Prince Castle 741-T2HW Installation Manual

OPERATING
Hand-Washing Timer 741-T2HW-Series
Prince Castle’s second generation of Merlin Timers feature a new slim design which gives you mounting flexibility. The Prince Castle 741-T2HW Handwashing Timer is pre-programmed to help start handwashing procedures as soon as it is plugged in. Each channel is set for one hour cycle, but can be easily programmed to fit specific operational stan­dards. Once started, the timer will continue to reset itself after sounding an alarm. There is no need to cancel and restart.
Installation..................................................................... 2
Programming................................................................. 2
Operation.......................................................................3
Cleaning ........................................................................ 3
Parts List ....................................................................... 4
Troubleshooting ............................................................ 4
Exploded View.............................................................. 5
Wiring Diagram ............................................................. 5
LIMITED WARRANTY
This product is warranted to be free from defects in material and/or workmanship for a period of 1 year from date of original installation, not to exceed 18 months from the date of manufacture.
Any component which proves to be faulty in material and/or workmanship will be replaced or repaired (at the option of Prince Castle, Inc.) without cost to the customer for parts and labor.This equipment is portable; charges for on-location service (e.g., trip charges, mileage) are not included in the provisions of this warranty.
This warranty is subject to the following exceptions/conditions:
• Use of any non-genuine Prince Castle parts voids this warranty.
• All labor to be performed during regular work hours. Overtime premium (the incremental amount) will be charged to the customer.
• Damage caused by carelessness, neglect and/or abuse (e.g., dropping, tampering or altering parts, equipment damaged in shipment, by fire, flood or an act of God) is not covered under this warranty.
• All problems due to operation at voltages other than that specified on equipment nameplates are not covered by this warranty. Conversion to correct voltage is the customer’s responsibility.
• This equipment must be serviced by Prince Castle Authorized Service Agency or a Prince Castle Service Technician during the warranty period.
ELECTRICAL
741-T2HWCE, 741-T2HWGB
230 Volts 50 Hz 10 Watts Single Phase
741-501 revA
355 East Kehoe Blvd. Carol Stream, IL 60188
Tel: (630) 462-8800 Fax: (630) 462-1460
Toll Free: 1-800-PCASTLE
Printed in USA 3/06 © 2006
INSTALLATION
1. After you have removed the timer from the carton, inspect the unit for signs of damage. If there is damage to the unit:
SCAN/DOWN
ARROW
In the program mode, it decreases time values for each channel . In the run mode, it is used in conjunction with logo button to decrease the volume.
l Notify carrier within 24 hours after delivery. l Save carton and packing materials for inspection reasons. l Contact your Prince Castle dealer or the Prince
Castle Customer Sales Department at 1-800-722­7853, if purchased directly.
2. Verify that all parts have been received. Mounting
brackets and hardware provided
3. To mount the timer, place mounting brackets in desired location. Scribe location of mounting holes, center punch, and drill holes. Attach timer to mounting brackets placing star washer between bracket and timer.
Note: Timers should be plugged into a dedicated outlet. No
other equipment should be operating on this line (i.e. fryers, refrigerators, cash registers, etc.).
CAUTION: Solid state components in this timer are de-
signed to operate reliably in a temperatue range up to 150oF (65.6oC. When installing this timer, it should be confirmed that the ambient temperatures at the mount­ing site do not exceed 150oF (65.6oC).
PRINCE
CASTLE
Logo
Activates Program Mode and used to adjust the alarm sound level.
PROGRAMMING
1. To program, press and hold the PRINCE CASTLE logo for six seconds. The TIME display changes from ---- to Prog, and a beep will sound. See figure 1.
figure 1
P r o g
Note: The timer leaves the factory preset at 60:00
minutes.
DISPLAYS AND INDICATORS
TIME
Display
H:M
M:S
LED
Indicators
Shows the time for the selected channel number.
Indicates the time value is in Hours and Minutes.
Indicates that the time value is in Minutes and Seconds.
Located above each channel timer button, these lights change color depending on the stage of the count­down. Green = countdown cycle, Red = auto reset cycle.
CONTROLS
SCAN/UP
ARROW
In the program mode, it increases time values for each channel . In the Run Mode, it is used in conjunction with logo button to increase the volume.
2. Select and press the timer channel to be pro­grammed. The LED indicator for the selected button will turn green and a beep will sound. The current programmed time for that channel will be displayed in the TIME display, and the time value will indicate either H :M OR M:S. See figure 2.
figure 2
1
8:00
3. To change the program time for the selected channel, use the SCAN/UP Arrow or the SCAN/ DOWN Arrow button.