PolyScience Refrigerated Recirculating Chillers, 6206, 6306, 6506, 6706 Operator's Manual

...
Operators Manual
Refrigerated Recirculating Chillers
110-240 Rev. H
06/06
EC Declaration of Conformity
The Products herewith complies with the requirements, as stated below, in accordance to the EC Low Voltage Directive 73/23/EEC and EC Electromagnetic Compatibility Directive 89/336/EEC, and carries the marking
accordingly.
We herewith declare:
That the following equipment complies with the essential requirements in respect to safety and health, in accordance to the EC Directives based on its design and type, as brought into circulation by us. In case of alteration of the equipment, not agreed upon by us, this will lose its validity.
Product Description: Refrigerated Chillers
Testing Bodies:
PolyScience Division of Preston Industries, Inc. 6600 West Touhy Avenue P.O. Box 48312 Niles, Illinois 60714, USA
6206, 6306, 6506, 6706, 6106, 5206, 5306, 5706, 5106; 1171, 1173, 1175, 1177, 1179, 512CR, 517CR
Low Voltage Directive 73/23/EEC & Electromagnetic Compatibility 89/336/EEC and relevant transpositions into national law of the member states, including, but not limited to the following Harmonized Standards: EN/IEC 61010-1: 2001 EN/IEC 61010-2 EN 61326: 1997 +A1: 1998 + A2:2001 CISPR 11/EN 55011 Class A, Group I
CSA International (Certification & Testing Division) D.L.S. Electronic Systems Inc. ( EMC approval)
Signature on Behalf of Manufacturer or Authorized
Representative: Date of Validity: Title of Signatory:
110-266 Rev. D 10/05
Brian Klotz October 18, 2005 Engineering Manager
2
WEEE Directive
A label with a crossed-out wheeled bin symbol and a rectangular bar indicates that the product is covered by the Waste Electrical and Electronic Equipment (WEEE) Directive and is not to be disposed of as unsorted municipal waste.
Any products marked with this symbol must be collected separately, according to the regulatory guidelines in your area.
The objectives of this program are to preserve, protect and improve the quality of the environment, protect human health, and utilize natural resources prudently and rationally. Specific treatment of WEEE is indispensable in order to avoid the dispersion of pollutants into the recycled material or waste stream. Such treatment is the most effective means of protecting the customer’s environment.
Requirements for waste collection, reuse, recycling, and recovery programs vary by regulatory authority at your location.
Contact your local responsible body (e.g., your laboratory manager) or authorized representative for information regarding applicable disposal regulations.
Contact PolyScience at the web site listed below for information.
Web address: www.polyscience.com
Customer Care: 1-800-229-7569 (inside the USA) (+1) 847-647-0611 (outside the USA) Fax 1-847-647-1155
or
3
Table of Contents
Section 1 - General Information
1.1 Warranty
1.2 Unpacking
Section 2 – Overview
2.1 Contents
2.2 Description
2.3 Chiller Specifications and Pump Performance
Section 3 – Installation and Startup
3.1 Site Requirements
3.2 Electrical Power
3.3 Optional Signal Inputs/Outputs
3.4 Plumbing
3.5 Closed System or Cooling Coil Setup
3.6 Open Bath System Setup
3.7 Startup
Section 4 – Operation
4.1 Selecting the Temperature Unit (°C or °F)
4.2 Displaying and Adjusting the Set Point
4.3 Displaying and Adjusting the Ambient Tracking Offset
4.4 Displaying and Adjusting Remote Control Temperature
4.5 Selecting the Pressure / Flow Rate Display and Units
4.6 Selecting Internal/External Temperature Display
4.7 Setting Operational Parameters
4.8 Display, Alarm, and Error Messages
4.9 Adjusting the High Pressure Bypass Setting
4.10 Enabling/Disabling the Local Lockout
Section 5 – Maintenance and Calibration
5.1 Standard Magnetic Drive Centrifugal Pump
5.2 Condenser, Air Vents, and Reusable Filter
5.3 Fluid Filter
5.4 Fluid Level
5.5 Temperature Calibration
5.6 Flow Rate Calibration
Section 6 - Troubleshooting
6.1 Unit Will Not Operate (No Cooling or Pumping)
6.2 No Pumping
6.3 Insufficient Pumping
6.4 No Cooling or Insufficient Cooling
6.5 Triac Failure
6.6 Internal Probe Failure
6.7 External Temperature Probe Failure
6.8 Diagnostic Mode
Section 7 - Service and Technical Support
7.1 Electrical Wiring Diagram
7.2 Process Flow Diagram
Section 8 - Replacement Parts
Section 9 – RS232
4
Section 1 - General Information
1.1 Warranty
Thank you for purchasing this chiller. We are confident it will serve you for a long time. Our warranty to you is as follows:
The manufacturer agrees to correct for the original user of this product, either by repair, or at the manufacturer's election, by replacement, any defect that develops after delivery of this product within the period as stated on the warranty card. In the event of replacement, the replacement unit will be warranted for 90 days or warranted for the remainder of the original unit’s parts or labor warranty period, whichever is longer.
If this product requires service, contact the manufacturer/supplier's office for instructions. When return of the product is necessary, a return authorization number will be assigned and the product should be shipped, transportation charges pre-paid, to the indicated service center. To insure prompt handling, the return authorization number should be placed on the outside of the package and a detailed explanation of the defect enclosed with the item.
This warranty shall not apply if the defect or malfunction was caused by accident, neglect, unreasonable use, improper service, or other causes not arising out of defects in material or workmanship. There are no warranties, expressed or implied, including, but not limited to, those of merchantability or fitness for a particular purpose which extends beyond the description and period set forth herein.
The manufacturer's sole obligation under this warranty is limited to the repair or replacement of a defective product and shall not, in any event, be liable for any incidental or consequential damages of any kind resulting from use or possession of this product. Some states do not allow: (A) limitations on how long an implied warranty lasts; or (B) the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights. You may have other rights that vary from state to state.
1.2 Unpacking
Your Chiller is shipped in a special carton. Retain the carton and all packing materials until the unit is completely assembled and working properly. Set up and run the unit immediately to confirm proper operation. Beyond one week, your unit may be warranty repaired, but not replaced. If the unit is damaged or does not operate properly, contact the transportation company, file a damage claim and contact the company where your unit was purchased immediately.
This symbol marks chapters and sections of this instruction manual that are particularly relevant to safety. When attached to the unit, this symbol draws attention to the relevant section of the instruction manual.
This symbol indicates that hazardous voltages may be present.
Read all instructions pertaining to safety, set-up, and operation.
Proper operation is the users’ responsibility.
5
Section 2 -- Overview
2.1 Contents
— Recirculating Chiller — Operators Manual — Warranty Card
— IEC Power Cord — Two sets of Inlet/Outlet Adapters: ½ inch male NPT, 5/8 inch male NPT
2.2 Description
These Refrigerated Recirculating Chillers provide cooling power for demanding applications and serve as an economical alternative to tap water cooling systems. All models feature a microprocessor-based controller, digital temperature display (°C or °F), one-touch set point display, and digital pressure/flow rate display (PSI, kPa, GPM, LPM) with push-button selection.
To optimize cooling efficiency and performance, these sophisticated Chillers also feature a modulated refrigeration system. As a result, temperature stability is greatly enhanced and compressor life extended.
Refrigerated Recirculating Chillers are equipped with either a centrifugal, positive displacement, or regenerative turbine pump. Wetted parts within the recirculation system are brass, stainless steel, polyethylene, EPDM rubber, and nylon.
4
6
7
12
1
2
15
3
9
10
13
8
Front/Top Rear
1. Temperature Display 9. Fluid Outlet
2. Select/Set Knob 10. Fluid Inlet
3. Power Button 11. Drain
4. Reservoir Cap and Internal Fluid Filter (top) 12. Reservoir Fluid Level Gauge
5. Air Filter 13. Circuit Breaker / Power Switch
6. Pressure / Flow Rate Display 14. IEC Power Connection
7. Units / Menu Select Button 15. Remote I/O Connection (optional)
8. Ambient Tracking Probe Connection (optional) 16. RS232 / RS 485 Connection (optional)
5
14
16
11
6
2.3 Chiller Specifications and Pump Performance
General Specifications (all Chillers)
Temperature Set Point Resolution ±0.1°C
Temperature Stability ±0.1°C
Temperature Units °C or °F
Pressure Units PSI or kPa
Pressure Display Resolution Pressure Display Accuracy
1 PSI / 6.9 kPa ±3.5% of full scale (100PSI)
Flow Rate Units GPM or LPM
Flow Rate Display Resolution
Flow Rate Display Accuracy
0.1 GPM / 1 LPM
+/- 0.4 GPM / 1.5 LPM
Pump Inlet and Outlet ½ inch NPT
Pump Performance
¼ HP
1
/3 HP
½ HP
All Models
¾ HP
1 HP
Magnetic Drive Centrifugal Pump Positive Displacement Pump
¼ HP
1
/3 HP ½ HP ¾ HP
1 HP
Turbine Pump
7
Specifications — 1/4-HP, 1/3-HP, and 1/2-HP Chillers
Model: Rfg = Refrigerating Only Rfg / Htg = Refrigerating & Heating
Magnetic Drive Centrifugal Pump
Model Rfg Rfg / Htg Rfg Rfg / Htg Rfg
Operating Temperature
Compressor 1/4 HP 1/3 HP 1/2 HP
Cooling Capacity @ 20°C 10°C 0°C
Pressure at 0 Flow Rate 10 psi / 69 kPa 10 psi / 69 kPa 10 psi / 69 kPa
Flow Rate at 0 psi 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm
Reservoir Capacity 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters
Dimensions (h x w x d)
Shipping Weight
120 V, 60 Hz Chillers
Volts Range
Amps 9.5A 10.0A 10.4A 10.7A 13.5A
240 V, 50 Hz Chillers
Volts Range Over Voltage
Amps 5.6A 5.9A 5.9A 6.2A 7.2A
Positive Displacement Pump (“P” Series Chillers)
-10° to 40°C
800 watts 2728 BTU/hr 500 watts 1705 BTU/hr 200 watts 682 BTU/hr
131 pounds
59.4 kg
-10° to 70°C
-10° to 40°C
1200 watts 4092 BTU/hr 900 watts 3069 BTU/hr 500 watts 1705 BTU/hr
22-5/8 x 14-1/2 x 27-5/8 in.
57.5 x 36.8 x 70.2 cm
143 pounds
108 to 132V
198 to 264V
Category II
-10° to 70°C
64.8 kg
-10° to 40°C
1700 watts 5797 BTU/hr 1100 watts 3751 BTU/hr 750 watts 2557 BTU/hr
168 pounds
76.2 kg
Model P Series Chillers Rfg Rfg / Htg Rfg P Rfg / Htg Rfg
Operating Temperature
Compressor 1/4 HP 1/3 HP 1/2 HP
Cooling Capacity @ 20°C 10°C 0°C
Flow Rate @ 0 psi 1 gpm / 3.75 lpm 1 gpm / 3.75 lpm 1 gpm / 3.75 lpm
Pump Pressure (adjustable)
Reservoir Capacity 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters
Shipping Weight
120 V, 60 Hz Chillers
Volts Range
Amps 12.2A 12.5A 13.1A 13.5A 16.0A
240 V, 50 Hz Chillers
Volts Range Over Voltage
Amps 6.8A 7.1A 7.3A 7.6A 8.9A
-10° to 40°C
800 watts 2728 BTU/hr 500 watts 1705 BTU/hr 200 watts 682 BTU/hr
20 to 100 psi
138 to 689 kPa
141 pounds
64 kg
-10°C to 70°C
-10° to 40°C
1200 watts 4092 BTU/hr 900 watts 3069 BTU/hr 500 watts 1705 BTU/hr
20 to 100 psi
138 to 689 kPa
153 pounds
108 to 132V
198 to 264V
-10°C to 70°C
69 kg
Category II
-10° to 40°C
1700 watts 5797 BTU/hr 1100 watts 3751 BTU/hr 750 watts 2557 BTU/hr
20 to 100 psi
138 to 689 kPa
178 pounds
81 kg
8
Model: Rfg = Refrigerating Only Rfg / Htg = Refrigerating & Heating
Turbine Pump (“T” Series Chillers)
Model T Series Chillers Rfg Rfg / Htg Rfg Rfg / Htg Rfg
Operating Temperature
Compressor 1/4 HP 1/3 HP 1/2 HP
Cooling Capacity @ 20°C 10°C 0°C
Flow Rate @ 0 psi 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm
Pump Pressure (adjustable)
Reservoir Capacity 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters
Shipping Weight
120 V, 60 Hz Chillers
Volts Range
Amps 12.2A 12.5A 13.1A 13.5A 16.0A
240 V, 50 Hz Chillers
Volts Range Over Voltage
Amps 6.8A 7.1A 7.3A 7.6A 8.9A
Specifications subject to change without notice.
-10° to 40°C
800 watts 2728 BTU/hr 500 watts 1705 BTU/hr 200 watts 682 BTU/hr
20 to 90 psi
138 to 621 kPa
143 pounds
65 kg
-10°C to 70°C
-10° to 40°C
1200 watts 4092 BTU/hr 900 watts 3069 BTU/hr 500 watts 1705 BTU/hr
20 to 90 psi
138 to 621 kPa
156 pounds
108 to 132V
198 to 264V
-10°C to 70°C
71 kg
Category II
-10° to 40°C
1700 watts 5797 BTU/hr 1100 watts 3751 BTU/hr 750 watts 2557 BTU/hr
20 to 90 psi
138 to 621 kPa
181 pounds
82 kg
9
Specifications — 3/4-HP and 1-HP Chillers
Model: Rfg = Refrigerating Only Rfg / Htg = Refrigerating & Heating
Magnetic Drive Centrifugal Pump
Model Rfg Rfg / Htg Rfg Rfg / Htg
Operating Temperature -10° to 40°C -10° to 70°C -10° to 40°C -10 to 70°C
Compressor 3/4 HP 1 HP
Cooling Capacity @ 20°C 10°C 0°C
Pressure at 0 Flow Rate 10 psi / 69 kPa 10 psi / 69 kPa
Flow Rate at 0 psi 4.1 gpm / 15.5 lpm 4.1 gpm / 15.5 lpm
Reservoir Capacity 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters
Dimensions (h x w x d)
Shipping Weight
208-230 V, 60 Hz
Volts Range
Amps 9.2A 9.5A 9.5A 9.8A
240 V, 50 Hz
Volts Range Over Voltage
Amps 9.2A 9.5A 9.5A 9.8A
2500 watts 8525 BTU/hr 1700 watts 5797 BTU/hr 760 watts 2591 BTU/hr
22-5/8 x 14-1/2 x 27-5/8 in.
57.6 x 36.8 x 70.2 cm
187 pounds
84.8 kg
187 to 253V
198 to 264V
Category II
2900 watts 9889 BTU/hr 1950 watts 6649 BTU/hr 1000 watts 3410 BTU/hr
189 pounds
85.7 kg
Positive Displacement Pump (“P” Series Chillers)
Model P Series Chillers Rfg Rfg / Htg Rfg Rfg / Htg
Operating Temperature -10° to 40°C -10° to 70°C -10° to 40°C -10° to 70°C
Compressor 3/4 HP 1 HP
Cooling Capacity @ 20°C 10°C 0°C
Flow Rate @ 0 psi 3.5 gpm / 13.2 lpm 3.5 gpm / 13.2 lpm
Pump Pressure (adjustable)
Reservoir Capacity 1.1 gal / 4.2 liters 1.1 gal / 4.2 liters
Shipping Weight
208-230 V, 60 Hz
Volts Range
Amps 11.9A 12.2A 12.2A 12.5A
240 V, 50 Hz
Volts Range Over Voltage
Amps 11.9A 12.2A 12.2A 12.5A
2500 watts 8525 BTU/hr 1700 watts 5797 BTU/hr 760 watts 2591 BTU/hr
20 to 100 psi
138 to 689 kPa
197 pounds
89 kg
187 to 253V
198 to 264V
Category II
2900 watts 9889 BTU/hr 1950 watts 6649 BTU/hr 1000 watts 3410 BTU/hr
20 to 100 psi
138 to 689 kPa
199 pounds
90 kg