POWEREX BCR30AM-8L, BCR30AM-8, BCR30AM-12L, BCR30AM-12 Datasheet

Dimensions Inches Millimeters
A 0.79 20.0 B 0.77 19.5 C 0.63 15.9 D 0.20 5.0 E 0.16 4.0 F 0.08 2.0 G 0.13 Dia. 3.2 Dia. H 0.08 2.0
Dimensions Inches Millimeters
J 0.04 1.0 K 0.21 5.45 L 0.18 4.5 M 0.06 1.5 N 0.02 0.6 P 0.17 4.4 Q 0.11 2.8 R 0.16 4.0
Description:
A triac is a solid state silicon AC switch which may be gate triggered from an off-state to an on-state for either polarity of applied voltage.
Features:
Planar PassivationSelected for Inductive Loads
Applications:
Contactless AC SwitchesMicrowave Ovens Motor Controls Lighting Controls
Ordering Information:
Example: Select the complete eight, nine or ten digit part number you desire from the table - i.e. BCR30AM-8 is a 400 Volt, 30 Ampere Triac.
V
DRM
Inductive
Type Volts Code Load*
BCR30AM 400 -8 L
600 -12
*For inductive load, add L.
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
Triac
30 Ampere/400-600 Volts
BCR30AM
Outline Drawing (Conforms to TO-3P)
T-87
C
BG
A
M
L
P
Q
KK
J
R
N
H
B
D
E
F
➀➁➂
OUTLINE DRAWING
➁➃
T1 TERMINAL T2 TERMINAL GATE T2 TERMINAL
CONNECTION DIAGRAM
Absolute Maximum Ratings, T
a
= 25 °C unless otherwise specified
Ratings Symbol BCR30AM-8 BCR30AM-12 Units
On-state Current, Tc= 75°C I
T(RMS)
30 30 Amperes
Repetitive Peak Off-state Voltage (Gate Open) V
DRM
400 600 Volts
Non-repetitive Peak Off-state Voltage (Gate Open) V
DSM
500 720 Volts
Non-repetitive Peak On-state Voltage, One Cycle (60 Hz) I
TSM
300 300 Amperes I2t for Fusing, t = 8.3 msec I2t 378 378 A2sec Peak Gate Power Dissipation, 20 msec P
GM
5 5 Watts
Average Gate Power Dissipation P
G(avg)
0.5 0.5 Watts
Peak Gate Current I
GM
2 2 Amperes
Peak Gate Voltage V
GM
10 10 Volts
Storage Temperature T
stg
-40 to 125 -40 to 125 °C
Operating Temperature T
j
-40 to 125 -40 to 125 °C
Weight 4.8 4.8 Grams
Electrical and Thermal Characteristics, T
j
= 25 °C unless otherwise specified
Test Conditions (Trigger Mode) BCR30GM
Characteristics Symbol V
D
R
L
R
G
T
j
Min. Typ. Max. Units
Gate Parameters DC Gate Trigger Current
MT2+ Gate+ I
FGT
I 6V 6V 330V 25°C 50 mA
MT2+ Gate– I
RGT
I 6V 6V 330V 25°C 50 mA
MT2– Gate– I
RGT
III 6V 6V 330V 25°C 50 mA
DC Gate Trigger Voltage
MT2+ Gate+ V
FGT
I 6V 6V 330V 25°C 2.5 Volts
MT2+ Gate– V
RGT
I 6V 6V 330V 25°C 2.5 Volts
MT2– Gate– V
RGT
III 6V 6V 330V 25°C 2.5 Volts
DC Gate Non-tr igger Voltage
All V
GD
1/2 V
DRM
125°C 0.2 Volts
Characteristics Symbol Test Conditions Min. Typ. Max. Units
Thermal Resistance, Junction-to-case R
th(c-f)
1.2 °C/W
Voltage – Blocking State I
DRM
Gate Open Circuited, 3 mA
Repetitive Off-state Current VD= V
DRM
, Tj= 125°C
Current – Conducting State V
TM
Tc= 25°C, 1.6 Volts
Peak On-state Voltage ITM= 45A
Critical Rate-of-Rise of Commutating (dv/dt)
c
V/ms Off-state Voltage (Commutating dv/dt) (Switching)
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR30AM Triac
30 Ampere/400-600 Volts
T-88
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR30AM Triac
30 Ampere/400-600 Volts
0.4
1.2
2.0
2.8
3.6
4.4
MAXIMUM ON-STATE
CHARACTERISTICS
INSTANTANEOUS ON-STATE CURRENT, IT, (AMPERES)
INSTANTANEOUS ON-STATE VOLTAGE, V
T
, (VOLTS)
10
0
10
1
10
2
10
3
TC= 25oC
0
TRANSIENT THERMAL
IMPEDANCE CHARACTERISTICS
CYCLES AT 60 Hz
TRANSIENT THERMAL IMPEDANCE, Z
th(j-c)
, (°C/WATT)
10
-1
10
0
10
2
10
3
10
1
10
2
0.4
0.8
1.2
1.6
2.0
10
-1
10
2
10
1
10
0
GATE CHARACTERISTICS
(I, II, III)
GATE CURRENT, IG, (mA)
GATE VOLTAGE, V
G
, (VOLTS)
10
2
10
1
10
3
10
4
V
GD
= 0.2V
V
GM
= 10V
V
GT
= 2.5V
I
GM
= 2A
P
GM
= 5W
P
G(avg)
= 0.5W
I
RGT I,
I
FGT I,
I
RGT III
0
100
200
300
400
500
MAXIMUM SURGE CURRENT
FOLLOWING RATED LOAD CONDITIONS
CYCLES AT 60 Hz
MAXIMUM PEAK SURGE CURRENT, I
TSM
, (AMPERES)
10
0
10
1
10
2
0
20
40
60
80
100
120
140
160
ALLOWABLE CASE TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
CASE TEMPERATURE, T
C
, (°C)
0 10 20 30 40
FOR AC CONTROL THIS GRAPH NEARLY APPLIES REGARDLESS OF THE CONDUCTION ANGLE
CONDUCTION
RESISTIVE,
INDUCTIVE
LOADS
0
20
40
60
80
100
120
140
160
ALLOWABLE AMBIENT TEMPERATURE
VS. RMS ON-STATE CURRENT
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
AMBIENT TEMPERATURE, T
a
, (°C)
0 10 20 30 40
RESISTIVE, INDUCTIVE LOADS NATURAL CONVECTION
120 x 120 x t 2.3 100 x 100 x t 2.3 160 x 160 x t 2.3
FIN: A PLATE PAINTED BLACK WITH GREASE CURVES APPLY REGARDLESS OF THE CONDUCTION ANGLE
360°
0
10
20
30
40
50
MAXIMUM ON-STATE POWER DISSIPATION
RMS ON-STATE CURRENT, I
T(RMS)
, (AMPERES)
MAXIMUM POWER DISSIPATION, (WATTS)
0 10 20 30 40 50
360° CONDUCTION RESISTIVE, INDUCTIVE LOADS
GATE TRIGGER CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
GATE TRIGGER CURRENT, (t°C)
GATE TRIGGER CURRENT, (25°C)
x 100%
-60 -20 20 60 100 140-40 0 40 80 120
10
1
10
2
10
3
I
RGT I, IRGT III
I
FGT I
GATE TRIGGER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
GATE TRIGGER VOLTAGE, (t°C)
GATE TRIGGER VOLTAGE, (25°C)
x 100%
-60 -20 20 60 100 140-40 0 40 80 120
10
1
10
2
10
3
T-89
Powerex,Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
BCR30AM Triac
30 Ampere/400-600 Volts
BREAKOVER VOLTAGE VS.
RATE OF RISE OF OFF-STATE VOLTAGE
(TYPICAL)
RATE OF RISE OF OFF-STATE VOLTAGE, dv/dt, (V/ms)
0
20
40
60
80
100
120
140
160
BREAKOVER VOLTAGE, (dv/dt = x V/ms)
BREAKOVER VOLTAGE, (dv/dt = 1V/ms)
x 100%
10
2
10
1
10
3
10
4
Tj = 125°C
I QUADRANT III QUADRANT
REPETITIVE PEAK OFF-STATE CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
-60 -20 20 60 100 140-40 0 40 80 120
10
2
10
3
10
4
10
5
REPETITIVE PEAK OFF-STATE CURRENT, (t°C)
REPETITIVE PEAK OFF-STATE CURRENT, (25°C)
x 100%
GATE TRIGGER CURRENT
VS. GATE CURRENT PULSE WIDTH
(TYPICAL)
GATE CURRENT PULSE WIDTH, tw, (ms)
GATE TRIGGER CURRENT, (t
w
)
GATE TRIGGER CURRENT, (DC)
x 100%
10
1
10
2
10
3
Tj = 25°C
10
0
10
1
10
2
I
FGT I
I
RGT III
I
RGT I
HOLDING CURRENT
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
-60 -20 20 60 100 140-40 0 40 80 120
10
1
10
2
10
3
HOLDING CURRENT, (t°C)
HOLDING CURRENT, (25°C)
x 100%
BREAKOVER VOLTAGE
VS. JUNCTION TEMPERATURE
(TYPICAL)
JUNCTION TEMPERATURE, Tj, (°C)
-60 -20 20 60 100 140-40 0 40 80 120
0
20
40
60
80
100
120
140
160
BREAKOVER VOLTAGE, (t°C)
BREAKOVER VOLTAGE, (25°C)
x 100%
COMMUTATION CHARACTERISTICS
(TYPICAL)
RATE OF DECAY OF ON-STATE
COMMUTATING CURRENT, (A/ms)
10
1
10
2
10
3
10
0
10
1
10
2
CRITICAL RATE OF RISE OF
OFF-STATE COMMUTATING VOLTAGE, (V/ms)
Tc = 125oC I
T
= 4 A
t
= 500 ms
V
D
= 200v
f = 3 Hz
MINIMUM CHARAC­TERISTICS VALUE
I QUADRANT
III QUADRANT
GATE TRIGGER CHARACTERISTICS
TEST CIRCUITS
TEST PROCEDURE I TEST PROCEDURE II
R
G
6V
6V
A
V
R
G
6V
6V
TEST PROCEDURE III
A
V
R
G
6V
6V
A
V
T-90
Commutating
dv/dt, (dv/dt)
c
Commutating Voltage &
D Part V
DRM
(V/msec) Current Waveform
Number (Volts) Minimum Test Condition (Inductive Load)
BCR30AM-8L 400 20 Tj = 125°C, BCR30AM-12L 600 20 Rate of Decay
On-state
Commutating Current
(di/dt)c= -016A/msec,
Peak Off-state
Voltage
VD= 400V
SUPPLY VOLTAGE
(di/dt)
C
(dv/dt)
C
V
D
V
D
MAIN CURRENT
MAIN VOLTAGE
t
t
t
Loading...