Read these instructions carefully before using the appliance.
The POLTI SANI SYSTEM delivers saturated steam at a high temperature combined with the sanitising agent HPMED in order to lower the bacterial, fungous and viral load on the surfaces to which it is applied. This enables the possibility of cross-infections to be re­duced. The POLTI SANI SYSTEM can be used wherever it is necessary to reduce microbial con­tamination (hospitals, nursing homes, doctors’ surgeries, public places, means of tran­sport, food-processing facilities, pharmaceutical companies, etc.).
KEY
GENERATOR
A) ON/OFF switch B) Numerical keypad C) Display D) Printer
D1) Paper output
H
H
D2) Printer LED
S
S
I
I
D3) OPEN key
L
L
D4) FEED key
G
G
N
N
D5) CARD slot
E
E
E) Signalling lamp
F) Pressure indicator G) Tank cap H) Power cable
I) Carrier grip
L) Rod for supporting tube
M) Monotube
DELIVERY DEVICE
N) Delivery lamp
O) Delivery device grip
P) Steam delivery push-button
Q) Fitting for disposable bottle
Q1) Disposable bottle of HPMED
R) Adaptor for creating concentrated steam
jet
S) Spacer
T) Brush U) Card
This appliance complies with directive 93/42/EEC
TECHNICAL DATA
Voltage:........................................220-240 V~
Frequency:.......................................50/60 Hz
Max. current:.............................................11A
Max.wattage:.......................................2250W
Boiler wattage:.....................................2200W
Delivery unit wattage:..........................950W
Protection class:......................................IPX4
Fuses:.......................................................16A
Operating temperature:.........from 18 to 35°c
Operating humidity:..............from 40 to 70 %
PERFORMANCE
Steam consumption:..................... 100 g/min
*Guaranteed average consumption of
HPMED:....................................... 0.4 ml/min
Steam temperature:..............................180°C
Pressure:...............................from 4 to 6 bar
Dry saturated steam
* The operation time of the disposable bottle strictly depends on the conditions in which SANI SYSTEM POLTI is used and on the wi­deness of the surfaces to be treated.
Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.
42
SANI SYSTEM CHECK
PPRREECCAAUUTTIIOONNS
KEEP THESE INSTRUCTIONS
• The appliance is designed and made for use in closed areas, never outdoors.
BEFORE STARTING TO SANITISE, IT IS
ADVISABLE TO DIRECT THE FIRST JET OF STEAM ONTO A CLOTH OR DOWN­WARDS FOR APPROXIMATELY 30 SEC­ONDS WITHOUT HOOKING UP THE FIT­TING FOR THE DISPOSABLE BOTTLE (Q). THIS WILL ENABLE THE OPTIMUM TEMPERATURE AND PRESSURE TO BE REACHED.
• Before treating delicate or unusual surfaces with the SANI SYSTEM Polti sanitising sys­tem, consult the manufacturer’s instructions and always carry out a test on a hidden part or on a sample of the material. Allow the sanitised area to dry in order to make sure that no changes in colour or deformations have occurred.
• Read these instructions for use carefully before using the appliance, and make sure that anyone using the machine is familiar with these instructions and the warnings.
• Any use which does not comply with these instructions will invalidate the warranty.
• The wiring system to which the appliance is connected must always comply with the laws in force.
• Before connecting the appliance, make sure that the mains voltage is the same as the voltage indicated on the data label of the appliance and that the power outlet is connected to earth
• Always turn off the appliance at the on/off switch before unplugging it.
• If the appliance is left unused, always dis­connect it from the mains. Never leave the appliance unattended with the cable plugged into the mains.
• Always make sure the appliance is un­plugged before performing maintenance work of any kind
• Do not pull the power cable out of the socket, but grasp the plug itself to avoid damage to the socket.
• Do not allow the power cable to be twisted,
S
crushed, stretched, or come into contact with sharp or hot surfaces.
• Do not use the appliance if the power cable or other important parts are damaged.
• Do not use electric extension leads that are not authorized by the manufacturer, as they may cause damage or fire.
• Never touch the appliance with wet hands or feet with the cable plugged into the mains.
• Do not use the appliance when barefoot.
• Do not use the appliance near a bathtub, shower or container full of water
• Never immerse the appliance, the cable or the plugs in water or another liquid.
• Use of the appliance in places where there is a danger of explosions is prohibited.
• Do not use the product with toxic sub­stances.
• Do not lay the hot appliance on surfaces sensitive to heat.
• Do not leave the appliance exposed to wind or rain.
• Do not place the appliance near a live ele­ment, an electric stove or any other source of heat.
• Do not expose the appliance to extreme temperatures
• Never let children or people who are not fa­miliar with how the appliance works use it.
• Do not press the buttons hard or with a pointed object such as a pen.
• Always rest the appliance on a stable sur­face.
• In case of accidental fall of the appliance it is necessary to have it checked by an au­thorized Service Centre as the internal safety features may have been affected.
• In case of breakdown or malfunction switch off the appliance and never attempt to dis­assemble it, but refer to an authorized Polti Service Centre.
• To avoid prejudicing the safety of the appli­ance, use only original spare parts and ac­cessories approved by the manufacturer.
• Do not wind the power cable around the ap­pliance, especially when the appliance is still hot.
• During refilling with water, switch off and
H
H
S
S
I
I
L
L
G
G
N
N
E
E
43
SANI SYSTEM CHECK
disconnect the appliance from the mains.
• It is necessary to keep the unit in horizontal position during operation.
• Do not direct the steam jet onto electrical and/or electronic appliances.
• Let the appliance cool down before cleaning it.
• Before storing the appliance make sure that it has completely cooled down.
• This appliance is equipped with safety de­vices which are to be replaced only by a suitably qualified technician.
• Do not put any detergent or chemical sub­stance in the boiler.
• Do not direct the steam jet at people, ani­mals or debris.
• Never place your hands inside the jet of steam.
H
H
S
S
I
I
• This appliance is not intended for use by
L
L
G
G
persons (including children) with reduced
N
N
physical, sensory or mental capabilities, or
E
E
lack of experience and knowledge, unless they have been given supervision or in­struction concerning use of the appliance by a person responsible for their safety.
• Children should be supervised to ensure that they do not play with the appliance.
WARNING: Do not use any chemical pro­ducts other than those recommended by the manufacturer of the device. Polti S.p.a. guarantees correct operation of the machine and an adequate bacterici­dal, fungicidal and viricidal effect of the system only if it is used with the HPMED sanitising agent. If products other than HPMED are used, Polti will accept no liabi­lity and the guarantee will be invalidated.
CCOORRRREECCTT UUSSEE OOFF TTHHEE PPRROODDUUCCTT
This equipment is a Class IIA medical device intended for professional use, in accordance with the descriptions and instructions con­tained in this manual. The system delivers sat-
ATTENTION: Danger of burns!
WARNING: High temperature. Danger of burns! Do not touch the parts indicated on the product
urated steam at a high temperature combined with the sanitising agent HPMED in order to lower the bacterial, fungous and viral load on the surfaces to which it is applied. This makes it possible to reduce the possibility of cross-in­fections. Read these instructions carefully and keep them for future reference.
Polti S.p.A declines liability for any dam­age or accident derived from any use of this appliance which is not in conformity with the instructions contained in this manual.
AATTTTEENNTTIIOON
N
Directive 2002/96/EC (Waste Electrical and Electronic Equipment - WEEE): information for users This product complies with EU Directive 2002/96/EC.
The crossed-out wastebasket sym­bol on the appliance means that at the end of its useful lifespan, the
product must be disposed of sepa­rately from ordinary household wastes. The user is responsible for delivering the ap­pliance to an appropriate collection facility at the end of its useful lifespan. Appropriate separate collection to permit re­cycling, treatment and environmentally com­patible disposal helps to prevent negative im­pact on the environment and human health and promotes recycling of the materials mak­ing up the product. For more information on available collection facilities, contact your lo­cal waste collection service.
D
HHPPMMEED
The sanitising agent
Its characteristics make it the ideal comple­ment to SANI SYSTEM POLTI for sanitising any surface at risk of contamination by patho­genic organisms, and in particular bacteria. The action of HPMED is enhanced when combined with high temperature. Thus, the dry steam of SANI SYSTEM POLTI becomes the ideal means for carrying the temperature and the HPMED sanitising agent, which is able in this way to reach even the least ac-
44
SANI SYSTEM CHECK
cessible nooks. While it sanitises, it also elim­inates smells.
Instructions for use :
Fit the disposable bottle into the delivery de­vice following the instructions in paragraph “DISPOSABLE BOTTLE OF HPMED”.
Switch on the SANI SYSTEM POLTI ma­chine following the manufacturer’s instruc­tions. Once the system is ready, distribute the steam and HPMED sanitising agent. Mixed with the steam, the product will dry within 30 seconds to one minute, depending on the en­vironmental conditions.
Warnings :
Keep out of the reach of children. Do not in­gest. In case of contact with eyes, rinse with plenty of water and seek medical advice. A safety data sheet is available for profes­sional users. For professional use only. HPMED is a cleaning sanitisin product for hard surfaces. Contains <5% non-ionic sur­factant. (EEC Reg. 648/2004).
PPRREEPPAARRIINNGG FFOORR UUSSE
• Unscrew the cap (G) from the tank and fill
the tank with about 4.5l of normal tap water. Disconnecting of the device from the power mains before filling is recommended.
• Fit the carrier grip as shown in Fig.1, tighte­ning the two screws on the rear of the grip to secure it in place.
• Insert the tube-holder rod (L) into its hole (Fig.2).
• Plug the power cable (H) into the panel­type socket on the rear of the device. Plug the connector on the other end of the power cord into a suitable socket with an earth connection.
Fit the disposable bottle into the delivery de-
vice following the instructions in paragraph “DISPOSABLE BOTTLE OF HPMED”.
N
LLOOGGIIN
• Turn the ON-OFF switch (A) to position "I".
• The date and time will appear on the dis­play (C). Press “OK” on the numerical key­pad (B) to confirm. If the date and time are
E
not displayed automatically, it will be neces­sary to enter them by hand using the nu­merical keypad and then pressing “OK” to confirm.
• The prompt “PRINT last logout?” will ap­pear on the display. Press “OK” on the nu­merical keypad if you wish to print the lo­gout summary of the last work session. Otherwise press “CANC”.
• The device will start up and the word LO- GIN will appear on the display.
• Insert the CARD (U) into the slot provided for it (D5).
• The following information will appear:
“HEATING” (flashing) to indicate that the de­vice is in the heating stage. Once the correct pressure is reached, the word “READY” will appear to show that the device is ready for use. The indication IDXX will also appear (XX cor­responds to the number of the CARD inserted at the time).
N.B.: Do not remove the CARD from the slot during use.
If the CARD is removed during use, the ma­chine will stop working and the message “LOCKED - INSERT CARD IDXX” will appear on the display. To unlock the machine and re­sume work, it is necessary to insert the same card used earlier to log in. The work data will remain stored in the memory. The CARDS supplied with the machine are already configured and will work only in the machine with which they were supplied. If new cards are purchased, they will have to be initialized. To do this, proceed as described in the section “INITIALISING NEW CARDS”.
• Once you have logged in, the following in­formation will appear on the display:
Prog:__” It is necessary to insert the number of the programme you wish to use. The pro­gramme numbers have two digits. There are four pre-set programmes: 00, 01, 02 and 03. Enter the number of the chosen programme via the numerical keypad and press OK. If you have entered the wrong programme number, you can delete the entry with the CANC key.
H
H
S
S
I
I
L
L
G
G
N
N
E
E
45
SANI SYSTEM CHECK
“AREA” The user is responsible for coding of
the area, which is not managed by the prod­uct software. This field is free and optional. It is possible to assign a number to each area to be treated, so that the operations carried out can be traced. If the AREA number is en­tered, it will be shown on the slip. Enter the number of the area (from 01 to 99) or, if you do not wish to code the work area, enter 00. In both cases, press OK to confirm.
To delete an incorrectly entered area number, use the CANC key. Furthermore, the CANC key can also be used to return to the previous menu for selecting the programme.
Once these parameters have been entered, the following information will appear on the di­splay:
H
H
Prog:__ Indicates the programme that has
S
S
I
I
been selected.
L
L
G
G
TIME:___ indicates the time left, in seconds,
N
N
depending on the chosen programme.
E
E
PPRROOGGRRAAMMMMEES
PROGRAMME 00
Programme 00 is a free programme by means of which the user can produce steam for a maximum of 3600 seconds. After 3 seconds of delivery, the prompt “PRINT?” will appear on the display and the signalling lamp (E) will light up. From this moment on, it will be possible to print a slip containing the data referred to the sanitising cycle carried out. Printing is started:
• by pressing OK
• upon timeout (after 3600 seconds of actual delivery)
• on LOGGING OUT.
If you press the CANC key, the slip will not be printed, the information will be stored and when you LOG OUT, all the information con­cerning the work carried out will be printed on a single summary slip.
S
PROGRAMMES 01 / 02 / 03
Programmes 01, 02 and 03 are predefined programmes that differ in terms of the actual delivery time that is pre-set:
01 - 180 seconds + 60 seconds (extra time) 02 - 360 seconds + 120 seconds (extra time) 03 - 600 seconds + 180 seconds (extra time)
The length of the programme is expressed as the actual time of delivery of steam. At the end of the minimum time provided for each programme (programme 01 - 180 se­conds; 02 - 360 seconds; 03 - 600 seconds) the signalling lamp (E) will light up, an acou­stic signal will sound and the prompt “PRINT?”. will appear on the display. At this point it twill be possible to end the ope­rations and to print the slip by pressing OK. It is in any case possible to continue delive­ring steam for an extra period of time that de­pends on the programme that was selected (programme 01 - 60 seconds; 02 - 120 se­conds; 03 - 180 seconds). It is possible to end the operations and print the slip by pressing OK even if the extra time is not completed. Whenever the prompt “PRINT?” appears on the display, two options are available:
• If you press OK, the slip containing the information about the programme that has just ended will be printed.
• If you press CANC, the slip will not be prin­ted, the information will be stored and when you LOG OUT, all the information concer­ning the work carried out will be printed on a single summary slip.
The slip will indicate “PROG: OK” if the cycle has been carried out correctly, or “PROG: NOT VALID” if the cycle was broken off by the user LOGGING OUT or in case of mal­functioning of the device.
EENNDD OOFF OOPPEERRAATTIIOONNSS // LLOOGGOOUUT
Once the sanitising operations have been completed, you must LOG OUT. To LOG OUT, hold the CANC key down for 4 seconds. At this point a summary of the operations from the LOGIN to the LOGOUT will be prin­ted.
T
46
SANI SYSTEM CHECK
The device will then return to its initial confi­guration and require a LOGIN. To LOG IN again, you must remove the CARD from the slot and to insert a card again. To end the operations, turn off the machine by means of the ON-OFF switch (A).
N.B.: If the CARD used to LOG IN is mi slaid or damaged, it is possible to unlock the machine using the “SUPER USER” CARD (S.U.) (included in the supply). When you insert this CARD into the slot (D5), the LOGOUT procedure will be car­ried out automatically and the summary of the last work session will be printed.
SSTTEEAAMM DDEELLIIVVEERRY
• Press the steam delivery push-button (P) to
obtain the production of steam from the de­livery device. The delivery lamp (N) will ex­tinguish when the resistor inside the deli­very device has reached its running temperature. The steam delivery push-button (P) has a “safe position” so as to avoid accidental de­livery of steam.
Note:
• While the device is in use, the delivery si-
gnalling lamp (N) lights up and extingui­shes.
. This indicates that the resistors are starting
to work in order to keep the pressure in the boiler and the temperature in the delivery device steady. It is therefore possible to continue sanitising regularly, as this occur­rence is normal.
BEFORE STARTING TO SANITISE, IT IS
ADVISABLE TO DIRECT THE FIRST JET OF STEAM ONTO A CLOTH OR DOWNWARDS FOR APPROXIMATELY 30 SECONDS WITHOUT HOOKING UP THE FITTING FOR THE DISPOSABLE BOTTLE (Q). THIS WILL ENABLE THE OPTIMUM TEMPERATURE AND PRES­SURE TO BE REACHED.
Y
TTIIPPSS FFOORR UUSSE
Before treating delicate or special surfaces with the SANI SYSTEM POLTI sanitising sy­stem, consult the manufacturer’s instructions and carry out a test on a hidden part of the surface or on a sample of the material. Allow the sanitised part to dry to make sure
-
that no changes in colour or deformations have occurred.
Make sure that the surface to be treated is clean before sanitising it. In the event of visible dirt, clean the surface before saniti­sing it. Direct the steam downwards for 2 se conds in order to bring all the components of the machine to their correct tempera­ture, in order to avoid condensation.
Bring the delivery nozzle into a position per­pendicular to the surface to be sanitised and keep it at a distance of 10 cm, as provided by the spacer, avoiding direct contact of the lat­ter with the surface. Deliver the steam on a continuous movement, using “brushing” mo­vements to cover the surface to be sanitised.
Repeated treatments will lead to more efficient sanitising of the treated surfaces.
SANI SYSTEM POLTI delivers saturated steam that, added to HPMED, will dry without leaving residues within 30 seconds to 1 mi­nute, depending on the environmental condi­tions. To sanitise piping, drains, etc., connect the delivery nozzle to the adaptor (R), to obtain a concentrated output jet of steam. Before star­ting to use the device, make sure that the ma­terial to be treated can withstand the high temperature.
PPRREESSSSUURREE IINNDDIICCAATTOORR
Precision: Class 2.5 This device has a handy and accurate indica­tor (F) for displaying the operating pressure immediately. When the device is on stand-by, that is to say it is switched on but no steam is being delivered, the pressure is kept steady at between 4 and 6 bars.
E
-
H
H
S
S
I
I
L
L
G
G
N
N
E
E
47
SANI SYSTEM CHECK
DDIISSPPOOSSAABBLLEE BBOOTTTTLLEE OOFF HHPPMMEEDD
• Unscrew the cap of the disposable bottle.
• Screw the bottle (Q1) to the fitting (Q) as
shown in Figure 3.
• To connect and disconnect the disposable adapter to SANI SYSTEM delivery device, fit the coupling on the upper part of the con­nector (Q) into the one placed on the bottom of the delivery device, pressing them to­gether until they click into place (fig.4). To di­sconnect the connector, simply press the le­ver on it and separate the two components (fig.5).
As soon as the level of HPMED contained in the disposable bottle drops below the low level indicated on the label, replace it with a new bottle. Once the disposable bottle has been opened and fitted onto the delivery nozzle, the sanitis-
H
H
ing efficiency of the product is guaranteed for 7
S
S
I
I
days. If the bottle has been only partly used af-
L
L
ter this period of time, it is in any case advis-
G
G
N
N
able, therefore, to remove it and replace it with
E
E
a new one.
Do not refill the disposable bottle. To carry out correct sanitising, we recommend reading the instructions for using Sani System carefully.
CCOONNNNEECCTTIIOONN OOFF AACCCCEESSSSOORRIIEESS
The following accessories can be connected to the delivery nozzle:
Adaptor for creating concentrated steam jet (R):This accessory provides a concentra-
ted output jet of steam. To fit this accessory match up the teeth on the adaptor with the openings on the tip of the nozzle. Place the accessories against the nozzle, pushing it as far as it will go, then turn it in a clockwise di­rection (Fig. 6).
Spacer (S): The spacer is used to keep at the correct distance from the surface to be trea­ted in order to sanitise it correctly. To fit the spacer, insert the tip of the delivery nozzle into the ring of the spacer, first on the side op­posite to the fixing ring, then match the ring of the spacer with the tip of the nozzle and fix them together by turning the fixing ring (Fig.7).
LLAACCKK OOFF WWAATTEERR
When the water inside the tank is used up, the wording “WATER EMPTY” will appear in­termittently on the display and an acoustic si­gnal will sound. To resume use, fill the tank again as described un the section “Prepara­tion for use”.
TTRRAANNSSPPOORRTT
This device can be moved easily by means of the transport grip (I) on the rear of the device or using the two side handles. If required, the transport grip can be removed by unscrewing the two wing screws on the rear of the handle.
WARNING: Never drag the device by the nozzle. Move it only by means of the grip (I) or the two side handles.
SSTTOORRIINNGG TTHHEE DDEEVVIICCEE.
When you have finished using the device, put it away in a clean and dry place after discon­necting it from the power mains. Keep it away from sources of heat and protect from the weather. Do not expose the device to extreme temperatures.
.
WARNING! When using this acces­sory, the connector of the disposable bottle (Q) must not be connected to
the delivery device.
.
48
SANI SYSTEM CHECK
UUSSIINNGG TTHHEE PPRRIINNTTEERR
To change the paper roll, proceed as follows:
• Open the lid of the printer by pressing the OPEN key (D3) (Fig.8).
• Position a paper roll inside the compart­ment, observing the direction of rotation as indicated (Fig.9).
• Pull the end of the paper so that it leads out of the compartment, then close the lid (Fig.10).
• Tear off the excess paper against the serra­ted edge (Fig.11).
• It is possible to move the paper forward by pressing the FEED key (D4).
Use thermal paper for slips, easily found on the market. Store the paper in a dry place and away from direct sunlight in order to ensure a longer life both of the paper and of the data printed on it.
IINNIITTIIAALLIISSIINNGG NNEEWW CCAARRDDSS
If you purchase any new cards over and above those supplied with the machine, they will have to be initialized. With the machine switched off, press keys 1 and 2 on the numerical keypad, both at the same time. Use the switch (A) to turn on the machine, then release keys 1 and 2. The indi­cation “INITIALIZE CARD XX” will appear on the display (XX corresponds to the number of the card to be initialised. It is a progressive number that cannot be repeated). Insert the new CARD in the slot. Do not remove the CARD until the information “CARD XX INI­TIALIZED” appears on the display. Remove the CARD from the slot. Once the card has been removed, the system will prompt you to initialize another card. To do this, follow the instructions as above. To exit, turn of the ma­chine using the switch (A). A CARD that has already been initialised cannot be overwritten.
MMAAIINNTTEENNAANNCCE
Before carrying out any maintenance on the device, always unplug it from the power mains and allow it to cool down before proceeding.
If the monotube is torn, it must be replaced by an authorised service centre.
Cleaning of the delivery nozzle
Clean the delivery nozzle every 10-15 hours of use. Clean the delivery nozzle using the brush (T) included in the supply, sliding it in­side the tube so as to remove any residues of scaling in it (Fig.12).
Lubrication of the coupling
Whenever it is difficult to fit the connector (Q) and in any case when the device has not been used for some time, lubricate the cou­pling on the bottom of the delivery device (fig.13) with a synthetic lubricant. It you find it difficult to insert the connector even after lu­bricating, contact an authorized service cen­ter.
Tips
In the event of external factors such as, for example, a sudden change in voltage due to an upset in the network (failure, lightning, etc.), the device may be affected by electrical interference and be subject to temporary mal­functioning. To reset the device, switch it off and discon­nect it from the mains for a few minutes. After this procedure, start it again normally. If it still does not work correctly, ask for a check up at an authorised service centre. Having the device checked after a problem of this kind is recommended.
External cleaning
For cleaning the outside of the device we re­commend using a damp cloth. Do not use sol­vents or detergents as these could damage the surfaces. Pay special attention to the cleanliness of the outside of the device when moving from one room to another, cleaning the wheels too.
E
H
H
S
S
I
I
L
L
G
G
N
N
E
E
49
SANI SYSTEM CHECK
WARNING: For all other maintenance pro­cedures and whenever necessary, contact an authorised service centre. Do not at­tempt under any circumstances to disas­semble the device or to open it.
Two adhesive anti-tampering labels are ap­plied to the product. If these labels are re
moved or damaged by unauthorised per­sonnel the guarantee will no longer be valid.
H
H
S
S
I
I
L
L
G
G
N
N
E
E
-
50
PROBLEM SHOWN ON DISPLAY SOLUTION
Boiler empty / pump takes too long to charge
Pressure in boiler not correct
SANI SYSTEM CHECK
TTRROOUUBBLLEESSHHOOOOTTIINNG
“WATER MISSING” (flashing)
“BOILER PRESSURE” (fla­shing) and intermittent acou­stic signal
G
Turn off the machine then on again after a few seconds, using the ON-OFF switch (A). If the problem persists contact an authorised Service Centre.
Turn off the machine then on again after a few seconds, using the ON-OFF switch (A). If the problem persists contact an authorised Service Centre.
Operating temperature not correct
Lack of water in boiler
The device does not enable access to the user
The machine stops and no longer delivers steam.
“WRONG TEMP. B”
“WRONG TEMP. L”
“WATER MISSING” and conti­nuous acoustic signal
« CARD NOT VALID »
« LOCKED INSERT CARD »
Turn off the machine then on again after a few seconds, using the ON-OFF switch (A). If the problem persists contact an authorised Service Centre.
Turn off the machine then on again after a few seconds, using the ON-OFF switch (A). If the problem persists contact an authorised Service Centre.
Contrôler que la carte est cor­rectement insérée.
Si on utilise une nouvelle car­te, effectuer l’initialisation de la CARTE comme décrit dans le manuel.
La CARTE a été retirée de la fente. Pour recommencer à travailler insérer à nouveau la CARTE utilisée pour le LO­GIN. L’insertion d’une autre carte ne permettra pas de dé­bloquer la machine.
H
H
S
S
I
I
L
L
G
G
N
N
E
E
Power cut
The device stores all the ope­rations carried out, but not the one for the programme being run and which has possibly been interrupted.
51
Resume operations after the power supply has returned to normal.