Powersolve HSEUreg10001 User Manual

HSEUreg10001 DIN Rail
Made in Germany 1000W Programmable DC Power Supply
Short Specification:
Metal housing
90% efficiency
-25°C...+60°C full output power
Natural convection
Galvanic insulated
Continuous short circuit protected
Overload (OVP) & low voltage protected
Soft start & auto-recovery
Hold up time >30ms
No base load required
Available outputs: 0…18V, 0…30V, 0…50V, 0...90V, 0...130V, 0...180V, 0...240V
Analogue interface 0-10Vdc/0-20mA/4-20mA(option)
External shutdown
Sense control
Series & parallel operation
DIN Rail 35mm & wall mount
Screw terminals AWG20...AWG6
High reliability, shock & vibration proof
24 hours burn in test
EMI/EMS EN61000-6-2,3, EN55022 class B
IEC(EN)60950-1 in accordance to cUL60950/16950
In accordance with IEC60950-1
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uk sales@powersolve.co.uk
p.1/5 03.12B
AC Input
90..132Vac / 184..265Vac , 47…63Hz , 250…375Vdc
AC Input Rating
115Vac<
16.8
A 230Vac
<9.0A
250Vdc<
5.0A 375Vdc<3.3
A
Rated DC Voltage
0...15V
0...30V
0...50V
0...90V
0...130V
0...180V
0...240V
Overvoltage Protection
18Vdc
35Vdc
59Vdc
105Vdc
150Vdc
210Vdc
280Vdc
Rated DC Current
50A 33A 20A 11.2A
7.8A 5.6A 4.2A
Power Boost
-
25...+60°C <1min.
55A 36.3A
22A 12.3A
8.6A 6.1A 4.6A
Max. DC Current +70°C
37.5A
24.8A
15A 8.4A 5.9A 4.2A 3.2A
Ripple Peak 230Vac 20MHz
50mVpp
50mVpp
100mVpp
200mVpp
250mVpp
300mVpp
400mVpp
Sense function
Compensation 2V per lead load
, protec
tive electrical separation
60Vdc
Remote Shutdown
protective electrical separation
60Vdc
Analogue Interface
see table, 4
-
20mA available option,
protective electrical separation
60Vdc
, work.res.=500
Pmax
1000W
continuous
Derating
+60°C...+70°C 2.5%/
°C
Accurancy
< ± 1.5%
Latency Interface
t.b.d.
Load regulation
< ± 0.2%
0-100%
Response
Load Change
<1ms
10-100%, 100
-
10%
Base Load None
Efficiency
230Vac
90% typical
Short Circuit Protection
Continuous
Idling
-
proof
Yes
Temperature Control
Yes
, thermal shutdown with auto recovery
(+70°C, metering distance 10mm)
Hold Up Time
> 3
0ms
230Vac
Inrush Current
< 162A
(230Vac)
Softstart
100ms typical
Cooling
Controlled fan (manufacturer EBM
-
Papst)
Ambient Operating Temp
. - 25°C…+70°C
Ambient Storage Temp
. - 40°C…+85°C
Environment
Humidity 95% non
-
condensing
@
25°C, climate class
. 3k3, pollution rate II
EMI EN55022 class B
EMS EN61000
-6-
2,3
Safety
cUL60950, EN60950
-1
Safety class 1(A)
VDE0805, VDE0100
Isolation
Path > 8mm
Input / Output
Galvanic insulated
Meantime By Failure (MTBF)
400000h
(IEC61709)
Dimensions (HxWxD)
130x200x114,5
mm
Weight
3000g
Screw
Terminals
(In/Out)
AWG20...AWG6
, 0.
5...16mm²
(76A @ 40°C)
Interface
Progamme [V
] 0...10Vdc
Progamme [A]
0...20mA
Progamme [A
] 4...20mA
¹)
Shutdown
external
Sensing
2V lead load
¹) option
Ordering Information:
Output Type (DIN-Rail standard) Part Number Option Part Number
0...18V HSEUreg10001.18T 304.1053.001CA Backplate kit
0...30V HSEUreg10001.30T 304.1053.002CA
0...50V HSEUreg10001.50T 304.1053.003CA ADTW201
0...90V HSEUreg10001.90T 304.1053.004CA
0...130V HSEUreg10001.130T 304.1053.005CA 4..20mA option
0...180V HSEUreg10001.180T 304.1053.006CA
0...240V HSEUreg10001.240T 304.1053.007CA Screw terminal plug 3520037 2pol. LS5,08 (package=10pcs)
(wallmount)
DC-repeater
220.1002.001CA
304.1090.001CA
Ad 420 to the type number example: HSEUreg04801.15T420
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uk sales@powersolve.co.uk
p.2/5 03.12B
Series Connection (fig.1)
Technical Information ADTW201 external DC
-
Repeater
F
1) Active Transient Filter 2) Rectifier 3) Inrush Current Limiter 4) Load Capacitor 5) Power Transformer 6) Storage Choke
Technical Description
The HSEUreg-Series is a programmable switch mode power supply. Engineered and manufactured in by CAMTEC in Germany, it is designed for challenging applications like railway, drives, test-stands and machine-building. The HSEUreg provides a low Ripple-Noise, good Load­Regulation and high efficiency >90% (typ. @ 230Vac). High-end long life capacitors guarantee Hold-up-Time and extended lifetime of the power supply. Our HSEUreg-design starts complex loads easily. The internal control manages illegal operating conditions to prevent your system from failures. All HSEUreg power supplies are idling-proof and short circuit protected. Supply units of the same type and output voltage feature parallel or series operation. The HSEUreg also features active high input transients with suppressor diodes, X2-capacitors and varistors. The design rules set value on extended interference immunity and safety. The PSU is engineered in accordance to EN60950-1 and EMC-compatibility to EN55022 class B.
Series Connection (fig.1) Parallel Connection (fig.2)
1 = transient filter 2 = rectifier 3 = inrush limiter NTC 4 = load capacitor 5 = transformer 6 = storage throttle
Input (Ie) 0…20mA, 4…20mA (max. 50mA) Voltage drop (Uw) Uw>1.5V (Ie=20mA) Max. apparent ohmic resistance (Ra) 500R @ Ie=20mA Input Impedance (R) R=Ra+Uw/IE Barrier Frequency (Fa) Fa=5kHz (-3dB) with Ra=500R @ Ie=20mA Output 1:1 Ripple / Noise >0,5% with 20mA and Ra=500R Linear Failure >0,03% / 100R Transient oscillation current 35uA Latency 150us 0..20mA, Ra=500R, 10…90% Isolation Voltage Input/output 500V Operation Temperature 0…50°C Temperature Drift Approx. 15ppm/K Weight 21g Ordering Information Part No: 304.1090.001CA
C O N V E R T E
To increase output voltage equal HSEUreg can be connected in series. The control I/O should be galvanic insulated in the series mode. If not the minus main output is connected to the control I/O. Use our external option Isolating Transformer ADTW201 being validated with the HSEUreg. Be aware of safety norms if your target output voltage exceeds safety voltage.
Parallel Connection (fig.2)
To increase the output power up to 3 HSEUreg can be parallel connected. Advise using busbars to connect HSEUreg in parallel. Always use identical length and identical cross sections to the busbar.
ADTW201 Isolating Transformer (option)
The isolating transformer is used to galvanic isolate impressed current. The device is self powered. The input to output ratio is 1:1.
P I D
C O N T R O L
C T
I L T E R
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uk sales@powersolve.co.uk
p.3/5 03.12B
Coating
Option
Test Time A B C D
Type Test
Factory Test
Field Test
Terminal Connects:
wire
Mechanics & Installation of the
HSEUreg
Backplate Option
We offer the USEUIreg-series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic resin. It is procured with a robotics varnishing machine. Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0
Ordering Information: ad extension C to the complete type number: HSEUreg10001.180TC or HSEUreg10001T420C
Type test and factory tests are
60s 2500Vac 3000Vac 500Vdc 500Vdc 5s 2000Vac 2000Vac 500Vdc 500Vdc 2s 2000Vac 2000Vac 500Vdc 500Vdc
a) Use approriate test equipment which apply the voltage with a slow ramp b) Connect L1 and N together, as well as all output poles c) Use only AC test-voltages with 50/60Hz. The output voltages is floating and has
no ohmic reference to ground.
d) If testing output voltages are 60Vdc remain to security directives.
Use only isolated screw drivers to adjust output voltages.
AC Main Input
GND common N - wire L -
Stable metal/aluminium housing IP20. To allow adequate convection, a free air space of 50mm (top/bottom) and 5mm (sidewalls) is required; for active devices 15mm space from the sidewalls. For free air convection it is necessary to install the HSEUreg horizontal. You can use the DIN-Rail installation (equiped standard) with our patented 35mm DIN-Rail bracket according to EN60275. It is easy to mount/dismount while snaping it onto the 35mm DIN-Rail - any tools necessary. A wallmount backplate (option) is availble, too
DC Mains Outputs DC + voltage DC + voltage DC - voltage DC - voltage
conducted by the manufacturer.
Do not repeat the test in field.
Field test rules:
Inputs/Outputs
Ureg = programmable voltage input Ureg = programmable current input SD = shut down input Sense = Sensing (compensation: 2V)
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uk sales@powersolve.co.uk
p.4/5 03.12B
Safety Instructions:
ready to hand.The HSEUreg must be installed by specialist staff only.
Installation:
1.) The HSEUreg is designed for systems fulfilling the safety norms of dangerous voltages/energy and fire prevention
2.) Installation is restricted to specialists only, make sure that the AC wire system is free of voltage
3.) Opening the HSEUreg, making any modifications to it, dismounting any screws from it, operating the HSEUreg out of specification and/or using it in appropriate area will unevitably result in loosing manufactureres guarantee; we decline taking any responsibility for risk of demages caused to someones health or to any installed system.
4.) Attention: The HSEUreg has an internal input fuse. It is necessary to wire an automatic circuit braker to the line. We suggest to use a 16A-type with B-characteristic. It is verboten to operate the HSEUreg without protective earth wired. It essential to install a line switch before the HSEUreg.
Please read all warnings and advices carefully before installing or operating the HSEUreg. Retain this operation manual always
Warnings
Disregard these warnings can cause fire, electic shock, serious accident and death.
:
1. Never operate the HSEUreg without Protective Earth Conductor
2. Before connecting the HSEUreg to the AC wire system make all wires free of voltage and assure accidently switch on
3. Allow neat and professionel cabeling
4. Never open nor try to repair the HSEUreg by yourself. Inside are dangerous voltages that can cause electric shock hazard.
5. Avoid metal pieces or other conductive material to fall into the HSEUreg
6. Do not operate the HSEUreg under damp or wet conditions
7.
It is verboten to operate the HSEUreg under Ex conditions or in Ex-Area
All parameters base on 15 minutes run-in @ full load / 25°C / 230Vac 50/60Hz, as otherwise stated.
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uk sales@powersolve.co.uk
p.5/5 03.12B
Loading...