Powersolve TRA1 User Manual

DC-DC Converters
TRA1 Series, 1 Watt
www.powersolve.co.uk
Features
Semi-regulated output
Industry standard pin out
High efficiency up to 86%
Single & dual output models
I/O isolation 1000VDC
Operating temperature range -40°C to +85°C
Electrical Specification
Short Circuit Protection limited 0.5 sec. Operating Temperature Range -40°C to +85°C (no derating) I/O Isolation test voltage 1000VDC Casing plastic (UL94V-0 rated)
Output Voltage and Current Ratings
MODEL INPUT OUTPUT OUTPUT RIPPLE & LINE LOAD EFF.
TRA1-0511 5VDC 200mA 30mV pk-pk max. 1.2% 5% 86% TRA1-0519 9VDC 110mA 30mV pk-pk max. 1.2% 5% 86% TRA1-0512 12VDC 84mA 30mV pk-pk max. 1.2% 5% 86% TRA1-0513 5VDC ±10% 15VDC 67mA 30mV pk-pk max. 1.2% 5% 86% TRA1-0521 ±5VDC ±100mA 30mV pk-pk max. 1.2% 5% 86% TRA1-0522 ±12VDC ±42mA 30mV pk-pk max. 1.2% 5% 86% TRA1-0523 ±15VDC ±34mA 30mV pk-pk max. 1.2% 5% 86% TRA1-1211 5VDC 200mA 30mV pk-pk max. 1.2% 4% 86% TRA1-1219 9VDC 110mA 30mV pk-pk max. 1.2% 4% 86% TRA1-1212 12VDC 84mA 30mV pk-pk max. 1.2% 4% 86% TRA1-1213 12VDC ±10% 15VDC 67mA 30mV pk-pk max. 1.2% 4% 86% TRA1-1221 ±5VDC ±100mA 30mV pk-pk max. 1.2% 4% 86% TRA1-1222 ±12VDC ±42mA 30mV pk-pk max. 1.2% 4% 86% TRA1-1223 ±15VDC ±34mA 30mV pk-pk max. 1.2% 4% 86% TRA1-2411 5VDC 200mA 30mV pk-pk max. 1.2% 3% 86% TRA1-2419 9VDC 110mA 30mV pk-pk max. 1.2% 3% 86% TRA1-2412 12VDC 84mA 30mV pk-pk max. 1.2% 3% 86% TRA1-2413 24VDC ±10% 15VDC 67mA 30mV pk-pk max. 1.2% 3% 86% TRA1-2421 ±5VDC ±100mA 30mV pk-pk max. 1.2% 3% 86% TRA1-2422 ±12VDC ±42mA 30mV pk-pk max. 1.2% 3% 86% TRA1-2423 ±15VDC ±34mA 30mV pk-pk max. 1.2% 3% 86%
VOLTAGE VOLTAGE CURRENT NOISE REG. REG. (typ.)
Mechanical and Connection Details
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Pin Single Output Dual Output
1 +Vin (Vcc) +Vin (Vcc) 2 -Vin (GND) -Vin (GND) 4 -Vout -Vout 5 No pin Common 6 +Vout +Vout
Dimensions in mm (inches)
Loading...