The Power Soak pot, pan and utensil washing system will provide years of dependable,
efficient and trouble-free service. Every system is manufactured to last, with only highquality, heavy-duty, 14 gauge stainless steel used in its construction. All electrical
components used in a Power Soak system are of the highest quality. The faucets and
drains are designed for quick filling and emptying of the system's tanks.
Most Power Soak systems are provided with a limited 3 year parts and labor warranty.
To inquire about the warranty status of a PS-275 Power Soak, please call the following
number and have the serial number of the machine available at the time of the call:
Power Soak Systems
(800) 444-9624
The people at Power Soak Systems take pride in manufacturing the Power Soak
equipment and are committed to standing behind Power Soak customers and products
100%.
1.1 General Description
The Power Soak PS-275 can be built with many variations to meet the needs of Power
Soak customers. The illustrations shown in this document cannot match all the possible
machine configurations, however; the information will apply even if a machine does not
match the illustration. The general configuration of a machine will start the work flow in
the scraping area and/or wash tank and finish in a sanitize tank and/or on a drain board.
The units that start with the scraping area and/or wash tank on the left are referred to as
a “left to right” or “left hand” unit. A “right to left” or “right hand” unit will start with the
scrap area and/or wash tank on the right hand side.
2
Messages – Section 2
2.0 Explanation of Warning Messages
Be sure to read, understand and follow all DANGER, WARNING, and CAUTION
messages located in this document and on the equipment. These messages are used
to identify areas of the machine that are harmful.
2.1 Danger
Personal Injury and Property Damage hazard.
Will result in serious injury or death.
Will cause extensive equipment damage
2.2 Warning
Property Damage Hazard.
Will result in property or equipment damage.
2.3 Chemical Hazard
Will result in serious injury or death.
Instructions, labels and Material Safety Data Sheets (MSDSs) are to
be supplied with all detergents and sanitizing chemicals. The
manufacturers, importers and distributors of the cleaning chemicals
are responsible for providing this information.
Power Soak Systems, Inc. is not a chemical manufacturer, importer or
distributor. Power Soak Systems, Inc. can assist the chemical
representative but will not make specific brand recommendations.
2.4 Personal Injury Hazard
Hazard from sharp objects.
Will result in serious injury or death.
3
Detergents and Sanitizer – Section 3
3.1 Detergents
Power Soak machines require a low-foaming and recommend a metal/aluminum-safe
detergent. The detergent should have good grease cutting abilities and pH level that is
safe for human contact. Improper detergents may damage the equipment. Use of the
correct detergent in the Power Soak PS-275 is critical to its washing performance. If
there are problems with cleaning results, please contact Power Soak Systems (1-800444-9624).
Detergents with high or low pH level will damage the
equipment and be harmful to human contact. Consult
with a chemical manufacturer representative for
recommendations on the selection of detergents.
3.2 Sanitizers
A "chemical sanitizing" method is used in the Power Soak system. There are a number
of products on the market that work well in this application. A chemical sales
representative should assist in selecting the proper sanitizer for each application. Check
with a cleaning chemical provider to determine the detergent concentration, sanitizer
"parts per million" (ppm) and sanitizer submersion times that will meet local health
codes.
3.3 Factory Assistance
If a chemical sales representative is having difficulty selecting a detergent or sanitizer,
or if there are poor results with the chemicals that have been recommended, please
contact a Power Soak representative at:
1-800-444-9624.
4
Preventative Maintenance - Section 4
PS-275
5
4.0 Maintenance
Power Soak machines require minimal preventive maintenance. To ensure that the Power
Soak PS-275 remains reliable, the following tasks should be completed at the intervals
shown in this section.
4.1 Daily
4.1a Clean the liquid level sensors
walls of the wash and sanitizer tanks (see section 7.4). They are white plastic discs with
metal centers. The faces of the sensors need to be cleaned with a washcloth and soapy
water. Regular cleaning will prevent a build-up of difficult to remove chemicals and debris.
- The liquid level sensors are located on the side
The liquid level sensors must be cleaned regularly in order for the
machine to operate correctly. Dirty sensors can allow the pump motor
to operate without water in the wash tank, which will cause serious
damage to the unit.
4.2 Monthly
4.2a Clean the motor fan shroud -
at the end of the motor closest to the control panel. Shut off the electrical supply at the
electrical circuit breaker located in the wall mounted enclosure. Clean the pump motor
fan shroud with a stiff bristle brush and a vacuum. If a brush and vacuum are unavailable,
clean the shroud with a damp, soapy cloth. This will prevent grease and dust from
accumulating in the openings of the cover and obstructing the airflow that cools the motor.
4.2b Clean the Heating Element
electrical circuit breaker located in the wall mounted enclosure. Remove the cover plate
located in the slanted surface of the back wall of the wash tank. Remove debris that has
collected in and around the heating element. Install the cover plate when cleaning is
completed. The cover plate must be installed after cleaning to prevent foreign objects
from entering the pump suction and causing damage to the pump.
The motor fan shroud is the "vented" cover located
- Shut off the electrical supply at the system’s
Failure to shut off the electrical supply will result in personal injury,
including serious injury or death, and extensive equipment damage.
4.3 Quarterly or as needed
4.3a De-lime the wash sink -
stainless steel sinks. Follow the instructions on the package for mixing and fill the tank
with water. Turn on the pump motor to circulate the mixture in the tank and pump
manifolds.
6
Select a de-liming agent that is safe for plastics and
Control Panel Lights - Section 5
PS-275
7
5.1 Control Panel Overlay
The Control Panel Overlay is bonded to the surface of the enclosure door and conceals
the membrane that contains the push buttons and lights. The panel lights are used to
indicate conditions that have been detected by the operating program. The lights on the
face of the control panel operate in conjunction with the Alert Light System located on
the bottom surface of the control box (lights that shine on the floor). There are some
conditions that are indicated by the control panel lights which are not part of the Alert
Light System. The operator should review the control panel lights when determining the
operating situation of the machine. See the chart in section 5.2 for interpreting the light
combinations.
HOT WASH
FLUID
CAUTION
DEEP CLEAN
MODE
GREEN
STATUS
LIGHT
SECTION 5.3
WHITE
POWER
LIGHT
SECTION 5.4
GREEN
UNLOAD/LOAD
SECTION 5.8
RED SANITIZE
TANK
SECTION 5.7
PURPLE
ERROR LIGHT
SECTION 5.5
BLUE WASH
TANK
SECTION 5.6
8
5.2 Light Illumination Code
9
5.3 Green Status Light
Off – Power to the machine is turned off or an over temperature
situation has occurred.
Slow Flashing – “POWER ON” – system is energized and ready
to fill the wash tank.
Solid Illumination – “OPERATING” – wash tank is full; START
button has been pressed, the program is running. (Note: if
the Stop button is pressed, the program is still running even
if the wash action is stopped, pressing the START button
will start the wash action) The wash solution must be
drained from the wash tank to exit the operating program.
Flashing with another light – indicating a message, see the chart in section 5.2.
Flashing a repeating “long & short” pattern – error has been detected, see error
codes in section 5.5a
5.4 Power Light
ON – Electrical power is connected to the PS-275
and the transformer inside the control panel
is producing the appropriate 24 VAC.
OFF – The power supply to the PS-275 is turned
off or the transformer inside the control
panel has failed.
5.5 Error Light
The error light is used to flash a code that indicates the
type of failure that has been detected by the UPM.
Section 5.5a identifies the meaning of the flashing
sequence.
10
5.5a Error Codes
Certain conditions create errors in the program operation. The purple ERROR light on
the front of the control panel along with the ERROR CODE light on the UPM will blink in
patterns to indicate the source of the error. The definitions for the patterns are as
follows:
“_“
symbol
“.”
symbol
represents a “
represents a “
long” flash
short”
flash
3 long & 1 short _ _ _
3 long & 2 short _ _ _
3 long & 3 short _ _ _
3 long & 4 short _ _ _
3 long & 5 short _ _ _
3 long & 6 short _ _ _
.
= Liquid Lev
. .
= Temperature Sensor Error
. . .
= Over-Current Error
. . . .
= Over Temperature Error
. . . . .
. . . . . .
= Current Sensor
= Membrane
el
Error
Error
Error
Liquid Level Error
signal to the UPM (W-H light is illuminated) and the low liquid level sensor is not
sending a signal to the UPM (W-L is not illuminated). The low level sensor may not be
functioning due to a coating of debris or a broken/disconnected wire that is preventing
the signal to the UPM. A continuous signal from the upper level sensor can be caused
by debris coating the face of the sensor or faulty wiring that has the sensor connection
grounded to the wash tank when there is no fluid in the tank. The liquid level lights on
the UPM can be used to help determine the problem (see Section 6.0 UPM & Section
7.6 Liquid Level Sensor).
Temperature Sensor Error
(see Section 7.5 Thermistor) that is outside the range of the UPM programming, the
temperature sensor error will actuate.
Over Current Error
current, the current sensor will send a signal to the UPM to start the Over Current Error
and deactivate the contactor which turns the power off to the machine (see Section 6.6
Contactor & Section 6.7 Load Sensor).
Over Temperature Error
will activate this error message and stop the machine. This error code cannot be reset
until the fluid is drained below the low level sensor in the wash tank.
– This error appears when the upper liquid level sensor sends a
– When the UPM receives a signal from the thermistor
– If any of the high voltage components begin drawing excessive
– If the fluid temperature in the wash tank exceeds 135°F it
Current Sensor Error
verify that it is connected and working. If it does not receive the signal, the UPM
program will stop the machine and give this error code (see Section 6.7 Load Sensor).
– The UPM must receive a signal from the current sensor to
11
Membrane Error
signal to the UPM, the program will recognize that the membrane is defective and
display this error code (see Section 6.9 Push Button Membrane).
Please have the “Error Code” information and serial number of the machine available
when calling Power Soak Systems for telephone assistance (1-800-444-9624). The
machine serial number will be used to identify the configuration of the machine. The
serial number is 5-6 digits long and located on the identification tag which is on the
lower corner of the wash tank close to the control panel enclosure.
Note: There are periods of unstable power from the incoming power source that can
cause a false error. Turning the electrical power off and on can reset the program if it is
a power source fluctuation that caused the error. Locate the wall mounted circuit
breaker box, turn the circuit breaker for the Power Soak machine off, pause for 15
seconds, turn the circuit breaker back on, and then check to see if the error code has
cleared.
– In the event that one of the control panel buttons sends a constant
5.6 Blue Wash Tank Light
Solid Illumination – “CHANGE WASH SOLUTION” the
wash cycle will be stopped until the wash tank is
completely drained and refilled.
Slow to Fast Flashing – wash solution life is expiring, 15
minute warning prior to solid illumination.
Flashing with Green Status light – occurs when tank is filling with water indicating near
full, rapid flashing indicates that the tank is full (NOTE: the fill indication feature is an
option that must be selected in the UPM settings, see programming manual 37193.)
5.7 Red Sanitizer Tank Light
Solid Illumination – “FILL SANITIZER TANK” – sanitizer tank
must be filled to the waterline.
OR
Solid Illumination – “CHANGE SANITIZE SOLUTION” – After
two hours, the sanitizer tank must be drained and refilled.
Slow to Fast Flashing – wash solution life is expiring, 15 minute warning prior to solid
illumination.
Flashing with Green Beacon light – occurs when tank is filling with water indicating near
full, rapid flashing indicates that the tank is full (NOTE: the fill indication feature is an
option that must be selected in the UPM settings, see programming manual 37193.)
12
Loading...
+ 42 hidden pages
You need points to download manuals.