Prince Castle 741-TCE Installation Manual

Operating Instructions
Model No. 741-TF, 741-TCE &
741-TGB 2, 4, 8 & 12
Channel Series (Merlin II)
Single Function Timers
Channel Series
Prince Castle’s second generation of Merlin Timers feature a new slim design which gives you mounting flexibility . The 740 Series Timers are designed so each channel can be programmed independently, and used simultaneously. The timers are simple to program and simple to use. The push of a button activates each channel, and a alarm and multi-colored flashing channel buttons alert the operator when timing is complete.
Electrical
741-Series
230 Volts 50 – 60 Hz
TABLE OF CONTENTS
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Displays and Indicators . . . . . . . . . . . . . . . . . . . . 2
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Exploded View . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Mode d’emploi . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Betriebsanweisungen . . . . . . . . . . . . . . . . . . . . . . 12
Istruzioni per il funzionamento. . . . . . . . . . . . . . . . 17
Instrucciones de operación . . . . . . . . . . . . . . . . . . 22
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or workmanship for a period of two years from date of original installation, not to exceed 30 months from date of shipment from our factory.
Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts or labor.
This warranty is subject to the following exceptions/ conditions:
• This equipment is portable, charges for on location service (e.g. trip charges and mileage) are not included in the provisions of this warranty.
• Use of any non-genuine Prince Castle parts voids this warranty. All genuine Prince Castle replacement spare parts are warranted for ninety (90) days from date of purchase.
• All work must be performed by an authorized Prince Castle Service Agency. Failure to do so will void this warranty.
• Damage caused by careles sn es s , neg lec t, and /or abuse (e.g., dropping, tampering or altering parts), equipment damaged in shipment, by fire, flood or an act of God is not covered under this warranty.
Printed in 2004 Prince Castle Inc.
355 East Kehoe Blvd. • Carol Stream, IL 60188 USA
Telephone: 630-462-8800 • Fax : 630-462-1460
Toll Free: 1-800-PCASTLE
741-500FGISrevA
INSTALLATION
CONTROLS
1. After you have removed the timer from the carton, inspect the unit for signs of damage. If there is damage to the unit:
• Notify carrier within 24 hours after delivery.
• Save carton and packing materials for
inspection purposes.
• Contact your local dealer or, if purchased
directly, the Prince Castle Customer Sales Department at 1-800-722-7853 to arrange for a replacement to be sent.
2. Verify that all parts have been received. Bracket Mounting screws provided.
3. To mount the timer, place mounting brackets in desired location. Scribe location of mounting holes, center punch, and drill holes. Attach timer to mounting brackets placing star washer between bracket and timer.
DISPLAYS AND INDICATORS
TIME
Display
CHANNEL
Display
H:M Indicates the time value is in Hours
M:S Indicates that the time value is in
LED
Indicators
Shows the time for the selected channel number.
Shows the channel number selected and in use. (The 741-T2 model does not have this display. )
and Minutes.
Minutes and Seconds. Located above each channel timer
button, these lights change color depending on the stage of the countdown.
Green = first 70% of countdown, Yellow = next 20% of countdown, Red = last 10% of countdown.
Channel
(Timer)
SCAN/UP
ARROW
SCAN/DOWN
ARROW
PRINCE
CASTLE
Logo
The 741-T2 has 2 channels, the 741-T4 has 4 channels, the 741-T8 has 8 channels and the 741T12 has 12 channels.
In the program mode, it increases time values for each channel. In the Run Mode, it is used in conjunction with logo button to increase the volume.
In the program mode, it decreases time values for each channel. In the Run Mode, it is used in conjunction with logo button to decrease the volume.
Activates Program Mode and used to adjust the alarm sound level.
PROGRAMMING
1. To program, press and hold the PRINCE CASTLE logo for six seconds. The TIME display
changes from ---- to See figure 1.
figure 1
2. Select and press the timer channel to be programmed. The LED indicator for the selected button will turn yellow and a beep will sound. The selected channel number will be displayed in the CHANNEL display, the current programmed time for that channel will be displayed in the TIME display , and the time v alue will indicate either H:M OR M:S. See figure 2.
Prog
, and a beep will sound.
741-500FGISrevA 2
figure 2
3. To change the program time for the selected channel, use the S CAN/UP Arrow or the SCAN/
DOWN Arrow button.
IMPORTANT
M:S to Hours and Minutes H:M. Press and hold the
SCAN/UP Button. When the display reaches 59:59 it will automatically change to 1:00 Hour and the LED will switch from M:S to H:M. The program value for the H:M indicator is from 1:00 hour to 17 hours: 59 minutes. See figures 3 and 4.
: To change from Minutes and Seconds
figure 3
4. To program another channel, press the desired channel button. Repeat programming procedures in steps 2 and 3. See figure 5.
figure 5
5. When finished programming each desired channel, momentarily press the PRINCE CASTLE logo to end the Program Mode. This saves the program changes you have made for all channels. See figure 6.
figure 6
figure 4
6. You can change the sound level of the alarm in
RUN MODE. Press and hold the PRINCE CASTLE logo; then, within six seconds, press either the SCAN UP Arrow button or the SCAN DOWN Arrow button. The SCAN UP Arrow button
adjusts the sound level to the louder alarm, and the SCAN DOWN Arrow button adjusts the sound level to the lower alarm. See figure 7.
figure 7
3 741-500FGISrevA
OPERATION
1. Press a channel button to activate a timing cycle. (All channels can be activated and running at the same time.) The time channel number with the least amount of time remaining will be displayed in the time remaining will countdown in the display, and the time value illuminated. See
figure 8
2. Press the desired channel button three times within five seconds to cancel an active timing cycle.
IMPORTANT
colored LED indicator shows the status of the timer. The indicator has three colors: green, yellow, and red. The LED will be green during the first 70% of the countdown. It changes to yellow during the next 20% of the countdown. It will be red during the final 10% of the countdown, and will start flashing red once the time has run out.
3. The timer will countdown from the programmed value to zero. At zero, the display flashes and the alarm sounds. See figure 9.
: The channel timer button’s multi-
figure 9
figure 8
CHANNEL
M:S
or
.
display, its
TIME
H:M
will be
End
IMPORTANT
the operator when the timing cycle is complete: The CHANNEL display shows the channel associated with the alarm. The TIME display shows LED indicator in the channel button flashes red.
4. When the timing cycle is complete, and the alarm sounds, press the channel button with the flashing red indicator to cancel the alarm. See figure 10.
: There are three indicators that signal
End
. The
figure 10
5. The scan feature is used to check the time values on other active channels. There are two different ways to scan active channels. Press the SCAN/ UP or SCAN/DOWN button or press any of the active timer CHANNEL buttons. If no other button is pressed within 5 seconds, the display will change to show the timer with the least amount of time left. See figure 11.
figure 11
741-500FGISrevA 4
CLEANING
1. Do not allow grease to build up on the timer, wipe it down daily with clean damp cloth.
IMPORTANT
cleaners on your timer, this may cause damage to the overlay.
: Do not use abrasive or chemical
PARTS LIST
Item Part Number Description
7 88-653-2-4SA Speaker Assy. 10 741-021 I.C. Connector 11 85-101-04S Power Supp ly PCB 12 740-9S PCB, Main (T2)
740-225S PCB, Main (T4, T8 & T12) 15 735-241S Mounting Bracket Kit 16 70-048 Knob 17 735-240S Switch Panel Assy. (T2)
735-211S Switch Panel Assy. (T4)
740-026S Switch Panel Assy. (T8)
735-208S Switch Panel Assy. (T12) 19 94-301 Label 20 86-226 Spacer 24 69-07 9S Rivet (Pkg. of 2) — 72-200-1S Line Cord (CE) Not Shown — 72-200-2S Line Cord (GB) Not Shown
EXPLODED VIEW
20
11
19
16
12
24
17
15
7
15
16
10
5 741-500FGISrevA
TROUBLESHOOTING GUIDE
PROBLEM CAUSE SOLUTION
A. No displays or indicators lit. Unit unplugged.
Store’s circuit breaker blown. Defective transformer. Circuit inoperable.
B. Absence of Audio Alarm. Speaker inoperable.
Circuit inoperable.
C. Unit will not ent er program mode.
Prog
Display does not show “
”.
D. Unit enters pr ogram mode. Display
shows “
Prog
”, but cannot change
times.
E. Unable to start, stop, or store timer
All channels are still counting. Logo Switch inoperable. The channel is still counting . Arrow Switch inoperable. Circuit inoperable.
Circuit inoperable. Replace Switch Panel. If problem presets in program mode. Missing or abnormal characters in displays.
WIRING DIAGRAM 741-T2
Plug unit in. Reset breaker. Replace Power Supply Board. Replace Main Circuit Board. Replace Speaker. Replace Main Circuit Board. Wait until channels are in stop mode. Replace Switch Panel. Wait until channel is in stop mode. Replace Switch Panel. Replace Main Circuit Board.
persists, replace Main Circuit Board.
MEMBRANE SWITCHMAIN PCB
POWER SUPPLY PCB
RED
BLACK
GROUND
GRN/YEL
BLUE
BROWN
SPEAKER
POWER INLET
SPEAKER
YELLOW
BLACK
741-500FGISrevA 6
INSTALLATION
COMMANDES
1. Après avoir extrait le minuteur de son emballage, vérifier qu’il est en bon état. En cas de dommages de l’appareil:
• Notifier le transporteur dans les 24 heures qui
suivent la livraison.
• Conserver le carton et les matériaux
d’emballage à des fins d’examen.
• Contacter le revendeur local ou, en cas d’achat
direct, le Service à la clientèle Prince Castle au (+1) 800-722-7853 afin d’obtenir l’envoi d’un appareil de rechange.
2. Vérifier que toutes les pièces ont été reçues. Les vis de fixation des supports sont fournies.
3. Pour poser le minuteur, placer les supports de fixation à l’endroit souhaité. Tracer l’emplacement des trous de fixation, marquer au pointeau et percer. Poser les supports de fixation en plaçant une rondelle éventail entre le support et l’appareil.
ÉCRANS ET INDICATEURS
Écran
TIME
Écran
CHANNEL
H:M Indique que la durée est affichée en
M:S Indique que la durée est affichée en
Voyants
lumineux
Affiche la durée pour le canal sélectionné.
Affiche le numéro de canal sélectionné et en cours d’utilisation (le modèle 741-T2 ne comporte pas cet écran).
Heures et Minutes.
Minutes et Secondes.
Placés au-dessus de chaque touche de canal, ces voyants changent de couleur en fonction de l’avancement du compte à rebours
Vert = premiers 70% du compte à rebours, Jaune = 20% suivants du compte à rebours, Rouge = derniers 10% du compte à rebours.
Canal
(Minuteur)
FLÈCHE
SCAN/HAUT
FLÈCHE
SCAN/BAS
Logo
PRINCE
CASTLE
Le 741-T2 comporte 2 canaux, le 741-T4 4 canaux, le 741-T8 8 canaux et le 741T12 12 canaux.
En mode Programmation, cette touche permet d’augmenter la valeur de durée d’un canal. En mode Exécution, elle s’utilise en association avec la touche logo pour augmenter le volume.
En mode Programmation, cette touche permet de diminuer la valeur de durée d’un canal. En mode Exécution, elle s’utilise en association avec la touche logo pour diminuer le volume.
Cette touche active le mode Programmation et sert à régler le niveau sonore de l’alarme.
PROGRAMMATION
1. Pour programmer, tenir la touche logo PRINCE CASTLE enfoncée pendant six secondes.
L’écran TIME passe de ---- à sonore est audible. Voir figure 1.
figure 1
2. Appuyer sur la touche du canal minuteur à programmer. Le voyant lumineux de la touche sélectionnée s’allume en jaune et un bip sonore est audible. Le numéro du canal sélectionné s’affiche sur l’écran CHANNEL, la durée actuellement programmée pour ce canal s’affiche sur l’écran TIME, cette valeur s’affichant en mode
H:M OU M:S. Voir figure 2.
Prog
et un bip
7 741-500FGISrevA
figure 2
3. Pour changer la durée programmée du canal sélectionnée, utiliser le touche flèche SCAN/
HAUT ou flèche SCAN/BAS.
IMPORTANT
Minutes et Secondes M:S à Heures et Minutes H:M, tenir la touche SCAN/HAUT enfoncée. Lorsque la valeur atteint 59:59, elle passe automatiquement à 1:00 heure et le voyant lumineux passe de M:S à H:M. La valeur de durée pour le voyant H:M s’étend de 1:00 heure à 17 heures: 59 minutes. Voir figures 3 and 4.
: Pour passer du mode d’affichage
figure 3
4. Pour programmer un autre canal, appuyer sur la touche du canal souh aité. Répéter les opérations de programmation des étapes 2 et 3. Voir
figure 5
figure 5
5. Une fois que chaque canal souhaité est programmé, appuyer sur le logo PRINCE CASTLE pour quitter le mode Programmation. Ceci enregistre les modifications effectuées sur tous les canaux. Voir figure 6.
figure 6
.
figure 4
6. Le niveau sonore de l’alarme peut être m odifié en
MODE EXÉCUTION
PRINCE CASTLE
secondes, appuyer sur la touche flèche
HAUT
ou sur la touche flèche touche flèche sonore de l’alarme, la touche flèche diminue le niveau sonore de l’alarme. Voir
figure 7
SCAN HAUT
.
. Tenir la touche logo
enfoncée ; dans les six
SCAN
SCAN BAS
augmente le niveau
SCAN BAS
. La
figure 7
741-500FGISrevA 8
FONCTIONNEMENT
1.
Appuyer sur un bouton de canal pour activer le cycle de minutage correspondant (tous les canaux peuvent être activés et s’exécuter en même temps). L’écran CHANNEL affiche le numéro du canal minuteur dont la durée restante est la plus courte, l’écran TIME affiche le compte à rebours correspondant et le voyant de valeur de durée M:S ou H:M s’allume selon le cas.
figure 8
.
figure 8
2. Appuyer sur la touche du canal souhaité trois fois dans les cinq secondes pour annuler un cycle de minutage actif.
IMPORTANT
touche de canal minuteur indique l’état du minuteur. Ce voyant a trois couleurs : vert, jaune et rouge. Le voyant s’affiche en vert pendant les premiers 70% du compte à rebours. Il passe au jaune durant les 20% suivants du compte à rebours. Il s’allume en rouge durant les derniers 10% du compte à rebours et clignote en rouge une fois que la durée est écoulée.
3. Le minuteur compte à rebours depuis la valeur programmée jusqu’à zéro. À zéro, l’écran affiche
End
déclenche. Voir figure 9.
: Le voyant lumineux multicolore d’une
en clignotant et l’alarme sonore se
figure 9
Voir
IMPORTANT
l’opérateur la fin de cycle du minuteur : L’écran CHANNEL affiche le numéro de canal associé à l’alarme. L’écran TIME affiche lumineux de la touche du canal clignote en rouge.
4. À la fin du cycle du minuteur, l’alarme sonore se déclenche ; appuyer sur la touche de canal dont le voyant clignote en rouge pour couper l’alarme. Voir figure 10.
: Il y trois indicateurs signalant à
End
. Le voyant
figure 10
5. La fonction de consultation permet de vérifier les valeurs de durée des autres canaux actifs. Il y a deux moyens différents de consulter les canaux actifs. Appuyer sur la touche SCAN/HAUT ou SCAN/BAS ou sur la touche de l’un quelconque des canaux minuteurs actifs. Si aucune autre touche n’est enfoncée dans les 5 secondes, l’écran revient à l’affichage du minuteur de durée restante la plus courte. Voir figure 11.
figure 11
NETTOYAGE
1. Ne pas laisser de graisse s’accumuler sur le minuteur, l’essuyer chaque jour avec un chiffon humide propre.
IMPORTANT
revêtement, ne pas utiliser de détergent abrasif ou chimique sur le minuteur.
9 741-500FGISrevA
: Pour éviter d’endommager le
Loading...