Line Interactive UPS
PowerWalker VI 450 IEC
PowerWalker VI 650 IEC
PowerWalker VI 850 IEC
PowerWalker VI 1200 IEC
PowerWalker VI 2200 IEC
Quick Start Guide
EN
![](/html/f2/f264/f264e064e95a246564d2fd5b95d788a8c45ddd75041569fb6be13389a78ee669/bg2.png)
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerWalker VI
450 IEC / 650 IEC / 850 IEC / 1200 IEC / 2200 IEC that should be followed during installation and
maintenance of the UPS and batteries.
• This product is specially designed for PCs and it is not recommended for use in any medical
equipment, life-supporting system and other specific important equipment.
• Do not plug household appliances such as hair dryers, microwave ovens or vacuum cleaners to UPS.
• Do not attach a power strip or surge suppressor to the UPS.
• Do not plug the UPS into its own output.
• Connection to any other type of receptable other than two-pole, three-wire grounded receptacle
may result in shock hazard as well as violate local electrical codes.
• To reduce risk of overheating the UPS, do not cover the UPS´ cooling vents.
• This unit intended for installation in a controlled environment (temperature controlled, indoor area
free of conductive contaminants). Avoid installing the UPS in locations where there is standing or
running water or excessive humidity and do not use it in any of the following environments:
o Any area with combustible gas, corrosive substance or heavy dust.
o Any area with extraordinarily high or low temperature (above 40˚C or below 0˚C) and
humidity of more than 90%.
o Any area exposed to direct sunshine or near any heating apparatus.
o Any area with serious vibrations.
o Outdoor.
• The utility power outlet shall be near the equipment and easily accessible. In the event of an
emergency, press OFF button and disconnect the power cord from the AC power supply to properly
disable the UPS.
• The internal short circuiting of the UPS will lead to dangers such as electric shock or fire; therefore
do not allow liquids or any foreign object to enter the UPS. No water containers (such as a water
glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid such
dangers as electric shock.
• Please do not use the UPS in excess of the rated load capacity.
• Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
• Risk of electric shock, do not attempt to disassemble the unit. No user serviceable parts inside. Refer
servicing to qualified service personnel.
• If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the
utility power to UPS, switch “ON”), once a month for 24 hours to avoid a full battery discharge.
• In case smoke is found coming out from the device, please cut off the power supply quickly and
contact the distributor.
![](/html/f2/f264/f264e064e95a246564d2fd5b95d788a8c45ddd75041569fb6be13389a78ee669/bg3.png)
• The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such
dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is
required, please contact the distributor.
• Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
• A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries:
o Remove watches, rings, or other metal objects from the hand.
o Use tools with insulated handles and wear rubber gloves and boots.
o Do not lay tools or metal parts on top of batteries.
o Disconnect charging source prior connecting or disconnecting batteries terminals.
• When replacing batteries, replace with the same type and number of the sealed lead-acid batteries.
• The maximum ambient temperature rating is 40°C.
• Do not dispose of battery or batteries in a fire. The battery may explode.
• Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
• Icon Φ on the rating label stands for phase symbol.
• This pluggable type A equipment with battery already installed by the supplier is operator installable
and may be operated by laymen.
• During the installation of this equipment it should be assured that the sum of the leakage currents
of the UPS and the connected loads does not exceed 3.5mA.
• Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole of the battery when maintenance or service work
inside the UPS is necessary.
• In the event that there is fire occurring in the vicinity, please use dry-power extinguishers. The use of
liquid extinguishers may give rise to the danger of electric shock.
This product complies with the safety and environmental regulations in EU.
If the time arises to throw away your product, please recycle all the components possible. Batteries and
rechargeable batteries are not to be disposed in your domestic waste! Please recycle them at your local
recycling point. Together we can help to protect the environment.