powersoft Mezzo Series, Mezzo 322, Mezzo 324, Mezzo 602 A, Mezzo 602 AD User Manual

...
Page 1
Mezzo Series
USER GUIDE
Serie Mezzo / Mezzo-Serie / Mezzo Série
Serie Mezzo / Série Mezzo
سلسلة Mezzo / Mezzo シリーズ
Mezzo系列
GUIDA UTENTE / BENUTZERHANDBUCH / MODE D'EMPLOI
GUÍA DEL USUARIO / GUIA DE USARIO
دليل المستخدم / ユ ー ザ ー ガ イド
快速指南
©2019 Powerso
DO000239.1 R0
Keep this manual
for future reference
Page 2
CLASS3 WIRING
EN
Important Safety Instrucons
THE TRIANGLE WITH THE LIGHTNING BOLT IS USED TO ALERT THE USER TO THE RISK OF ELECTRIC SHOCK.
THE TRIANGLE WITH THE EXCLAMATION POINT IS USED TO ALERT THE USER TO IMPORTANT OPERATING OR MAINTENANCE INSTRUCTIONS.
THE CE-MARK INDICATES THE COMPLIANCE OF THE PRODUCT TO ALL THE APPLICABLE EUROPEAN DIRECTIVES
SYMBOL FOR EARTH/GROUND CONNECTION.
SYMBOL INDICATING THAT THE EQUIPMENT IS FOR INDOOR USE ONLY.
SYMBOL FOR CONFORMITY WITH DIRECTIVE 2012/19/EC OF THE EUROPEAN PARLIAMENT ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT (WEEE).
DO NOT USE THE UNIT AT ALTITUDES ABOVE 2000 M.
DO NOT USE THE UNIT IN TROPICAL ENVIRONMENT.
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT ATTEMPT TO OPEN ANY PART OF THE UNIT. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
CONNECTION TO THE MAINS SHALL BE DONE ONLY BY A ELECTROTECHNICAL SKILLED PERSON ACCORDING THE NATIONAL REQUIREMENTS OF THE COUNTRIES WHERE THE UNIT IS SOLD.
DO NOT USE THIS AMPLIFIER IF THE ELECTRICAL POWER CORD IS FRAYED OR BROKEN.
TO AVOID ELECTRICAL SHOCK, DO NOT TOUCH ANY EXPOSED SPEAKER WIRING WHILE THE AMPLIFIER IS OPERATING.
DO NOT SPILL WATER OR OTHER LIQUIDS INTO OR ON THE AMPLIFIER.
NO NAKED FLAME SOURCES SUCH AS LIGHTED CANDLES SHOULD BE PLACED ON THE AMPLIFIER.
WARNING TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY ATTACHED TO THE FLOOR/WALL IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.
THIS DEVICE MUST BE POWERED EXCLUSIVELY BY EARTH CONNECTED MAINS SOCKETS IN ELECTRICAL NETWORKS COMPLIANT TO THE IEC 364 OR SIMILAR RULES
CAUTION
RISK OF ELECTRIC
SHOCK DO NOT OPEN
This unit has been engineered and manufactured to ensure your personal safety.
But IMPROPER USE CAN RESULT IN POTENTIAL ELECTRICAL SHOCK OR FIRE HAZARD.
In order not to defeat the safeguards incorporated into this product, observe the
following basic rules for its installaon, use and service. Please read these “Important
Safeguards” carefully before use.
• Read these instrucons.
• Keep these instrucons.
• Heed all warnings.
• Follow all instrucons.
• Do not use this equipment near water.
• Clean only with a dry cloth.
• Do not block any venlaon openings. Install in accordance with the
manufacturer’s instrucons.
• Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat.
• Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding­type plug has two blades and a third grounding prong. The wide blade or the
third prong are provided for your safety. If the provided plug does not t
into your outlet, consult an electrician for replacement of the obsolete outlet.
• Protect the power cord from being walked on or pinched parcularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
• Only use aachments/accessories specied by the manufacturer.
• Use only with the cart, stand, tripod, bracket, or table specied by the
manufacturer, or sold with the apparatus. When a cart is used, use cauon when moving the cart/apparatus combinaon to avoid injury from p-over.
• Unplug this apparatus during lightning storms or when unused for
long periods of me.
• Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such
as power-supply cord or plug is damaged, liquid has been spilled or objects
have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
• The apparatus shall be connected to a MAINS socket outlet with a protecve
earthing connecon
• Where the MAINS plug or an appropriate coupler is used as the disconnect device, the disconnect device shall remain readily operable.
DISCONNECT THE AC MAINS SOURCE BEFORE ATTEMPTING TO CLEAN ANY PART OF THE AMPLIFIER
POWERSOFT SUGGESTS TO PLUG THE T SERIES TO A 16 A RATING, C OR D CURVE, 10 KA SECTIONING BREAKER.
IT IS HIGHLY RECOMMENDED TO UNPLUG THE OUTPUT CONNECTORS BEFORE PROCEEDING WITH THE SELF CHECK PROCEDURE
THE TESTING SIGNALS MIGHT CAUSE LOUDSPEAKER IMPAIRMENTS.
OUTPUT TERMINALS ARE HAZARDOUS: WIRING CONNECTION TO THESE TERMINALS REQUIRES INSTALLATION BY AN INSTRUCTED PERSON AND THE USE OF READY MADE LEADS.
PROPERLY FIT THE AC MAINS PLUG TO THE AMPLIFIER INLET. BEFORE POWERING THIS AMPLIFIER, VERIFY THAT THE CORRECT VOLTAGE RATING IS BEING USED.
VERIFY THAT YOUR MAINS CONNECTION IS CAPABLE OF SATISFYING THE POWER RATINGS OF THE DEVICE.
TAKE CARE TO LOCK THE OUTPUT TERMINAL BEFORE SWITCHING THE DEVICE ON.
THE MANUFACTURER CANNOT BE HELD RESPONSIBLE FOR DAMAGES CAUSED TO PERSONS, THINGS OR DATA DUE TO AN IMPROPER OR MISSING GROUND CONNECTION.
CONTACT THE AUTHORIZED SERVICE CENTER FOR ORDINARY AND EXTRAORDINARY MAINTENANCE.
IT IS ABSOLUTELY NECESSARY TO VERIFY THESE FUNDAMENTAL REQUIREMENTS OF SAFETY AND, IN CASE OF DOUBT, REQUIRE AN ACCURATE CHECK BY QUALIFIED PERSONNEL.
2 | T Series
Page 3
EN
WEEE Direcve
If the me arises to throw away your product, please recycle all possible
component.
This symbol indicates that when the end-user wishes to
discard this product, it must be sent to separate collecon facilies for recovery and recycling. By separang this
product from other household-type waste, the volume
of waste sent to incinerators or land-lls will be reduced
and natural resources will thus be conserved.
The Waste Electrical and Electronic Equipment Direcve (WEEE Direcve)
aims to minimise the impact of electrical and electronic goods on the
environment. Powerso S.p.A. comply with the Direcve 2012/19/EU of the European Parliament on waste electrical nance the cost of treatment
and recovery of electronic equipment (WEEE) in order to reduce the
amount of WEEE that is being disposed of in land-ll site.
All of our products are marked with the WEEE symbol; this indicates that this product must NOT be disposed of with other waste. Instead it is the user’s responsibility to dispose of their waste electrical and electronic equipment by handing it over to an approved reprocessor, or by returning
it to Powerso S.p.A. for reprocessing. For more informaon about where you can send your waste equipment for recycling, please contact Powerso
S.p.A. or one of your local distributors.
EC Declaraon Of Conformity
Manufacturer:
Powerso S.p.A. via E. Con 5 50018 Scandicci (Fi)
Italy
We declare that under our sole responsibility the products: Model Names:
Intended use: Professional Audio Amplier
Are in conformity with the provisions of the following EC
Direcves, including all amendments, and with naonal legislaon implemenng these direcves: 2014/35/EU Low Voltage Direcve 2014/30/EU Electromagnec Compability Direcve 2011/65/EU RoHs Direcve
The following harmonized standards are applied:
EN 55032: 2012 EN 55035: 2017 EN 60065: 2014 /AC: 2016
Scandicci,
November 2018
Luca Lastrucci Managing Director
For compliance quesons only: compliance@powerso.it
In an eort to reduce the quanty of printed material while enhancing the quality of content, we have decided to adopt a new approach for the producon of this user guide.
All vital informaons have been condensed in two pages, and all illustraons and tables are now found in the newly implemented fold out
cov e r.
Colored bars are there to guide you to the right secon of the amplier: White numbers are there to guide you to specic elements of the secon:
2
All warnings and safety instrucons are now located on the rst page of each language, please do take the me to read these.
Less pages printed, less was in, more power out. Thank you for choosing Powerso as your purveyor of Green Audio Power.
T Series | 3
Page 4
EN
STATUS
NETWORK
SIGNAL
SWITCHED
70V
100V
25V
CAL
6s
3s
CTRL +CTRL +
CTRL
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
2 IN 1
OUT4 3
STATUS
NETWORK
SIGNAL
SWITCHED
70V
100V
25V
CAL
6s
3s
CTRL +CTRL +
CTRL
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
2 IN 1
OUT4 3
Preliminary operaons
Package list
The box contains the following:
1 Mezzo amplier
Block connectors 4 rubber feet 2 Bracket A 2 Bracket B
6 screws (for aaching the brackets)
Mains power cable
Locaon
Install your amplier in locaon that allows some exchange of air. Amplier comes with mounng accessories for the following mounng opons Surface mount – Using 2 “bracket B” it’s possible to mount an amplier vercally on a wall or upside down under a table or in a
ceiling.
Tandem 19” rack mount – Using the 2 “bracket B” it’s possible to
mount two Mezzo side to side and then mount them using the 2
“bracket A” in 1 RU in a 19” rack. Single 19” rack mount – Using the 2 “bracket A” it’s possible to mount a single amplier in a 19” rack. Single half rack mount – Using the 2 “bracket A” it’s possible to mount a single amplier in a half width rack. On a shelf – Aach the rubber feet to the boom of the amplier
and place it on the desired surface. Plenum mount – 320 W models are approved for placement in air handling spaces above the ceiling if the mains cable is mounted inside the plenum mount accessory (sold separately).
Custom mount – It’s possible to custom design ngs for poles and other applicaons using screws ng the threaded holes in the amplier. These screws must not be longer than XX mm. The safest
way to avoid mistakes is to use the provided screws.
Cooling
The 600W models implement a temperature controlled forced-air cooling system. Air enters from the front and exists at the back of
the amplier. The fan has 3 modes: STILL - if the temperature of the space surrounding the amplier is ≤35C and the average power out is ≤1 W per channel. (≤84 dB SPL*) WHISPER - if the average output is ≤4 W per channel. The fan noise at 1 m is ≤30 dBA in this mode. (≤90 dB SPL*)
REGULATED - Mezzo adapts the speed of the fan to stay cool. The
fan noise at 1 m is ≤45 dBA in this mode. (≤105 dB SPL* depending
on model and power sharing)
In the rare event of overheang the amplier will mute all channels and run the fans to reach a safe temperature and start operang
again.
It’s ok to stack ampliers on top of each other in a rack, but it’s
recommended to put them in banks of 4 RU and then leave a 1 RU space.
*(SPL at 2 m with 90 dB1W1m sensivity)
This amplier does not have a power switch. It will turn on automacally when AC power is connected and it will go to standby mode if no signal is present for 25 minutes. When input signal exceeding -60 dB relave the level needed for full power is applied the amplier will go back on within 2 seconds.
DSP and matrix conguraon
The amplier comprises a comprehensive range of funcons that
can be setup in two ways.
• Automac - without the use of any app or soware.
• Advanced - use the soware to set more parameters and
opmize the funconality.
This is a very easy way to congure the amplier that doesn’t require any soware. It is ideal if all you want is an amplier with a at frequency response that can monitored and if it is an AD model get audio routed to it with third party soware. The automac setup will set limiters so that a channel reaches the
maximum capacity of the power supply with -4 dBu balanced analog
input (or -6 dBFS for Dante/AES67). This means that it also adjusts the gain so that the amplier has the gain needed for all channels. The way to “assign power” is then simply done by adjusng the level of the content to the dierent channels. It will also set the high pass lters automacally. The cuto will be
selected so that frequencies below the resonance frequency as well as frequencies that saturate transformers in Hi-Z loudspeakers will
be aenuated.
Note! Automac conguraon is only possible when the amplier is in its factory default mode. Factory default is indicated by 5 seconds long blinks of the 70V and 100V LEDs. In order to restore Mezzo's factory default mode, press and hold the mode buon on the rear panel for 10 s.
Step 1 – Calibrate
SWITCHED
70V
25V
100V
IN2 1
CAL
3s
6s
CTRL
CTRL +CTRL +
I4 I3 I2 I1 5V
4 IN 3
STATUS
NETWORK
SIGNAL
2 IN 1
-10 dBV
Press the mode buon unl it fast blinks twice aer 2 s, release it within 2 s aer it has blinked. This will trigger an automac impedance
measurement taking 1 s per channel. This will be made at a level that is
high enough to properly measure an 8 ohm loudspeaker. If the impedance
is higher the measurement might be deemed to be too noisy and it will
then repeat itself automacally. Please note that it may generate an SPL exceeding 95 dB if the loudspeakers are sensive enough. The impedance measurement will automacally set warning thresholds
monitoring change. It will also set the limiters so that the channel can
play as loud as the design and model allows, without distoron.
Step 2 - Select the maximum voltage
SWITCHED
70V
25V
100V
IN2 1
CAL
3s
6s
CTRL
CTRL +CTRL +
I4 I3 I2 I1 5V
4 IN 3
STATUS
NETWORK
SIGNAL
2 IN 1
-10 dBV
No channel will ever be assigned limiters that exceed the power
of the power supply. The main reason for selecng the maximum voltage is to ensure that 25/70/100V loudspeakers will get the
power selected on their tapping if a channel is using less power than it can deliver.
If the applicaon is 25V or 70V, then there is a risk that the limiters
get set too high if the connected load isn’t requiring full power. This
is xed with short presses on the mode buon unl it shows the
desired maximum voltage:
70V
100V
LED
Max Peak
LED
Voltage
Unlit Lit 141.4 V
Lit Unlit 100 V
Lit Lit 35.4 V
Unlit Unlit Custom Sengs
peak
peak
peak
Max RMS
Voltage
100 V
rms
70.7 V
rms
25 V
rms
Descripon
Also works in mixed 100V and low
impedance conguraons Also works in mixed 70V and low
impedance conguraons Also works in mixed 70V and low
impedance conguraons
This can’t be selected on the rear panel. The limiters have been set manually
in the soware and can’t be changed
without a reset to factory defaults
4 | T Series
Page 5
Step 3 - Select the Ethernet mode of operaon (AD models)
STATUS
NETWORK
SIGNAL
SWITCHED
70V
100V
25V
CAL
6s
3s
CTRL +CTRL +
CTRL
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
2 IN 1
OUT4 3
EN
SWITCHED
70V
25V
100V
5 seconds
CAL
3s
IN2 1
6s
CTRL
CTRL +CTRL +
I4 I3 I2 I1 5V
4 IN 3
STATUS
NETWORK
SIGNAL
2 IN 1
-10 dBV
Press the mode buon unl it fast blinks (3 mes) aer 5 s, release it within 2 s aer it has blinked. This will reset the amplier to auto­IP and it will toggle the Ethernet mode and update the “Switched”
indicator:
• Unlit: This is the default “split mode”. The internal Ethernet
switch is disabled => the two ports are not connected and the
right port is then internally assigned for Dante/AES67. The le
port is only for control/monitoring.
• Lit: The internal Ethernet switch is enabled => the two ports are connected and will both work for Dante and control/monitoring. It means that you only need to connect with one cable for control and audio. It also means that the product can be inserted in a daisy chain of other Gigabit Ethernet products as long as there is enough bandwidth.
Step 4 - Roung and control via GPI
Dante/AES67 (AD models)
Dante &/ AES67 is enabled and it has priority over the corresponding
analog input if there is an audio signal coming over the network.
This could be congured in the Dante Controller or in a third party
plug-in.
4 Channel models
The analog 1 is always a mix on the unbalanced and the balanced analog 1; same with analog 2. The unbalanced input will get a 6 dB boost so that normal unbalanced sources will deliver enough level
to drive the amplier to full power. Otherwise the amplier will have straight 4 in 4 out roung and the 4 GPI inputs can be used with a 10kohm passive pot to aenuate the levels. If a dierent roung or a dierent funconality of the GPI pins is desired, then the soware needs to be used redene the funconality of the GPI pins. Please look at the Advanced conguraon (with soware) instead.
2 Channel models
The default here is that
• Whatever signal is delivered to output 1 is also delivered to
output 3 (but without the highpass lter). The level of these outputs can be aenuated with GPI1.
• Whatever signal is delivered to output 2 is also delivered to
output 4. The level of these outputs can be aenuated with GPI2.
Inputs 1 and 3 are mixed. Inputs 2 and 4 are mixed. This means that a balanced or unbalanced source can be used. It’s possible to
defeat this mixing by connecng GPI3 to GND. When this is done GPI4 denes which input signal pair is used with an external contact
closure between GPI4 and GND. Open → the balanced inputs are used; Closed → the unbalanced inputs are used.
T Series | 5
Page 6
Locaon Cooling
1 RU
4 4
3 3
2 2
1 1
1 RU
4 4
3 3
2 2
1 1
5
1 RU
Dimensions
210 mm
8.3 in
40 mm
1.5 in
10.8 in
275 mm
Page 7
Pinouts
Outputs (2 Channel Versions)
Ch 1
Ch 2
CH4 - CH3 Balanced Inputs
Ch 3
Ch 4
Outputs (4 Channel Versions)
Ch 1
Ch 2
Ch 3
Ch 4
CH2 - CH1 Balanced Inputs (4 Channel Version)
Ch 3
Ch 4
CH4 - CH3 Line Level Outputs (2 Channel Version) GPI
Ch 3
Ch 4
Network Connector RJ45 pinout
1 2 3 4 5 6 7 8
Color code (TIA/EIA-568-B) Pin
ORANGE / WHITE 1
ORANGE 2
GREEN / WHITE 3
BLUE 4
BLUE / WHITE 5
GREEN
BROWN / WHITE 7
BROWN 8
6
5V
I1
I2
I3
I4
Page 8
Rear Panels
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1
OUT4 3
MEZZO 602 A
ETH
RESET
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1
OUT4 3
MEZZO 602 A
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1
ETH
OUT4 3
RESET
ETH
RESET
ETH
RESET
MEZZO 322 A
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
IN2 1
-10 dBV
4 IN 3
MAINS
4 3 2 1
2 IN 1
MEZZO 604 A
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1
OUT4 3
MEZZO 602 A
ETH
RESET
STATUS
NETWORK
SIGNAL
SWITCHED
70V
100V
25V
CAL
6s
3s
CTRL +CTRL +
CTRL
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1
OUT4 3
MEZZO 602 AD
STATUS
NETWORK
SIGNAL
70V
100V
25V
CAL
6s
3s
I4 I3 I2 I1 5V
-10 dBV
4 IN 3
MAINS
2 1
2 IN 1
OUT4 3
MEZZO 322 AD
SWITCHED
CTRL +CTRL +
CTRL
Mezzo 322 A
1
MAINS
MEZZO 322 A
STATUS
NETWORK
7 7
SIGNAL
4 IN 3
2 2
2 1
3
2 IN 1
-10 dBV
RESET
CAL
70V
9
3s
25V
6s
100V
8
ETH
OUT4 3
4
5
6
I4 I3 I2 I1 5V
Mezzo 322 AD
1
MAINS
MEZZO 322 AD
Mezzo 602 A Mezzo 602 AD
STATUS
NETWORK
7
1 1
MAINS
MEZZO 602 A
2 2
2 1
SIGNAL
4 IN 3
3
2 IN 1
-10 dBV
RESET
CAL
70V
9
3s
25V
6s
100V
8
ETH
OUT4 3
4
5
6
I4 I3 I2 I1 5V
MAINS
MEZZO 602 AD
Rear panel - 2 Channel
1
AC Mains Connector / IEC 10A
2
CH2 -CH1 Outputs
3
CH4 - CH3 Balanced In puts
4
CH2 - CH1 Unbalanced Inputs
5
CH4 -CH3 Line Level Balanced Outputs
6
GPI
7
Amplier State LEDs
2 1
2 1
4 IN 3
3
4 IN 3
3
STATUS
NETWORK
SIGNAL
STATUS
NETWORK
7
SIGNAL
2 IN 1
-10 dBV
2 IN 1
-10 dBV
SWITCHED
CAL
70V
25V
100V
8
OUT4 3
4
5
SWITCHED
CAL
70V
25V
100V
8
OUT4 3
4
5
10
3s
6s
3s
6s
CTRL
CTRL
CTRL +CTRL +
6
I4 I3 I2 I1 5V
10
CTRL +CTRL +
6
I4 I3 I2 I1 5V
8
Load seng LEDs
9
RJ45 Fast Ethernet connector (Mezzo A Version)
10
2 X RJ45 Fast Ethernet connector (Mezzo AD Version)
Mezzo 324 A
STATUS
NETWORK
7 7
1
MAINS
MEZZO 324 A
2 2
4 3 2 1
4 IN 3
3
SIGNAL
2 IN 1
-10 dBV
4
Mezzo 604 A
STATUS
NETWORK
7
1 1
MAINS
MEZZO 604 A
2 2
4 3 2 1
4 IN 3
3
SIGNAL
2 IN 1
-10 dBV
4
Rear panel - 4 Channel
1
AC Mains Connector / IEC 10A
2
CH4 - CH3 - CH2 - CH1 Outputs
3
CH4 - CH3 Balanced Inputs
Mezzo 324 AD
RESET
CAL
70V
9
3s
25V
6s
100V
8
ETH
IN2 1
5
6
I4 I3 I2 I1 5V
1
MAINS
MEZZO 324 AD
4 3 2 1
NETWORK
4 IN 3
3
STATUS
SIGNAL
2 IN 1
-10 dBV
SWITCHED
CAL
70V
25V
100V
8
IN2 1
4
5
10
3s
6s
CTRL
CTRL +CTRL +
6
I4 I3 I2 I1 5V
Mezzo 604 AD
SWITCHED
4 IN 3
3
STATUS
NETWORK
7
SIGNAL
2 IN 1
-10 dBV
CAL
70V
25V
100V
8
IN2 1
4
5
10
3s
6s
CTRL
CTRL +CTRL +
6
I4 I3 I2 I1 5V
RESET
CAL
70V
9
3s
25V
6s
100V
8
ETH
IN2 1
5
6
I4 I3 I2 I1 5V
MAINS
MEZZO 604 AD
4 3 2 1
4
CH2 - CH1 Unbalanced Inputs
5
CH2 -CH1 Balanced Inputs
6
GPI
7
Amplier State LEDs
8
Load seng LEDs
9
RJ45 Fast Ethernet connector (Mezzo A Version)
10
2 X RJ45 Fast Ethernet connector (Mezzo AD Version)
Page 9
Page 10
DRIVING HUMAN AUDIO EXPERIENCE
POWERSOFT S.P.A.
Via E. Con, 5 - Scandicci (FI) 50018 - Italy
support@powerso.com
+39 055 73 50 230
+39 055 73 56 235
POWERSOFT.COM
Loading...