PNI BT5500, BT5300 Operation Manual

Page 1
OPERATION MANUAL
MODELS BT5500 & BT5300
BREATHALCOHOLDETECTOR
WARNING/AGREEMENT: Because of the vari­ables involved in the timing of alcohol consump­tion, individual metabolism, and self-administration, the user of this product agrees (1) not to hold the manufacturer, dealer, wholesaler, or distribu­tor responsible for the consequences of any deci­sion, based on the use of this product, to operate a vehicle, boat, or aircraft or other equipment and (2) to hold them harmless from the claims of others arising out of any such decision. IF YOU DO NOT AGREE, YOU SHOULD PROMPTLY RETURN THIS PRODUCT TO THE PLACE OF PURCHASE, UNUSED, FOR A FULL REFUND.
Page 2
Intended Use:
The AlcAlert Breath Alcohol Detector is a screening test device for the rapid detection of alcohol in the breath. The test is used to obtain a visual quantitative result that approximates the level of alcohol concentration in the blood stream, and is intended for over the counter sale to the home user.
Page 3
1
BEFORE USING THE ALCALERT
The
AlcAlert Breath Alcohol Detector
uses advanced semi-conductor gas sensor technology to approximate the percent of blood alcohol concentration (BAC) from your breath. Please take a few moments to review the entire manual before using the unit.
When inserting batteries (not included with all models), please note the correct polarity on the inside of the battery case. Inserting the batter­ies with the incorrect polarity may damage the unit.
Do not blow smoke or uids into the unit, as this may damage the sensor. Similarly, certain gases such as sil­icone compounds, sulfur, and freon gases can also damage your sensor. Keep the unit away from all liquids and store in a safe environment.
If the
AlcAlert
needs to be cleaned, wipe gently with a soft cloth. Do not use any cleaning agents.
Allow 30 minutes after consuming alcohol or smoking before using the unit. This helps to ensure the breath sample is taken from your lungs,
Page 4
2
and not from the alcohol within your mouth, which may result in a higher reading. In some cases, it may take up to one hour to reach the highest blood alcohol level after the last con­sumption of alcohol.
Each individual’s body responds to the consumption of alcohol differ­ently. Consequently, a person’s abil­ity to drive safely may be impaired at a point well below the legal blood alcohol limit.
USING THE ALCALERT
1. Press the “On” button
The unit beeps once, the “WAIT” indicator ashes, and the unit begins a “warm-up” countdown from 14-to-0 or 6-to-0 (see Additional Informa­tion). You must wait until the count­down is completed. Proceed with step 2 only when the unit beeps twice and the “BLOW” indicator ashes.
NOTE: If “SAT” (saturation) ashes after the countdown is completed and the unit turns off, the sensor is sat-
Page 5
3
WAIT BLOW
JAPAN
WAIT BLOW
%BAC
Low Battery WAIT, BLOW, Indicator and %BAC Indicators
Figure A
Vents
“On” Button
LCD Readout
Battery Compartment (slide down to open)
Page 6
4
urated. Simply reactivate the unit to perform another warm-up countdown cycle. If “SAT” appears again, repeat this process as many times as neces­sary until “SAT” no longer appears. In most instances, 2 or 3 reactivation cycles should clear the “SAT” mes­sage. More reactivation cycles may be required if saturation is extensive (see Additional Information).
2. Blow into the vent
Blow continuously for about 5 seconds, until the unit beeps 3 times before dis­playing the results. Immediately as you
start to blow, Err” (Error) ashes until the unit beeps 3 times. Blow very gently from between your lips, as if cooling a spoonful of soup. A distance of about one inch (2-3 cm) between the vent and the mouth is suggested. (See gure A.)
Note: If you do not blow at all, or if you stop blowing before you hear 3 beeps, the LCD ashes “Err” to indicate that you did not apply any or sufcient breath through the vent. If so, ignore the results and repeat the process.
Page 7
5
3. Read the results The %BAC results are displayed on the LCD for about 5 seconds after the reading is taken. The results then ash for a few seconds until the unit turns off automatically.
The results are shown in increments of 0.01, ranging from 0.00 to 0.12. Results greater that 0.12 %BAC are displayed as “+.12”.
Understanding the results
The BAC (Blood Alcohol Concentration) represents the amount of ethyl alcohol in
a given volume of blood. For instance, having a %BAC of 0.10 means that a person has 1 part alcohol per 1,000 parts blood in the body.
The most commonly used measurements are grams of ethanol per milliliter of blood (g/ml), used in the United States (also expressed as %BAC) and milli­grams of ethanol per milliliter of blood (mg/ml), used in much of Europe (also expressed as promille).
For example, a reading of 0.05 %BAC on the AlcAlert is the same as 0.05 g/ml or 50 mg/ml or 0.5 g/l or 0.5 promille.
Page 8
6
ADDITIONAL INFORMATION
The normal warm-up countdown is from 6-to-0. However, if it has been more than 1 hour since the last operation, the unit begins a 14-to-0 warm-up countdown.
The sensor must be warmed up
properly to report accurate read­ings. Therefore, for maximum accu­racy, each time you start to use the unit after it has been idle for a time, always disregard the results fol­lowing the initial 14-to-one count-
down, as well as the next three 6-to-0 countdowns.
The “SAT” (saturation) message fea­ture prevents the unit from display­ing inaccurate %BAC readings in the case of sensor saturation by contam­inating agents. For example, satu­ration often occurs when excessive alcohol moisture is deposited on the sensor from multiple consecutive uses, or by the accumulation of air contaminants on the sensor after a long period of inoperability, such as upon rst use. In such instances,
Page 9
7
the unit requires additional warm-up cycles to properly recondition the sensor.
If the low battery indicator ashes then remains on, replace the batter­ies.
The
AlcAlert
Model BT5500 includes a backlight. The backlight turns on and off automatically.
Always blow into the unit in a consistent manner. Different blow­ing conditions may produce different results.
Your unit is more accurate when your true blood alcohol concentra­tion is between 0.02 %BAC and 0.08 %BAC and less accurate as your blood alcohol concentration is over
0.08 %BAC.
When tested with a standard 0.08% BAC solution, the unit may read in the range from 0.06 to 0.10. Thus, a reading of .06 may well indicate a level of 0.08% BAC.
Each individual’s body responds to
the consumption of alcohol differ-
Page 10
8
ently. Consequently, a person’s abil­ity to drive safely may be impaired at a point well below the legal blood alcohol limit.
The
AlcAlert
should be used only to give an indication of the possible presence of alcohol in the blood. Do not rely upon it as the sole basis to determine intoxication or whether it is safe to drive a vehicle, operate equipment, or engage in dangerous activities.
PNI Corporation does not recom-
mend drinking and driving. If you are going to drink alcohol, always have a non-drinking designated driver. Do not drink and drive!
SPECIFICATIONS
Dimensions/Weight: 3 x1x inches / 1.6 oz.; (90 x 31.5 x 16.5 mm / 50 grams)
Sensor: Semiconductor gas sensor
Page 11
9
Accuracy*: ±20% at 0.08 %BAC for 2 years, under normal operating conditions and fac­tors**
Display: %BAC in 0.01 increments ranging from 0.00 to 0.12
Power/Battery life: 2 AAA alkaline batteries for over 300 uses
Product lifetime: 2 years, under normal operating condi­tions and factors
Temperature range:
Storage: -4° to 158°F (-20° to 70°C) Operating: 32° to 104°F (0° to 40°C )
* Accuracy varies depending on individ-
ual metabolism, blowing conditions, humidity, and the condition of the sensor.
** Normal operating conditions and fac-
tors means an ambient temperature range of 50°F to 95°F; a relative humidity range of 40% to 60%; a clean air environment (no contamination or poisoning agents), and normal usage (less than 20 operations/day).
Page 12
10
SERVICE AND REPLACEMENT
Customer Service
For support questions, please contact our customer service department by e-mail at customerservice@pnicorp.com, or call us between 8:00 a.m. and 5:00 p.m. (PST), Monday through Friday.
Warranty Service
For the fastest service, it is best to contact or return your unit to the place of purchase within 30 days of the purchase. If you wish to return the unit for replacement or repair to PNI Corporation, please follow the following procedures:
1. Obtain a return merchandise authori­zation (RMA) number by contacting PNI:
• By phone at (888) 422-6672 (toll-
free within the U.S.A. only) or at (707) 566-2260.
• By fax at (707) 566-2261
• By e-mail at
customerservice@pnicorp.com
2. Provide a proof of purchase, such as a mechanical reproduction or carbon copy of a sales receipt. If you send your original receipt, it cannot be returned. Proof of purchase must show printed date of purchase, model number, and
Page 13
11
place of purchase. There will be a charge for repair or replacement if no proof of purchase is provided or if the unit is past the warranty period.
Once you have acquired an RMA
number, pack the unit securely to prevent damage in transit. If possible, use the original packing material. Be sure to send the entire product.
3. Ship prepaid and insured by way of a traceable carrier, such as United Parcel Service (UPS), FedEx, or First Class Mail to avoid loss in transit.
4. Write the issued RMA number on the
outside of your package and send your proof of purchase and description of the problem to the following address:
PNI Corporation Attn: RMA# ________________
5464 Skylane Blvd., Suite A Santa Rosa, CA 95403-1084
Type or print your name and address
where the replacement should be delivered. After receipt of your documents and unit, a replacement unit will be sent to you. Please allow 2 to 3 weeks from receipt of your returned product to delivery of your replacement.
Page 14
12
LIMITED WARRANTY; LIMITATION OF LIABILITY
PNI Corporation (“PNI”) manufactures its prod­ucts, which include accessories, from parts and components that are new or equivalent to new in performance and expressly warrants to the origi­nal retail purchaser who is also the original user that this product will be free of defects in work­manship and materials for ninety (90) days from the date of purchase. Implied warranties are lim­ited to such person for the same period.
If the product is found by PNI to be defective, PNI’s entire liability and your exclusive remedy for breach of warranty, express or implied, shall be that PNI will repair or replace the product and return the product or its replacement to you at no charge, provided that you ship the product to PNI at your expense with a description of the defect and subject to the other conditions of this war­ranty. Should the product prove to be irreparable,
PNI may substitute an equivalent product of the same or similar style and of a value not in excess of the original purchase price of your product. PNI warrants the repaired or replacement prod­uct to be free from defects in material and work­manship for the balance of the original warranty period, extended by the time period from your shipment to PNI for repair or replacement until the repaired or replaced product was received by you.
This warranty will be void if the serial number or other identication marks on the product or its accessories have been defaced, damaged or removed. This warranty does not cover wear and tear due to normal use, or damage to the product as the result of improper usage, neglect of care, alteration, accident or unauthorized repair, nor does this warranty apply to the battery necessary to operate the product.
This warranty is extended only to the original retail purchaser who is also the original user and
Page 15
13
may not be transferred or assigned to subsequent owners. In order to validate your warranty, you must provide proof of purchase acceptable to PNI, together with the product shipped for warranty repair or replacement. Products returned to PNI must be pre-authorized by PNI with an RMA (return material authorization) number marked on the outside of the package. Please refer to the Ser­vice and Replacement section for PNI Corpora­tion contact information.
THE FOREGOING WARRANTY IS GIVEN IN LIEU OF AND PNI DISCLAIMS ALL OTHER EXPRESS WARRANTIES OR REPRESENTA­TIONS IN FACT OR IN LAW WITH RESPECT TO THIS PRODUCT, INCLUDING, BUT NOT LIMITED TO, ANY WARRANTY OR REP­RESENTATION THAT USE OF THE PROD­UCT WILL BE UNINTERRUPTED OR ERROR FREE.
Except for the breach of warranty remedies set forth herein, or for personal injury, PNI shall have
no liability for any indirect or speculative dam­ages (including, but not limited to, consequential, incidental, punitive and special damages) relat­ing to the use of or inability to use this product, whether arising out of contract, negligence, tort, or under any warranty theory, or for infringement of any other party’s intellectual property rights, irrespective of whether PNI had advance notice of the possibility of any such damages, including, but not limited to, loss of use, revenue or prot. In no event shall PNl’s total liability for all claims regarding the product exceed the price paid for the product. PNI neither assumes nor authorizes anyone to assume for it any other liabilities.
Some states and provinces do not allow limita­tions on how long an implied warranty lasts or the exclusion or limitation of incidental or con­sequential damages, so the above limitations or exclusions may not apply to you. This warranty gives you specic legal rights and you may have other rights that vary by state or province.
Page 16
Your Opinion Matters!
Please take a few minutes to register and let us know
about yourself. It will help us serve you better in the
future, and all information will remain condential.
To register, log on to:
www.pniservice.com
PNI Corporation www.pnicorp.com
11085 R02 1000813
Loading...