IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS – This manual contains important instructions for models PowerWalker VI 450 IEC / 650 IEC / 850 IEC / 1200 IEC / 2200 IEC that should be followed during installation and maintenance of the UPS and batteries.
This product is specially designed for PCs and it is not recommended for use in any medical
equipment, life-supporting system and other specific important equipment.
Do not plug household appliances such as hair dryers, microwave ovens or vacuum cleaners to UPS.
Do not attach a power strip or surge suppressor to the UPS.
Do not plug the UPS into its own output.
Connection to any other type of receptable other than two-pole, three-wire grounded receptacle
may result in shock hazard as well as violate local electrical codes.
To reduce risk of overheating the UPS, do not cover the UPS´ cooling vents.
This unit intended for installation in a controlled environment (temperature controlled, indoor area
free of conductive contaminants). Avoid installing the UPS in locations where there is standing or
running water or excessive humidity and do not use it in any of the following environments:
o Any area with combustible gas, corrosive substance or heavy dust. o Any area with extraordinarily high or low temperature (above 40˚C or below 0˚C) and
humidity of more than 90%.
o Any area exposed to direct sunshine or near any heating apparatus. o Any area with serious vibrations. o Outdoor.
The utility power outlet shall be near the equipment and easily accessible. In the event of an
emergency, press OFF button and disconnect the power cord from the AC power supply to properly
disable the UPS.
The internal short circuiting of the UPS will lead to dangers such as electric shock or fire; therefore
do not allow liquids or any foreign object to enter the UPS. No water containers (such as a water
glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid such
dangers as electric shock.
Please do not use the UPS in excess of the rated load capacity.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Risk of electric shock, do not attempt to disassemble the unit. No user serviceable parts inside. Refer
servicing to qualified service personnel.
If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting the
utility power to UPS, switch “ON”), once a month for 24 hours to avoid a full battery discharge.
In case smoke is found coming out from the device, please cut off the power supply quickly and
contact the distributor.
EN
The UPS contains one/two large-capacity batteries. So the shell shall not be opened, otherwise such
dangers as electric shock will be caused. If any internal overhaul or replacement of the battery is
required, please contact the distributor.
Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries
and the required precautions. Keep unauthorized personnel away from batteries.
A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries:
o Remove watches, rings, or other metal objects from the hand. o Use tools with insulated handles and wear rubber gloves and boots. o Do not lay tools or metal parts on top of batteries. o Disconnect charging source prior connecting or disconnecting batteries terminals.
When replacing batteries, replace with the same type and number of the sealed lead-acid batteries.
The maximum ambient temperature rating is 40°C.
Do not dispose of battery or batteries in a fire. The battery may explode.
Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
Icon Φ on the rating label stands for phase symbol.
This pluggable type A equipment with battery already installed by the supplier is operator installable
and may be operated by laymen.
During the installation of this equipment it should be assured that the sum of the leakage currents
of the UPS and the connected loads does not exceed 3.5mA.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should be
therefore disconnected in the plus and minus pole of the battery when maintenance or service work
inside the UPS is necessary.
In the event that there is fire occurring in the vicinity, please use dry-power extinguishers. The use of
liquid extinguishers may give rise to the danger of electric shock.
This product complies with the safety and environmental regulations in EU.
If the time arises to throw away your product, please recycle all the components possible. Batteries and rechargeable batteries are not to be disposed in your domestic waste! Please recycle them at your local recycling point. Together we can help to protect the environment.
EN
EN
1. Introduction
PowerWalker VI series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which
is designed to protect your personal computer or sensitive electronic equipments from all forms of power interference, including complete power failures. It is equipped with many features that allow any attached equipment to operate longer and more reliability.
2. Description of Features
Easy to use and install utilized microprocessor control to maximize the reliability and efficiency
Equipped with built-in boost and buck AVR function
DC Cold start function
Green Power Function for energy saving
Auto restart while AC recovery.
Provides AC Overload protection
RJ11/RJ45 (in/out) LAN/Modem/Phone line protection
3. Package Contents
You should have received the following items inside of package:
UPS Unit USB Cable AC Input Power Cord
(for VI 1200/2200 only)
Software CD Quick Start Guide Service Guide
EN
EN
4. Product Overview
Front Panel:
VI 450 / 650 / 850 IEC VI 1200 / 2200 IEC
EN
USB port
 
LED Indicators
AC mode: green lightning Battery mode: green flashing
Power ON/OFF
Back Panel:
AC input
4*IEC outlet
 
RJ11/RJ45 LAN/Modem/phone line
protection
VI 450 / 650 / 850 IEC VI 1200 IEC VI 2200 IEC
Power ON/OFF
LED Indicators
Normal: green lightning
 
Battery mode: yellow flashing AC mode: green lightning
Fault mode: red lightning
AC input
6*IEC outlet
 
USB port
RJ11/RJ45 LAN/Modem/phone line protection
EN
5. Installation and Initial Startup
Before installation, please inspect the unit. Be sure that nothing is damaged
I: Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow around the unit,
and is free from excessive dust, corrosive fumes and conductive contaminants. Please place the UPS away
from other units at least 20 cm to avoid interference. Do NOT operate the UPS where the temperature
exceeds 0-40° C and the humidity is over 0-90 % RH.
II: Connect to Utility and Charge
Plug in the AC input cord to the 2-pole, 3-wire grounded wall outlet. For the best results, we suggest charging
the battery at least 6 hours with no load (no electrical devices such as computers, monitors, rtc.) connected
before initial use. The unit charges its battery while connecting to the utility.
.
EN
III: Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the power switch of UPS
unit, and devices connected to the UPS will be protected by UPS unit.
Do not attach a power strip or surge suppressor to the UPS.
IV: Connect LAN cable, Modem or Phone line for Surge Protection
Connect for example a single modem or phone line into surge-protected “IN” outlet on the back panel of the
UPS unit. Connect from “OUT” outlet to the computer with another phone line cable.
V: Connect USB Cable
To monitor the UPS status, such as unattended UPS shutdown and start-up, by using bundled software,
please connect the UPS and PC with USB cable included.
EN
NEVER connect a laser printer or scanner to the
UPS unit, because in-rush current generated by
motor’s devices may cause the damage of the unit.
VI: Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again the power switch.
Sounding every 10 seconds
Battery
Mode
Sounding every 1 second
Battery Low
Sounding every 0.5 seconds
Overload
continuous sounding
Faulty
EN
6. Functions & Operation
I: DC Start Function
DC Start Function enables UPS to be started up when AC utility power is not available and battery is fully charged. Just simply press the power switch to turn on the UPS.
II: Green Power Function
These series are equipped with Green Power Function for saving power and protecting battery. The feature of deep discharge protection is adoped on battery mode. If no load is connected to the UPS, it will automatically shut down after 5 minutes for energy saving while running on battery mode. The UPS will restart while AC recovery.
III: AVR (Automatic Voltage Regulation)
If the quality of the incoming mains is poor, the AVR boosts a low incoming voltage or reduces a high one. The load receives a voltage within the normal range.
IV: Auto restart while AC recovery
V: Audio Indicator
Audible Alarm Situation
7. Software Installation on your PC
Connected by USB to a PC or notebook, the Software enables communication between the UPS and the
computer. The UPS software monitors the status of the UPS, shuts down the system before the UPS is
exhausted and can remotely observe the UPS via the Network (enabling users to manage their system more
effectively). Upon AC failure or UPS battery low, UPS takes all necessary actions without intervention from the
system administrator. In addition to automatic file saving and system shut-down functions, it can also send
warning messages via pager, e-mail etc.
Use the bundled CD and follow the on-screen instructions to install the software WinPower.
Enter the following serial No. to install software: 511C1-01220-0100-478DF2A
After the software is successfully installed, the communication with UPS has been established and a
green icon will appear in the system tray.
Double-click the icon to use the monitor software (as above).
You can schedule UPS shutdown/start-up and monitor UPS status through PC.
Detail instructions please refer to the e-manual in the software.
Check www.powerwalker.com/winpower.html from time to time to get the latest
version of monitoring software.
Symptom
Possible Cause
Remedy
No LED display on the
1. Battery weak.
1. Charge battery up
to 8 hours.
2. Battery defect.
2. Replace with the same type of
battery.
3. Power switch is not pressed.
3. Press the power switch again.
Alarm buzzer beeps
continuously when AC
Overload of the UPS.
Verify that the load matches the
UPS
When power failure,
1. Overload of the UPS.
1. Remove some non
-
critical load.
2. Battery voltage is too low.
2. Charge battery 8 hours or more.
3. Battery defect due to high temperat
ure
operation environment, or improper
3. Replace with the same type of battery.
Mains normal but LED is
Power cord is loose.
Reconnect the power cord properly.
EN
8. Maintenance
I. General
The UPS is virtually maintenance free: take care of proper environmental conditions and keep air inlets­outlets free of dust.
II. Fuses
If the AC input fuse is defect, be sure it is replaced by a compatible fuse from the same make and type.
Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools.
III. Batteries
Read all safety rules before replacing the battery.
When replacing the batteries, use batteries with exactly same specifications.
9. Trouble Shooting
EN
front panel.
supply is normal.
back-up time is shorten.
operation to battery.
flashing.
If any abnormal situations occur that are not listed above, please call service people immediately.
capability specified in the specs.
Model
CAPACITY
12
00VA / 600W
2200VA /
1100W
BATTERY
Type & Number
12V / 7Ah x 2
12V / 9Ah x 2
Charging Time
6h to 90% capacity
Protection
Overload,
discharge and overcharge protection
Backup Time (est.
100W)
PHYSICAL
LED Indicator
Normal, Battery mode, AC mode, Fault mode
Dimension (DxWxH)
365mm
x 139mm
x 195 mm
EN
10. Specifications
Model Complete Series
VI 450 IEC VI 650 IEC VI 850 IEC VI 1200 IEC VI 2200 IEC
INPUT Voltage 230 VAC Voltage Range 170~280 VAC OUTPUT Voltage 220/230/240 VAC Voltage Regulation +/-10% (Battery mode) Frequency Range 50/60Hz Frequency Regulation ±1Hz (Battery mode) Transfer Time Typical 4-8ms Waveform Modified Sine Wave PROTECTION Full protection Discharge, overcharge and overload protection ENVIRONMENT Humidity 0-90 % RH @ 0° to 40° C (non-condensing) Noise Level Less than 40dB 45dB Software Monitoring Software WinPower (included)
Model CAPACITY 450VA / 240W 650VA / 360W 850VA / 480W BATTERY
Type & Number 12V/4.5Ah x1 12V/ 7Ah x1 12V/9Ah x1 Charging Time 6 hours recover to 90% capacity Backup Time (est. 100W) 8 min 16 min 20 min PHYSICAL LED Indicator Green LED (AC Mode, Backup Mode) Outlet and Connector 4x IEC outlets, USB port, RJ11/RJ45 Surge Protection Dimension (DxWxH) 279mm x 100mm x 143mm WEIGHT Net weight 3.5kg 4.4kg 5.0kg
VI 450 IEC
VI 1200 IEC VI 2200 IEC
VI 650 IEC VI 850 IEC
Outlet and Connector 6x IEC outlets, USB port, RJ11/RJ45 Surge Protection
WEIGHT Net weight 8.6kg 10.2kg
30 min 50 min