Prastel FT25BS2-R User Manual

FT25BS2-R
1 2 3 4 5 6
alimentazione
(TX)
B
frequenza
ITALIANO
ISFT25BS2REU_08_13.doc
1. Descrizione generale
2. Caratteristiche tecniche principali
Alimentazione TX 2 Batterie Litio Cloruro di Tionile 3V6 2,7Ah Alimentazione RX 12 ÷ 24 V AC/DC
Consumo TX < 500 µA Consumo RX 30 mA Contenitore ABS Dimensioni/peso 110 x 50 x 25 mm 200g Grado d'isolamento IP 45 Lunghezza d’onda infrarosso 950 nm Portata contatto relè 0,5 A @ 24 V AC/DC Portata fascio infrarosso 25 m nominali (8 m in esterno ) Temperatura di funzionamento -20 +55° C Tempo d’intervento con interruzione raggio fotocellula Tempo d’intervento con azionamento bordo sensibile collegato in morsettiera Tempo di ripristino < 150 ms
In alternativa 12 ÷ 24 V AC/DC
< 40 ms < 60 ms
3. Morsettiera ricevitore
1 2 3 4 5 6
+V
- V N.C./N.A. C LOW BAT LOW BAT
Alimentazione 12 - 24 V AC/DC
Contatto relè normalmente aperto o chiuso a seconda jumper di selezione NA/NC
Contatto normalmente aperto di batteria scarica
4. Morsettiera trasmettitore
1
+12 ÷ +24 V AC/DC
2
0 V
3
EDGE
4
EDGE
5
EDGE 8K2
6
EDGE 8K2
Alimentazione 12 - 24 V AC/DC Comune alimentazione Morsetto per contatto pulito costa sensibile (se non usato ponticellare) Morsetto per costa resistiva 8K2 (se non usato NON ponticellare)
5. Installazione
- Fissare le fotocellule servendosi delle dime di foratura in dotazione (fig. 2)
- Eseguire i collegamenti come indicato nei paragrafi precedenti e selezionare l’alimentazione del trasmettitore tramite l’apposito jumper (J1, Fig. 1B):
POSIZIONE A: alimentazione esterna 12-24 V AC/DC POSIZIONE B: alimentazione a batteria
- Scegliere la stessa frequenza di funzionamento sul ricevitore e sul trasmettitore tramite gli appositi jumper (J2, fig 1A e 1B): Frequenza 1: Jumper disinserito Frequenza 2: Jumper inserito
- Collegare all’apposita morsettiera (morsetti 3 e 4, Fig. 1B) il contatto della costa o della sicurezza esterna al trasmettitore.
Se questa opzione non viene utilizzata, ponticellare i morsetti 3 e 4.
- Collegare all’apposita morsettiera (morsetti 5 e 6, Fig. 1B) il contatto della costa resistiva 8K2 esterna al trasmettitore. Se
questa opzione non viene utilizzata, NON ponticellare i morsetti 5 e 6.
- Scegliere sul ricevitore la logica del contatto di uscita NA o NC mediante il jumper J3
- Posizionare sul trasmettitore e sul ricevitore la sonda nella posizione tra le tre possibili più favorevole all’allineamento.
- Effettuare l’allineamento del fascio al ricevitore agendo sulle
- Misurare con un voltmetro il valore di tensione presente sui
- Verificare che l’interruzione del fascio infrarosso generi
6. Segnalazione batteria scarica
La situazione di batteria scarica viene segnalata per via ottica dal trasmettitore al ricevitore. Il ricevitore chiude il contatto pulito LOW BAT disponibile in morsettiera e attiva una segnalazione intermittente tramite il buzzer. L’indicazione di batteria scarica viene fornita una settimana prima del totale esaurimento della batteria. Una volta sostituite le batterie, spegnere e riaccendere il ricevitore per disattivare il contatto LOWBAT e il buzzer. Questo avverrà comunque automaticamente entro 15 minuti.
apposite viti di fissaggio “A” (fig. 2) fornite in dotazione sia sul ricevitore che sul trasmettitore.
test-point del ricevitore (fig. 2). Tale valore varia in funzione di vari parametri, tra cui la distanza tra le fotocellule. Più alto è il valore di tensione sul test-point migliore è l’allineamento. La misura ottimale deve comunque essere compresa tra 0,5 e 0,6 VDC.
l’apertura del contatto normalmente chiuso del relè sul ricevitore e l’accensione del LED rosso.
1 2 3 4 5 6
A
J2: Selezione frequenza
J3: Selezione contatto NA/NC
Fig. 1A (RX)
J1: Selezione
J2: Selezione
Fig. 1B
FT25BS2-R
selection
(TX)
B
Selection
Selection
contact selection
ENGLISH
ISFT25BS2REU_08_13.doc
1. General Description
The FT25BS2-R photocells are fitted with a transmitter that can be powered by two 3V6 2.7Ah lithium Thionyl chloride batteries or with an external 12/24V AC/DC power supply, selectable with a jumper. The optical unit (emitter diode + lens) of the transmitter and of the receiver can be oriented in three different directions so it can be adapted to different installation situations. The photocell has two terminals for the connection of a free contact of an external safety device (safety edge) and two terminals for the connection of a resistive edge. The photocell is particularly suited for use on sliding gates, mounted on the mobile part it can be connected to a wire or resistive safety edge, without having to lay cables or use re-wind cables. The battery life-span is more than 15 months. In compliance with European reference standards (Electromagnetic Compatibility 89/336/CEE).
2. Main technical features
Power supply Transmitter 2 3V6 2.7Ah Lithium Thionyl chloride batteries Power supply Receiver 12 -24 V AC/DC
Consumption Transmitter < 500 µA Consumption Receiver 30 mA Container ABS Dimensions/weight 110 x 50 x 25 mm 200g Protection rating IP 45 Infra-red wavelength 950 nm Relay contact range 0.5 A @ 24 V AC/DC Infra-red beam range 25 m nominal (8 m outdoor ) Operating temperature -20 +55° C Intervention time with triggering of photocell beam Intervention time with triggering of safety edge connected to terminal strip Reset time < 150 ms
Alternatively 12 - 24 V AC/DC
< 40 ms < 60 ms
1 2 3 4 5 6
J2: Frequency
J3: NO/NC
Fig. 1A
3. Receiver terminal strip
1
+V
2
- V
3
N.C./N.O.
4
C
5
LOW BAT
6
LOW BAT
Power supply 12 - 24 V AC/DC
Relay contact normally open or closed depending on NO/NC selection jumper
Flat battery Normally open contact
A
J1: Power supply
J2: Frequency
4. Transmitter terminal strip
1
+12 - +24 V AC/DC
2
0 V
3
EDGE
4
EDGE
5
EDGE 8K2
6
EDGE 8K2
Power supply 12 - 24 V AC/DC Common power supply Terminal for safety edge free contact (jump if not used) Terminal for 8K2 resistive edge (DON’T jump if not used)
1 2 3 4 5 6
Fig. 1B
5. Installation
- Fix the photocell using the supplied drilling template (fig. 2)
- Make connections as indicated in the previous paragraphs and
select the transmitter power supply with the specific jumper (J1, Fig. 1B):
POSITION A: external power supply 12-24 V AC/DC POSITION B: battery powered
- Select the same operating frequency on the receiver and on the transmitter with the specific jumpers (J2, fig 1A & 1B): Frequency 1: Jumper disabled Frequency 2: Jumper enabled
- Connect to the specific terminal strip (terminals 3 & 4, Fig. 1B) the safety edge or external safety device contact to the transmitter. If this option is not used, jump terminals 3 and
4.
- Connect to the specific terminal strip (terminals 5 & 6, Fig. 1B) the contacts of the 8K2 resistive edge external to the transmitter. If this option is not used, do NOT jump
terminals 5 and 6.
- Select on the receiver the logic of the NO or NC output contact with jumper J3.
- Position on the transmitter the probe in the position from the three possibilities most suitable to the alignment.
- Align the beam to the receiver by adjusting the specific fixing screws “A” (fig. 2) supplied, both on the receiver and the transmitter.
- With a voltmeter, measure the tension value on the receiver test-point. (Fig. 2). This value varies according to various parameters, among which the distance between the photocells. The higher the tension value on the test-point the better is the alignment. The ideal measure should be between 0.5 and 0.6 VDC.
- Check that the interruption of the infra-red beam causes the opening of the normally closed contact of the relay on the receiver and the lighting up of the red LED.
6. Flat battery signal
The flat battery situation is signalled optically by the transmitter to the receiver. The receiver closes the free LOW BAT contact available in the terminal strip and activates an intermittent buzzer. The flat battery indication is given one week before the battery is completely flat. Once the batteries have been replaced, switch the receiver OFF then back ON to deactivate the LOWBAT contact and the buzzer. However, this will happen automatically after 15 minutes.
(RX.)
FT25BS2-R
1 2 3 4 5 6
alimentation
(TX)
B
fréquence
contact NO/NF
FRANÇAIS
ISFT25BS2REU_08_13.doc
1. Description générale
Les photocellules FT25BS2-R sont dotées d'un émetteur qui peut être alimenté par deux batteries de 3V6 2,7Ah au lithium-chlorure de thionyle ou par alimentation extérieure 12/24V AC/DC, sélectionnable par cavalier. Le bloc optique (diode émettrice + lentille) de l'émetteur et du récepteur peut être orienté dans trois directions pour s'adapter aux différentes situations d'installation. La photocellule dispose de deux bornes pour la liaison d’un contact sec d'une sécurité extérieure (barre palpeuse) et de deux bornes pour la liaison d'une barre palpeuse résistive. La photocellule est particulièrement indiquée pour être utilisée sur des portails coulissants (installée sur la partie mobile), permettant de relier une barre palpeuse à fil ou résistif sans devoir tirer des câbles ou utiliser des câbles enroulables. La durée des batteries est supérieure à 15 mois. Conforme aux standards européens (Compatibilité Electromagnétique 89/336/CEE).
2. Caractéristiques techniques principales
Alimentation TX 2 batteries au lithium-chlorure de thionyle 3V6 2,7Ah Alimentation RX 12 ÷ 24 V AC/DC
Consommation TX < 500 µA Consommation RX 30 mA Boîtier ABS Dimensions/poids 110 x 50 x 25 mm 200g Degré d'isolation IP 45 Longueur d'onde infrarouge 950 nm Calibre du contact relais 0,5 A @ 24 V AC/DC Portée du faisceau infrarouge 25 m nominaux (8 m en extérieur) Température de fonctionnement -20 +55° C Temps de déclenchement avec coupure rayon photocellule Temps de déclenchement avec déclenchement du bord sensible relié au bornier Temps de réarmement < 150 ms
En variante 12 ÷ 24 V AC/DC
< 40 ms < 60 ms
3. Bornier du récepteur
1 2 3 4 5 6
+V
- V N.F./N.O. C LOW BAT LOW BAT
Alimentation 12 - 24 V AC/DC
Contact relais normalement ouvert ou fermé selon cavalier de sélection NO/NF
Contact normalement ouvert de batterie déchargée
4. Bornier de l'émetteur
1
+12 ÷ +24 V AC/DC
2
0 V
3
EDGE
4
EDGE
5
EDGE 8K2
6
EDGE 8K2
Alimentation 12 - 24 V AC/DC Commun alimentation Borne pour le contact sec de la barre palpeuse (ponter si elle n'est pas utilisée) Borne pour la barre palpeuse résistive 8K2 (NE PAS ponter si elle n'est pas utilisée)
5. Installation
- Fixer les photocellules à l'aide des gabarits de perçage fournis (fig. 2)
- Effectuer les connexions comme indiqué dans les paragraphes précédents et sélectionner l'alimentation de l'émetteur au moyen du cavalier prévu à cet effet (J1, Fig. 1B):
POSITION A: alimentation extérieure 12-24 V AC/DC POSITION B: alimentation par batterie
- Choisir la même fréquence de fonctionnement sur le récepteur et sur l'émetteur à l'aide des cavaliers prévus à cet effet (J2, fig. 1A et 1B): Fréquence 1: cavalier désactivé Fréquence 2: cavalier activé
- Relier au bornier prévu à cet effet (bornes 3 et 4, Fig. 1B) le contact de la barre palpeuse ou de la sécurité extérieure à l'émetteur. Si cette option n'est pas utilisée, ponter les
bornes 3 et 4.
- Relier au bornier prévu à cet effet (bornes 5 et 6, Fig. 1B) le contact de la barre palpeuse résistive 8K2 extérieure à l'émetteur. Si cette option n'est pas utilisée, NE PAS ponter
les bornes 5 et 6.
- Choisir sur le récepteur la logique du contact de sortie NO ou NF au moyen du cavalier J3
- Positionner la sonde sur l'émetteur en choisissant, parmi les trois positions possibles, celle qui convient le mieux à l'alignement.
1 2 3 4 5 6
- Effectuer l'alignement du faisceau avec le récepteur en agissant sur les vis de fixation “A” (fig. 2) fournies, aussi bien sur le récepteur que sur l'émetteur.
- Mesurer avec un voltmètre la valeur de la tension présente sur les points de test du récepteur (fig. 2). Cette valeur varie en fonction de différents paramètres, dont la distance entre les photocellules. Plus la valeur de la tension sur le point de test est élevée, meilleur est l'alignement. La mesure optimale doit toujours être comprise entre 0,5 et 0,6 VDC.
- Vérifier que la coupure du faisceau infrarouge entraîne l'ouverture du contact normalement fermé du relais sur le récepteur et l'allumage de la LED rouge.
6. Signalisation de batterie déchargée
La situation de batterie déchargée est signalée, par voie optique, de l'émetteur au récepteur. Le récepteur ferme le contact sec LOW BAT disponible au bornier et active un signal intermittent par buzzer. L’indication de batterie déchargée est fournie une semaine avant l'épuisement total de la batterie. Une fois les batteries remplacées, éteindre et rallumer le récepteur pour désactiver le contact LOWBAT et le buzzer. En tout cas, ceci se produira automatiquement dans les 15 minutes.
J2: Sélection
J3: Sélection
Fig. 1A
(RX)
J1: Sélection
Fig. 1B