powersoft Quattrocanali 4804 DSP+D, Quattrocanali 1204, Quattrocanali 2404, Quattrocanali 2404 DSP+D, Quattrocanali 4804 Quick Manual

Page 1
Keep this manual
for future reference
©2017 Powersoft
Quattrocanali Series
Quattrocanali 4804 Quattrocanali 4804 DSP+D
Quattrocanali 1204 Quattrocanali 1204 DSP+D
QUICK GUIDE
DO000209.02 R8
Page 2
powersoft_Quattrocanali_qguide_en_v0.1
Data are subject to change without notice. For latest update please refer to the English online version available on www.powersoft-audio.com.
Les données sont sujettes à changement sans préavis. Pour la dernière mise à jour, s’il vous plaît se référer à la version anglaise disponible en ligne sur www.powersoft-audio.com.
Esta información está sujeta a cambios sin previo aviso. Para la última actualización por favor reérase a la versión disponible en Ingles en nuestro sitio de internet www.powersoft-audio.com.
I dati sono soggetti a cambiamenti senza preavviso. Per gli aggiornamenti si prega di consultare la versione inglese disponibile online su www.powersoft-audio.com.
数据如有更改,恕不另行通知。 最新更新,请参考在线的英文版本:http://www.powersoft-audio.com
Данные могут быть изменены без предварительного уведомления. Для более детальной информации используйте полное руководство на английском языке. Электронная версия доступна на с айте - http://www.powersoft-audio.com.
Alle Angaben können jederzeit ohne vorherige Ankündigung geändert werden. Den jeweils jüngsten Versionsstand nden Sie als englischsprachige Ausgabe auf www.powersoft-audio.com.
Os dados estão sujeitos a alterações sem aviso prévio. Para obter atualizações, consulte a versão em Inglês disponível online em www.powersoft-audio.com.
Designed in Italy by Powersoft S.p.A. (via E. Conti, 5 - 50018 Scandicci, Firenze) Factory 1: MW.FEP S.p.A. (Via Modena, 68 - 40017 San Giovanni in Persiceto, Bologna - Italy) Factory 2: MW.FEP S.p.A. (Via Mario Stoppani, 23 - 34077 Ronchi dei Legionari, Gorizia - Italy)
Page 3
Quattrocanali Series
Table of Contents
1. Important safety instructions 10
2. Quattrocanali Series 11
2 : 1. Welcome 11
2 : 2. Unpacking & checking for shipping damage 11
2 : 3. Disposal of the packaging material 11
2 : 4. List of image panels 11
3. Installation 12
3 : 1. Lo cation 12
3 : 2. Cooling 12
3 : 3. Cleaning 12
3 : 4. Precautions regarding installation 12
3 : 5. AC mains supply 13
3 : 6. Switch ON/OFF 13
3 : 7. Energy save 13
3 : 8. Breaker save 13
3 : 9. Remote ON/OFF (standby mode) 13
4. Connections 14
4 : 1. Signal gr ounding 14
4 : 2. Analog audio input connections 14
4 : 2.1. Remote level adjustment 14
4 : 3. Digital audio input connections 14
4 : 3.1. Input selection and Backup policy 14
4 : 4. Ethernet connection s 14
4 : 5. Output connections 14
4 : 5.1. H i-Z 70V/100V operati ons 14
4 : 6. Gain selection 15
4 : 7. Lo-Z 2Ω load operation 15
4 : 8. Diagnostics - GPO - Alarms 15
4 : 8.1. Pilot tone monitoring 15
4 : 8.2. Output load monitorin g 15
5. LED chart 16
5 : 1. LED bars: signal metering 16
5 : 2. LED strip: system status 16
5 : 3. Operating mode LEDs 16
6. Control Panel 16
6 : 1. Self check 16
6 : 1.1. Global fault s 17
6 : 1.2. Channel faults 17
7. Networking 17
7 : 1. IP addr essing 17
7 : 1.1. IP Addressing troubl esh oot ing 17
8. Armonía Pro Audio Suite 18
8 : 1. Signal routing and DSP architecture 18
8 : 2. Purposed work flow 18
9. Warranty and assistance 19
9 : 1. Warr ant y 19
9 : 1.1. Return of Goods 19
9 : 1.2. Repair o r replacemen t 19
9 : 1.3. Cost and responsibility of transport 19
9 : 2. Assist ance 19
9 : 2.1. Drop off at a
Powersoft Authorized Service Centre near you 19
9 : 2.1.1. In-Warra nt y repairs : 19
9 : 2.1.2. Out of Warranty Issues 19
9 : 2.2. Shipping the product to
Powersoft S.p.a. for Factory service centre 19
9 : 2.2.1. Shipment from NON-CE countries 20
9 : 2.3. D.O.A Procedure 20
10. Specifications 21
Table of contents | 3
Page 4
A
B
4 | Quattrocanali Series
Page 5
C
D
1. Control panel
2. ON LED and STANDBY LED
3. Armonía callback push button
4. Soft Reset push button
5. Hard Reset push button
6. Self Check
7. Global status LED strip
8. LED panel
9. Channel status LED bars
10. Channel 4 level potentiometer
11. Channel 3 level potentiometer
12. Channel 2 level potentiometer
13. Channel 1 level potentiometer
14. Power push button
15. Port reserved for servicing
A. AC mains connector B. Air vent C. Output connector D. Line input connector E. Remote levels connector F. Remote on/off G. Alarm connector H. Dante™ port (DSP+D version only) I. Ethernet port J. System configuration dip switches K. CH1, CH2 output configuration dip
switches
L. CH3, CH4 output configuration dip
switches
Panels | 5
1 2 3 4 5 6
789101112131415
A B C D E F
H
G
IKL J
Page 6
E
INPUT
OUTPUT (single ended)
F
GPO/ALARM
REMOTE ON | REMOTE OFF
REMOTE LEVEL
Phoenix MC 1,5/12-ST-3,81 1803675 Phoenix PC 5/ 8-STF1-7,62 1777891
INPUT (link channel pairs)*
INPUT (Analog Inputs not in use)
* Quattrocanali 4804 without DSP only Quattrocanali 2404 without DSP only Quattrocanali 1204 without DSP o nly
Phoenix MC 1,5/12-ST-3,81 1803675
Phoenix MC 1,5/12-ST-3,81 1803675
Phoenix MC 1,5/4-ST-3,81 1803594
OUTPUT (bridged)
G
H
I
J
common
common
common
common
6 | Quattrocanali Series
Ch 4
Ch 3
Ch 2
Ch 1
(or Master)
Ch 4
Ch 1
Ch 4
Ch 3
Ch 2
Ch 3
Ch 2
Ch 3
Ch 2
Ch 1
Ch 4
Ch 1
Page 7
L
Name Plug
INPUT Phoenix MC 1,5/12-ST-3,81 1803675
OUTPUT Phoenix PC 5/ 8-STF1-7,62 1777891
GPO/ALARM Phoenix MC 1,5/12-ST-3,81 1803675
REMOTE ON|OFF Phoenix MC 1,5/4-ST-3,81 1803594
AC MAINS IEC C19
K
Bill of connectors
Low-Z High-Z 100V 70V HPF @ 35 Hz HPF @ 70 Hz
1
2
3
4
5
6
7
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
1
2
5
3
6
4
7
ground
mains
Panels | 7
Page 8
M
N
O
1 1
1 RU
1 RU
1 RU
Mounting brackets
Soportes de montaje
Supports de xation
1 1
2 2
2 2
3 3
3 3
4 4
4 4
5
1 2 3 4 5 6 7 8
Color code (TIA/EIA-568-B) Pin
ORANGE / WHITE 1
ORANGE 2
GREEN / WHITE 3
BLUE 4
BLUE / WHITE 5
GREEN 6
BROWN / WHITE 7
BROWN 8
RJ45
8 | Quattrocanali Series
Page 9
English
1
WEEE Directive
EC Declaration Of Conformity
If the time arises to throw away your product, please
recycle all possible component.
This symbol indicates that when the end-user wishes to discard this product, it must be sent to separate collection facilities for recovery and recycling. By separating this product from other household-type waste, the volume of waste sent to incinerators or land-lls will be reduced and natural resources will thus be conserved.
The Waste Electrical and Electronic Equipment Directive (WEEE Directive) aims to minimise the impact of electrical and electronic goods on the environment. Powersoft S.p.A. comply with the Directive 2012/19/EU of the European Parliament on waste electrical nance the cost of treatment and recovery of electronic equipment (WEEE) in order to reduce the amount of WEEE that is being disposed of in land-ll site.
All of our products are marked with the WEEE symbol; this indicates that this product must NOT be disposed of with other waste. Instead it is the user’s responsibility to dispose of their waste electrical and electronic equipment by handing it over to an approved reprocessor, or by returning it to Powersoft S.p.A. for reprocessing. For more information about where you can send your waste equipment for recycling, please contact Powersoft S.p.a. or one of your local distributors.
Manufacturer:
Powersoft S.p.A. via E. Conti 5 50018 Scandicci (Fi) Italy
We declare that under our sole responsibility the products: Model Names: Quattrocanali 4804,
Quattrocanali 4804 DSP+D, Quattrocanali 2404, Quattrocanali 2404 DSP+D, Quattrocanali 1204, Quattrocanali 1204 DSP+D Intended use: Professional Audio Amplier
Are in conformity with the provisions of the following EC Directives, including all amendments, and with national legislation implementing these directives:
2014/35/EU Low Voltage Directive 2014/30/EU Electromagnetic Compatibility Directive 2011/65/EU RoHs Directive 2014/53/EU Radio Equipment Directive
The following harmonized standards are applied:
EN 55103-1: 2009 /A1: 2012 EN 55103-2: 2009 /IS: 2012 EN 60065: 2014 /AC: 2016
Scandicci, October 2016
Luca Lastrucci Managing Director
For compliance questions only: compliance@powersoft.it
English | 9
Page 10
English
Important Safety Instructions
CAUTION
RISK OF ELECTRIC
SHOCK DO NOT OPEN
The Lighting Flash with Arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltages” within the product enclosure that may be of sufcient magnitude to constitute a risk of shock to persons.
The Exclamation point within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
EXPLANATIONS OF GRAPHICAL SYMBOLS
The CE-mark indicates the compliance with the low voltage and electromagnetic compatibility.
Symbol for earth/ground connection.
Symbol indicating that the equipment is for indoor use only.
Symbol for conformity with Directive 2012/19/EC of the European Parliament on waste electrical and electronic equipment (WEEE).
Do not use the unit at altitudes above 2000 m.
Do not use the unit in tropical environment.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO USER­SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A ELECTROTECHNICAL SKILLED PERSON ACCORDING THE NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT IS SOLD.
USE ONLY BATTERIES, CHARGERS, AND OTHER ACCESSORIES
APPROVED BY POWERSOFT FOR USE WITH THIS DEVICE. PLEASE REALIZE THAT BATTERIES MIGHT CAUSE DAMAGES LIKE LEAKING, FIRE OR EXPLODE WHEN MISUSE OR DEFECTIVE. NEVER MAKE WRONG POLARITY CONNECTION WHEN
CHARGING AND DISCHARGING BATTERY PACKS. ALWAYS DOUBLE CHECK POLARITY OF BATTERY’S CONNECTOR TO MAKE SURE RED WIRE TO RED WIRE AND BLACK WIRE TO BLACK WIRE.
FOR SAFETY REASON, WE USUALLY SHIP BATTERY NOT FULLY
CHARGED: YOU MUST CHARGE THE BATTERY BEFORE USE.
BATTERIES (BATTERY PACK OR BATTERIES INSTALLED) SHALL
NOT BE EXPOSED TO EXCESSIVE HEAT SUCH AS SUNSHINE,
FIRE OR THE LIKE.
WARNING TO PREVENT INJURY, THIS APPARATUS MUST BE
SECURELY ATTACHED TO THE FLOOR/WALL IN ACCORDANCE
WITH THE INSTALLATION INSTRUCTIONS.
Electrical energy can perform many useful functions. This unit has been engineered and manufactured to ensure your personal safety. But IMPROPER USE CAN RESULT IN POTENTIAL ELECTRICAL SHOCK OR FIRE HAZARD.
In order not to defeat the safeguards incorporated into this product, observe the following basic rules for its installation, use and service. Please read these “Important Safeguards”
carefully before use.
Important safety instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not t into your outlet, consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11. Only use attachments/accessories specied by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specied by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. The apparatus shall be connected to a MAINS socket outlet with a protective earthing connection
16. Where the MAINS plug or an appropriate coupler is used as the disconnect device, the disconnect device shall remain readily operable.
WARNING> TO REDUCE THE RICK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR MOISTURE.
DO NOT EXPOSE THIS APPARATUS TO DRIPPING OR SPLASHING AND THAT NO OBJECTS FILLED WITH LIQUID, SUCH AS VASES, SHOULD NOT BE PLACED ON THE APPARATUS.
10 | Quattrocanali Series
Page 11
English
Quattrocanali Series Quick Guide
2
2 : 1.Welcome
Congratulations on buying a Powersoft amplier!
We know you are eager to use your new Quattrocanali amplier, but please take a moment to read this quick guide and the safety instructions. In case you have any questions, please do not hesitate to contact your dealer or Powersoft.
The Quattrocanali Series is specically designed for installation applications. In just 1 RU, Quattrocanali offers smaller dimensions, lighter weight and the traditionally amazing sound quality and reliability of all Powersoft products.
Quattrocanali Series ampliers implement a high efciency microprocessor controlled power supply with built in PFC (Power Factor Correction) that allows awless worldwide operation with any AC mains voltage in the range 85-275 V
AC
tolerant to peak up to 400 V. The patented SRM (Smart Rails Management) technology allows to maximize the efciency of the system and drastically reduce power consumption at any load and usage condition.
A secondary high efcient power supply is present to keep the system responsive at any operating condition, so that system check and monitoring can be performed even in stand-by and deep-sleep modes.
Quattrocanali Series is designed to work with lo-Z (from 2 Ω) and with 70V/100V distributed lines: any mixed conguration of low and high impedance output loads can be realized, making the Quattrocanali Series suitable to all application in installed sound reinforcement system.
DSP+D versions of the Quattrocanali 4804 and 2404 extend system performance with the support to Dante™ digital audio networking architecture and the on board high­end signal processing.
4804 2404 120 4
8 Ω 1200 W 600 W 300 W
4 Ω 1200 W 600 W 300 W
2 Ω 1500 W 800 W 400 W
Hi-Z 70 V 1200 W 600 W 300 W
Hi-Z 100 V 1200 W 600 W 300 W
2 : 2.Unpacking & checking for shipping damage
Your Powersoft amplier has been completely tested and inspected before leaving the factory. Carefully inspect the shipping package before opening it, and then immediately inspect your new product. If you nd any damage notify the shipping company or retailer immediately.
The box contains the following:
1x Quattrocanali Series amplier.1x Phoenix MC 1,5/ 4-ST-3,81 - 1803594 plug2x Phoenix MC 1,5/12-ST-3,81 - 1803675 plug1x Phoenix PC 5/ 8-STF1-7,62 - 1777891 plug1x IEC power cord1x quick guide
2 : 3.Disposal of the packaging material
The protective transport packaging has been selected from materials which are environmentally friendly for disposal and can normally be recycled.
Rather than just throwing these materials away, please ensure they are offered for recycling.
2 : 4.List of image panels
A. Mechanical drawings: all dimensions in millimeters B. Front panel: how to access it C. Quattrocanali Series: Front panel description D. Quattrocanali Series: Rear panel description E. Quattrocanali Series DSP+D: Front panel description F. Quattrocanali Series DSP+D: Rear panel description G. Input connector: wiring (single ended mode) H. Output connector: wiring (single ended mode) I. Alarms connector: wiring J. Input/Output connectors: wiring (bridged mode) K. Output load DIP switch congurations L. RJ45 Ethernet wiring (Color code TIA/EIA-568-B) M. Air ow and mounting brackets N. Rack mounting constraints O. Regulatory information
English | 11
Page 12
English
Installation
3
3 : 1.Location
Quattrocanali Series ampliers are meant to be installed into rack cabinets. In order to limit the risk of mechanical damages, the ampliers must be secured to the rack using both frontal and rear mounting brackets. We recommend to use eight M6 or 12-24 UNC-2B screws for threaded holes or cage nuts.
The AC mains connector of the units must be connected to a proper circuit breaker.
Install this amplier as far as possible from radio tuners and TV sets. An amplier installed in close proximity of such equipment may experience noise or generic performance degradation. Placing and using the amplier for long periods of time on heat generating sources will affect its performance. Avoid placing the amplier on heat generating sources.
3 : 2.Cooling
Install the amplier in a well-ventilated location: the ventilation openings must not be impeded by any item such as newspapers, tablecloths, curtains, etc; keep a distance of at least 50 cm from the front and rear ventilation openings of the amplier.
All Powersoft ampliers implement a forced-air cooling system to maintain low and constant operating temperatures. Drawn by the internal fans, air enters from the front panel and is forced over all components, exiting at the back of the amplier.
The amplier’s cooling system features “intelligent” variable-speed DC fans which are controlled by the heat sink temperature sensing circuits: the fans speed will increase only when the temperature detected by the sensors rises over carefully predetermined values. This ensures that fan noise and internal dust accumulation are kept to a minimum.
Should however the amplier be subject to an extreme thermal load, the fans will force a very large volume of air through the heat sink. In the extremely rare event that the amplier should dangerously overheat, sensing circuits shut down all channels until the amplier cools down to a safe operating temperature. Normal operation is resumed automatically without the need for user intervention.
Quattrocanali Series ampliers can be stacked one on top of the other due to the efcient cooling system they are equipped with.
There is however a safety limit to be observed: in case a rack with closed back panels is used, leave one rack unit empty every four to guarantee adequate air ow (see Panel
N, p. 8).
3 : 3.Cleaning
Always use a dry cloth for cleaning the chassis and the front panel. Air lter cleaning should be scheduled according to the dust levels in the amplier’s operating environment.
Disconnect the AC mains source before
attempting to clean any part of the amplifier
In order to clean the vent lters you need to remove the front cover: never attempt to open any other part of the unit.
1. Firmly grip the outermost silver panel and pull it outwards (seePanel B, p. 4).
2. When the front panel is removed, the air lter (looking like a shiny black plastic sponge) will be exposed.
You may use compressed air to remove the dust from lters, or wash it with clean water: in the latter case ensure that the lter is dry prior to reassembly.
3 : 4.Precautions regarding installation
WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK
This device must be powered exclusively by earth
connected mains sockets in electrical networks compliant to the IEC 364 or similar rules.
Install the unit into a rack cabinet.
A sectioning breaker between the mains connections
and the amplier should be installed inside the rack cabinet.
Properly t the AC mains plug to the amplier inlet.
Before powering this amplier, verify that the correct
voltage rating is being used.
Verify that your mains connection is capable of
satisfying the power ratings of the device.
Do not use this amplier if the electrical power cord is
frayed or broken.
Output terminals are hazardous: wiring connection to
these terminals require installation by an instructed person and the use of ready-made leads.
Take care to lock the output terminal before switching
the device on.
To avoid electrical shock, do not touch any exposed
speaker wiring while the amplier is operating.
Do not spill water or other liquids into or on the amplier.
No naked ame sources such as lighted candles
should be placed on the amplier.
Do not remove the cover. Failing to do so will expose
you to potentially dangerous voltage.
The manufacturer cannot be held responsible for
damages caused to persons, things or data due to an improper or missing ground connection.
Contact the authorized service center for ordinary and
extraordinary maintenance.
It is absolutely necessary to verify these fundamental
requirement of safety and, in case of doubt, require
an accurate check by qualified personnel.
12 | Quattrocanali Series
Page 13
English
This device must be powered exclusively by earth connected mains sockets in electrical
networks compliant to the IEC 364 or similar rules.
Powersoft suggests to plug the
Quattrocanali to a 16 A rating,
C or D curve, 10 kA sectioning breaker.
AC mains connections must be performed
only by professional or qualified personnel
according to local electrical authorities guidelines.
3 : 5.AC mains supply
Quattrocanali Series ampliers implement an universal switching mode power supply with power factor correction operating in the range from 100 V
AC
up to 240 VAC ±10%.
AC mains connection is in the rear panel through the IEC C20 inlet: the approved power cord is provided (seePanel
K, p. 7).
3 : 6.Switch ON/OFF
Once properly powered (power cord inserted, sectioning breaker closed), the system can be either ON or in STANDBY mode depending on its state at latest power off.
In order to toggle the amplier ON and STANDBY keep pressed the power button for 3 seconds (see Panel
C, p. 5). Please consider that the operating condition
can be modied by the REMOTE ON and REMOTE OFF conguration (see §3 : 9.Remote ON/OFF (standby mode)).
3 : 7.Energy save
The Smart Rails Management technology implemented in the power supply u nit allows to reduce the power cons umption when the input signal falls under a dened threshold.
Signal activity is monitored on the input section of the amplier so that the system can resume normal operation in a matter of milliseconds when an incoming signal is detected on the channels. Once switched on, Energy Save is active on each channel independently.
If the signal is missing for more than 30 minutes on all channels, the auto standby is applied and the main PSU is turned off to further save energy*. Normal operation is resumed in a matter of milliseconds when an incoming signal is detected on the channels.
In order to activate the Energy Save feature, locate the NRG SAVE switch on the rear panel (see Panel D, p. 5) and set it ON (high).
TAB . 1 shows the power consumption in idle mode when
the Energy save is either enabled or disabled.
Energy
Save
115 V
AC
mains 230 VAC mains
Current
Real
Power
Apparent
Power
Current
Real
Power
Apparent
Power
4804
OFF
0.45 A 32.3 W 74 VA 0.35 A 32.4 W 142 VA
AUTOSTBY
0.45 A 19 W 52 VA 0.46 A 20 W 10 6 VA
4804
DSP+ D
OFF
0.5 A 33.6 W 76 VA 0.35 A 33.7 W 145 VA
AUTOSTBY
0.47 A 20 W 55 VA 0.57 A 21 W 131 VA
2404
OFF
0.40 A 31.4 W 69 VA 0.28 A 31.6 W 138 VA
AUTOSTBY
0.45 A 19 W 52 VA 0.45 A 19 W 104 VA
2404
DSP+ D
OFF
0.45 A 32.7 W 70 VA 0.29 A 31.8 W 140 VA
AUTOSTBY
0.46 A 20 W 5 3 VA 0.46 A 20 W 106 VA
1204
OFF
0.40 A 31.4 W 69 VA 0.28 A 31.6 W 138 VA
AUTOSTBY
0.45 A 19 W 52 VA 0.45 A 19 W 104 VA
1204
DSP+ D
OFF
0.45 A 33.6 W 70 VA 0.29 A 32.8 W 140 VA
AUTOSTBY
0.46 A 20 W 5 3 VA 0.46 A 20 W 106 VA
TAB. 1: Idle consumption.
3 : 8.Breaker save
In case the power grid is unable to provide enough current to continuously drive the loads, or when the number of attached amplier to the same AC mains is such that one can reach the critical power absorption from the line, it is possible to activate the Breaker Save feature.
When activated, the Breaker Save feature reduces (halves) the maximum continuous current absorption from the mains. This slightly reects on the overall performance of the system reducing the available output power.
In order to activate the Breaker Save feature, locate the BRK SAVE switch on the rear panel (see Panel D, p. 5) and set it ON (high).
3 : 9.Remote ON/OFF (standby mode)
Remote ON/OFF is available through the dedicated terminals on the rear panel (see Panel C, p. 5).
Both terminals respond to the differential voltage between the contacts: a voltage difference in the range 5 V
DC
- 24 VDC triggers the control. Any voltage exceeding
28V
DC
may damage the input circuitry.
The couple of terminals act depending on the actual state of the amplier, as shown in .
REMOTE ON REMOTE OFF AM PL IF IE R S TATE
Vdiff ≥ 5V Any Force Turn ON
Vdiff < 3V Vdiff ≥ 5V Force Turn OFF
Vdiff < 3V Vdiff < 3V
No Change
(Keep either standby
or in current state)
In order to remotely toggle between standard operating and standby modes, the AC mains power must be connected.
*Time out time is selectable via Armonìa in DSP+D Versions
FIG. 1: Keep pressed the power pushbutton
to toggle ON/STANDBY the amplifier.
English | 13
Page 14
English
Connections
4
Make sure the external breaker is off before attempting
to make any input or output connections.
By using good quality input and output speaker cables, the likelihood of erratic signal behavior is reduced to a minimum. Whether you make them or buy them, look for good quality wires, connectors and soldering techniques.
4 : 1.Signal grounding
There is no gr ound switch or terminal on the Qu attrocanali Series ampliers. All shield terminals of input connections are directly connected to the chassis. This means that the unit’s signal grounding system is automatic. In order to limit hum and/or interference entering the signal path, use balanced input connections.
In the interests of safety, the unit MUST always operate with electrical safety earth connected to the chassis via the dedicated Protective Earth
wire.
4 : 2.Analog audio input connections
Analog input connections are made via the Phoenix MC 1,5/12-ST-3,81 1803675 connector. Signal polarity of analog input connections is shown in Panel E, p. 6.
Short the Positive (+) and Negative (-) to the Ground Input terminal on the unused Input channel(s) in order to avoid picking up noise.
4 : 2.1. Remote level adjustment
The level of each channel of the Quattrocanali Series ampliers can be remotely adjusted by means of a linear 10 kΩ potentiometer connected to the input LEVEL connector (see Panel D, p. 5) through a Phoenix MC 1,5/12-ST- 3,81 1803675 plug. The right polarity for the connections is shown in Panel G, p. 6.
When the CH1 MSTR switch is in the OFF position (low) the remote level potentiometers work independently on each separate channel.
When the CH1 MSTR switch is in the ON position (high) the remote level potentiometer of the channel 1 acts as a master level, controlling the volume of all the four channels.
The remote level controls are in series with the level adjustment knobs in the front panel.
4 : 3.Digital audio input connections
The Dante equipped models of Quattrocanali DSP+D accepts four input streams from the Dante connection through the Dante port. Cabling must comply to TIA/EIA­568-B and adopt the T568B scheme pinout, as shown in
Panel O, p. 8.
In order to implement a Dante network, a computer running Dante Controller have to be used. Dante Controller is a software application that manages devices on the network. Quattrocanali DSP+D ampliers are automatically
discovered and displayed in Dante Controller with the default identier
MODELNAME-SERIAL
(e.g. Quattroca nali4804-71520).
4 : 3.1. Input selection and Backup policy
In Quattrocanali DSP+D ampliers it is possible to select among two input signal sources per channel: analog and Dante streams. The Armonía Pro Audio Suite software provides an interface to select the proper input source, manage input gain and delay of the analog and digital sources, in order to compensate transmission latency and levels.
Furthermore Quattrocanali DSP+D ampliers implement a backup policy aimed to improve reliability against signal fault. By assigning a bus priority to the two different input sources per channel, the system is able to automatically switch to a reliable input connection in case of signal drop or pilot tone mismatch.
4 : 4.Ethernet connections
The port labeled Ethernet is designed to remotely control the Quattrocanali DSP+D via an Ethernet connection through a personal computer and Powersoft Armonía Pro Audio Suite software. A complete interface for signal routing, sound shaping and performance ne tuning is provided.
Powersoft recommend the use of Ethernet Cat5 straight through – patch – cables with pin/pair assignments TIA/EIA­568-B, i.e. T568B, as shown in Panel O, p. 8.
4 : 5.Output connections
CLASS3
CLAS S 3 WIRING
Output terminals are hazardous: wiring connection to
these terminals require installation by an instructed person and the use of ready made leads. Take care to secure the output terminal before switching the device on.
Output connections are made via the Phoenix PC 5/ 8-STF1-7,62 1777891: single-ended wirings for lo-Z loudspeaker and Hi-Z distributed lines connections are shown in Panel I, p. 6. Bridge-tied connection of lo-Z loudspeaker is supported on adjacent channel pairs 1-2, 3-4, 5-6 and 7-8; inputs must be physically paralleled as shown in Panel J, p. 6.
Any mixed conguration of low and high impedance output loads can be made: in order to set the load conguration, each channel is provided by four DIP switches (refer to Panel L, p. 7). Quattrocanali Series is congured to drive Lo-Z loads by factory default.
4 : 5.1. Hi-Z 70V/100V operations
Any channel of an Quattrocanali Series amplier can drive 70V/100V (Hi-Z) distributed line of loudspeakers. In order to connect any channel’s output to a 70V/100V line, the rear panel DIP switch corresponding to the channel must be correctly set as indicated in Panel L, p. 7.
Powersoft recommends to use the built-in HPF (High Pass Filter) when the amplier is set to drive a distributed line to prevent loudspeaker transformer saturation which can considerably degrade sound performance. The HPF can be activated by means of the DIP switch corresponding to the channel (see Panel L, p. 7), two cutting frequency are available 35 Hz and 70 Hz.
14 | Quattrocanali Series
Page 15
English
4 : 6.Gain selection
The Quattrocanali Series ampliers can operate with different gain applied to the input signal. This feature is designed to match the voltage of the input signal, i.e. allowing to obtain the same output power at different input levels.
GAIN
Input sensitivity @ 8Ω load
Vpeak Vrms dBu
4804
26 6,92 4,9 16,0 29 4,90 3,47 13,0 32 3,46 2,45 10,0 35 2,45 1,74 7,0
2404
26 4,89 3,46 13 ,0 29 3,48 2,46 10,0 32 2,45 1,74 7,0 35 1,74 1, 23 4,0
120 4
26 3,46 2,45 10,0 29 2,46 1,74 7,0 32 1,72 1,23 4,0 35 1,23 0,87 1,0
TAB. 2: Input sensitivity.
A proper combination of the position of two GAIN switches on the rear panel sets the operating gain of the amplier (see TAB . 3)
26 dB 29 dB 32 dB 35 dB
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
1 2 34 5 6 7 8
TAB. 3: Setting the GAIN.
4 : 7.Lo-Z 2Ω load operation
The Quattrocanali Series ampliers are optimized for working with 4Ω output loads but a special configuration allows to connect low loads down to 2Ω (e.g. in the configuration with three paralleled 8Ω loudspeakers that provides 2.67Ω load to the output channel).
The 2Ω switch (see Panel D, p. 5) allows to activate on all output channels set to match low impedance (i.e. in Lo-Z configuration) an operating condition that optimizes the performance with very low loads, by limiting the maximum output voltage to 85V
peak
per channel.
For optimal 2Ω performance, it is recommended to select LowZ mode for all the amplifier’s channels
4 : 8.Diagnostics - GPO - Alarms
The Quattrocanali’s GPO – general purpose output – system implements triggering signals to broadcast alarms.
Quattrocanali Series provides a pair of paralleled general purpose output connections per channel: one Normally Open
NO and one Normally Closed NC.
The connections are available on the back panel via the 12-pin Phoenix MC 1.5/12-ST-3.81 1803675 connector: see
Panel F, p. 6 for wirings.
These contacts are used to report potentially dangerous faults or generally unsafe operation conditions by toggling alarm switches relative to the following events, and any fault preventing the normal operation of an output channel:
No AC mains (i.e. system shutdown);Thermal stress: the system temperature is too high
and the thermal protection is engaged;
Short circuit in output wiring: either the loudspeaker or
the line is in short;
Amplier is in Standby
Quattrocanali DSP+D features further monitoring on pilot tone and output load: the monitoring and diagnostic interface is accessible in Armonía Pro Audio Suite software through the Diagnostic tab in the output ways panel of the selected channel of the Quattrocanali DSP+D amplier.
4 : 8.1. Pilot tone monitoring
Thanks to the built-in DSP, the Quattrocanali DSP+D ampliers implement pilot tone detection and alert. Detecting and alerting features are available for both input and output pilot tones on each channel.
The detection of a mismatch in the input pilot tone parameters (frequency and voltage level) can be used to trigger the backup policy and activate an alert through the general purpose output switch.
The output pilot tone detection relies on an external signal passing through the amplier or the internal post DSP pilot tone generator; in both cases any mismatch between the detected signal and the set thresholds triggers the general purpose output switches.
4 : 8.2. Output load monitoring
Through the Armonía Pro Audio Suite software it is possible to set the thresholds on the load impedance, at given frequency, that trigger the general purpose output of any channel in Quattrocanali DSP+D ampliers.
FIG. 2: Diagnostic panel in Armonía Pro Audio Suite.
English | 15
Page 16
English
LED chart
5
The front LED panel of the Quattrocanali includes four LED bars for output signal metering and one LED strip with status indicators. Two operating mode LEDs are located on the control panel under the left hand cover.
5 : 1.LED bars: signal metering
The four left hand LED bars provide signal metering and channel status for channels 1 to 4 left to right.
Color
Signal
metering
Warnings
Lighting Description
ORANGE
Clipping
*DSP+D User L imiter
YELLOW
-6dB SOLID ON
Thermal warning
Thermal protection
engaged
GREEN
-12d B
GREEN
-24dB
GREEN
-60dB
SOLID ON Signal presence
BLINKING Channel muted
GREEN
SOLID ON Channel ready
FLASHING Auto Standby
RED
SOLID ON Channel fault
1
FLASHING User Diagnostic Fault
1
Red LED lights on in case of any kind of channel fault that prevents the normal
channe l operating; at the same time the rear corresponding GPO tog gles the contac ts NO into NC and NC into NO.
5 : 3.Operating mode LEDs
The operating mode LEDs are located on the control panel. They state the operating mode when the system either is on or in standby mode.
Color Name
Operating mode
Standby Power on
GREEN
POWER ON SOLID ON
ORANGE
STA NDBY SOLID ON
ORANGE
AUTO STANDBY BLINKING
ORANGE
ERROR CODE BLINK COUNTER
5 : 2.LED strip: system status
The right hand LED strip on the LED panel provides
system status informations.
Color Name
Warnings
Lighting Description
ORANGE
LIMIT
FLASHING Breaker Save Enabled
SOLID ON
Breaker Save limiting
power draw
YELLOW
TEMP SOLID ON
Thermal warning
Thermal protection
engaged
ORANGE
CHECK
SOLID ON System self checking
BLINKING Self check completed
FAST BLINKING Self Check Unavailable
GREEN
REMOTE
SOLID ON
Connec ted to
Armonía or 3rd Party
Remote Control
FLASHING
Preset Changed /
Disconnected
GREEN
POWER ON
SOLID ON System ready
OFF System of f
GREEN
MAINS
SOLID ON
AC mains voltage
within the operating
range
OFF Undervoltage
FLASHING
Over/Undervoltage
Warning
FAST BLINKING Overvoltage
SLOW BLINKING Mains FUSES blown
RED
ALARM SOLID ON
PSU fault
1
OR Critical Faults
1
Red LED lights on in case of any kind of PSU fault that prevents normal
operating.
Control Panel
6
The control panel is located under the left hand metal cover. See Panel B, p. 4 on how to access the control panel.
The control panel contains two LEDs (for the description see §5 : 3.Opera ting mod e LEDs) and the following controls.
The push-buttons are disabled when connected to Armonìa.
Label Type Action Description
POWER
Pushbutton
keep pressed for
3 seconds
Tog gl e
system ready/standby mode
CALL
Pushbutton press
Highlight the amplier in the
Armonía workspace
SOFT
RESET
1
Pushbutton
keep pressed for
3 seconds
Reset network parameters
to factory default
HARD
RESET
1
Pushbutton
keep pressed for
3 seconds
Reboot the system
CHECK
2
Pushbutton
keep pressed for
3 seconds
Start the self-checking
procedure*
CH1
3
Potentiometer
turn
counter-clockwise
Attenuate the output l evel of
the signal on channel 1
CH2
3
Potentiometer
turn
counter-clockwise
Attenuate the output l evel of
the signal on channel 2
CH3
3
Potentiometer
turn
counter-clockwise
Attenuate the output l evel of
the signal on channel 3
CH4
3
Potentiometer
turn
counter-clockwise
Attenuate the output l evel of
the signal on channel 4
1. Keep pressed both the SOFT RESET button and the HARD
RESET button for at least 3 seconds to completely reset the amplier to its factory default conguration (any preset stored in the internal memory will be lost and replaced with a at preset).
2. For further information see §6 : 1. Self check.
3. The potentiometer is in series with the remote level control (see
§4 : 2.1. Remote level adjustment) so it can be used to limit the
output volume regardless to any remote adjustment.
* Press again to resume normal operations
6 : 1.Self check
The self check procedure tests the amplier status and reports the user in case of failures.
It is highly recommended to unplug the
output connectors before proceeding
with the self check procedure
The testing signals might cause
loudspeaker impairments.
After few minutes, at the end of the self check procedure, a combination of lighten LED in the LED panel provide information about the amplier status.
In order to exit the self check test and resume normal operations, press once the self check push button.
16 | Quattrocanali Series
Page 17
English
Quattrocanali ampliers support star network topology via the Ethernet port and Dante networking via the Dante port only.
The Ethernet port is designed to allow the remote control of the amplier through Armonía Pro Audio Suite and third party software. The Dante port is reserved to Dante networking.
7 : 1.IP addressing
Factory default network settings are DHCP/AutoIP, inorder for the amplier to self-congure when connected to an existing LAN or PC. Fixed IP policy can also be adopted and congured through Armonía Pro Audio Suite.
If a DHCP server is not active within the network, the amplier platform initiates a stateless address auto-conguration (i.e. Zero-conguration networking methodology – Zeroconf): it self assigns a local numeric network address (of the type 169.254.x.y – 172.31.*.* for the secondary network if present – with a subnet mask
255.255.0.0) and automatically distributes and resolves the host names of the networking devices. For setting a static IP address please refer to the Armonía Pro Audio Suite user guide.
7 : 1.1. IP Addressing troubleshooting
When connecting the Quattrocanali to a network environment it may happen that Armonía Pro Audio Suite does not discover or import the amplier.
Usually this is a problem of IP addressing: both Armonia and the Quattrocanali must belong to the same subnet. If a DHCP server is present on the network and a Quattrocanali amplier is in AUTO IP, networking may become unstable.
As a rule of thumb, turn the DHCP server
on before connecting the amplifiers.
IP addressing of a Quattrocanali amplier is established during the bootstrap: when the amplier discovers a DHCP server on the network during the startup, it negotiates the networking parameters. If the Quattrocanali does not reveal a DHCP server on the network during the startup, it set itself in AUTO IP mode.
Networking
7
6 : 1.2. Channel faults
If self check cannot be started because of a fault, the check LED will blink fast, whilst a reassuring slow blink is an indication of a completed self check procedure.
FIG. 3: System OK.
FIG. 5: AC Mains voltage out of range (over/ under voltage)
FIG. 6: PSU temperature out of range
FIG. 7: Fan Error
FIG. 8: Channel# Temperature out of range
FIG. 9: Channel# Output Waveform non-conformity
6 : 1.1. Global faults
FIG. 4: Power supply fault
English | 17
Page 18
English
Armonía Pro Audio Suite
Armonía Pro Audio Suite is the default conguring interface that allows system setting and customization of the Quattrocanali DSP+D ampliers.
Armonía can be installed on a PC running Windows (XP SP3 and higher). Freely download Armonía Pro Audio Suite from the Armonía forum:
http://www.powersoft-audio.com/en/armonia-forum
Quattrocanali DSP+D ampliers can connect to the PC running Armonía through a Fast Ethernet connection. In order to start remote operation the device must be discovered and imported into the Armonía Workspace. Click on the Discover button in the Remote entities window, or select it from the Model list and drag it into the Armonía Workspace.
The callback button (see Panel C, p. 5) allows you to highlight the presence of the amplier into the Armonía Workspace.
Once connected to Armonía Pro Audio Suite a double click on the amplier icon in the Workspace will open the amplier dashboard. Here it is possible to access and congure all the features of the Quattrocanali DSP+D.
8
8 : 1.Signal routing and DSP architecture
Signal processing on Powersoft Quattrocanali DSP+D ampliers accomplishes multiple functions that affect the audio signal before power amplication; the main adjustments include gain, polarity, delay, limiting and signal equalization; some processing are related only to particular stages, such as limiting and damping control that are implemented on the output section only, or input priority assignment available in the input section.
The processing architecture is composed of six sections:
Input source selection. The input section allows you
to manage input gain and delay of analog and digital sources, in order to compensate transmission latency and levels. Furthermore the Quattrocanali DSP+D implement a backup policy aimed to improve reliability against signal fault.
Matrix. The innovative routing engine of Quattrocanali
DSP+D allows any input to be routed to any output. The Matrix implements a non-boolean rooting architecture allowing free channel assignment and level adjustment.
Advanced processing. This allows you to optimize
levels and shape the sound of the input signals. Gain and polarity adjustment, asymmetric raised-cosine full parametric lters, delay and mute are available on each channel routed to the speaker section.
Speaker equalization. Designed to manage the
conguration presets for multi-way systems, it implements FIR and IIR full parametric lters.
Speaker routing. Once properly grouped, the output
channels are presented to the matrix as speakers – asingle row representing a speaker (actually group of ways) – allowing a high grade of granularity in signal processing.
Output processing. This allows ne tuning of output
signals, aiming to optimize the power delivered and the performance of the single way out. It provides gain and polarity adjustment, IIR and FIR full parametric lters, delay, mute, limiting and damping control on each output channel.
8 : 2.Purposed workflow
Once the loudspeaker layout has been dened, we suggest a bottom-up conguration procedure that starts from the conguration of the transducers layout and goes up toward the input selection and the denition of the backup policy.
Shortly, the main steps to follow are:
1. Set Lo-Z and Hi-Z loads and lters on output channels.
2. Load the loudspeaker presets or manually congure the loudspeaker layout (grouping output channels, limiting, speaker processing, etc.).
3. Dene the routing path and the levels of the signals from the input channels to the active output channels (matrix).
4. Select the signal source from the input connections and dene the backup policy (input source selection).
5. Dene GPO assignment and alarms thresholds.
Through Armonía Pro Audio Suite software it is possible to set the thresholds on the load impedance, at given frequency, that trigger the general purpose output of any channel in Quattrocanali DSP+D ampliers (see FIG. 5).
FIG. 11: GPO: System monitoring interface.
8 : 3.Live Impedance
FIG. 10: Armonía Pro Audio Suite.
18 | Quattrocanali Series
Page 19
English
9
Warranty and assistance
9 : 1.Warranty
Powersoft guarantees its manufactured products to be free from defective components and factory workmanship for a period of time starting from the date of purchase printed on Powersoft’s (or any of its Authorized Dealer’s) invoice to the end customer. The standard warranty period are:
48 months for racks ampliers. 12 month for amplier modules.
All warranty repairs and retrots must be performed at Powersoft facilities or at an Authorized Service Center at no cost for the purchaser. Warranty exclusion: Powersoft’s warranty does not cover product malfunctioning or failure caused by: misuse, abuse, repair work or alterations performed by non-authorized personnel, incorrect connections, exposure to harsh weather conditions, mechanical damages (including shipping accidents), and normal wear and tear. Powersoft will perform warranty services provided that the product is not damaged during transportation.
9 : 1.1. Return of Goods
Goods can be returned to Powersoft only after they have been granted a Return Merchandise Authorization (RMA) number to be attached to the external packaging. Powersoft (or its Authorized Service Center) has the right to refuse any returned good without a RMA number.
9 : 1.2. Repair or replacement
Powersoft reserves the right to repair or replace any defective goods covered by product warranty at its sole discretion and as it deems best.
9 : 1.3. Cost and responsibility of transport
The purchaser (or end user/customer) is solely responsible for all transportation costs and risks associated with sending warranty covered goods to Powersoft or its
9 : 2.Assistance
There are no user-serviceable parts in the amplier. Refer to qualied technical personnel for servicing. In addition to having an in-house service department, Powersoft supports a network of Authorized Service Centers. If your amplier needs repair, contact your Powersoft dealer (or distributor). You can also contact the Powersoft Technical Service department to obtain the location of the nearest Authorized Service Center.
Powersoft offers two options for product repair:
Drop off at a Powersoft Authorized Service Centre near you.Ship the product to Powersoft S.p.a. for Factory
Service.
9 : 2.1. Drop off at a Powersoft Authorized Service Centre near you
Find a Powersoft Authorized Service Centre from the list.Take a note of each serial number of the units to be
returned.
Completely ll out the defect report form for each unit to
be returned.
Send the completed defect report form to the following
e-mail addresses marco.mannucci@powersoft.it (Customer care manager) service@powersoft.it (Service Team).
After having applied the aforementioned procedure, the local service manager will provide the shipment details and the product’s warranty status.
9 : 2.1.1. In-Warranty repairs:
The service repair will be free of charge for the customer.
9 : 2.1.2. Out of Warranty Issues
The service costs are calculated on the local rate
applied from the service centre and supervised by the Powersoft HQ
The repair time has been set from the Powersoft HQ and
it’s equally applied in all the authorized service centre
The unit will be evaluated by a technician, and the
service centre will provide the customer with the estimated costs. The repair will only take place once the customer has approved the estimated costs. The customer will pay the shipping charges once the repair has been completed, depending on the countries’ standard procedures.
For any enquiries please contact Powersoft Customer care service@powersoft.it
The row of potentiometers in the front panel behave differently on non-DSP ampliers and Quattrocanali DSP+D ampliers:
In non-DSP Quattrocanali ampliers, the potentiometers
act as trimmers on the input level (see Panel C, p.
4): the input signal is muted when the trimmer is
completely turned counterclockwise; on the other hand, no attenuation is applied when the trimmer is completely turned clockwise.
In Quattrocanali DSP+D the potentiometers attenuate
the speakers gain (see Panel E, p. 6): they modify the overall gain applied to the group of ways belonging to the selected speaker. The amount of gain attenuation (External gain) is shown in Armonía Pro Audio Suite.
Authorized Service Center. Powersoft will assume full responsibility and cover all costs incurred to send the goods back to the purchaser (or end user/customer).
English | 19
Page 20
English
9 : 2.2. Shipping the product to Powersoft S.p.a. for Factory service centre
Take a note of each serial number of the units to be
returned.
Fill out completely the defect report form for each unit
to be returned.
Send the completed defect report form to the following
email address: service@powersoft.it
After having applied the aforementioned procedure, you will receive an Email containing the Return Merchandise Authorization (RMA form) for each unit returned.
All returned Powersoft units must be shipped to the following address:
Powersoft spa
Factory service centre
Via Enrico Conti N. 13 – 15
50018 Scandicci (FI)
Italy
Phone +39 (055) 7350230 Option 2
Email: service@powersoft.it
Contact Powersoft Factory service centre
Phone +39 (055) 7350230 Option 2
Email: service@powersoft.it
Phone Support Hours
Monday - Friday 8.30 AM to 5.30 PM Europe time
9 : 2.2.1. Shipment from NON-CE countries
When shipping from non-CE (European Community) countries , follow the proce dure descr ibed in the TEMP ORARY EXPORTATION / IMPORTATION PROCEDURE.
Important Note:
If the RMA# is not displayed anywhere on the outside of the box, the shipment will be rejected and sent back to the customer.
If the returned goods from NON-CE countries do not follow the aforementioned guidelines, the package will be rejected and sent back to the customer.
9 : 2.3. D.O.A. Procedure
In case of a D.O.A. (Dead On Arrival) product, we kindly request the customer to contact the local dealer where the product was purchased or the Factory service centre, mentioning the serial number of the faulty unit.
D.O.A. unit will be replaced completely without any additional charges!
Important Note: Do not tamper with or operate the D.O.A. unit in any ways in order to avoid any warranty issue.
Powersoft S.p.a declines any D.O.A warranty service if the returned unit has been tampered with or misused by the customer.
20 | Quattrocanali Series
Page 21
Specifications
Quattrocanali 4804
Networking
Standards compliance auto-sensing Fast Ethernet (IEEE 80 2.3u, 100 Mbit /s)
Supported topologies Star
Remote inter face Armonía Pro Audio Suite™
DSP*
AD conver ters
24 Bit Tandem™ @ 48 kHz
125 dB-A Dyna mic Range - 0.005 % THD+N
DA conver ters
24 Bit Tandem™ @ 48 kHz
117 dB-A Dynamic Range - 0.0 03 % THD+N
Sample rate converter
24 Bit @ 44.1 kHz to 192 kHz
140 dB Dynamic Range - 0.00 01 % THD+N
Internal precision 32 bit oating point
Latency 2.5 ms xed latency architecture
Memory/Presets 128 MB (RAM) plus 512 MB ash for presets
Delay 2 s (input) + 100 ms (output) for time alignm ent
Equalizer
Raised-cosine, custom FIR, parametr ic IIR:
peaking, hi/lo-shelving, all-pass,
band-pass, band-stop, hi/lo-pass
Crossover
linear phase (FIR), Butterworth,
Linkwitz-Riley, Bes sel: 6 dB/oct to 48 dB/oct (IIR)
Limiters TruePower™, RMS voltage, RMS cur rent, Peak limiter
Damping control
Active DampingControl™ and
LiveImpedance™ measurement
Audio
Gain 26 dB 29 dB 32 dB 35 dB
Input sensitivity @ 8  4.9 V 3 .47 V 2.45 V 1.73 V
Max input level 20 dBu
Frequency Response ( ±0.5 dB , 1 W @ 8 ) 20 Hz - 20 kHz
Crosstalk (1 kHz) typic al -70 dB
S/N (32 dB gain, analog input 20 Hz - 20 kHz @ 8 ) > 110 dB(A)
Input impedance 20 k bala nced
THD+N (from 0.1 W to Full Power)
< 0.1%
(typical < 0.05%)
DIM (from 0.1 W to Full Power) < 0.0 5%
Slew Rate (input lter bypassed @ 8 ) > 50 V/µs
Damping Factor @ 8 , 20 Hz - 100 Hz > 500
Channel Handling
Number of output channels
4 Hi-Z or Lo-Z
(bridg eable per ch. pair)
Phoenix PC 5/8-STF1-7,62
Number of input channels
Analog 4 Phoenix MC 1,5/12-ST-3,81
Dante™* 4 1 x RJ45
Construction
Dimensions
483 x 44.5 x 358 mm
19.0 x 1.75 x 14.1 in
Weight 7.0 Kg (15.4 lb)
AC Mains Power
Power supply Universal regulated switch mode with PFC, SR M
Nominal voltage (±10%) 100-240 V @ 50-60Hz
Power fac tor (> 50 0 W ouput) > 0.95
Consumption/current draw @ 115 V @ 23 0 V
Idle 32.3 W 0.45 A 32.4 W 0.33 A
Idle (DSP+D) 33.6 W 0.5 A 33.7 W 0.35 A
1/8 Max Outp ut Power @ 4  850 W 9.16 A 826.8 W 5.02 A
1/4 Max Output Power @ 4  1718 W 15.96 A 1651 W 9.41 A
AC Mains co nnector
IEC C20 inlet (20 A max)
region-specic power cord provided
Thermal
Operating temperature -10° - 35° C / 14° - 95° F
Cooling
Fan, continuously variable speed,
temperature controlled, front to rear a irow
Thermal dissipation @ 115 V @ 230 V
Idle 110.3 BTU/h 27.8 kcal/h 110.6 BTU/h 27.9 kcal/h
Idle (DSP+D) 114.7 BTU/h 28.92 kcal/ h 115.1 BTU/h 29.02 kcal/h
1/8 Max Outp ut Power @ 4  853.5 BTU/h 215.2 kcal/h 768.1 BTU/h 193.7 kcal/h
1/4 Max Output Power @ 4  1768.5 BTU/h 445.9 kcal/h 1539.8 BTU/h 388.3 kcal/h
Output Stage
Maximum output power per channel @ 8  1200 W
Maximum output power per channel @ 4  1200 W
Maximum output power per channel @ 2  1500 W
Maximum output power @ 4  Bridged 3000 W
Maximum output power @ 8  Bridged 240 0 W
Maximum output power @ Hi-Z distributed line 100 V 1200 W
Maximum output power @ Hi-Z distributed line 70 V 120 0 W
Maximum unclipped output vol tage @ 8  139 V
peak
Maximum output current 45 A
peak
T he power gure is calculated by driving and loading symmetrically all the channels: uneven loads allow to achieve higher performances.
Quattrocanali 4804 DSP+D
English | 21
Page 22
Quattrocanali 2404
Networking
Standards compliance auto-sensing Fast Ethernet (IEEE 80 2.3u, 100 Mbit /s)
Supported topologies Star
Remote inter face Armonía Pro Audio Suite™
DSP*
AD conver ters
24 Bit Tandem™ @ 48 kHz
125 dB-A Dyna mic Range - 0.005 % THD+N
DA conver ters
24 Bit Tandem™ @ 48 kHz
117 dB-A Dynamic Range - 0.0 03 % THD+N
Sample rate converter
24 Bit @ 44.1 kHz to 192 kHz
140 dB Dynamic Range - 0.00 01 % THD+N
Internal precision 32 bit oating point
Latency 2.5 ms xed latency architecture
Memory/Presets 128 MB (RAM) plus 512 MB ash for presets
Delay 2 s (input) + 100 ms (output) for time alignm ent
Equalizer
Raised-cosine, custom FIR, parametr ic IIR:
peaking, hi/lo-shelving, all-pass,
band-pass, band-stop, hi/lo-pass
Crossover
linear phase (FIR), Butterworth,
Linkwitz-Riley, Bes sel: 6 dB/oct to 48 dB/oct (IIR)
Limiters TruePower™, RMS voltage, RMS cur rent, Peak limiter
Damping control
Active DampingControl™ and
LiveImpedance™ measurement
Audio
Gain 26 dB 29 dB 32 dB 35 dB
Input sensitivity @ 8  3.46 V 2.46 V 1.73 V 1.23 V
Max input level 20 dBu
Frequency Response ( ±0.5 dB , 1 W @ 8 ) 20 Hz - 20 kHz
Crosstalk (1 kHz) typic al -70 dB
S/N (32 dB gain, analog input 20 Hz - 20 kHz @ 8 ) > 108 dB(A)
Input impedance 20 k bala nced
THD+N (from 0.1 W to Full Power)
< 0.1%
(typical < 0.05%)
DIM (from 0.1 W to Full Power) < 0.0 5%
Slew Rate (input lter bypassed @ 8 ) > 50 V/µs
Damping Factor @ 8 , 20 Hz - 100 Hz > 500
Channel Handling
Number of output channels
4 Hi-Z or Lo-Z
(bridg eable per ch. pair)
Phoenix PC 5/8-STF1-7,62
Number of input channels
Analog 4 Phoenix MC 1,5/12-ST-3,81
Dante™* 4 1 x RJ45
Construction
Dimensions
483 x 44.5 x 358 mm
19.0 x 1.75 x 14.1 in
Weight 6.8 Kg (15.0 lb)
AC Mains Power
Power supply Universal regulated switch mode with PFC, SRM
Nominal voltage (±10%) 100-240 V @ 50-60Hz
Power fac tor (> 50 0 W ouput) > 0.95
Consumption/current draw @ 115 V @ 230 V
Idle 31.4 W 0.40 A 31.6 W 0. 28 A
Idle (DSP+D) 32.7 W 0.45 A 31.8 W 0.29 A
1/8 Max Outp ut Power @ 4  442 W 4.2 A 438 W 2.39 A
1/4 Max Output Power @ 4  878 W 8.02 A 849 W 4.41 A
AC Mains co nnector
IEC C20 inlet (20 A max)
region-specic power cord provided
Thermal
Operating temperature -10° - 35° C / 14° - 95° F
Cooling
Fan, continuously variable speed,
temperature controlled, front to rear a irow
Thermal dissipation @ 115 V @ 220 V
Idle 107.2 BTU/h 27.0 kcal/h 107.9 BTU/h 27.2 kcal/h
Idle (DSP+D) 111.6 BT U/ h 28.1 kcal/h 112.0 BTU/h 28.2 kcal/h
1/8 Max Outp ut Power @ 4  484.8 BTU/h 122.2 kcal/h 471.2BTU/h 118.8 kcal/h
1/4 Max Output Power @ 4  949.1 BTU/h 239.3 kcal/h 850.1 BTU/h 214.3 kcal/h
Output Stage
Maximum output power per channel @ 8  600 W
Maximum output power per channel @ 4  600 W
Maximum output power per channel @ 2  800 W
Maximum output power @ 4  Bridged 160 0 W
Maximum output power @ 8  Bridged 120 0 W
Maximum output power @ Hi-Z distributed line 100 V 60 0 W
Maximum output power @ Hi-Z distributed line 70 V 600 W
Maximum unclipped output vol tage @ 8  100 V
peak
Maximum output current 45 A
peak
T he power gure is calculated by driving and loading symmetrically all the channels: uneven loads allow to achieve higher performances.
Quattrocanali 2404 DSP+D
22 | Quattrocanali Series
Page 23
Networking
Standards compliance auto-sensing Fast Ethernet (IEEE 80 2.3u, 100 Mbit /s)
Supported topologies Star
Remote inter face Armonía Pro Audio Suite™
DSP*
AD conver ters
24 Bit Tandem™ @ 48 kHz
125 dB-A Dyna mic Range - 0.005 % THD+N
DA conver ters
24 Bit Tandem™ @ 48 kHz
117 dB-A Dynamic Range - 0.0 03 % THD+N
Sample rate converter
24 Bit @ 44.1 kHz to 192 kHz
140 dB Dynamic Range - 0.00 01 % THD+N
Internal precision 32 bit oating point
Latency 2.5 ms xed latency architecture
Memory/Presets 128 MB (RAM) plus 512 MB ash for presets
Delay 2 s (input) + 100 ms (output) for time alignm ent
Equalizer
Raised-cosine, custom FIR, parametr ic IIR:
peaking, hi/lo-shelving, all-pass,
band-pass, band-stop, hi/lo-pass
Crossover
linear phase (FIR), Butterworth,
Linkwitz-Riley, Bes sel: 6 dB/oct to 48 dB/oct (IIR)
Limiters TruePower™, RMS voltage, RMS cur rent, Peak limiter
Damping control
Active DampingControl™ and
LiveImpedance™ measurement
Audio
Gain 26 dB 29 dB 32 dB 35 dB
Input sensitivity @ 8  2.45 Vrms 1.74 V rm s 1. 22 V rms 0.87 Vrms
Max input level 20 dBu
Frequency Response ( ±0.5 dB , 1 W @ 8 ) 20 Hz - 20 kHz
Crosstalk (1 kHz) typic al -70 dB
S/N (20 Hz - 20 kHz A-Weighted @ 8 ) > 104 dB
Input impedance 20 k bala nced
THD+N (from 0.1 W to Full Power)
< 0.1%
(typical < 0.05%)
DIM (from 0.1 W to Full Power) < 0.0 5%
Slew Rate (input lter bypassed @ 8 ) > 50 V/µs
Damping Factor @ 8 , 20 Hz - 100 Hz > 500
Channel Handling
Number of output channels
4 Hi-Z or Lo-Z
(bridg eable per ch. pair)
Phoenix PC 5/8-STF1-7,62
Number of input channels
Analog 4 Phoenix MC 1,5/12-ST-3,81
Dante™* 4 1 x RJ45
Construction
Dimensions
483 x 44.5 x 358 mm
19.0 x 1.75 x 14.1 in
Weight 6.8 Kg (15 lb)
AC Mains Power
Power supply Universal regulated switch mode with PFC, SRM
Nominal voltage (±10%) 100-240 V @ 50-60Hz
Power fac tor (> 50 0 W ouput) > 0.95
Consumption/current draw @ 115 V @ 230 V
Idle 31.4 W 0.40 A 31.6 W 0.28 A
Idle (DSP+D) 32.7 W 0.45 A 32.8 W 0.29 A
1/8 Max Outp ut Power @ 4  301 W 2.75 A 302 W 1.65 A
1/4 Max Output Power @ 4  556 W 5.47 A 553 W 3.02 A
AC Mains co nnector
IEC C20 inlet (20 A max)
region-specic power cord provided
Thermal
Operating temperature -10° - 35° C / 14° - 95° F
Cooling
Fan, continuously variable speed,
temperature controlled, front to rear a irow
Thermal dissipation @ 115 V @ 220 V
Idle 107.2 BTU/h 27.0 kcal/h 107.9 BTU/h 27.1 kcal/h
Idle (DSP+D) 111.6 BT U/ h 28.1 kcal/h 108.6 BTU/ h 27.3 kcal/h
1/8 Max Outp ut Power @ 4  344.8 BTU/h 86.8 kcal/h 348.2 BTU/h 87.6 kcal/h
1/4 Max Output Power @ 4  532.6 BTU/h 134.0 kcal/h 522.3 BTU/h 131.4 kcal/h
Output Stage
Maximum output power per channel @ 8  300 W
Maximum output power per channel @ 4  300 W
Maximum output power per channel @ 2  400 W
Maximum output power @ 4  Bridged 800 W
Maximum output power @ 8  Bridged 600 W
Maximum output power @ Hi-Z distributed line 100 V 30 0 W
Maximum output power @ Hi-Z distributed line 70 V 300 W
Maximum unclipped output vol tage @ 8  70 V
peak
Maximum output current 33 A
peak
T he power gure is calculated by driving and loading symmetrically all the channels: uneven loads allow to achieve higher performances.
Quattrocanali 1204 Quattrocanali 1204 DSP+D
English | 23
Page 24
Powersoft S.p.A.
Via Enrico Conti, 5
50018 Scandicci (FI) Italy
Tel: +39 055 735 0230 Fax: +39 055 735 6235
Sales & general inquiries: sales@powersoft.it
Application & technical support: support@powersoft.it
Service & maintenance: service@powersoft.it
Compliance requests: compliance@powersoft.it
powersoft-audio.com
Loading...