AC Input
90..132Vac / 184..265Vac , 47…63Hz , 250…375Vdc
AC Input Rating
115Vac<
16.8
A 230Vac
<9.0A
250Vdc<
5.0A 375Vdc<3.3
A
Rated DC Voltage
0...15V
0...30V
0...50V
0...90V
0...130V
0...180V
0...240V
Overvoltage Protection
18Vdc
35Vdc
59Vdc
105Vdc
150Vdc
210Vdc
280Vdc
Rated DC Current
50A 33A 20A 11.2A
7.8A 5.6A 4.2A
Power Boost
-
25...+60°C <1min.
55A 36.3A
22A 12.3A
8.6A 6.1A 4.6A
Max. DC Current +70°C
37.5A
24.8A
15A 8.4A 5.9A 4.2A 3.2A
Ripple Peak 230Vac 20MHz
50mVpp
50mVpp
100mVpp
200mVpp
250mVpp
300mVpp
400mVpp
Sense function
Compensation 2V per lead load
, protec
tive electrical separation
≤
60Vdc
Remote Shutdown
protective electrical separation
≤60Vdc
Analogue Interface
see table, 4
-
20mA available option,
protective electrical separation
≤60Vdc
, work.res.=500Ω
Pmax
1000W
continuous
Derating
+60°C...+70°C 2.5%/
°C
Accurancy
< ± 1.5%
Latency Interface
t.b.d.
Load regulation
< ± 0.2%
0-100%
Response
Load Change
<1ms
10-100%, 100
-
10%
Base Load None
Efficiency
230Vac
90% typical
Short Circuit Protection
Continuous
Idling
-
proof
Yes
Temperature Control
Yes
, thermal shutdown with auto recovery
(+70°C, metering distance 10mm)
Hold Up Time
> 3
0ms
230Vac
Inrush Current
< 162A
(230Vac)
Softstart
100ms typical
Cooling
Controlled fan (manufacturer EBM
-
Papst)
Ambient Operating Temp
. - 25°C…+70°C
Ambient Storage Temp
. - 40°C…+85°C
Environment
Humidity 95% non
-
condensing
@
25°C, climate class
. 3k3, pollution rate II
EMI EN55022 class B
EMS EN61000
-6-
2,3
Safety
cUL60950, EN60950
-1
Safety class 1(A)
VDE0805, VDE0100
Isolation
Path > 8mm
Input / Output
Galvanic insulated
Meantime By Failure (MTBF)
400000h
(IEC61709)
Dimensions (HxWxD)
130x200x114,5
mm
Weight
3000g
Screw
Terminals
(In/Out)
AWG20...AWG6
, 0.
5...16mm²
(76A @ 40°C)
Interface
Progamme [V
] 0...10Vdc
Progamme [A]
0...20mA
Progamme [A
] 4...20mA
¹)
Shutdown
external
Sensing
2V lead load
¹) option
Ordering Information:
Output Type (DIN-Rail standard) Part Number Option Part Number
Ad 420 to the type number example:
HSEUreg04801.15T420
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
The HSEUreg-Series is a programmable switch mode power supply. Engineered and manufactured in by CAMTEC in Germany, it is designed
for challenging applications like railway, drives, test-stands and machine-building. The HSEUreg provides a low Ripple-Noise, good LoadRegulation and high efficiency >90% (typ. @ 230Vac). High-end long life capacitors guarantee Hold-up-Time and extended lifetime of the
power supply. Our HSEUreg-design starts complex loads easily. The internal control manages illegal operating conditions to prevent your
system from failures. All HSEUreg power supplies are idling-proof and short circuit protected. Supply units of the same type and output
voltage feature parallel or series operation.
The HSEUreg also features active high input transients with suppressor diodes, X2-capacitors and varistors. The design rules set value on
extended interference immunity and safety. The PSU is engineered in accordance to EN60950-1 and EMC-compatibility to EN55022 class B.
Series Connection (fig.1) Parallel Connection (fig.2)
Input (Ie) 0…20mA, 4…20mA (max. 50mA)
Voltage drop (Uw) Uw>1.5V (Ie=20mA)
Max. apparent ohmic resistance (Ra) 500R @ Ie=20mA
Input Impedance (R) R=Ra+Uw/IE
Barrier Frequency (Fa) Fa=5kHz (-3dB) with Ra=500R @ Ie=20mA
Output 1:1
Ripple / Noise >0,5% with 20mA and Ra=500R
Linear Failure >0,03% / 100R
Transient oscillation current 35uA
Latency 150us 0..20mA, Ra=500R, 10…90%
Isolation Voltage Input/output 500V
Operation Temperature 0…50°C
Temperature Drift Approx. 15ppm/K
Weight 21g
Ordering Information Part No: 304.1090.001CA
C
O
N
V
E
R
T
E
To increase output voltage equal HSEUreg can be
connected in series. The control I/O should be galvanic
insulated in the series mode. If not the minus main output
is connected to the control I/O. Use our external option
Isolating Transformer ADTW201 being validated with the
HSEUreg. Be aware of safety norms if your target output
voltage exceeds safety voltage.
Parallel Connection (fig.2)
To increase the output power up to 3 HSEUreg can be
parallel connected. Advise using busbars to connect
HSEUreg in parallel. Always use identical length and
identical cross sections to the busbar.
ADTW201 Isolating Transformer (option)
The isolating transformer is used to galvanic isolate
impressed current. The device is self powered. The input
to output ratio is 1:1.
P
I
D
C
O
N
T
R
O
L
C
T
I
L
T
E
R
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uksales@powersolve.co.uk
p.3/5 03.12B
Coating
Option
Test Time A B C D
Type Test
Factory Test
Field Test
Terminal Connects:
wire
Mechanics & Installation of the
HSEUreg
Backplate Option
We offer the USEUIreg-series with optional coating. It is to be used in e.g. dusty, dirty, high humidity, or in awaiting quick temperature
changes. Short circuit and corrosion at print board lines and at solder points can be prevented. The coat itself is a transparent acrylic
resin. It is procured with a robotics varnishing machine.
Peters SL 1306 N-FLZ (transparent) IEC60216-1 2001, IPC-CC-830B, UL listed as permanent coating FileNo.: E80315 , UL94V-0
Ordering Information: ad extension C to the complete type number: HSEUreg10001.180TC or HSEUreg10001T420C
a) Use approriate test equipment which apply the voltage with a slow ramp
b) Connect L1 and N together, as well as all output poles
c) Use only AC test-voltages with 50/60Hz. The output voltages is floating and has
no ohmic reference to ground.
d) If testing output voltages are ≥60Vdc remain to security directives.
Use only isolated screw drivers to adjust output voltages.
AC Main Input
GND common
N - wire
L -
Stable metal/aluminium housing IP20. To allow adequate convection, a free air space of 50mm (top/bottom) and 5mm (sidewalls) is
required; for active devices 15mm space from the sidewalls. For free air convection it is necessary to install the HSEUreg horizontal. You
can use the DIN-Rail installation (equiped standard) with our patented 35mm DIN-Rail bracket according to EN60275. It is easy to
mount/dismount while snaping it onto the 35mm DIN-Rail - any tools necessary. A wallmount backplate (option) is availble, too
DC Mains Outputs
DC + voltage
DC + voltage
DC - voltage
DC - voltage
conducted by the manufacturer.
Do not repeat the test in field.
Field test rules:
Inputs/Outputs
Ureg = programmable voltage input
Ureg = programmable current input
SD = shut down input
Sense = Sensing (compensation: 2V)
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uksales@powersolve.co.uk
p.4/5 03.12B
Safety Instructions:
ready to hand.The HSEUreg must be installed by specialist staff only.
Installation:
1.) The HSEUreg is designed for systems fulfilling the safety norms of
dangerous voltages/energy and fire prevention
2.) Installation is restricted to specialists only, make sure that the AC
wire system is free of voltage
3.) Opening the HSEUreg, making any modifications to it, dismounting
any screws from it, operating the HSEUreg out of specification
and/or using it in appropriate area will unevitably result in loosing
manufactureres guarantee; we decline taking any responsibility for
risk of demages caused to someones health or to any installed
system.
4.) Attention: The HSEUreg has an internal input fuse. It is necessary
to wire an automatic circuit braker to the line. We suggest to use a
16A-type with B-characteristic. It is verboten to operate the
HSEUreg without protective earth wired. It essential to install a line
switch before the HSEUreg.
Please read all warnings and advices carefully before installing or operating the HSEUreg. Retain this operation manual always
Warnings
Disregard these warnings can cause fire, electic shock, serious
accident and death.
:
1. Never operate the HSEUreg without Protective Earth
Conductor
2. Before connecting the HSEUreg to the AC wire system
make all wires free of voltage and assure accidently
switch on
3. Allow neat and professionel cabeling
4. Never open nor try to repair the HSEUreg by yourself.
Inside are dangerous voltages that can cause electric
shock hazard.
5. Avoid metal pieces or other conductive material to fall into
the HSEUreg
6. Do not operate the HSEUreg under damp or wet
conditions
7.
It is verboten to operate the HSEUreg under Ex conditions
or in Ex-Area
All parameters base on 15 minutes run-in @ full load / 25°C / 230Vac 50/60Hz, as otherwise stated.
Powersolve Electronics Ltd., Unit 8A Arnhem Road, Newbury RG14 5RU, United Kingdom
Tel 0044 (0)1635 521858 Fax 0044 (0)1635 523771
(Subject to alterations. This product is not designed to be used in applications such as life support systems wherein a failure or malfunction could result in injury or death)
www.powersolve.co.uksales@powersolve.co.uk
p.5/5 03.12B
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.