Posey Slim Supports User Manual

Posey® Slim Supports
Qua lity Pr oduct s since 1937
Slim SupportS
Customizes a standard wheelchair or geri-chair for petite patients/residents. The Slim Supports t snugly inside the
LATEX
seating area to provide bilateral torso support. Made of 3/8” (1 cm) plywood covered with padded foam and wipe-clean vinyl. Adjustable straps for attachment. One pair per package. Meets California #117 Flame Retardancy Standards
REF
6322 Wheelchair
REF
6323 Geri-chair
16”D x 5”H (front) - 12”H (rear) (41 cm x 13 cm - 31 cm)
23”D x 7”H (front) -12”H (rear) (58 cm x 18 cm - 31 cm)
monitorinG
Always follow your facility’s policies and procedures for
patient assessment, monitoring and rehabilitation
inSpection
Inspect before each use: check for broken stitches or parts; torn, cut or frayed material; or zippers or buckles that do not hold securely. DO NOT use soiled or damaged products.
Wheelchair application inStructionS:
1. Slim Supports are provided in pairs (right and left) and should be
placed between the wheelchair side panel and the patient. Place the zippered edge facing down and the hard side of the support toward the side panel.
2. To secure the Slim Support, work the bottom front strap between
the side panel and the seat rail until it clears the bottom of the arm. Pull the lower strap tightly, then connect it to the top strap on the outside of the side panel. To secure the straps, loop the bottom strap through the rings on the top strap (g. 1) and pull tightly.
3. Wrap the rear strap around the rear post and secure it using the
hook and loop closure.
4. Repeat the process for the opposite Slim Support.
SEATING & POSITIONING
Slim Supports (6322) for wheelchair
Slim Supports (6323) for geri-chair
THREADING
THROUGH SQUARE
LOOP RINGS
Fig. 1
REAR
STRAP
Fig. 2
Geri-chair application inStructionS:
1. Slim Supports are provided in pairs (right and left) and should be
placed between the side panel and the patient.
2. In g. 2, Slim Supports are shown in the horizontal position. This is
more appropriate for shorter patients.
3. In g. 3, Slim Supports are shown in the vertical position. This is
more appropriate for taller patients.
cleaninG inStructionS (all):
• Wipe Clean with mild detergent. OSHA approved
intermediate level disinfectants can be used per manufacturer instructions. DO NOT use phenol and benzyl based disinfectants.
• After cleaning, products MUST be rinsed with water to remove any
residual chemicals.
• Make sure products are completely dry before use.
DiSpoSal
Properly dispose of the product per facility’s policy for BIOHAZARDOUS materials.
Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA Phone: 1.800.447.6739 • Fax: 1.800.767.3933 • Web: www.posey.com
Fig. 3
StoraGe anD hanDlinG
This device is designed for use in normal indoor environments. This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.
© 2009 Posey Company. All rights reserved.