T
U
nit 8A
Arnhem Road
Newbury. RG14 5RU
el: +44 (0) 1635 521858
Fax: +44 (0) 1635 523771
www.powersolve.co.uk
ISO AMP Card - Four chan nel an a log iso la tion amplifier Safety isolation
Features
Features
• Selectable 0-5 V and 0-10 V signal levels
• Isolated programming and monitoring of U, I and status signals
• Prevents problems with earth loops and CM-voltages
• Factory installed
Specifications
• Programming and monitoring offset : +/- 60 µV typical
• Full scale error : 0.1% calibrated
• Non-linearity : 0.01% typical, TC = 65ppm/°C
• Common mode rejection : 80 db @ 50 Hz
Block diagram

Specifications
Connections ISO AMP CARD
CON1 - internal circuitry To plug the card inside the power supply (20P header connector).
CON2 - external connections To connect the card to a programming source (15P female D-connector).
Analog inputs / outputs: CV, CC programming and CV, CC monitoring
Offset ± 60 µV typical, ± 180 µV max.
Full scale error 0.1 % calibrated.
Non-linearity 0.01 % typical, 0.05 % max.
Temperature coefficient – 65 ppm typical.
Common mode rejection 80 dB @ 50 Hz.
Voltage range CON1
CON2
Input impedance CON1
CON2
Output impedance CON1
CON2
Reference voltage 5.114 V ± 15 mV (Ro = 10 Ω / max. 4 mA), TC = 20 ppm/°C
Auxiliary supply voltage 11.4 - 12.7 V / Ri = 470 Ω
Digital status outputs: CC, LIM, OT, ACF and DCF
Output voltage CON2 + 5 V / max. 2 mA
Output impedance CON2 5 Ω
0 - 5 V
0 - 5 V or 0 - 10 V selectable
200 kΩ
200 kΩ for 5 V input, 400 kΩ for 10 V input
100 Ω / max. 4 mA
1 Ω / max. 4 mA
Digital input: Remote ShutDown.
Input voltage CON2 3 - 15 V
Input impedance CON2 1.8 kΩ
General
Capacitance CON2 - Case 3.2 nF
Operating temperature – 20 to + 50 °C
Storage temperature – 40 to + 85 °C
Humidity max. 95% RH, non condensing, up to 40 °C
max. 75% RH, non condensing, up to 50 °C
Isolation voltages CON2 - CON1 1000 VDC Reinforced isolation acc. EN60950-1 / EN61010-1
Isolation test voltage
Minimum creepage distance
Specifications are measured at an ambient temperature of 25 °C ± 5 °C unless otherwise noted.
Note1: The four analog channels are factory-calibrated within 0.1 % for 5 V input and output voltages.
Selecting a 10 V input and/or output without re-calibrating can introduce an extra full scale error of 0.1 %.
Offset, full scale error, non-linearity and temperature coefficient have to be added to the specifications of the power supply.
Note2: Reinforced isolation is available only when the ISO AMP is built inside a Delta Elektronika power supply.
CON2 - Case 1000 VDC Basic isolation
4250 VDC
10 mm
Ordering information
Models Order Code :
SM 800 P249
SM 1500 P218
SM 3000 P145
SM 6000 P154