C534, C534i Self Powered Elliptical Fitness Crosstrainerl
Procedure 6.3 - Upper Display does not Illuminate (C534,
only)
1. Because thisisself powered unit, the display will not illuminate until it is used or the option
external power supply
is
equipped. If the optional external power supply is equipped, the
display should be constantly illuminated. If the optional external power supply
is
not
equipped, the unit must be used at a stride rate of 40 strides per minute or higher for the
display to illuminate.
2. If the optional external power supply is not equipped, skip to step 5.
3.
Disconnect the optional external power supply from the EFX and measure between the
inner and outer sleeves of the power supply's output jack with a DC voltmeter. You should
measure approximately 18 VDC.
4.
If the voltage measured in step 3 was significantly low, replace the optional external power
supply. If the voltage measured
in
step 3 was 0 Vdc, disconnect external power supply from
its AC outlet and measure the voltage at the AC outlet. If the AC outlet voltageisnormal
replace the optional external power supply. If the AC outlet voltage
is
significantly low or 0
Vdc, the AC system must be inspected by an electrician .
5.
Troubleshoot the generator per Procedure 6.5 (C534) or Procedure 6.6 (C534i).
6.
If the generator was found to be good, the problem will be in either the lower PCA, upper
PCA orthe upper to lower PCA interconnect cables.
Warning
Because this is a self powered unit, it will either be necessary to either equip the unit with the
optional external power supply or have an assistant pedal on the unit while voltage
measurements are being taken. Because ofthe danger of working on the unit while it
isinmotion
using the optional external power supply is strongly recommended.
7.
Remove the rear cover and disconnect the interconnect cable from the J2 connector of the
lower PCA.
8.
The following voltage reading must be taken while the unit isinmotion. Extreme care must
be taken to keep meter leads, hands, etc. clear of all moving parts. Using a DC voltmeter,
measure the voltage between pins 1 and 8 of the J2 connector or between TP20 and TP6.
See Diagram 6.3. The voltage measured should be approximately 8.5 Vdc. If the voltage
is
significantly low, replace the lower PCA.
9.
Reconnect the interconnect cable to the J2 connector of the lower PCA and repeat the
voltage measurementinstep8.The voltage measured should be approximately 8.5 Vdc. If
the voltage
is
significantly low, the problem is in the upper PCA or the upper to lower PCA
interconnect cables.
Page 23