-E ⇒ 40 channels AM/FM 4W (from 26,965Mhz to 27,405Mhz)
-d ⇒ 80 channels FM 4W/AM 1W (from 26,565Mhz to 27,405Mhz)
-EU ⇒ 40 channels FM 4W/AM 1W (from 26,965Mhz to 27,405Mhz)
-EC ⇒ 40 channels FM 4W (from 26,965Mhz to 27,405Mhz)
-U ⇒ 40 channels FM 4W (from 26,965Mhz to 27,405Mhz)
40 channels FM 4W (from 27,60125Mhz to 27,99125Mhz)
-PL ⇒ 40 channels AM/FM 4W (from 26,960Mhz to 27,400Mhz)
-Channel step
-10KHz
-Class of emission
-AM(A3E)/FM(F3E)
-Power supply
-13,2V (from10,8V to 15,6V)
-Antenna impedance
-50Ω
-Dimensions(in mm)
-160(L)x160(H)x55(D)
-Weight
-1,1Kg
2-TRANSMISSION:
-Frequency allowance
-±300Hz
-Transmission interference
-Inferior to 4nW(-54dBm)
-Audio frequency response
-From 300Hz to 3kHz in AM/FM
-Emitted power in the adjacent channel
-Inferior to 20µW
-Microphone sensitivity
-Inferior to 10mV
-Current drain
-2A(in transmission mode with modulation)
-Modulated signal distortion
-Inferior to 2%
3-RECEPTION:
-Maximum sensitivity at 20dB sinad
-0,5µV(-113dBm) AM/FM
-Audio frequency response
-From 300Hz to 3kHz in AM/FM
-Adjacent channel selectivity
-Superior to 60dB
-Frequency image rejection
-Superior to 60dB
-Intermodulation response
-Superior to 54dB
-Maximum audio power
-5W
-Squelch sensitivity
-Threshold 0,2µV(-120dBm)/Tight 1mV(-47dBm)
-Current drain
-400mA nominal/1500mA maximum
ALIGNMENT PROCEDURE
(WALKER)
* VCO/PLL PORTION
- Alignment procedure
- Test points
- Frequencies chart
* TRANSMITTER
- Alignment procedure
- Test points
* RECEIVER
- Alignment procedure
- Test points
Test equipement required
Frequency counter 200 Mhz HF Generator
DC Volmeter BF Volmeter
Distortiometer HF Volmeter
Wattmeter - Dummy load Osilloscope
FM linear detector Load 8 Ω AF generator Sinad meter
Conditions of Measurements on HF Generator
Reception
AM mode: Level - 107 dBm Frequency 1 KHz with 60% of modulation.
FM mode: Level - 107 dBm Frequency 1 KHz with 1,2KHz of deviation.
Connect HF generator to jack antenna
adjusted at ( –107dBm 1KHz 60%),
connect sinad meter to jack EXT speaker
and adjust coils for maximum sensitivity(
≥ 20dB sinad).
Connect HF generator to jack antenna
adjusted at ( –107dBm 1KHz 1,2KHz
Dev),connect sinad meter to jack EXT
speaker and adjust L11 for maximum
sensitivity( ≥ 20dB sinad).
adjusted at ( –67dBm 1KHz 60%) and
adjust RT2 so that S9 on Smeter.
Connect HF generator to jack antenna
adjusted at ( –47dBm 1KHz 60%) and
adjust RT1 so that the signal is audible .
Connect sinad meter to jack EXT speaker,
adjust the ouput level of HF generator and
adjust RT401 to reach at the opening ASC
a sinad of 17dB±2dB.
RT2
RT1
RT401
L1
L10
L11
L3
L9
L6
L7
L8
WALKER