Posey KeepSafe Door Guard Alarm User Manual

®
Cat.# 8373
Posey Company
Arcadia, CA 91006 USA
800-447-6739
www.posey.com
P
Posey
FALL MANAGEMENT
KeepSafe® Essential Door Guard Alarm/
Do Not Enter Banner Alarm
The Posey Keepsafe® Essential Door Guard Alarm and Do Not Enter Banner Alarm provide a visual reminder to residents/ patients and deters exit through doorways. Once activated, the alarm alerts caregivers of an unassisted exit or movement beyond a marked area.
REF
8205KE KeepSafe Essential Door
Guard Alarm
REF
7999KE KeepSafe Essential Do Not
Enter Banner Alarm
Monitoring
Be sure to follow your facility’s policies and guidelines for frequency of patient monitoring.
Inspection
Inspect before each use. Check for broken stitches, or torn, cut or frayed material. Banner does not prevent residents from exiting through door.
Application Instructions
1. Selecting Alarm Tone: The KeepSafe®
a. To step through the five tone options,
press the tone selector inside the battery compartment.
b. When the magnet is engaged, pressing
the tone selector will produce a two second audio demonstration of each tone.
c. If the two second demonstration is
not enough to determine your tone preference, remove the magnetic block. Press the tone selector until the desired tone is heard, then replace the magnet.
d. The last tone selected will automatically
sound when the alarm is activated.
2. Attach the alarm unit to the doorknob
side of the door frame, above waist level. Attach self-adhesive loop (fuzzy) patch by peeling off backing and pressing into place. Install alarm on bracket and attach to loop material.
3. Attach the white plastic hook on the
opposite side of the door frame. Peel off backing and press plastic hook (adhesive) into place.
4. Position the Door Guard Banner across
the doorway by attaching the magnet to
the center metal plate on one side and the loop to the plastic hook on the other side. To reposition the pre-connected magnet, unthread the key ring and reconnect through the grommet hole on the opposite side.
5. The Banner should be taut across the doorway. Adjust the banner by selecting the appropriate loop and attaching to the plastic hook.
Testing Instructions
A LWAYS test after application to door. To test the Door Guard, place your hand or arm against the mesh to move the banner far enough to disengage the magnet from the faceplate of the Keepsafe® Essential Alarm. Alarm should sound.
A LWAYS verify you can hear the alarm
volume at the furthest possible distance before leaving patient unattended.
NEVER place the alarm unit closer than
two feet from patient’s ear to minimize patient noise exposure. Refer to Occupational Safety and Health Administration Occupational Noise Exposure Standards 1910.95 for additional information.
8205KE
7999KE
Battery Replacement
1. Make sure the magnet remains attached to the center metal plate.
2. Press down on the arrow and slide battery compartment (Fig. 1)
3. Pull on red ribbon to remove four (4) “AAA” batteries from the battery compartment. (Fig. 2)
4. Four (4) new “AAA” batteries should be inserted on top of the red ribbon. The loose end of the ribbon should stick out for easy battery removal.
5. Lay the loose end of the red ribbon on top of the batteries and reattach the battery compartment door. Slide it shut. locking into place.
Fig. 1
Tone Volume
Voice
VoiceTone
&
Tone
ANSI-24A IEC-LR03
Qty 4AAA Alkaline
Fig. 2
(Continued on Page 2)
Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA • www.posey.com Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014 MADE IN U.S.A.
© 2012 Posey Company. All rights reserved.
M6252 REV A 071112
®
SUS
Cat.# 8373
Posey Company
Arcadia, CA 91006 USA 800-447-6739
www.posey.com
Posey
PEND
KeepSafe® Essential Door Guard/Do Not Enter Alarm
Tone Volume
Voice
VoiceTone
&
Tone
ANSI-2 4A IEC-LR 03
Qty 4 AAA Alkal ine
(Cont.)
Battery Door Battery Compartment
Metal Plate
Magnet Retention
Plates
Loop Patch (adhesive)
Magnetic Block
Plastic Hook
Alarm Testing Instructions
NEVER leave a patient unattended without first testing the alarm to ensure it is functioning as intended.
To test the KeepSafe® Essential Alarm, remove the magnet from the faceplate. The alarm should sound.
• Battery can explode or leak and cause damage to alarm or skin if installed backwards, disassembled, fully discharged or exposed to water, fire or high temperatures.
A LWAYS install a completely new battery when the low battery indicator chirps.
• Installing batteries incorrectly can cause batteries to utilize more power than normal and discharge sooner, causing possible corrosion. Take care when installing new batteries.
PRESS LEVER
SLIDE OUT
Maintaining Hook and Loop:
If hook and loop does not adhere, it is most likely due to collection of dust and lint. Clean hook by brushing with a stiff brush.
Storage and Handling
• This device is designed for use in normal indoor environments.
• This device may be stored in ambient warehouse temperatures at normal humidity levels. Avoid excess moisture or high humidity that may damage product materials.
Disposal
Dispose of per your facility policy or applicable local code for BIOHAZARDOUS material.
Hook Patch
Installed
Mounting Bracket
Limited Lifetime Warranty:
The Posey Company warrants to the original purchaser, the alarm unit to be free from defects in materials and workmanship for the life of the unit. Warranty void if unit is opened, damaged, or submerged. This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state.
Washing Instructions:
• Door Guard and Do Not Enter Banner may be laundered. Machine luke warm wash, tumble dry low.
• The alarm surface may be wiped clean with a mild non-phenol or non-benzyl disinfectant.
Posey Company • 5635 Peck Road, Arcadia, CA 91006-0020 USA Phone: 1.800.447.6739 or 1.626.443.3143 • Fax: 1.800.767.3933 or 1.626.443.5014 • Web: www.posey.com