Data are subject to change without notice.
For latest update please refer to the English
online version available on www.powersoft-audio.com.
Page 3
Table of contents
1. Important safety instructions 10
2. Ottocanali Series 11
2 : 1.Welcome 11
2 : 2.Unpacking & checking for shipping damage 11
2 : 3.Disposal of the packaging material 11
2 : 4.List of image panels 11
3. Installation 12
3 : 1.Location 12
3 : 2.Cooling 12
3 : 3.Cleaning 12
3 : 4.AC mains supply 12
3 : 5.Energy save 13
3 : 6.Remote ON/OFF (standby mode) 13
3 : 7.Precautions regarding installation 13
4. Connections 14
4 : 1.Signal grounding 14
4 : 2.Analog audio input connections 14
4 : 2.1. AUX SEL. IN: Analog input selection 14
4 : 2.2. PWS OUT: Built-in auxiliary power supply 14
4 : 3.Digital audio input connections 14
4 : 3.1. Input selection and Backup policy 14
4 : 4.Ethernet connections 14
4 : 5.Output connections 15
4 : 5.1. Hi-Z 70V/100V operations 15
4 : 6.GPO - Alarms 15
4 : 6.1. Pilot tone monitoring 15
4 : 6.2. Output load monitoring 15
5. Attenuators 16
6. LED chart 16
7. Firmware update 16
8. Networking 17
8 : 1.IP addressing 17
8 : 1.1. IP Addressing troubleshooting 17
8 : 2.Dante™ networking 17
8 : 2.1. Redundant network configuration 17
9. Armonía Pro Audio Suite 18
9 : 1.Signal routing and DSP architecture 18
9 : 2.Purposed workflow 18
10. Warranty and assistance 19
10 : 1.Warranty 19
10 : 1.1. Return of Goods 19
10 : 1.3. Repair or replacement 19
10 : 1.4. Cost and responsibility of transport 19
10 : 2.Assistance 19
OTTOCANALI | 3
Page 4
A
482
442
Ottocanali
12K4
DSP+D
76.2
88.2
365.5
382
B
1. Grip the outermost left hand side panel
and tilt it on its inner edge;
2. Carefully slide the panel and remove
the anti-dust lter.
1
2
4 | OTTOCANALI
Page 5
C
Ottocanali
12K4
DSP+D
ABECD
CH 1-2
CH 3-4
CH 5-6
CH 7-8
OFF
ON
ENERGY
SAVE
PWS OUT
ONOFF
Front
A. 24 VDC PWS OUT switch
B. Energy save DIP switches
C. Input attenuators (channels 1 to 8)
D. Multifunction LEDs (channels 1 to 8)
E. Air vent
2 3 4 5 6 7 81
Ottocanali 12K4
Ottocanali 8K4
Ottocanali 4K4
D
123
Rear
1. On/off power switch and
AC mains IEC C20 inlet
2. Fan
3. Audio outputs (channels 1-4)
4. Audio outputs (channels 5-8)
5. Audio inputs: LINE (ch. 1-8)
6. Audio inputs: AUX (ch. 1-8)
7. Fan
8. GPO - Alarms channels 1-4
9. GPO - Alarms channels 5-8
10. Remote off switch
11. Disabled (remote on switch)
12. 24 V
DC
13. AUX SEL. IN input selector
14. Multi function DIP switch ch. 1-2
(impedance, voltage, filter)
PWS OUT
CLASS3
WIRING
100V
hi-Z
70Hz
70V
lo-Z
35Hz
100V
hi-Z
70Hz
70V
lo-Z
35Hz
4
HPF On
HPF Off
HPF On
HPF Off
15. Multi function DIP switch ch. 5-6
(impedance, voltage, filter)
16. Multi function DIP switch ch. 7-8
(impedance, voltage, filter)
17. Multi function DIP switch ch. 3-4
(impedance, voltage, filter)
8765
CH1CH2CH3CH4
CH1CH2CH3CH4
CH5CH6CH7CH8
CH5CH6CH7CH8
4 NCNO 3 NC NO 2 NCNO 1 NC NO
8 NCNO 7 NC NO 6 NCNO 5 NC NO
9
1012111314151617
OTTOCANALI | 5
Page 6
E
Ottocanali
12K4
DSP+D
Ottocanali 12K4 DSP+D
Ottocanali 8K4 DSP+D
Ottocanali 4K4 DSP+D
ABDEFGCJH
CH 1-2
CH 3-4
OFF
ON
ENERGY
SAVE
PWS OUT
ONOFF
Front
A. 24 VDC PWS OUT switch
B. Energy save DIP switches
C. USB port
D. Callback to Armonía
E. Soft reset pushbutton
F. Hard reset pushbutton
G. Firmware update pushbutton
H. Output attenuators (speakers A to H)
I. Multifunction LEDs (channels 1 to 8)
J. Air vent
CALLSOFT RESET HARD RESET FW UPDATE
CH 5-6
CH 7-8
B C D E F G HA
I
F
123
1. On/off power switch and
Rear
AC mains IEC C20 inlet
2. Fan
3. Audio outputs (channels 1-4)
4. Audio outputs (channels 5-8)
5. Audio inputs: LINE (ch. 1-8)
6. Audio inputs: AUX (ch. 1-8)
7. Fan
8. GPO - Alarms channels 1-4
9. GPO - Alarms channels 5-8
10. Ethernet port / Dante™ primary
11. Ethernet port / Dante™ secondary
12. Remote off switch
13. Remote on switch
14. 24 V
15. AUX SEL. IN input selector
16. Multi function DIP switch ch. 1-2
(impedance, voltage, filter)
17. Multi function DIP switch ch. 5-6
(impedance, voltage, filter)
18. Multi function DIP switch ch. 7-8
(impedance, voltage, filter)
19. Multi function DIP switch ch. 3-4
(impedance, voltage, filter)
PWS OUT
DC
CLASS3
WIRING
100V
hi-Z
70Hz
HPF On
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPFOn
70V
lo-Z
35Hz
HPF Off
4
CH1CH2CH3CH4
CH1CH2CH3CH4
CH5CH6CH7CH8
CH5CH6CH7CH8
1617181911
8765
4 NCNO 3 NC NO 2 NCNO 1 NC NO
8 NCNO 7 NC NO 6 NCNO 5 NC NO
12131415
10
9
6 | OTTOCANALI
Page 7
G H
INPUT
Phoenix MC 1,5/12-ST-3,81 1803675Phoenix PC 5/ 8-STF1-7,62 1777891
OUTPUT (single ended)
I J
GPO
INPUT (link channel pairs)
CH 4
CH 3
CH 2
CH 1
Phoenix MC 1,5/12-ST-3,81 1803675
Bill of connectors
NamePlug
INPUTPhoenix MC 1,5/12-ST-3,81 1803675
OUTPUTPhoenix PC 5/ 8-STF1-7,62 1777891
GPO/ALARMPhoenix MC 1,5/12-ST-3,81 1803675
AUXILIARYPhoenix MC 1,5/4-ST-3,81 1803594
AC MAINSIEC C19
Phoenix MC 1,5/12-ST-3,81 1803675
OUTPUT (bridged)
CH 3-4
CH 1-2
Phoenix PC 5/ 8-STF1-7,62 1777891
OTTOCANALI | 7
Page 8
K
70V
lo-Z
35Hz
HPF Off
100V
hi-Z
70Hz
HPF On
12345678
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Ottocanali
12K4
DSP+D
Low-ZHigh-Z100V70VHPF @ 35 Hz HPF @ 70 Hz
1
2
3
4
5
6
7
•
••
•••
•••
••
•••
•••
100V
70V
hi-Z
lo-Z
2
100V
hi-Z
70Hz
HPF On
1 2 3 4 5 6 7 8
70Hz
HPF On
35Hz
HPF Off
1
1 2 3 4 5 6 7 8
70V
100V
70V
lo-Z
hi-Z
lo-Z
35Hz
HPF Off
5
70Hz
35Hz
HPF On
HPF Off
1 2 3 4 5 6 7 8
100V
70V
100V
70V
hi-Z
lo-Z
hi-Z
lo-Z
3
6
70Hz
35Hz
70Hz
35Hz
HPF On
HPF Off
HPF On
HPF Off
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
100V
70V
100V
70V
hi-Z
lo-Z
hi-Z
lo-Z
4
70Hz
HPF On
1 2 3 4 5 6 7 8
35Hz
HPF Off
7
70Hz
35Hz
HPF On
HPF Off
1 2 3 4 5 6 7 8
L M N
RJ45
1 2 3 4 5 6 7 8
Color code (TIA/EIA-568-B)Pin
ORANGE /
WHITE
ORANGE2
GREEN / WHITE3
BLUE4
BLUE / WHITE5
GREEN6
BROWN / WHITE7
BROWN8
8 | OTTOCANALI
1
Ottocanali
DSP+D
12K4
Mounting brackets
1 RU
44
33
22
1
1 RU
44
33
22
11
5
1
1 RU
Page 9
Regulatory informations
WEEE DirectiveEC Declaration Of Conformity
If the time arises to throw away your product, please recycle all
possible component.
This symbol indicates that when the end-user wishes
to discard this product, it must be sent to separate
collection facilities for recovery and recycling. By
separating this product from other household-type
waste, the volume of waste sent to incinerators or
land-lls will be reduced and natural resources will
thus be conserved.
The Waste Electrical and Electronic Equipment Directive (WEEE
Directive) aims to minimise the impact of electrical and electronic
goods on the environment. Powersoft S.p.A. comply with the
Directive 2012/19/EU of the European Parliament on waste
electrical nance the cost of treatment and recovery of electronic
equipment (WEEE) in order to reduce the amount of WEEE that is
being disposed of in land-ll site.
All of our products are marked with the WEEE symbol; this
indicates that this product must NOT be disposed of with other
waste. Instead it is the user’s responsibility to dispose of their
waste electrical and electronic equipment by handing it over to
an approved reprocessor, or by returning it to Powersoft S.p.A.
for reprocessing. For more information about where you can send
your waste equipment for recycling, please contact Powersoft
S.p.a. or one of your local distributors.
Manufacturer:
Powersoft S.p.A.
via E. Conti 5
50018 Scandicci (Fi)
Italy
We declare that under our sole responsibility the products:
Model Names: Ottocanali 12K4
Are in conformity with the provisions of the following EC
Directives, including all amendments, and with national legislation
implementing these directives:
2014/35/EU Low Voltage Directive
2014/30/EU Electromagnetic Compatibility Directive
2011/65/EU RoHs Directive
2014/53/EU Radio Equipment Directive
The following harmonized standards are applied:
EN 55103-1: 2009 /A1: 2012
EN 55103-2: 2009 /IS: 2012
EN 60065: 2014 /AC: 2016
O
Scandicci,
February 2017
Luca LastrucciManaging Director
For compliance questions only: compliance@powersoft.it
OTTOCANALI | 9
Page 10
Important safety instructions
EXPLANATIONS OF GRAPHICAL SYMBOLS
The triangle with the lightning bolt is used to alert the user to the risk of
electric shock.
1
CAUTION
RISK OF ELECTRICK SHOCK
DO NOT OPEN
The triangle with the exclamation point is used to alert the user to important operating or maintenance instructions.
The CE-mark indicates the compliance with the low voltage and electromagnetic compatibility.
Symbol for earth/ground connection.
Symbol indicating that the equipment is for indoor use only.
Symbol for conformity with Directive 2002/96/EC and Directive
2003/108/EC of the European Parliament on waste electrical and electronic equipment (WEEE).
Do not use the unit at altitudes above 2000 m.
Do not use the unit in tropical environment.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO
OPEN ANY PART OF THE UNIT. NO USER-SERVICEABLE PARTS INSIDE. REFER
SERVICING TO QUALIFIED SERVICE PERSONNEL.
TO COMPLETELY DISCONNECT THIS APPARATUS FROM THE AC MAINS, DISCONNECT THE POWER SUPPLY CORD PLUG FROM THE AC RECEPTACLE.
THE MAINS PLUG OF THE POWER SUPPLY CORD MUST
REMAIN READILY ACCESSIBLE.
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE, DRIPPING OR
SPLASHING LIQUIDS. OBJECTS FILLED WITH LIQUIDS, SUCH AS VASES, SHOULD
NOT BE PLACED ON THIS APPARATUS.
THE UNIT MUST BE INSTALLED IN RACK CABINETS: INSTEAD OF CONNECTING
THE AMPLIFIER TO THE POWER GRID DIRECTLY, PLUG THE AMPLIFIER’S MAINS
CONNECTIONS VIA A SECTIONING BREAKER TO A POWER DISTRIBUTION PANEL
INSIDE THE RACK CABINET.
WHEN THE UNIT IS INSTALLED IN A CABINET OR A SHELF, MAKE SURE THAT IT
HAS SUFFICIENT SPACE ON ALL SIDES TO ALLOW FOR PROPER VENTILATION (50
CM FROM THE FRONT AND REAR VENTILATION OPENINGS).
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A ELECTROTECHNICAL
SKILLED PERSON ACCORDING THE NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT IS SOLD.
WARNING. THIS APPARATUS CONTAINS A NON RECHARGEABLE LITHIUM BATTERY (I.E. CR2032, 3V). THE BATTERY IS NOT INTENDED TO BE REPLACED BY THE
END USER. ONLY THE STAFF OF THE AUTHORIZED SERVICE CENTERS CAN ACCESS AND REPLACE THE BATTE R Y.
WARNING: THE INTERNAL BATTERY SHALL NOT BE EXPOSED TO EXCESSIVE
HEAT SUCH AS SUNSHINE, FIRE OR THE LIKE.
Electrical energy can perform many useful functions. This unit has been engineered and manufactured to ensure your personal safety. But IMPROPER USE CAN
RESULT IN POTENTIAL ELECTRICAL SHOCK OR FIRE HAZARD.
In order not to defeat the safeguards incorporated into this product, observe
the following basic rules for its installation, use and service. Please read these
“Important Safeguards” carefully before use.
Important safety instructions
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this equipment near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat
registers, stoves, or other apparatus (including ampliers) that
produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one
wider than the other. A grounding type plug has two blades
and a third grounding prong. The wide blade or the third
prong are provided for your safety. If the provided plug does
not t into your outlet, consult an electrician for replacement
of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When acart is used,
use caution when moving the cart/apparatus combination to
avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long
periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-supply
cord or plug is damaged, liquid has been spilled or objects have fallen
into the apparatus, the apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
10 | OTTOCANALI
Page 11
Ottocanali SeriesQuick Guide
2
2 : 1.Welcome
Congratulations on buying a Powersoft Ottocanali Series
amplier!
We know you are eager to use your new Ottocanali amplier,
but please take a moment to read this quick guide and the safety
instructions. In case you have any questions, please do not hesitate to contact your dealer or Powersoft.
The Ottocanali Series is specically designed for installation
applications. Ottocanali Series offers smaller dimensions, lighter
weight and the traditionally amazing sound quality and reliability
of all Powersoft products.
The built in PFC (Power Factor Correction) allows awless
worldwide operation with any AC mains voltage, from 100 to 240V;
patented SRM (Smart Rails Management) technology allows
to maximize the efciency of the system and drastically reduce
power consumption at any load and usage condition. This system
automatically alters the rails working voltage according to the instaneous power requirements of the system. A low output power
requires a lower rails voltage which in turn yields lower power
consumption while at the same time guaranteeing lightning fast
switching to full rails voltage when the system requires full power.
Ottocanali Series implements redundant power supplies for
maximum reliability even in case of system fault. In case of damages in one power supply, the other one is capable to maintain
the system up, guaranteeing non-stop functionality even in harsh
conditions.
Ottocanali Series is designed to work with lo-Z (from 2 �) and
with 70V/100V distributed lines: any mixed conguration of low
and high impedance output loads can be realized, making the
Ottocanali Series suitable to all application in installed sound
reinforcement systems.
Ottocanali Series encompasses three models:
Ottocanali 12K4 delivering up to 1500 W per channel at 4�
Ottocanali 8K4 delivering up to 1000 W per channel at 4�
Ottocanali 4K4 delivering up to 500 W per channel at 4�
Each model is available in three versions: normal, with DSP plus
Dante™ and with DSP plus Ethernet connectivity.
2 : 2.Unpacking & checking for shipping damage
Your Powersoft product has been completely tested and inspected before leaving the factory. Carefully inspect the shipping
package before opening it, and then immediately inspect your new
product. If you nd any damage notify the shipping company or
reseller immediately.
The box contains the following:
1x Ottocanali Series amplier.
2x Phoenix MC 1,5/ 4-ST-3,81 - 1803594 plug
6x Phoenix MC 1,5/12-ST-3,81 - 1803675 plug
2x Phoenix PC 5/ 8-STF1-7,62 - 1777891 plug
1x IEC power cord
1x user guide
2 : 3.Disposal of the packaging material
The protective transport packaging has been selected from
materials which are environmentally friendly for disposal and can
normally be recycled.
Rather than just throwing these materials away, please
ensure they are offered for recycling.
2 : 4.List of image panels
A. Mechanical drawings: all dimensions in millimeters
B. Front panel: how to access it
C. Ottocanali Series: Front panel description
D. Ottocanali Series: Rear panel description
E. Ottocanali Series DSP: Front panel description
F. Ottocanali Series DSP: Rear panel description
G. Input connector: wiring (single ended mode)
H. Output connector: wiring (single ended mode)
I. Alarms connector: wiring
J. Input/Output connectors: wiring (bridged mode)
K. Output load DIP switch congurations
L. RJ45 Ethernet wiring (Color code TIA/EIA-568-B)
M. Air ow and mounting brackets
N. Rack mounting constraints
O. Regulatory information
OTTOCANALI | 11
Page 12
Installation
3
3 : 1.Location
Ottocanali Series ampliers are meant to be installed into rack.
In order to limit the risk of mechanical damages, the ampliers must
be xed to the rack using both frontal and rear mounting brackets.
We recommends to use eight M6 or 12-24 UNC-2B screws for
threaded holes or cage nuts.
The AC mains connection of the units should be connected to
a proper circuit breaker (refer to §3 : 4.AC ma ins supply for more
details).
Install this amplier as far as possible from radio tuners and TV
sets. An amplier installed in close proximity of such equipment
may experience noise or generic performance degradation.
Placing and using the amplier for long periods of time on heat
generating sources will affect its performance. Avoid placing the
amplier on heat generating sources.
3 : 2.Cooling
Install the amplier in a well-ventilated location: the ventilation
openings must not be impeded by any item such as newspapers,
tablecloths, curtains, etc; keep a distance of at least 50 cm from
the front and rear ventilation openings of the amplier.
All Powersoft ampliers implement a forced-air cooling system
to maintain low and constant operating temperatures. Drawn by
the internal fans, air enters from the front panel and is forced over
all components, exiting at the back of the amplier.
The amplier’s cooling system features “intelligent” variablespeed DC fans which are controlled by the heatsink temperature
sensing circuits: the fans speed will increase only when the temperature detected by the sensors rises over carefully predetermined
values. This ensures that fan noise and internal dust accumulation
are kept to a strict minimum.
Should however the amplier be subject to an extreme thermal
load, the fan will force a very large volume of air through the heat
sink. In the extremely rare event that the amplier should dangerously overheat, sensing circuits shut down all channels until
the amplier cools down to a safe operating temperature. Normal
operation is resumed automatically without the need for user
intervention.
Ottocanali Series ampliers can be stacked one on top of the
other due to the efcient cooling system they are equipped with.
There is however a safety limit to be observed: in case a rack
with closed back panels is used, leave one rack unit empty every four
installed ampliers to guarantee adequate air ow (see Panel N, p.
14).
3 : 3.Cleaning
Always use a dry cloth for cleaning the chassis and the front
panel. Air lter cleaning should be scheduled according to the
dust levels in the amplier’s operating environment.
Disconnect the AC mains source before
attempting to clean any part of the amplifier
In order to clean the vent lters you need to remove the front
cover: never attempt to open any other part of the unit.
1. Firmly grip the outermost silver colored panel and pull outwards
at an angle, as if opening a door (seePanel B, p. 7).
2. Carefully slide the metal panel away from the chassis. When
the front panel is removed, the air lter (looking like a shiny
black plastic sponge) will be exposed.
You may use compressed air to remove the dust from lters, or
wash it with clean water: in the latter case ensure that the lter is
dry before reassembly.
3 : 4.AC mains supply
Ottocanali Series ampliers implement two universal redundant switching mode power supplies operating in the range from
100 V
with power switch: the approved power cord is provided (see FIG. 1).
up to 240 VAC ±10%.
AC
AC mains connection is in the rear panel through the IEC C20 inlet
FIG. 1: AC mains connection.
AC mains connections must be performed
only by professional or qualified personnel
according to local electrical authorities guidelines.
This device must be powered exclusively by
earth connected mains sockets in electrical
networks compliant to the IEC 364 or similar rules.
12 | OTTOCANALI
Powersoft suggests to plug
the Ottocanali to a 32 A rating,
C or D curve, 10 kA sectioning breaker.
Page 13
3 : 5.Energy save
3 : 7.Precautions regarding installation
Energy save capabilities can be activated for each channel
pair. Four DIP switches are located on the left hand side of the
front panel (see Panel C, p. 8 and Panel E, p. 10): in order to
activate the Energy save mode for channel pair set the switches in
the bottom position.
When the Energy save mode is activate on a channel pair, the
Ottocanali enters a low power consumption idle state when no
signal activity is detected for more than 4 seconds. Normal operation is resumed in a matter of milliseconds when an incoming
signal is detected on the channel pair.
TAB. 1 shows the power consumption in idle mode for non-
DSP amplifers, when the Energy save is either enabled or disabled
on all channels.
115 V
mains230 VAC mains
Energy
Save
OFF0.90 A52 W 103.5 VA 0.84 A58 W193 VA
Current
ON0.65 A30 W75 VA0.76 A35 W175 VA
AC
Real
Power
Apparent
Power
Current
Real
Power
Apparent
Power
TAB. 1: Idle consumption.
Note: in caswe a pilot tone is used for checking system integrity
and line faults, the Ottocanali amplier would continuously detects
a stationary signal that prevents the the idle mode. In this condition the Energy save will never activate.
WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK
This device must be powered exclusively by earth connected
mains sockets in electrical networks compliant to the IEC
364 or similar rules.
Install the unit into rack cabinet.
A sectioning breaker between the mains connections and the
amplier should be installed inside the rack cabinet.
Properly t the AC mains plug to the amplier inlet.
Before powering this amplier, verify that the correct voltage
rating is being used.
Verify that your mains connection is capable of satisfying the
power ratings of the device.
Do not use this amplier if the electrical power cord is frayed
or broken.
Output terminals are hazardous: wiring connection to these
terminals require installation by an instructed person and the
use of ready-made leads.
Take care to lock the output terminal before switching the
device on.
To avoid electrical shock, do not touch any exposed speaker
wiring while the amplier is operating.
3 : 6.Remote ON/OFF (standby mode)
Remote ON/OFF is available throurgh the proper terminals in
the rear panel: in non-DSP Ottocanali (see Panel D, p. 8) by
switching 24 V
OFF connector, the amplier can be remotely toggle between
standard operating and the standby modes.
When a 24 V
switches to standby mode.
When the 24 V
plier switches back on as per normal boot up operation.
In order to remotely toggle between standard operating and
the standby modes, the AC mains power must be active and the
mains button switched on.
±10% voltage (10 mA max) applied to the REM
DC
voltage is applied to REM OFF, the amplier
DC
voltage is removed from REM OFF, the am-
DC
Do not spill water or other liquids into or on the amplier.
No naked ame sources such as lighted candles should be
placed on the amplier.
Do not remove the cover. Failing to do so will expose you to
potentially dangerous voltage.
The manufacturer cannot be held responsible for damages
caused to persons, things or data due to an improper or
missing ground connection.
Contact the authorized service center for ordinary and extra-
ordinary maintenance.
It is absolutely necessary to verify these fundamental
requirement of safety and, in case of doubt, require
an accurate check by qualified personnel.
OTTOCANALI | 13
Page 14
Connections
23456781
PWSOUT
ENERGY
SAVE
ON
OFF
CH 1-2
CH 3-4
CH 5-6
CH 7-8
ONOFF
Make sure the power switch is off before attempting to make
any input or output connections.
By using good quality input and speaker cables, the likelihood
of erratic signal behavior is reduced to a minimum. Whether you
make them or buy them, look for good quality wires, connectors
and soldering techniques.
4 : 1.Signal grounding
PWS OUT
PWS OUT LINE input
switch
OFFACTIVE—
ON—ACTIVE
FIG. 3: Manual procedure to switch from LINE to AUX.
4 : 3.Digital audio input connections
4
AUX
input
There is no ground switch or terminal on the Ottocanali Series
ampliers. All shield terminals of input connections are directly
connected to the chassis. This means that the unit’s signal grounding system is automatic. In order to limit hum and/or interference
entering the signal path, use balanced input connections.
In the interests of safety, the unit MUST always operate with
electrical safety earth connected to the chassis via the dedicated
Protective Earth
wire.
4 : 2.Analog audio input connections
Ottocanali Series ampliers implements two analog input connections per channel: LINE and AUX input. Input selection is made
via software or through the AUX SEL. IN switch (see §4 : 2.1. AUX
SEL. IN: Analog input selection).
Analog input is provided by means of four Phoenix MC 1,5/12ST-3,81 1803675 connectors (see Panel D, p. 8 and Panel F,
p. 10), two for LINE input (channels 1-to-4 and 5-to-8) and two
dedicated to the AUX input (channels 1-to-4 and 5-to-8). Signal
polarity of analog input connections is shown in Panel G, p. 12.
4 : 2.1. AUX SEL. IN: Analog input selection
Ottocanali Series ampliers can switch from analog LINE inputs to AUX inputs when a constant voltage in the 12 V
range is applied to the AUX SEL. IN connector (see Panel D, p.
8 and Panel F, p. 10). When this voltage is removed from
the AUX SEL. IN, the unit switches back from AUX inputs to LINE
inputs.
FIG. 2: AUX SEL. IN and PWS OUT connector and wirings.
4 : 2.2. PWS OUT: Built-in auxiliary power supply
The PWS OUT connector provides a 24VDC – symmetrical with
respect to ground (0.2 A max) – when enabled by the toggle switch
on the front panel (see Panel C, Panel D, p. 8 and Panel E,
Panel F, p. 10).
By wiring the PWS OUT connector to the AUX SEL. IN as
shown in FIG. 3, the front panel PWS OUT switch is enabled to
toggle between analog LINE inputs and AUX inputs: this provides
an additional manual procedure to switch from analog LINE to
AUX and vice versa.
14 | OTTOCANALI
to 30 VDC
DC
Digital input is supported via Dante™ standard protocols in
Dante equipped devices.
In Ottocanali DSP+D ampliers, Dante connectivity is supported via two Ethernet ports located on the rightmost side of the
rear panels (see Panel F, p. 10). Fast Ethernet (IEEE 802.3u,
100 Mbit/s) and Gigabit Ethernet (IEEE 802.3ab, 1Gbit/s) network
protocols are supported; Cat5e or Cat6 standard UTP twisted pair
cables shall be used for connections up to 100 meters (328 ft).
Ethernet cabling must comply to TIA/EIA-568-B and adopt the
T568B scheme pinout, as shown in Panel L, p. 14.
4 : 3.1. Input selection and Backup policy
In Ottocanali DSP+D ampliers it is possible to select among
three input signal sources per channel: analog (either LINE or AUX)
and two Dante streams (streams 1-to-8 and 9-to-16).
FIG. 4: Ottocanali DSP+D: Input selection and backup policy.
Armonía Pro Audio Suite provides an interface to select the
proper input source and manage input gain and delay of analog and
digital sources, in order to compensate transmission latency and
levels (see FIG. 4).
Furthermore Ottocanali DSP+D ampliers implement a backup
policy aimed to improve reliability against signal fault. By assigning
a bus priority to the three different input sources – analog and two
Dante streams – per channel, the system is able to automatically
switch to a reliable input connection in case of signal drop or pilot
tone mismatch.
4 : 4.Ethernet connections
Ottocanali DSP+D ampliers can be remotely controlled via an
Ethernet connection through a personal computer and Powersoft
Armonía Pro Audio Suite software. Powersoft recommend the use
of Ethernet Cat5 straight through – patch – cables with pin/pair assignments TIA/EIA-568-B, i.e. T568B, as shown in Panel L, p. 14.
Page 15
4 : 5.Output connections
CLASS 3 WIRING
CLASS3
and the use of ready made leads. Take care to secure the output
terminal before switching the device on.
single-ended wirings for lo-Z loudspeaker and Hi-Z distributed
lines connections are shown in Panel H, p. 12. Bridge-tied
connection of lo-Z loudspeaker is supported on adjacent channel
pairs 1-2, 3-4, 5-6 and 7-8; inputs must be physically paralleled as
shown in Panel J, p. 12.
loads can be realized: in order to set the load conguration, each
channel is provided by four DIP switches (refer to Panel K, p.
13). Ottocanali Series is congured to drive Lo-Z loads (Panel
K#1) by factory default.
70V/100V (Hi-Z) distributed line of louspeakers. In order to connect
any channel’s output to a 70V/100V line, the rear panel DIP switch
corresponding to the channel must be correctly set as reported in
Panel K, p. 13.
Filter) when the amplier is set to drive a distributed line to prevent loudspeaker transformer saturation which can considerably
degrade sound performance. The HPF can be activated by means
of the DIP switch corresponding to the channel (see Panel K, p.
13): two cutting frequency are available 35 Hz and 70 Hz.
Output terminals are hazardous: wiring connection to these terminals require installation by an instructed person
Output connectors are Phoenix PC 5/ 8-STF1-7,62 1777891:
Any mixed conguration of low and high impedance output
4 : 5.1. Hi-Z 70V/100V operations
Any channel of an Ottocanali Series amplier can drive
Powersoft recommends to use the built-in HPF (High Pass
4 : 6.1. Pilot tone monitoring
Thanks to the built-in DSP, the Ottocanali DSP+D ampliers
implement pilot tone detection and alert. Detecting and alerting
features are available for both input and output pilot tones on each
channel.
The detection of a mismatch in the input pilot tone parameters
(frequency and voltage level) can be used to trigger the backup
policy (refer to §4 : 3.1. Input selection and Backup policy) and
activate an alert through the general purpose output switch.
The output pilot tone detection relies on an external signal
passing through the amplier or the internal post DSP pilot tone
generator (see FIG. 4); in both cases any mismatch between the
detected signal and the set thresholds triggers the general purpose output switches.
4 : 6.2. Output load monitoring
Through Armonía Pro Audio Suite software it is possible to set
the thresholds on the load impedance, at given frequency, that
trigger the general purpose output of any channel of the ampliers
with DSP (see FIG. 5).
4 : 6.GPO - Alarms
The Ottocanali’s GPO – general purpose output – system
implements triggering signals to broadcast alarms.
Ottocanali Series provides a pair of paralleled general purpose
output connections per channel: one Normally Open
one Normally Closed
The connections are available on the back panel via two 12pin Phoenix MC 1.5/12-ST-3.81 1803675 connectors for channels
1-to-4 and 5-to-8: see Panel I, p. 12 for wirings.
These contacts are used to report potentially dangerous
faults or generally unsafe operation conditions by toggling alarm
switches relative to the following events:
No AC mains (i.e. system shutdown);
Thermal stress: the system temperature reaches 70°C, ther-
mal protections are going to be engaged;
Short circuit in output wiring: either the loudspeaker or the
line is in short;
DC presence at the output: a continuously stationary signal
is present at output terminals.
Ottocanali DSP feature further monitoring on pilot tone and
output load: the GPO monitoring interface in Armonía Pro Audio
Suite software is accessible through the GPO button
located at the top right corner in the dashboard of the
selected Ottocanali DSP amplier (refer to Section 9
“Armonía Pro Audio Suite”).
NC.
NO and
FIG. 5: GPO: System monitoring interface.
OTTOCANALI | 15
Page 16
AttenuatorsFirmware update
B C D E F G HA
CALLSOFT RESET HARD RESET FW UPDATE
PWS OUT
ENERGY
SAVE
ON
OFF
CH 1-2
CH 3-4
CH 5-6
CH 7-8
ONOFF
B C D E F GHA
CALLSOFT RESET HARD RESET FW UPDATE
PWS OUT
ENERGY
SAVE
ON
OFF
CH 1-2
CH 3-4
CH 5-6
CH 7-8
ONOFF
5
The row of potentiometers in the front panel behave differently
on non-DSP ampliers and Ottocanali DSP+D ampliers:
In non-DSP Ottocanali ampliers, the potentiometers act
as trimmers on the input level (see Panel C, p. 8): the
input signal is muted when the trimmer is completely turned
counterclockwise; on the other hand, no attenuation is applied when the trimmer is completely turned clockwise.
In Ottocanali DSP the potentiometers attenuate the speakers
gain (see Panel E, p. 10): they modify the overall gain applied to the group of ways belonging to the selected speaker.
The amount of gain attenuation (External gain) is shown in
Armonía Pro Audio Suite.
7
Firmware updates for Ottocanali DSP+D can be loaded via the front USB port. Updated releases of the Ottocanali DSP rmware are available on the Armonía forum
(http://www.powersoft-audio.com/en/armonia-forum).
The package contains the rmware update le whose name is
in the form:
update-version#-model.bin
(e.g. update-1.6.0.10-8ch.bin): store the rmware update le into a
USB storage device and follow these instructions:
1. Switch the amplier on and wait for the completion of the
boot sequence.
2. Plug the USB storage device with the rmware update le to
the USB port in the front panel of the amplier.
LED chart
6
Color
RED
YELLOW
GREEN
GREEN
GREEN
GREEN
GREEN
1
Even if only one channel causes thermal overload, all channels are muted and all red
LEDs are on: normal operating is restored when the temperature falls under the thermal
warning threshold.
2
Even if only one channel causes thermal warning, all yellow LEDs are on: thermal pro-
tections are engaged.
3
Only available in Ottocanali DSP.
Signal
metering
ClippingSOLID ON
-6dBSOLID ON
-12dB——
-24dB——
signal presence
(-60dBV)
—SOLID ONChannel ready
—BLINKINGChannel muted
—BLINKINGAUX inputs are selected
LightingDescription
——
TAB. 2: Front panel LEDs chart.
Warnings
System temperature above
System temperature above
80°C1
(all channels muted)
70°C2
(thermal warning)
3
3. Keep pressed the FW UPDATE pushbutton until thefront
LED bars start blinking.
USB Key in
4. The update process lasts in 3-5 minutes. At the end the
system reboots and it is possible to extract theUSB storage
device.
16 | OTTOCANALI
Page 17
Networking
8
Ottocanali DSP+D ampliers support linear daisy-chain, star
and loop network topologies; in a daisy-chained network the PC
with Armonía Pro Audio Suite must always be at one end of the
chain.
Be aware that daisy-chaining does not guarantee reliability
in production environment, since any fault may yield to network
sectioning and lost of system control.
When efciency and reliability are paramount, a redundant network topology is advisable. In order to exploit the Dante features,
star and open daisy-chain network topology are allowed.
8 : 1.IP addressing
Factory default network settings are DHCP/AutoIP,
inorder for the amplier platform to self-congure when connected
to an existing LAN or PC. Fixed IP policy can also be adopted and
congured through Armonía Pro Audio Suite.
If a DHCP server is not active within the network, the amplier platform initiates a stateless address auto-conguration (i.e.
Zero-conguration networking methodology – Zeroconf): it self
assigns a local numeric network address (of the type 169.254.x.y
– 172.31.*.* for the secondary network ifpresent– with a subnet
mask 255.255.0.0) and automatically distributes and resolves the
hostnames of networked devices. For setting a static IP address
please refer to the Armonía Pro Audio Suite user guide.
8 : 1.1. IP Addressing troubleshooting
When connecting the Ottocanali DSP+D to a network environment it may happen that Armonía Pro Audio Suite does not
discover or import the amplier.
Usually this is a problem of IP addressing: both Armonia and
the Ottocanali DSP must belong to the same subnet. If a DHCP
server is present on the network and a Ottocanali DSP amplier is
in AUTO IP, networking may become unstable.
As a rule of thumb, turn the DHCP server
on before connecting the amplifiers.
IP addressing of an Ottocanali DSP+D amplier is established
during the bootstrap: when the Ottocanali DSP amplier discovers
a DHCP server on the network during the startup, it negotiates
the networking parameters. If the Ottocanali DSP does not reveal
a DHCP server on the network during the startup it set itself in
AUTO IP mode.
8 : 2.Dante™ networking
The Dante equiped models of Ottocanali DSP+D amplier
support Dante redundant networking via the two Rj45 ports on
the rear panel:
Primary/ETH1 is the Primary network port;
Secondary/ETH2 is the Secondary network port.
Dante connectivity is always supported on the Primary/ETH1
Gigabit Ethernet port; the Secondary/ETH2 Gigabit Ethernet port
offers continuity of operation when a parallel redundant network
is established.
In order to implement a Dante network, a computer running
Dante Controller have to be used. Dante Controller is a software
application that manages devices on the network. Ottocanali
DSP+D ampliers are automatically discovered and displayed in
Dante Controller with the default identier
8K4-71520).
Dante networks will almost always require at least one network
switch. Redundant infrastructures may require multiple switches.
For maximum reliability, network switch shall:
be Rated for Gigabit Ethernet;
be Non-blocking;
have Quality of Service (QoS) with at least four queues;
have Diffserv (DSCP) QoS with strict priority;
have EEE (Energy efcient ethernet) switched off.
For detailed information on setting up a switch, please refer to
the manufacturer’s documentation.
8 : 2.1. Redundant network configuration
Dante Redundancy can be set up and used between any
supporting Dante-enabled audio equipment: it works by using
two completely independent and separate networks, the Primary
Network and the Secondary Network.
To setup and use Dante Redundancy, connect the Ottocanali DSP+D amplier and other redundant Dante-enabled audio
equipment using duplicate Gigabit switches and Ethernet cables.
Connect your computer running Dante Virtual Soundcard and
Dante Controller, and other non-redundant Dante-enabled audio
equipment to the Primary Network.
The primary and secondary networks MUST NOT be interconnected at any point. Make sure any computer is set to automatically congure its IP address.
MODELNAME-SERIAL
(e.g.
OTTOCANALI | 17
Page 18
Armonía Pro Audio Suite
9
Armonía Pro Audio Suite is the default conguring interface
that allows system setting and customization of the Ottocanali
DSP+D ampliers.
Armonía can be installed on a PC running Windows (XPSP3
and higher). Freely download Armonía Pro Audio Suite from the
Armonía forum:
http://www.powersoft-audio.com/en/armonia-forum
Ottocanali DSP amplifers can connect to the PC running Armonía through a Fast Ethernet connection. In order to start remote
operation, the device must be discovered and imported into the
Armonía Workspace. Click on the Discover button in the Remote
entities windows, or select it from the Model list and drag it into
the Armonía Workspace.
The callback button – located on the front panel of the amplier – allows you to highlight the presence of the amplier into the
Armonía Workspace.
Once connected to Armonía Pro Audio Suite a double click on
the amplier icon in the Workspace will open the amplier dashboard. Here it is possible to access and congure all the features of
the Ottocanali DSP.
Advanced processing. This allows you to optimize levels
and shape the sound of the input signals. Gain and polarity
adjustment, asymmetric raised-cosine full parametric lters,
delay and mute are available on each channel routed to the
speaker section.
Speaker equalization. Designed to manage the conguration
presets for multi-way systems, it implements FIR and IIR full
parametric lters.
Speaker routing. Once properly grouped, the output chan-
nels are presented to the matrix as speakers – asingle row
representing a speaker (actually group of ways) – allowing a
high grade of granularity in signal processing.
Output processing. This allows ne tuning of output signals,
aiming to optimize power delivering and loudspeaker performance. It provides gain and polarity adjustment, IIR and
FIR full parametric lters, delay, mute, limiting and damping
control on each output channel.
9 : 2.Purposed workflow
Once the loudspeaker layout has been dened, we suggest a
bottom-up conguration procedure that starts from the conguration of the transducers layout and raises toward the input selection
and the denition of the backup policy.
Shortly, the main steps to follow are:
FIG. 6: Armonía Pro Audio Suite.
9 : 1.Signal routing and DSP architecture
Signal processing on Powersoft Ottocanali DSP ampliers
accomplishes multiple functions that affect the audio signal before
power amplication; the main adjustements include gain, polarity,
delay, limiting and signal equalization; some processing are related only to particular stages, such as limiting and damping control
that are implemented on the output section only, or input priority
assignment available in the input section.
The processing architecture is composed of six sections:
Input source selection. The input section allows you to
manage input gain and delay of analog and digital sources,
in order to compensate transmission latency and levels. Furthermore the Ottocanali DSP+D implement a backup policy
aimed to improve reliability against signal fault.
Matrix. The innovative routing engine of Ottocanali DSP
allows any input to be routed to any output. The Matrix
implements a non-boolean rooting architecture allowing free
channel assignment and level adjustment.
1. Set Lo-Z and Hi-Z loads and lters on output channels.
2. Load the loudspeaker presets or manually congure the
loudspeaker layout (grouping output channels, crossovering,
limiting, speaker processing, etc.).
3. Dene the routing path and the levels of the signals from the
input channels to the active output channels (matrix).
4. Select the signal source from the input connections and
dene the backup policy (input source selection).
5. Dene GPO assignment and alarms thresholds.
18 | OTTOCANALI
Page 19
Warranty and assistance
10
10 : 1.Warranty
Powersoft guarantees its manufactured products to be free from
defective components and factory workmanship for a period of time
starting from the date of purchase printed on Powersoft’s (or any of
its Authorized Dealer’s) invoice to the end customer. The standard
warranty period are:
51 months for racks ampliers.
12 month for amplier modules.
All warranty repairs and retrots must be performed at Powersoft facilities or at an Authorized Service Center at no cost for the
purchaser. Warranty exclusion: Powersoft’s warranty does not cover
product malfunctioning or failure caused by: misuse, abuse, repair
work or alterations performed by non-authorized personnel, incorrect connections, exposure to harsh weather conditions, mechanical
damages (including shipping accidents), and normal wear and tear.
Powersoft will perform warranty services provided that the product is
not damaged during transportation.
10 : 1.1. Return of Goods
Goods can be returned to Powersoft only after they have been
granted a Return Merchandise Authorization (RMA) number to be
attached to the external packaging. Powersoft (or its Authorized
Service Center) has the right to refuse any returned good without
a RMA number.
10 : 1.2. Repair or replacement
Powersoft reserves the right to repair or replace any defective
goods covered by product warranty at its sole discretion and as
it deems best.
10 : 1.3. Cost and responsibility of transport
The purchaser (or end user/customer) is solely responsible
for all transportation costs and risks associated with sending
warranty covered goods to Powersoft or its Authorized Service
Center. Powersoft will assume full responsibility and cover all
costs incurred to send the goods back to the purchaser (or end
user/customer).
10 : 2.1. Drop off at a
Powersoft Authorized Service Centre near you
Find a Powersoft Authorized Service Centre from the list.
Take a note of each serial number of the units to be returned.
Completely ll out the defect report form for each unit to be
returned.
Send the completed defect report form to the following e-mail
addresses marco.mannucci@powersoft.it (Customer care
manager) service@powersoft.it (Service Team).
After having applied the aforementioned procedure, the local
service manager will provide the shipment details and the product’s warranty status.
10 : 2.1.1. In-Warranty repairs:
The service repair will be free of charge for the customer.
10 : 2.1.2. Out of Warranty Issues
The service costs are calculated on the local rate applied from
the service centre and supervised by the Powersoft HQ
The repair time has been set from the Powersoft HQ and it’s
equally applied in all the authorized service centre
The unit will be evaluated by a technician, and the ser-
vice centre will provide the customer with the estimated costs. The repair will only take place once
the customer has approved the estimated costs.
The customer will pay the shipping charges once the repair
has been completed, depending on the countries’ standard
procedures.
For any enquiries please contact Powersoft Customer care
service@powersoft.it
10 : 2.2. Shipping the product to
Powersoft S.p.a. for Factory service centre
Take a note of each serial number of the units to be returned.
Fill out completely the defect report form for each unit to be
returned.
Send the completed defect report form to the following email
address:
service@powersoft.it
10 : 2.Assistance
There are no user-serviceable parts in the amplier. Refer to
qualied technical personnel for servicing. In addition to having
an in-house service department, Powersoft supports a network of
Authorized Service Centers. If your amplier needs repair, contact
your Powersoft dealer (or distributor). You can also contact the
Powersoft Technical Service department to obtain the location of
the nearest Authorized Service Center.
Powersoft offers two options for product repair:
Drop off at a Powersoft Authorized Service Centre near you.
Ship the product to Powersoft S.p.a. for Factory Service.
After having applied the aforementioned procedure, you will
receive an Email containing the Return Merchandise Authorization
(RMA form) for each unit returned.
All returned Powersoft units must be shipped to the following
address:
Powersoft spa
Factory service centre
Via Enrico Conti N. 13 – 15
50018 Scandicci (FI)
Italy
Phone +39 (055) 7350230 Option 2
Email: service@powersoft.it
OTTOCANALI | 19
Page 20
Contact Powersoft Factory service centre
Phone +39 (055) 7350230 Option 2
Email: service@powersoft.it
Phone Support Hours
Monday - Friday 8.30 AM to 5.30 PM Europe time
10 : 2.2.1. Shipment from NON-CE countries
When shipping from non-CE (European Community) countries,
follow the procedure described in the TEMPORARY EXPORTATION / IMPORTATION PROCEDURE.
Important Note:
If the RMA# is not displayed anywhere on the outside of the
box, the shipment will be rejected and sent back to the customer.
If the returned goods from NON-CE countries do not follow the
aforementioned guidelines, the package will be rejected and sent
back to the customer.
10 : 2.3. D.O.A. Procedure
In case of a D.O.A. (Dead On Arrival) product, we kindly request the customer to contact the local dealer where the product
was purchased or the Factory service centre, mentioning the serial
number of the faulty unit.
D.O.A. unit will be replaced completely without any additional
charges!
Important Note: Do not tamper with or operate the D.O.A. unit
in any ways in order to avoid any warranty issue.
Powersoft S.p.a declines any D.O.A warranty service if the
returned unit has been tampered with or misused by the customer.
20 | OTTOCANALI
Page 21
Ottocanali 12K4
Ottocanali 12K4 DSP+D
Specifications
Channel Handling
Number of output channels
Number of input channels:
Analog*
Dante™**16 (2x RJ45 redundant)
LINE8 (2x Phoenix MC 1,5/12-ST-3,81)
AUX8 (2x Phoenix MC 1,5/12-ST-3,81)
Lo-Z (bridgeable per ch. pair) /
Hi-Z (2x Phoenix PC 5/ 8-STF1-7,62)
8 mono
Audio
Gain (dB/voltage)32 dB / x40 V
Frequency Response ( ±0.5 dB, 1 W @ 4 Ω)20 Hz - 20 kHz