ISO AMP - External module - Four channel analog isolation amplifier
Features
Selectable 0-5 V and 0-10 V signal levels
Isolated programming and monitoring of U, I and status signals
Prevents problems with earth loops and CM-voltages
Isolated logic inputs and outputs
Pin compatible with D15 connector on Delta elektronika power supplies
Specifications
Programming and monitoring offset : +/- 60 µV typical
Full scale error : 0.1% calibrated
Non-linearity : 0.01% typical, TC = 65ppm/°C
Common mode rejection : 80 db @ 50 Hz
Dimensions
Di men sions of the ex ter nal ISO AMP MODULE.
Specifications
Analog inputs / outputs: CV, CC programming and CV, CC monitoring
Offset ± 60 µV typical, ± 180 µV max.
Full scale error 0.1 % calibrated.
Non-linearity 0.01 % typical, 0.05 % max.
Temperature coefficient – 65 ppm typical.
Common mode rejection 80 dB @ 50 Hz.
Voltage range: connector 'to power supply':
connector 'to prog. source':
Input impedance: connector 'to power supply':
connector 'to prog. source':
Output impedance: connector 'to power supply':
connector 'to prog. source':
Reference voltage 5.114 V ± 15 mV (Ro = 10 / max. 4 mA), TC = 20 ppm/°C
Auxiliary supply voltage 11.4 - 12.7 V / Ri = 470
Digital status outputs: CC, LIM, OT, ACF and DCF
Output voltage: connector 'to prog. source': + 5 V / max. 2 mA
Output impedance: connector 'to prog. source': 5
Digital input: Remote ShutDown.
Input voltage: connector 'to prog. source': 3 - 15 V
Input impedance: connector 'to prog. source': 1.8 k
General
Capacitance input / case 3.2 nF
Operating temperature – 20 to + 50 °C
Storage temperature – 40 to + 85 °C
Humidity max. 95% RH, non condensing, up to 40 °C
Isolation voltages Input-Output 1000V Basis isolation
Connections ISO AMP MODULE
Supply voltage 15 - 30 V DC, max 75 mA.
2 pole terminal block To connect the external supply voltage.
15P female D-connector To connect the module to a programming source.
15P male D-connector To connect the module to the power supply.
0 - 5 V 0 - 5 V or 0 - 10 V selectable
200 k 200 k for 5 V input, 400 k for 10 V input
100 / max. 4 mA 1 / max. 4 mA
max. 75% RH, non condensing, up to 50 °C
Input-Case 1000V Basic isolation
The four analog channels are factory-calibrated within 0.1 % for 5 V input and output voltages. Selecting a 10 V input and/or output without re-calibrating can introduce an extra full scale error of 0.1 %. Offset, full scale error, non-linearity and temperature coefficient have to be added to the specifications of the power supply.
Ordering information
Order ISO AMP MODULE for the external module.
The external module can be used in combination with all programmable Delta Elektronika power supplies.
Accessories
The following is supplied with the ISO AMP MODULE:
Rail adapter for 35 mm rail mounting
Wall mounting adapter