Premier AA-1821, AA-1823 Instruction Manual

Page 1
DEAR CUSTOMER
Congratulations for your purchase! Please read this manual carefully, and keep it for future reference. If you need extra support, please write to info@premiermundo.com
INSTRUCTION MANUAL
AIRE ACONDICIONADO DE PARED
AA-1821 AA-1823
Page 2
3
9
11 11
11 11
10 11
8
8
7
7
7
6
6
6
6
6
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
R
Page 3
3
(m/h)
3. * express series of H HS HSA HSE HSL HSF M.
4. Q is optional.
Exterior
6.35X0.6X3600(4000/5000/6000)
9.52X0.6X3600(4000/5000/6000)
420
940 940
4.4
4.4 1410
7.1
9.5 26~40
16.5X80.2X26.2
26X76X54
33
50
12~17
18000/5300
840
2000 2000
9.5
9.5 3000
14.9
1PH 208V-230V~/60Hz
198~242
R22
16 43~46
19X115.3X33.5
48
54
28~35
24000/ 7000
1100
2700 2650
12.5
12.1 3830
19.3
19 44~49
51
61
35~47
19X99.5X32
30X80X69
12.7X0.8X3600(4000/5000/6000)
15.88X0.8X3600(4000/5000/6000)
9.52X0.6X3600(4000/5000/6000)
12000/3300
540
1270 1230
5.9
5.7 1910
9.6
10.5 30~41
17.6X89X29.6
38
51
14~23
9600/2800
13000/3850
9000/2500
19800/5800
26300/ 7700
ASW-H09A2/*(Q)
ASW-H12A2/*(Q)
ASW-H18B2/#(Q)
ASW-H24B2/#(Q)
ASW-H09A2/*(Q)
AS-H09A2/*(Q)
ASW-H12A2/*(Q)
AS-H12A2/*(Q)
ASW-H18B2/#(Q)
AS-H18B2/#(Q)
ASW-H24B2/#(Q)
AS-H24B2/#(Q)
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 1
R
Page 4
3. * express series of H HS HSA HSE HSL HSF M.
4. Q is optional.
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 2
R
3
(m/h)
Exterior
9000/2500 18000/5300
24000/7000
440 840 1100
12000/3300
540
50
1PH 208V-230V~/60Hz
940
4.4
16.5X80.2X26.2
9.5
26~40
32
9.52X0.6X3600(4000/5000/6000)
12~17
2000 2600
9.5 12
R22
19X99.5X32
19X115.3X33.5
16
19
43~46
44~49
47
9.52X0.6X3600(4000/5000/6000)
15.88X0.8X3600(4000/5000/6000)
12.7X0.8X3600(4000/5000/6000)
198~253
28~35
6.35X0.6X3600(4000/5000/6000)
1410
7.1
3000
14.9
47
3830
19.3
35~47
1230
5.5
1870
9.5
17.6X89X29.6
30X80X69
10.5
30~41
37
14~23
26X76X54
ASW-09A2/*(Q)
ASW-24B2/#(Q)
ASW-09A2/*(Q)
AS-09A2/*(Q)
ASW-12A2/*(Q) ASW-12A2/*(Q)
AS-12A2/*(Q)
ASW-18B2/#(Q) ASW-18B2/#(Q)
AS-18B2/#(Q)
ASW-24B2/#(Q) AS-24B2/#(Q)
51
54
57
Page 5
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 3
R
Page 6
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 4
R
Page 7
ASW-(H)18B2/M
ASW-(H)24B2
AS-(H)18B2/# AS-(H)24B2/#
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 5
R
Page 8
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 6
R
Page 9
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 7
R
Page 10
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 8
R
Page 11
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 9
R
Page 12
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 10
R
Page 13
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Pagina 11
R
Page 14
15998001531
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
R
Page 15
DEAR CUSTOMER
Congratulations for your purchase! Please read this manual carefully, and keep it for future reference. If you need extra support, please write to info@premiermundo.com
INSTRUCTION MANUAL
SPLIT TYPE ROOM AIR CONDITIONER
AA-1821 AA-1823
Page 16
CONTENTS
Specifications -----------------------------------------------------------1 Parts Description--------------------------------------------------------5
-------------------------------------------------------6
Usage -------------------------------------------------------------------6
--------------------------------------------6
------------------------------------------6
Items of attention-------------------------------------------------------7
Maintenance ------------------------------------------------------------9
Installation ------------------------------------------------------------13
--------------------------------------------7
--------------------------------------------------8
------------------------------------------------13
----------------------------------------------13
-------------------------------------------------13
---------------------------------------------------------7
Outdoor Unit
Remote controller usage Hand control operation
Checking before usage
Optimal operation
Failure type and methods of resolution Non-air conditioner trouble Cleaning Maintenance
Guide of customer
Installation position Items of attention
--------------------------9
-------------------------------------12
----------------------------------------------------------12
------------------------------------------------------12
-------------------------------------------------6
Working condition
Safety rules
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
R
Page 17
26~39
10~15
16.5X80.2X26.2
R22
3200/12000
520
1270 1230
5.9
5.7 1910
9.6
17.6X89X29.6
1PH 220V-240V ~/50Hz
30~41
51
198~264
14~23
ASW-H07B4/* ASW-H09A4/*
26X76X54
ASW-H07B4/*
AS-H07B4/*
ASW-H09A4/*
AS-H09A4/*
ASW-H12A4/* ASW-H12A4/*
AS-H12A4/*
ASW-H12B4/*
AS-H12B4/*
3500/12000
4000/13600
540
1300 1320
6.1
6.2 1920
9.7
30~41
51
16~24
2500/9000 2800/9600 420
940
940
4.4
4.4 1410
7.1
26~40
50
12~17
3520/13000
2300/7000 2650/9000 380
900 920
4.2
4.3 1350
6.8
50
ASW-H12B4/*
(W/Btu/h)
(W/Btu/h)
6.35X0.6X3000(3600/4000/5000/6000)
`
9.52X0.6X3000(3600/4000/5000/6000)
or no signal.
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 1
R
Page 18
or no signal.
2300/7000
/ 380
880 /
4.1 / 1230
6.2
26~39
50
10~15
2500/9000
/ 420
920 /
4.3 / 1320
6.7
26~40
50
12~17
16.5X80.2X26.2
R22
3200/12000
/
540
1230 /
5.8 / 1910
9.6
17.6X89X29.6
1PH 220V-240V ~/50Hz
30~41
51
198~264
14~23
ASW-07B4/* ASW-09A4/*
ASW-12B4/*
26X76X54
(W/Btu/h)
(W/Btu/h)
ASW-07B4/*
AS-07B4/*
ASW-09A4/*
AS-09A4/*
ASW-12A4/* ASW-12A4/*
AS-12A4/*
ASW-12B4/*
AS-12B4/* 3500/12000
/
540
1320 /
6.2 / 1920
9.7
30~41
52
16~24
6.35X0.6X3000(3600/4000/5000/6000)
9.52X0.6X3000(3600/4000/5000/6000)
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 2
R
Page 19
ASW-H18A4/#
4800/16000
5400/18500
780
1950 1850
9.0
8.5 2930
14.8
41~43
53
24~32
ASW-H18A4/#
AS-H18A4/#
R22
21.5X115X32
1PH 220V-240V ~/50Hz
198~253
(W/Btu/h)
(W/Btu/h)
ASW-H18B4/# ASW-H18B4/#
AS-H18B4/#
5300/18000
5800/19800
840
2000 2000
9.5
9.5 3000
14.9
43~46
26~36
ASW-H24A4/# ASW-H24A4/#
AS-H24A4/#
ASW-H24B4/# ASW-H24B4/#
AS-H24B4/#
30X80X69
6000/22000
6600/22500
1000
2400 2300 11
10.5 3450
17.4
44~46
30~40
20X100.5X32
54
55
7000/24000
7700/26300
1100
2700 2780
12.5
12.3 3830
19.3
44~49
35~47
57
6.35x0.6x3000(3600/4000/5000/6000)
9.52x0.6x3000(3600/4000/5000/6000)
12.7x0.7x3000(3600/4000/5000/6000)
15.88x0.75x3000(3600/4000/5000/6000)
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 3
R
Page 20
ASW-18A4/#
4800/16000
780
1950
/
9.0 /
2930
14.8
41~43
53
24~32
ASW-18A4/#
AS-18A4/#
R22
21.5X115.0X32
1PH 220V-240V ~/50Hz
198~264
(W/Btu/h)
(W/Btu/h)
ASW-18B4/# ASW-18B4/#
AS-18B4/#
5300/18000
800
1950
/
9.0 /
2930
14.8
43~46
28~35
ASW-24A4/# ASW-24A4/#
AS-24A4/#
ASW-24B4/# ASW-24B4/#
AS-24B4/#
30X80X69
6000/22000
1000
2400
/
11
/
3450
17.4
44~46
30~40
20X100.5X32
54
55
7000/24000
/
1100
2700
/
12.3 /
3830
19.3
44~49
35~47
57
/ / /
6.35x0.6x3000(3600/4000/5000/6000)
9.52x0.6x3000(3600/4000/5000/6000)
12.7x0.7x3000(3600/4000/5000/6000)
15.88x0.75x3000(3600/4000/5000/6000)
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 4
R
Page 21
Indoor Unit
Indoor Unit
Outdoor Unit
Installation board Middle frame Indication light and signal receiver Front panel Horizontal airflow direction vane
Vertical airflow direction vane(inner)
Air filter
Drain pipe
Pipe and Drain pipe Cut-off valve Outlet cover
Note:
Take the actual appearance of standard model as the criteria,so maybe the appearance in the Fig. Is different with what you buy.
11
12
Outdoor Unit
Parts Description
1
Fig.1
Pipe protection ring
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 5
R
Page 22
Outdoor Unit
Usage
Working condition
Remote controller usage
Hand control operation
See Air-conditioner Remote Controller Instruction
Forced operation
When the remote controller does not work, use the forced operation as the following steps.
In case the remote controller isn t at hand ,and the air­conditioner is operating. Press the forced operation button to make it stop. Press the button a second time, it starts to operate. In case the remote controller does not work, press the
forced operation button,which is automatic operation.
The airflow direction is adjusted automatically.
Cooling
Heating
Indoor
Outdoor
Indoor Outdoor
Maximum: Minimum:
Maximum: Minimum:
Maximum: Minimum:
Maximum: Minimum:
DB/WB DB/WB
DB/WB DB/WB
DB/WB DB/WB DB/WB DB/WB
32 /23 43 /26 27 ­24 /18
21 /15 21 /15 20 -
-5 /-6
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 6
R
Page 23
Wind direction adjusting
1.Horizontal wind direction adjusting Use hands to move the vane and change the horizontal wind direction.
Note:
Adjust the horizontal wind direction before the air-conditioner starts. Don t reach your finger into air-out window when the air-conditioner is operating.
2.Vertical wind direction adjusting Refer to Remote Controller Usage Instruction for how to adjust vertical wind direction
through adjusting the horizontal airflow vane by remote controller.
Note
Adjust the vertical wind direction by remote controller. When you adjust the horizontal airflow vane by hand, the machine may cause problem.
When the air-conditioner stops, the horizontal wind vane will close the wind outlet of air­conditioner.
Please read carefully this instruction before using the air-conditioner,you are strict to operate according to the instr ction. Otherwise, it may be damage to the air-conditioner or to the other person s safety and property.
u
Items of attention
Make sure that air outlet and inlet are not blocked.
The earth wire is connected safely and reliably. The filter net is properly fixed.
Stop its using for a long time, please clean the filter net before starting the air-conditioner, see Maintenance for how to operate.
Checking before usage
Set the suitable temperature, especially when there are old people, children and patients in the room.
In the case the air-conditioner occurs closing down or gash due to the severe interference from outer environments such as auto and mobile phone etc.,please take off the plug and then plug in after several seconds to restart the air-conditioner.
Installation should always be carried out by specialist. The customers should not install the air-conditioner by themselves, Otherwise, it may be damage to the air-conditioner or to the other person s safety and property.
In order to properly use the air-conditioner ,please follow the Working condition in the instructions, otherwise, it may activate the inside protection, or lead to weeping, or decrease the cooling/heating efficiency.
Note
Safety rules
Generally ,keep the temperature difference between the inside and outside
within 5 .
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 7
R
Page 24
Make sure that air outlet and inlet are not blocked, or it may decrease the efficiency of the air-conditioner, even stops the operation of the system.
If the air filter is blocked, the cooling or heating capacity will be affected. Please regularly clean the air filter.
The primary power switch should be placed where is unavailable for child to prevent the child from the danger of electric shock.
Warning
In lighting storm weather, please cut off the primary power supply switch in order to prevent the machine from damage.
Before stop its using for long or the customer will leave the room for a long time, please cut off the primary power supply switch to avoid incident.
Liquid detergent or corrosive detergent should not be used for cleaning the machine and sprinkle water or other liquid onto it . Otherwise it may result in damages on the plastic components of the case, even electric shock.
ÉÁ µçÉÁ µç
Set the suitable temperature for a comfortable environment. Don't make the room too cold or too hot.
During the cooling operation, don't let the sunlight into the room, please pull down the window shades or veils.
Close the windows and doors. Otherwise, it decreases its cooling or heating capacity.
Please set the scheduled operation time with the remote controller.
Pay attention to the following items so as to ensure optimal operation of the system, detailed operation see the relevant content.
Optimal operation
Cut off the power supply switch
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 8
R
Page 25
In case th t abnormal phenomenon occurs such as unusual noise, smoke or electric leakage etc.,please immediately cut off the power supply and then contact with the local distributor don't try to repair it by yourself.
a
Keep the indoor unit and the remote controller dry to avoid short circuit , even fire accident.
Don t use and store flammable gas or liquid such as fixature,paint or gasoline close to the air-conditioner to avoid fire hazard.
Don't touch the swinging wind vanes, or it may clamp your finger and damage the driving parts of the wind vanes.
Don t split the fan cover to avoid the possible injury by the rotating fan at high speed. Don t let the child touch the air-conditioner to avoid the possible danger.
, ,
,
Don't put your hand or stick-shaped objects into the air outlet of the indoor and outdoor unit, otherwise, the rotating fan at high speed may cause injury to you.
Danger
Danger
Do not pull out the power cord, The damage of power cord will cause serious electric shock.
Do not operate with wet hands or in damp environment. it will cause electric shock.
Electric shock
In case the following situation, please immediately stop the operation of the air-conditioner and cut off the power supply, then contact distributor.
Failure type
Maintenance
Failure type and methods of resolution
The RUN light or other display light flashes rapidly and keep flashing after the plug is taken off and then plugged in.
The fuse blows repeatedly or the circuit breaker is activated repeatedly.
The remote controller does not work or the switch operates unusually .
Outside object or water comes into the air-conditioner.
Other abnormal phenomenon.
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 9
R
Page 26
In case the following situations, please deal with it according to the following methods, if it does not work, please contact distributor and inform the detailed failure.
The wind blowing out,but the cooling/ heating effect is bad
The wind blowing out,but it does not refrigerate
Failure
Start-up failure
The air inlet or outlet of machine is blocked
The air inlet or outlet of machine is blocked Compressor has three min tes protectionu
It doesn t reach the set time for start up Mistakes in temperature setting
The air filter is blocked by dust
The doors or windows are open
Mistakes in temperature setting
The power switch is released
The battery is exhausted
Power supply failure
The fuse is burnt
Causes
,
Wait for the recovery of power supply
Wait or eliminate the original setting
Remove the obstruction, then restart it
Set a proper temperature, see the methods of application
Close the doors and windows
Set a proper temperature
Remove the obstruction
Switch on the power
Replace the battery
Clean the air filter
Replace the fuse
Wait
Methods of resolution
The normal protections of the air-conditioner
1.Compressor protection The compressor don t restart after stop operating in 3 minutes.
the heating operation just starts frost dissolving operation operating under low temperature
Cold wind prevention (heat pump type )
Non-air-conditioner trouble
In the heating mode, the indoor unit won t send wind or operate in low wind ,if the heat exchanger of indoor unit has not reached the stipulated temperature in the following three states, so as to prevent the cold wind.
,
Frost dissolving operation (hot pump type )
The fan of the indoor and outdoor unit will stop under frost dissolving operation. The time for frost dissolving varies in range of 4 to 10 minutes according to the out-
door temperature and the frost condition.
It is normal phenomenon that there may be steam coming out from the outdoor unit
during the frost dissolving operation.
When the temperature is low and humidity is high outdoors, the heat exchanger of outdoor unit may frost, which may decrease the heating capacity. In such case, the air­conditioner will stop the heating operation and convert to automatic frost dissolving, and then resume heating after the frost dissolving finishes.
,
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 10
R
Page 27
When the outdoor temperature falls, the heating capacity decrease accordingly because the heat absorbed from outdoors decreases (See the figure at the right).At the same time, the temperature difference between indoors and outdoors is enlarged, so that the heating load increase accordingly. If the air-conditioner can not reach a satisfactory effect, it is recommended that other heating devices be used together.
2.White steam comes out from the indoor unit During the cooling operation ,under high relative humidity indoors, white steam may come out due to the high humidity and temperature difference of air inlet and outlet. The air-conditioner convert to heating operation after the frost dissolving, the moisture due to frost dissolving is discharged in form of steam.
3.High noise during operation
4.Dust is blown out from the indoor unit
5.The peculiar smell emanates from indoor unit
6.Cooling /Heating (not for cold wind type) operation converts to only wind mode.
7.If you select the cooling operation in a relatively damp environment (relative humidity
is higher than 80%),dew may be formed over the surface of indoor unit and drop. In such a case, please adjust the vertical wind vanes to its maximum ventilation position(i.e.,close to the position normal to the horizontal direction)and choose to improve the dew phenomenon.
high
When the air-conditioner uses the first time after being left unused for a long time, the dust inside the indoor unit will be blown out.
The s ell which absorbed from room, furniture, clothing or cigarette emanates during the air-conditioner is operating.
m
When the indoor unit reaches the stip lated temperature, the air-conditioner will stop the operation of compressor and convert to only wind mode. The compressor will restart cooling or heating after the room temperature rise or drop to a certain degree.
u
When the compressor is operating or just stops operation, fizzle may be heard because of the refrigerant flow or stop flowing. After the air-conditioner operates or stops for a while, crackle from the naturel expansion and contraction of the plastic components may be heard because of temperature variation. When the air-conditioner is energized for the first time, sound from friction may be heard because of the rotating of wind wave.
8.Heating operation (heat pump type ) During the heating operation ,the heat pump of
air-conditioner operates with the principle of absorbing heat outdoor and release heat indoor.
Heating capacity
High
Low
High
Low
Outdoor temperature
11
9.The power cable should be H05VV-F. The connecting cable should be H07RF.
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 11
R
Page 28
2.Use vacuum cleaners or water to clean the air filter, then dry it in a dark and cool place.
3.Insert the upside of air filter into the machine until being entirely fixed, close the front panel and tighten it.
After the air-conditioner is left unused for a long period ,check the inlet and outlet of indoor and outdoor unit for any possible blockage, if any, please clean it. Before the air-conditioner will be left unused for a long period, please make the following preparation.
For the purpose of safety, please turn off the air-conditioner and cut off the power supply before cleaning.
If the air filter is cover by dust, he cooling effect will be undermined. Please regularly clean the air filter.
1.Raise up the front panel of indoor unit until it suddenly stop; then raise up the protruded part of air filter and pull it out downwards.
Don t use dedusting products by chemicals or place close to the machine.
3.The panel of indoor machine may be taken off. Dry it after cleaning with dry cloth.
2.If the indoor unit is very dirty, please wipe with wet cloth dipped by cold water.
Don t use harsh chemicals or abrasive cleaners on any part of the unit.
1.Wipe the indoor unit with dry cloth .
Cleaning the indoor unit
Cleaning air filter
Maintenance
Warning:
Cleaning
Note :
Front panel
Air filter
1.Select the circulation operation mode,make the air-conditioner run for a long time
to dry.
2.when stop operation, Cut off the power supply
4.The inner components of the outdoor unit should be regularly check and clean.
3.Take out the battery in the remote controller.
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 12
R
Page 29
Installation
The installation of air-conditioner should meet Installation Instruction . The machine must be installed correctly by professional technicians according to the
Guide of customer
Installation position
Items of attention
The customer should have a qualified power supply coincident with the tag of the air conditioner, its voltage should be in the range of 90-110% of its rated voltage.
The power supply circuit should have leakage protector and air switch of which the capacity should be more than 1.5 times of the maximum current.
Must use special circuit and efficient grounding socket matching with the plug of air­conditioner.
The wiring must be done by qualified electrician according to the electrical safety requirements.
The air-conditioner must be well grou ded, the switch of the main power of air­conditioner must be reliably grounded.
n
Don t pull the power supply wire, which must be changed by specialists.
Fix the machine firmly, otherwise it will produce noise and vibration.
Install the outdoor unit where it will not disturb your neighbor.
See Installation Instruction
Installation Instruction .
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
Page 13
R
Page 30
15998003545 T01022
WWW.PREMIERMUNDO.COMWWW.PREMIERMUNDO.COM
R
Loading...