three times in quick succession.
Operation
The timer counts down from the programmed time value of the first duty function. Every three to five
seconds during the countdown the display briefly shows the name of the current duty function and
then returns to the remaining time value. When the time value reaches 0:00, an alarm sounds (if
enabled) and the display alternates between the name of the just completed function and 0:00. The
alarm can be set to function in one of several possible manners for each enabled duty function (see
section on alarm programming). Each duty function is also equipped with an alert function. When
the programmed alert time is reached during the countdown (see section on Alert Programming), an
alarm sounds for approximately five seconds and the associated LED flashes.
2
Each channel has a multi-colored LED indicator that shows the status
of the current duty function. The indicator has three colors: green,
3
yellow, and red. The indicator is green during the first 70% of the
countdown for the current duty function. It changes to yellow during
the next 20% of the countdown. It is red during the last 10% of the
countdown and begins to flash when the countdown is completed.
This sequence is repeated for each enabled duty function (maximum of six)
of this channel. If a duty function’s time value is set to 0:00 (see section on
programming) this function and all subsequent functions for this channel
are disabled and not part of the channel’s timing sequence.
NEVER use any instrument or object to activate the channel buttons.
Press the buttons with your finger ONLY. Such misuse may damage
the unit, voiding the Warranty.
Printed in USA 3/06 © 2006
Ch. 1
Function Name Time Function Name Time Function Name Time Function Name Time
1 Fry :42 1 Fry 5:45 1 Fry 2:45 1 Fry 0:25
2 Dr_n :30 2 Dr_n 0:30 2 Dr_n :30 2 Dr_n 0:50
3 Hold 15:00 3 Cool 10:00 — — — — — —
Ch. 2
Function Name Time Function Name Time Function Name Time Function Name Time
1 Fry :42 1 Fry 5:45 1 Fry 0:25 1 Fry 0:30
2 Dr_n :30 2 Dr_n 0:30 2 FL_T 0:05 2 Dr_n 0:10
3 Hold 15:00 3 Cool 10:00 3 Dr_n 1:00 — — —
8-Channel Timer Operation & Pre-Programmed Settings
Ch. 3
Ch. 4
Channel Defaults
Press the button of the channel with the flashing red indicator to cancel that channel’s alarm (may
be programmed to automatically cancel alarm). If another duty function is enabled (maximum of six)
and the alarm mode is set to continue (see section on alarm programming) the timer automatically
begins to count down the time value of this new duty function as soon as the previous duty function
is completed. This happens in the background even while the alarm from the previous duty cycle is
still activated. Only when the alarm is cancelled is the time value for the new duty function
displayed. As the countdown continues, every three to five seconds the display briefly shows the
name of the current duty function and then returns to the remaining time value.
FOR EXAMPLE: When the button for Ch. 1 is pressed, the timer begins counting down from 42 secs.
and the word “FRY” is displayed every 3-5 seconds. When the 42-sec. fry time has completed, an
alarm sounds. Pressing button #1 for turns off the alarm and automatically starts the next cycle: a
30-sec. cycle with the word “DR_N” displayed every 3-5 secs. At the end of the 30-sec. Drain cycle,
the alarm sounds again. Pressing button #1 will turn off the alarm and automatically start the last
cycle in the program: a 15:00 min. cycle with “HOLD” displayed every 3-5 secs. At the end of the
Hold cycle, a final alarm will sound. Pressing button #1 will turn off the alarm and the timer will
return to the ready position, with “- - - -” displayed.
755-
502revA
Ch. 5
Ch. 6
Ch. 7
Ch. 8
Printed in USA 3/06 © 2006
2
755-
502revA