Posey® Seizure Side Rail Pads
Application Instructions
Posey Seizure Pads are form fi tted to fi t snugly over the existing bed side rails with a 1” (3 cm) layer of medium density foam to help safeguard against accidental patient injury. The outer shell is constructed from lightweight sheer nylon denier to help prevent patient “rub” burns and allows unobstructed movement of the side rails to the lowered position. The nylon cover is backed with a urethane waterproof coating that easily wipes clean with liquid disinfectant. Open windows in upper section allow for easy access to controls on most bed models. Navy Blue.
Cat. No. Description Pads
Hill-Rom® Beds
REF
5725 Fits Advanta™ and Century Plus® beds 4
REF
5729 Fits Advanta™ (Pre- 02/2004), Advance®, Century 8500,
and Century CC Beds 4
REF
5742 Fits CareAssist® and Advanta™ 2 Beds 4
REF
5743 Fits VersaCare® Med / Surg Beds 4
REF
5744 Fits Affi nity III® and IV® Maternity Beds 2
REF
5746 Fits TotalCare® Med / Surg Beds 4
REF
5747 Fits Resident® LTC Beds 2
REF
5756 Fits Progressa® Beds 4
REF
5760 Fits Hill-Rom Low® Beds 2
REF
5761 Fits Affi nity II® Maternity Beds 2
Stryker® Beds
REF
5755 Fits Secure I and II® Beds with Rounded Side Rails 4
REF
5762 Fits Secure I and II® Beds with Rectangular Side Rails 4
REF
5763 Fits GO Bed II® with Rectangular Side Rails 4
REF
5764 Fits In-Touch™ Critical Care Beds 4
REF
5766 Fits S3™ Beds 4
Other Manufacturers
REF
5760 Fits Carroll® Beds with Care Assist Arms 2
REF
5765 Fits Med-Mizer® Beds with Med Support Arms 2
Monitoring
Posey Seizure Side Rail Pads will not prevent a determined patient from exiting the bed, going over or attempting to go between or through side rail gaps. Not all hospital beds allow for full articulation when this product is applied. Slowly articulate the head of the bed to ensure compatibility. Always follow your facility’s policies and procedures for patient assessment, monitoring and rehabilitation.
Application Instructions:
1. Inspect product set prior to use. Do not use soiled or damaged products.
2. Identify each of the components in the set. Each pad has sewn-in
tags, identifying its intended location from the perspective of lying down in the bed (Fig. 1).
3. Place each of the pads onto the proper side rail and shift it into
position (Fig. 2).
Fig. 2Fig. 1
Fig. 3
Fig. 4
4. Securely fasten all the hook-and-loop fasteners along the edges of each pad. Some pads may have additional hook-and-loop fasteners in their mid-sections, for those pads please see Fig. 3 and Fig. 4.
5. Lower each of the side rails to check clearances. Note that there may be some resistance as the rails are completely lowered. This should be expected as there are close manu facturing tolerances between the bed and the side rail. The shear nylon covers are chosen to minimize any potential binding.
6. Check for proper fi t. Modifi ed beds may not be compatible with Posey Seizure Side Rail Pads.
Disposal
Properly dispose of the product per facility’s policy for
BIOHAZARDOUS materials.
Storage and Handling
This device is designed for use in normal indoor environments. This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.
Cleaning Instructions:
Wipe clean with soap and water or disinfectant. DO NOT use cleaners that contain Phenol or Benzyl.
Fig. 3
Advance, Advanta, Affi nity, CareAssist, Century Plus, Progressa, Resident, TotalCare and VersaCare, are registered trademarks of Hill-Rom® Services, Inc. Med-Mizer is a registered trademark of Med-Mizer Inc. Go-Bed II, In-Touch, Secure, S3 and Stryker are registered trademarks of the Stryker® Corporation.
M6132 REV D 091015© 2015 Posey Company. All rights reserved.