Climate Control Simplex
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in
personal injury and/or property damage! Retain instructions for future reference.
Description
The AS Series Powerex Simplex Air Compressors have been
designed, broken-in and tested to meet the most demanding
specifi cations in the pneumatic climate control industry for
low oil carryover and long life.
All Powerex air compressors have reliable operation and
feature high quality construction and components. An
unloading feature is included on all compressors to provide
loadless starting. Oil entrainment is minimized by the use of
lap joint piston rings, low compressor speeds and a special
lubricating oil with a high fl ash point and low carbon
content.
Powerex compressor motors are NEMA Class B design. Singlephase motors have built-in overload protection and a DPST
disconnect switch. Three-phase motors require a manual or
magnetic starter and three overload heater coils which may
be ordered as a factory mounted and wired option.
Safety Guidelines
This manual contains information that is very important
to know and understand. This information is provided for
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the following symbols.
Danger indicates an imminently
hazardous situation which, if
not avoided, WILL result in death or serious injury.
Warning indicates a potentially
hazardous situation which, if
not avoided, COULD result in death or serious injury.
Caution indicates a potentially
minor or moderate injury.
Notice indicates important
information, that if not
followed, may cause damage to equipment.
NOTE: Information that requires special attention.
CALIFORNIA PROPOSITION 65
This product or its power cord
may contain chemicals known
to the State of California to cause cancer and birth defects or
other reproductive harm. Wash hands after handling.
Specifi cations
Product AS Series Powerex Simplex Air Compressors
Performance
Specifi cations
Lubrication Splash Lubrication System
Operating
Voltages
Compression
Cycle
Motor
Overload
Protection
Pressure
Settings
Overpressure
Protection
Outlet Air
Connections
Tank Sizes 30 Gallon to 80 Gallon
California
Ordinance
462 (L) (2)
Tank Isolation Standard All Units
See Page 2
1Ø 115 - 280 / 230 Volts, 60 Hz
3Ø 280 - 230 / 460 Volts, 60 Hz
Single-Stage
1Ø Built-in Thermal Overload (Standard)
3Ø Magnetic Starter and Three Thermal
Overload Switches (Optional)
Cut-In: Factory Set at Approximately 70 psig (490 kPa)
Cut-Out: Factory Set at Approximately 90 psig (630 kPa)
ASME Safety Valve Factory Set and Sealed at
Approximately 115 psig (805 kPa)
3/4 inch NPT (30, 60, and 80 Gallon Tanks)
Meets Requirements of this Ordinance
The performance specifi cations are nominal and conform to acceptable industry standards. For application at conditions beyond these
specifi cations, consult the local Powerex offi ce. Powerex shall not be liable for damages resulting from misapplication or misuse of its products.
Powerex • 150 Production Drive • Harrison, OH 45030 • USA
IN259604AV 1/14
1-888-769-7979 • www.powerexinc.com

Climate Control Simplex
Performance Specifi cations
Motor Rating
Base Model
AS-107 -- 1725 980 2.1 1.07 0.71
AS-007 0.75 1725 980 2.1 1.07 0.71
AS-110 -- 1725 1120 3.5 1.74 1.15
AS-010 1.00 1750 1120 3.5 1.74 1.15
AS-015 1.5 1760 860 4.6 2.3 1.5
AS-020 2.0 1755 1250 6.9 3.4 2.3
AS-030 3.0 1725 1050 10.3 5.2 3.4
NOTE: 0.75 HP pumps must be used under altitudes of 5000 feet.
Above 5000 feet, 1 HP pumps must be used.
HP RPM 100% Runtime 50% Runtime 33% Runtime
Installation
MOUNTED AND CONNECTED OPTIONS
Magnetic Motor Starter
An optional magnetic motor starter which has been selected
and wired for the intended input voltage is available for all
units. All starters are furnished with properly sized overload
heaters.
Refrigerated Air Dryer
A factory mounted model Hankinson HPR 5-10 Series
refrigerated air dryer with automatic condensate drain trap
assembly, bypass valve is available as an option on all 3/4
through 3 Hp Powerex Simplex air compressors. Piping for air
dryer is done at the factory. Wiring to power source must be
done in the fi eld using integral cord and plug which fi ts into
a standard 120 volt receptacle.
Automatic Tank Drain
Powerex air compressors are ordered with either a manual or
electric type automatic tank drain. This unit is furnished with
a manual drain attachment.
Vibration Dampening Pads
Waffl e type design vibration pads are provided as standard
equipment.
Compressor RPM
Operation
Factory calibrated snap-acting DPST pressure electric
switches provide automatic cut-in and cut-out. Overpressure
protection is provided by an ASME safety relief valve. Receiver
tanks have a condensate drain valve with an extension for
easy access. All mounting bases are slotted for V-belt tension
adjustment to aid in maintaining proper compressor and
motor alignment.
All units are run through the factory break-in and are tested
for air delivery, leakage and power consumption.
Units are shipped with a proper fi ll of compressor oil in the
crankcase and are furnished with an intake fi lter/silencer with
a replaceable cartridge. This fi lter/silencer combination is
designed to remove contaminates in the inlet air and provide
quieter operation.
LUBRICATION
Check lubricating oil level at gauge. Refi ll if necessary. See
Figure 1.
Change oil according to maintenance schedule. Before
draining oil, remove oil supply cap and loosen oil drain cap to
release trapped air. Use Mobil Rarus 427
oils.
NOTE: All pump models operate turning clockwise opposite
the motor shaft / pump fl ywheel / belt guard side of the unit.
Improper rotation will cause oil to spray out of the breather
vent opening.
Dispose of oil in accordance
Compressor Capacity ACFM
with state or local codes.
®
or Mobil DTE heavy
AUTO E-DRAIN ASSEMBLY (See Figure 2)
NOTE: The automatic E-drain is assembled to tank.
1. Plug E-drain into 115V power outlet supply.
2. Adjust times accordingly.
2

Remove cap and use funnel
to add oil
Round (Red)
Climate Control Simplex
Manifold Assembly
Oil
N.C.
gauge
M
Oil gauge close-up
Secondary
Thermal
Overloads
MM
1Ø 230 VAC
Starter
Manual
Disconnect
Switch
Low
Comp.
Motor *
Oil drain
cap
Figure 1
Pressure
Switch
NOTE: “M” =
Magnetic
Contactor
Figure 3 - AS Series Single-phase wiring with pressure
switch used for pilot duty
Full
* With
Integral
Overload
TEST
ON
OFF
6
4
20
30
2
10
8
40
5
0.5
10
0.5
45
sec.
min.
Auto E-Drain
Figure 2
N.C.
Pressure
Switch
Comp.
Motor *
Manual
1Ø Line Voltage
Disconnect
Switch
NOTE: “M” =
Magnetic
Contactor
Figure 4 - AS Series Single-phase wiring with pressure
switch used as contactor
* With
Integral
Overload
Thermal
Overloads
O.L.
3Ø Line Voltage
M
M
M
Manual
Disconnect
Switch
M
NOTE: “M” =
Magnetic
Contactor
N.C.
Pressure
Switch
Figure 5 - AS Series Three-phase wiring with pressure
switch used for pilot duty
Comp.
Motor *
* With
Integral
Overload
3