Powercom 500S, 600S, 750S User Manual

OFFICE UPS
MULTI-DEVICE PROTECTION UPS
500S/600S/750S
Thank you for selecting this uninterrupted power source. It provides you with better protection for connected equipment.
Please read this manual!
This manual provides safety, installation and operating instructions that will help you derive the fullest performance and service life that the UPS has to offer.
Please save this manual!
It includes important instructions for the safe use of this UPS and for quick solutions factory service should take as the UPS comes into question.
Please save or recycle the packaging materials!
The UPS’s shipping materials were designed with great care to provide protection from transportation related damage. These materials are invaluable if you ever have to return the UPS for service. Damage created during delivery is not covered under the warranty.
USER’S MANUAL
1.Safety instructions
Caution: Risk of electric shock hazardous live parts inside this unit are
energized from the battery supply even when the input AC power is connected.
Warning: To reduce the risk of fire, replace only with the same type and
rating of fuse.
Warning: To reduce the risk of fire or electric shock, install in
temperature and humidity controlled indoor area of conductive contaminants.
CAUTION: OFFICE UPS has an internal battery source. When the
On/Off control is on, the Battery Power output outlets are energized, even when the unit is not plugged in.
Warning: Place OFFICE UPS indoors, in a protected area that has
adequate air flow, and is free from excessive dust. Do not place OFFICE UPS to be exposed in envirmonment of humidity, rain, heatemitting source, or directs sunlight.
Warning: Connect OFFICE UPS to a two-pole, three-wire, grounded AC
power outlet. The outlet must be protected by appropriate branch protection(fuse or circuit breaker).
Warning: Connection to any other type of outlet may result in a shock
hazard and riolate local electrical codes.
Warning: To reenergize OFFICE UPS in an emergency, first switch the
On/Off control to the off position. Then, unplug OFFICE UPS office from the wall outlet. To debilitate the unit entirely, disconnect the battery. (See “Battery Replacement” below.)
Warning: Use of OFFICE UPS in an life support applications where
failure of this equipment can reasonably be expected to cause the failure of the life support equipment or to significantly affect its safety or effectiveness is not recommended.
CAUTION: Risk of Electrical Shock! Battery circuit is not isolated from
AC input. Hazardous voltage may exist between terminal and ground. Disconnect power cord from wall receptacle before servicing battery.
CAUTION: Telephone line current limiting feature (where applicable)
could be rendered inoperable if improperly installed. Never install telephone wiring during an electrical storm.
2.CAUTION!
3.1Note: When delivered and stored, the battery in OFFICE UPS will more or less lose charge. Full recharge will be achieved after about 4 hours of normal operation. Do not expect full battery run time during this initial recharge period.
3.2Plug OFFICE UPS into an activating outlet. Do not plug it into a service branch that has a heavy motor load equipped with it (e.g., an air conditioner or refrigerator.) Operate in accordance with the indications below prior to switching OFFICE UPS on.
3.3Plug your computer and monitor into the Battery Power output outlets. Positions of the rest outlets provide for and datacritical device that requires power under condition of utility power failure (e.g., an external tape backup, storage drive or CD ROM.)
Caution: Never connect a laser printer with the Battery Power output outlets.
3.4Plug your system peripheral equipment (e.g., a scanner, fax printer, audio
device or generator ) into the Surge Protection outlets. There is no power supplied with these outlets in the event of utility power failure.
3.5The RJ45/RJ11 modular sockets are at the back of OFFICE UPS (300/500VA Models only), offering protection against surges brought to your computer’s fax/modem or network interface card by the telephone or network wiring. To protect a fax/modem, connect the existing cable from the wall outlet to the “IN ” jack. Connect the telephone cable that was supplied with OFFICE UPS from the “OUT” jack, to the fax/modem. To protect a 10Base TUPT network interface, contact your LAN manager for a short length of UTP cable with which the connection between the “OUT ” jack and your computer can be made.
3.6Connect Computer interface: UPSMON series software (or other software supporting RS232 communication) and an interface kits can be used with this UPS. Use only kits supplied or approved by the manufacturer. If used, connect the interface cable to the 9pin computer interface port to OFFICE UPS.
Note: Computer interface connection is optional. The UPS works properly without a computer interface connection. Caution: Use only factory supplied or authorized UPS monitoring cable.
3.7Switch On/Off control of all system equipment to the on position.
3.8Turn on OFFICE UPS, and all the outlets will be powered. UPS will also
perform a self-test function for 8 seconds, which resolves if the battery power is sufficient for connected loads. Always keep OFFICE UPS in “On” condition to keep optimal battery charge.
Note: Classify the instruction above as reference while battery has thoroughly worn out to be replaced.(3-6 years)