Thanks for buying this UPS product. Please follow the instructions in the product manual and
if applicable the software installation manual, to have the maximum use of your product.
Installing the software:
If you product comes with software you will find a CD Rom in the box containing the
software. Please follow the instructions when installing the software. You can download the
software, manual and short reference manual at the following site: http://powerwalker.com
Problem solving:
Please check the chapter in your manual (hardware and software) on problem solving. If this
not solves your problem please contact our support at http://support.powerwalker.com or
simply send e-mail to service@powerwalker.com
Service and Maintenance:
If the product requires service or maintenance, no matter it is under or out of warranty
period always contact your reseller for the procedures. If outside the warranty period we
advise you to contact your reseller as well. In any case always make sure that service or
maintenance on the product is performed by a qualified technician.
1
1. IMPORTANT SAFETY INSTRUCTIONS
This product is designed for home and office usage and it is not recommended for any medical
equipment, life-supporting system and other specific important equipment.
Do not plug appliances such as hair dryers, microwave ovens or vacuum cleaners to UPS.
Do not plug the UPS into its own output.
Connection to any other type of receptable other than two-pole, three-wire grounded receptacle
may result in shock hazard as well as violate local electrical codes.
To reduce risk of overheating the UPS, do not cover the UPS´ cooling vents.
This unit intended for installation in a controlled environment, only indoor. Do not install the UPS in
locations where there is standing or running water or excessive humidity or any of the following
environments:
o Any area with combustible gas, corrosive substance or heavy dust.
o Any area with extraordinarily high or low temperature (above 40˚C or below 0˚C) and humidity of
more than 90%.
o Any area exposed to direct sunshine or near any heating apparatus.
o Any area with serious vibrations.
In the event of an emergency or smoke coming out of the unit, press OFF button and disconnect
the power cord from the AC power supply to properly disable the UPS.
The internal short circuiting of the UPS will lead to dangers such as electric shock or fire; therefore
do not allow liquids or any foreign object to enter the UPS. No water containers (such as a water
glass) or any other liquid-containing vessels shall be placed on the top of the UPS so as to avoid
such dangers as electric shock.
Please do not use the UPS in excess of the rated load capacity.
Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
Risk of electric shock, do not attempt to disassemble the unit. No user serviceable parts inside.
Refer servicing to qualified service personnel.
If UPS is to be stored for a long time, it is recommended to recharge the batteries (by connecting
the utility power to UPS, switch “ON”), once a month for 24 hours to avoid a full battery discharge.
Servicing (replacement) of batteries should be performed or supervised by personnel
knowledgeable of batteries and the required precautions. Keep unauthorized personnel away
from batteries.
A battery can present a risk of electrical shock and high short circuit current. The following
precautions should be observed when working on batteries:
o Remove watches, rings, or other metal objects from the hand.
2
o Use tools with insulated handles and wear rubber gloves and boots.
o Do not lay tools or metal parts on top of batteries.
o Disconnect charging source prior connecting or disconnecting batteries terminals.
When replacing batteries, replace with the same type and number of the sealed lead-acid
batteries.
o Never short circuit batteries. When working with batteries, remove watches, rings and other
metal objects, and only use insulated tools.
o The battery must be replaced exclusively by qualified personnel (risk of shock). Prohibit users
from their own battery replacement. Contact your reseller if need.
The maximum ambient temperature rating is 40°C.
Do not dispose of battery or batteries in a fire. The battery may explode.
Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and
eyes. It may be toxic.
Icon Φ on the rating label stands for phase symbol.
This is pluggable equipment with pre-installed batteries and may be operated by laymen.
During the installation of this equipment it should be assured that the sum of the leakage currents
of the UPS and the connected loads does not exceed 3.5mA.
Attention, hazardous through electric shock. Also with disconnection of this unit from the mains,
hazardous voltage still may be accessible through supply from battery. The battery supply should
be therefore disconnected in the plus and minus pole of the battery when maintenance or service
work inside the UPS is necessary.
In the event that there is fire occurring in the vicinity, please use dry-power extinguishers. The use
of liquid extinguishers may give rise to the danger of electric shock.
This product complies with the safety and environmental regulations in EU.
If the time arises to throw away your product, please recycle all the components possible. Batteries
and rechargeable batteries are not to be disposed in your domestic waste! Please recycle them at
your local recycling point. Together we can help to protect the environment.
3
2. Introduction
For IEC socket product
For Schuko/FR socket product
- UPS Unit x 1
- Startup manual x 1
- Warranty card x 1
- USB cable x 1
- IEC output cable x 1
- UPS Unit x 1
- Startup manual x 1
- Warranty card x 1
- USB cable x 1
VI GX series is an intelligent and compact line interactive UPS (Uninterruptable Power Supply)
which is designed to protect your personal computer or sensitive electronic equipments from all
forms of power interference, including complete power failures. It is equipped with many features
that allow any attached equipment to operate longer and more reliability.
3. Description of Features
Easy to use and install utilized microprocessor control to maximize the reliability and efficiency
Equipped with built-in boost and buck AVR function
DC Cold start function
Auto restart while AC recovery.
Provides AC Overload protection
RJ11/RJ45 (in/out) LAN/Modem line protection
Provides DC 5.1V 2.0Amp Max USB charger
4. Package Contents
You should have received the following items inside of package:
4
5. Product Overview
400VA~850VA
1200VA & 1600VA & 2200VA
When LCD starts to work, it will
display all information for 3
seconds.
When in normal mode, it will
display as below.
When in AVR mode, it will
display as below. And the mark
will flicker every
1second.
When in battery mode, it will
display as below. And the mark
will flicker every
1second.
Note: If I/P-V<40V,input
voltage will display “000”
When in off charging mode, it
will display as below.
Note: the output voltage always
is displayed as “000” in off
charging mode.
When in fault mode, it will
display as below. “FAULT”
character and “0” character
only.
Indicate the percentage of UPS load capacity which is being used by
the protected equipment. Each LCD level bar indicates a 25% of the
total UPS output capacity.
Indicate the amount of battery volume remaining. Each battery
volume level bar indicates a 20% of total battery volume
5.1 Front Panel
4.1.1 Display
4.1.2 Load capacity level display:
4.1.3 Battery capacity definition:
4.1.4 When over load , the mark will flicker every 1second.
4.1.5 When battery low , the mark will flicker every 1second.
5
5.2 Back Panel:
650VA/850VA IEC Rear Panel
650VA/ 850VA Schuko Rear Panel
650VA/ 850VA FR Rear Panel
1200VA IEC Rear Panel
1200VA Schuko Rear Panel
1200VA FR Rear Panel
1600VA/2200VA IEC Rear Panel
1600VA/2200VA Schuko Rear Panel
6
1600VA/2200VA FR Rear Panel
Before installation, please inspect the unit. The unit is prepared without any falling
objects or physical dmanage.
Do not attach a power strip or surge suppressor to the UPS.
6. Installation and Initial Startup
I: Placement & Storage Conditions
Install the UPS in a protected area that is free of excessive dust and has adequate air flow
around the unit, and is free from excessive dust, corrosive fumes and conductive
contaminants. Please place the UPS away from other units at least 20 cm to avoid
interference. Do NOT operate the UPS where the temperature exceeds 0-40° C and the
humidity is over 0-90 % RH.
II: Connect to Utility and Charge
Plug in the AC input cord to the 2-pole, 3-wire grounded wall outlet. For the best results, we
suggest charging the battery at least 6 hours with no load (no electrical devices such as computers,
monitors, rtc.) connected before initial use. The unit charges its battery while connecting to the
utility.
III: Connect the Loads
Plug in the loads to output receptacles on the rear panel of the UPS. Simply turn on the
power switch of UPS unit, and devices connected to the UPS will be protected by UPS unit.
7
IV: Connect LAN cable, Modem line for Surge Protection
NEVER connect a laser printer or scanner to the UPS unit,
because in-rush current generated by motor’s devices may
cause the damage of the unit.
Audible Alarm
Situation
Sounding every 10 seconds
Battery Mode
Sounding every 1 second
Battery Low
Sounding every 0.5 seconds
Overload
continuous sounding
Faulty
InputAVROutput 2
DC/AC
Battery
Charger
Output 1
(1200/1600/2200)
EN
Connect for example a single modem line into surge-protected outlet on the back panel of the UPS
unit. Connect from another outlet to the computer with another line cable.
V: Connect USB Cable
To monitor the UPS status, such as unattended UPS shutdown and start-up, by using
bundled software, please connect the UPS and PC with USB cable included.
VI: Turn On/Off the Unit
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again
the power switch.
VII: Following figure shows the basic internal circuit configuration of the UPS
7. Audio Indicator
8. Software Installation on your PC
Connected by USB to a PC or notebook, the Software enables communication between the UPS and
the computer. The UPS software monitors the status of the UPS, shuts down the system before
the UPS is exhausted and can remotely observe the UPS via the Network (enabling users to
manage their system more effectively). Upon AC failure or UPS battery low, UPS takes all necessary
actions without intervention from the system administrator. In addition to automatic file saving
and system shut-down functions, it can also send warning messages via pager, e-mail etc.
8
Use the bundled CD and follow the on-screen instructions to install the software WinPower.
Check http://winpower.powerwalker.com to get the latest version of monitoring software.
on charging status
on discharging status
Enter the following serial No. to install software: 511C1-01220-0100-478DF2A
After the software is successfully installed, the communication with UPS has been established
and a green icon will appear in the system tray.
Double-click the icon to use the monitor software (as above).
You can schedule UPS shutdown/start-up and monitor UPS status through PC.
Detail instructions please refer to the e-manual in the software.
9. Smart Battery function
When UPS connect windows PC with USB cable, it will show a battery icon located in the
system tray, near the clock. You can get some basic information (ex. Charging/Discharging,
battery remaining capacity) by clicking the battery icon.
You can set to Sleep/Hibernate/Shutdown OS or do nothing when it reached Battery Low
Level or Battery Critical Level (with OS without Winpower).
9
In order to have more detail information and advantage functions by software; Winpower
Symptom
Possible Cause
Remedy
No LED display on the
front panel.
1. Battery weak.
1. Charge battery up to 8 hours.
2. Battery defect.
2. Replace with the same type of battery.
3. Power switch is not pressed.
3. Press the power switch again.
Alarm buzzer beeps
continuously when AC
supply is normal.
Overload of the UPS.
Verify that the load matches the UPS
capability specified in the specs.
When power failure, backup time is shorten.
1. Overload of the UPS.
1. Remove some non-critical load.
2. Battery voltage is too low.
2. Charge battery 8 hours or more.
3. Battery defect due to high
temperature operation environment,
or improper operation to battery.
3. Replace with the same type of
battery.
Mains normal but LED is
flashing.
Power cord is loose.
Reconnect the power cord properly.
Prohibit user replace battery by oneself. Please contact your reseller if need.
software is available for further application.
10. Trouble Shooting
If any abnormal situations occur that are not listed above, Please stop using the unit and contact
your reseller for advice.
When replacing the batteries, use batteries with exactly same specifications.
The battery must be replaced exclusively by qualified personnel (risk of shock).
10
11. Specifications
Model
VI 650 GX
VI 850 GX
VI 1200 GX
VI 1600 GX
VI 2200 GX
CAPACITY
650VA/360W
850VA/480W
1200VA/720W
1600VA/960W
2200VA/1200W
INPUT
Voltage
230 VAC
Voltage Range
170~280 VAC
OUTPUT
Voltage
230 VAC
Voltage Regulation
± 10% (Battery mode)
Frequency Range
50/60Hz
Frequency Regulation
±1Hz (Battery mode)
Transfer Time
Typical 2-6ms
Typical 4-8ms
Waveform
Modified Sine Wave
PROTECTION
Full protection
Discharge, overcharge and overload protection
ENVIRONMENT
Humidity
0-90 % RH @ 0° to 40° C (non-condensing)
Noise Level
Less than 40dB
Less than 45dB
Software
Monitoring Software
WinPower (included) / HID
BATTERY
Type & Number
12V/7Ah x 1
12V/9Ah x 1
12V/7Ah x 2
12V/9Ah x 2
12V/9Ah x 2
Charging Time
4 hours recover to 90% capacity
Backup Time (est. 100W)
17 min
22 min
45 min
55 min
55 min
PHYSICAL
LCD Indicator
LCD display
Outlet
4 x IEC outlets(1 bypass)
2 x FR outlets
2 x Schuko outlets
6 x IEC outlets(2 bypass)
4 x FR outlets
4 x Schuko outlets
USB charger
DC 5.1V/2.0Amp Max.
Connector
USB communication port,
USB charge port,
RJ45 Surge Protection
Dimension (DxWxH)
290mm x 100mm x 143mm
364mm x 139mm x 195 mm
WEIGHT
Net weight
4.4kg
5.2kg
8.9kg
10.4kg
10.4kg
11